Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleTheranostics

68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer

Clemens Kratochwil, Paul Flechsig, Thomas Lindner, Labidi Abderrahim, Annette Altmann, Walter Mier, Sebastian Adeberg, Hendrik Rathke, Manuel Röhrich, Hauke Winter, Peter K. Plinkert, Frederik Marme, Matthias Lang, Hans-Ulrich Kauczor, Dirk Jäger, Jürgen Debus, Uwe Haberkorn and Frederik L. Giesel
Journal of Nuclear Medicine June 2019, 60 (6) 801-805; DOI: https://doi.org/10.2967/jnumed.119.227967
Clemens Kratochwil
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul Flechsig
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
2Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Lindner
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Labidi Abderrahim
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Annette Altmann
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
3Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Walter Mier
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastian Adeberg
4Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg, Germany
5Heidelberg Institute for Radiation Oncology, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hendrik Rathke
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Manuel Röhrich
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hauke Winter
2Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
6Department of Surgery, Thoraxklinik at University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter K. Plinkert
7Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frederik Marme
8Department Obstetrics and Gynecology, University Hospital Heidelberg, Heidelberg, Germany
9Department Obstetrics and Gynecology, University Hospital Mannheim, Mannheim, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthias Lang
10Department of Surgery, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hans-Ulrich Kauczor
2Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
11Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dirk Jäger
12Department of Medical Oncology and Internal Medicine VI, National Center for Tumor Diseases, University Hospital Heidelberg, Germany
13Clinical Cooperation Unit Applied Tumor Immunity, German Cancer Research Center, Heidelberg, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jürgen Debus
4Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg, Germany
5Heidelberg Institute for Radiation Oncology, Heidelberg, Germany
14Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Uwe Haberkorn
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
2Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
3Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frederik L. Giesel
1Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The recent development of quinoline-based PET tracers that act as fibroblast-activation-protein inhibitors (FAPIs) demonstrated promising preclinical and clinical results. FAP is overexpressed by cancer-associated fibroblasts of several tumor entities. Here, we quantify the tumor uptake on 68Ga-FAPI PET/CT of various primary and metastatic tumors to identify the most promising indications for future application. Methods: 68Ga-FAPI PET/CT scans were requested by various referring physicians according to individual clinical indications that were considered insufficiently covered by 18F-FDG PET/CT or other imaging modalities. All PET/CT was performed 1 h after injection of 122–312 MBq of 68Ga-FAPI-04. We retrospectively identified 80 patients with histopathologically proven primary tumors or metastases or radiologically unequivocal metastatic lesions of histologically proven primary tumors. Tumor uptake was quantified by SUVmax and SUVmean (60% isocontour). Results: Eighty patients with 28 different tumor entities (54 primary tumors and 229 metastases) were evaluated. The highest average SUVmax (>12) was found in sarcoma, esophageal, breast, cholangiocarcinoma, and lung cancer. The lowest 68Ga-FAPI uptake (average SUVmax < 6) was observed in pheochromocytoma, renal cell, differentiated thyroid, adenoid cystic, and gastric cancer. The average SUVmax of hepatocellular, colorectal, head–neck, ovarian, pancreatic, and prostate cancer was intermediate (SUV 6–12). SUV varied across and within all tumor entities. Because of low background in muscle and blood pool (SUVmax < 2), the tumor-to-background contrast ratios were more than 3-fold in the intermediate and more than 6-fold in the high-intensity uptake group. Conclusion: Several highly prevalent cancers presented with remarkably high uptake and image contrast on 68Ga-FAPI PET/CT. The high and rather selective tumor uptake may open up new applications for noninvasive tumor characterization, staging examinations, or radioligand therapy.

  • FAPI
  • breast cancer
  • colorectal cancer
  • lung cancer
  • PET/CT

Several tumor entities, such as breast, colon, and pancreatic carcinomas, are characterized by a strong desmoplastic reaction (1). Cancer-associated fibroblasts and extracellular fibrosis can contribute up to 90% of the gross tumor mass, leaving original tumor cells in the minority (2,3). Many cancer-associated fibroblasts differ from normal fibroblasts by their relative specific expression of fibroblast activation protein (FAP). Therefore, FAP-specific inhibitors were first developed as anticancer drugs and then were consecutively advanced into tumor-targeting radiopharmaceuticals (4,5).

A biodistribution and initial dosimetry study of 68Ga-FAP inhibitor (FAPI) PET/CT with 2 DOTA-containing ligands suggested that these tracers may expand and enrich the diagnostic cancer portfolio currently covered by 18F-FDG (6). Moreover, the biodistribution suggested that 68Ga-FAPI may be suitable for radioligand therapy (7). In view of the favorable initial results, 68Ga-FAPI PET/CT was requested by various referring physicians on the basis of individual clinical indications. Often, scans were ordered to improve tumor delineation for planned surgery or radiotherapy. Thus, even lesions that were already unequivocally identified radiologically or by histopathology could be additionally characterized with 68Ga-FAPI PET/CT.

The aim of this retrospective analysis was to quantify 68Ga-FAPI uptake in a variety of primary, metastatic, or recurring cancers.

MATERIALS AND METHODS

Patients

All patients were referred for experimental diagnostics by their treating oncologists, who were facing an unmet diagnostic challenge that could not be solved sufficiently with standard diagnostic means. Although the location and nature of tumor lesions were frequently known, the intent was to improve tumor delineation for reasons such as planning of radiotherapy. All patients gave written informed consent to receive 68Ga-FAPI PET/CT on an individual-patient basis. The data were analyzed retrospectively with approval of the local ethics committee (approval S016/2018).

Radiopharmaceuticals

Synthesis and labeling of 68Ga-FAPI-04 have already been described previously (4,5). Following the regulations of the German Pharmaceuticals Act §13(2b), the indication for the exam and labeling of the FAPI tracers was done under the direct responsibility of the applying physician. Injected activities were dependent on labeling yields. According to a previous dosimetry estimate—effective dose, 1.6 mSv/100 MBq (6)—an upper limit of 370 MBq regarding radiation exposure and a lower limit of 100 MBq per examination to achieve a sufficient count rate have been considered.

PET/CT Imaging

All imaging was performed on a Biograph mCT Flow scanner (Siemens). After non–contrast-enhanced low-dose CT (130 keV, 30 mAs, CareDose; reconstructed with a soft-tissue kernel to a slice thickness of 5 mm), PET was acquired in 3-dimensional mode (matrix, 200 × 200) using FlowMotion (Siemens). The emission data were corrected for randoms, scatter, and decay. Reconstruction was performed with an ordered-subset expectation maximization algorithm with 2 iterations/21 subsets and was Gauss-filtered to a transaxial resolution of 5 mm in full width at half maximum; attenuation correction was performed using the nonenhanced low-dose CT data. The injected activity for the 68Ga-FAPI examinations was 122–312 MBq, and the PET scans were started 1 h after injection. A 500-mL volume of saline with 20 mg of furosemide was infused from 15 min before to 30 min after tracer application. The patients were asked to self-report any abnormalities 30 min after finishing the examination.

Imaging Evaluation

Tumor tracer uptake was quantified by SUVmean and SUVmax at 1 h after injection. For calculation of the SUV, circular regions of interest were drawn around the tumor lesions with focally increased uptake in transaxial slices and automatically adapted to a 3-dimensional volume of interest with e.soft software (Siemens) at a 60% isocontour. The unspecific background in blood pool (aortic vessel content) and muscle was quantified with a circular 2-cm-diameter sphere.

RESULTS

Adverse Events

All patients tolerated the examination well. No drug-related pharmacologic effects or physiologic responses occurred. During injection and the 1.5 h of follow-up, no patient reported any new symptoms.

Quantifying 68Ga-FAPI Uptake in Primary Tumors and Metastatic Disease

Patient numbers were not sufficient to compare the SUVs of primary tumors versus metastases for individual cancers. The overall SUV mean (11.5 ± 5.5 vs. 10.0 ± 6.3), median (10.7 vs. 8.5), and range (2.9–21.6 vs. 2.0–44.8) of 68Ga-FAPI in primary tumors (n = 54) and metastatic lesions (n = 229) did not differ (Fig. 1). Subsequently, we analyzed primary and metastatic lesions of individual tumor entities in a pooled fashion.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Neither mean, median, nor range of SUVmax of 68Ga-FAPI-04 PET differs significantly between primary tumors and metastases.

The highest average SUVmax (>12) was found in sarcoma, esophageal, breast, cholangiocarcinoma, and lung cancer. The lowest 68Ga-FAPI uptake (average SUVmax < 6) was observed in renal cell, differentiated thyroid, adenoid cystic, gastric, and pheochromocytoma cancer. The average SUVmax of hepatocellular, colorectal, head–neck, ovarian, pancreatic, and prostate cancer was intermediate (SUV 6–12). All tumor entities exhibited a high interindividual SUV variation (Fig. 2). Because of the low background activity (average SUVmean of blood pool and muscle, 1.2 and 1.0, respectively; SUVmax, 1.6 and 1.4, respectively), the tumor-to-background ratios are more than 3 in the intermediate and more than 6 in the high-intensity uptake group (Fig. 2). These high ratios resulted in high image contrast and excellent tumor delineation in most of the evaluated patients (Fig. 3).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Average SUVmax of 68Ga-FAPI PET/CT in various tumor entities. Low, intermediate, and high uptake was defined by cutoff at SUVs 6 and 12. By comparison, average background (blood pool) was found to have SUV 1.4. Ca = cancer; CCC = cholangiocellular carcinoma; CUP = carcinoma of unknown primary; HCC = hepatocellular carcinoma; NET = neuroendocrine tumor.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Maximum-intensity projections of 68Ga-FAPI PET/CT in patients reflecting 15 different histologically proven tumor entities (sorted by uptake in descending order). Ca = cancer; CCC = cholangiocellular carcinoma; CUP = carcinoma of unknown primary; MTC = medullary thyroid cancer; NET = neuroendocrine tumor.

DISCUSSION

The aim of this retrospective analysis was to quantify the uptake of 68Ga-FAPI ligand in different types of cancer.

The highest uptake (average SUVmax > 12) was found in lung, breast, and esophageal cancer; cholangiocellular carcinoma; and sarcoma. This may open indications for 68Ga-FAPI PET/CT for cases in which 18F-FDG PET/CT faces its limitations. Because of low uptake of 18F-FDG in low-grade sarcomas, there is a wide overlap between benign and malignant lesions, and even dual–time-point imaging could not eliminate this well-known limitation of 18F-FDG PET/CT (8,9). The main limitation of 18F-FDG PET/CT in staging of esophageal cancer is its low to moderate sensitivity for lymph node staging (10) and delineation between viable tumor and regional esophagitis. In breast cancer, 18F-FDG PET/CT is commonly used in recurrence but not generally recommended for initial staging (11). Cholangiocarcinoma exhibits considerable variability in 18F-FDG uptake, which was correlated with a weak expression of hexokinase-2 (12). 18F-FDG PET/CT performs well in lung cancer; however, high cerebral background requires brain MRI for complete staging (13). Thus, these tumors may benefit from 68Ga-FAPI PET/CT imaging. However, the limited number of patients examined by 68Ga-FAPI PET/CT until now does not allow subgroup analysis of histologic variants or differentiation grades.

Surprisingly, colon and pancreatic cancers, that is, the ones with the highest desmoplastic reaction by histopathology (3), demonstrated only intermediate 68Ga-FAPI uptake (SUV 6–12). The liver is the first target organ for metastases of colorectal cancer. We already reported a significantly lower hepatic background for 68Ga-FAPI (SUV 1.7) than for 18F-FDG (SUV 2.8). This may be advantageous for liver metastasis detection (6). Within the patients reported here, we identified liver metastases as small as 1 cm in diameter (Fig. 4). Because of its limited sensitivity of 30% for detecting lymph node metastasis (14) and false-positive findings in acute pancreatitis, 18F-FDG PET is of limited usefulness for surgical planning in pancreatic cancer (15). Thus, even intermediate uptake in 68Ga-FAPI PET/CT presents a reasonable perspective to improve clinical diagnostic performance. In ovarian cancer, another tumor in the intermediate-intensity group, 18F-FDG can overcome some limits of conventional imaging but, because of peristaltic activity, often suffers from heterogeneous uptake in the intestinal wall (16,17). In contrast, 68Ga-FAPI demonstrates very low unspecific intestinal/peritoneal uptake and might be superior to identify peritoneal carcinomatosis, the main clinical challenge of advanced-stage ovarian cancer. Head–neck tumors often go along with local inflammation. Unfortunately, a recent review reported that most original work found that 18F-FDG PET/CT is not useful in discriminating benign from malignant tumors because of the overlap of uptake in both conditions (18–20). In this setting, 68Ga-FAPI PET/CT may offer an advantage regarding tumor delineation—for example, in planning of radiotherapy (Fig. 5). Differentiation between residual/recurrent disease and postchemoradiation fibrosis was reported to be a diagnostic challenge for 18F-FDG (21). It should be mentioned that unspecific fibrosis may also cause issues for 68Ga-FAPI PET; however, because of the inherent difference in normal activated fibroblasts and cancer-associated fibroblasts (4,5), this possibility still needs to be proven. Intermediate to high 68Ga-FAPI uptake was also observed in prostate cancer. However, only patients with prostate-specific membrane antigen–negative tumors, which are the minority of prostate cancers, were selected to receive additional 68Ga-FAPI PET/CT, and because of this selection bias, our cohort does not reflect typical patients.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Maximum-intensity projection (A) of patient with colorectal carcinoma. Because of low physiologic background uptake, tiny lesions in lung (B) and liver (D) were detected by 68Ga-FAPI-04 PET/CT and measured in dedicated CT of lung (C) and hepatic MRI (E) with long-axis diameters of 1 cm. *Primary tumor in left colon flexure. Red arrow = unspecific uptake in uterus.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Among others, one clinical application for 68Ga-FAPI PET/CT can be to improve gross tumor volume delineation in preparation for external-beam radiotherapy—in this case, squamous cell carcinoma of neck with local lymph node metastases. From left to right: whole-body maximum-intensity projections, coronal PET slice through head/neck tumor, its fusion with coregistered CT, PET-segmented target-volume definition for external-beam radiotherapy.

18F-FDG PET often performs poorly in renal cell carcinoma, pheochromocytoma, and neuroendocrine tumors, including medullary thyroid cancer and insulinomas. This limitation is unlikely to be overcome, because SUVs for these tumors are also low for 68Ga-FAPI (average SUVmax < 6). This is likely not a significant problem because several special PET tracers such as 18F-DOPA for neuroblastoma/pheochromocytoma (22), 68Ga-labeled somatostatin analogs for neuroendocrine tumors (23), 89Zr-girentuximab for renal cell carcinoma (24), and 68Ga-exendin targeting glucagonlike peptide-1 receptor on insulinoma (25) recently closed this gap.

The current imaging findings are largely consistent with histopathology reports. FAP expression on activated fibroblasts in tumor stroma was already quantified in 1990 using the antibody-F19 (3). Well in line with our results, a weak desmoblastic reaction was observed in renal cell cancer and neuroblastoma/pheochromocytoma; intermediate staining in pancreatic, gastric, endometrial/cervix cancer; and high expression in breast cancer (3). In contrast to this historical paper, we found a higher 68Ga-FAPI uptake in neuroendocrine tumors (intermediate group in 68Ga-FAPI PET, weak in histology) and lung cancer (high uptake in 68Ga-FAPI PET, intermediate in histology). For colorectal cancer, which was the most commonly high-expressing tumor in the work of Garin-Chesa et al. (3), we only measured intermediate values. Low case numbers, heterogeneity of expression, random effects in tissue sampling, and high interindividual variability appear the most appropriate explanations for these differences between histologic in vitro and imaging in vivo results. Another explanation and also a possible reason for the high interindividual variability can be patient selection. Immunohistochemical work-up has primarily been performed in early-stage nonmetastatic, and thus rather indolent, tumors. In contrast, the patients evaluated by 68Ga-FAPI PET/CT are a more heterogeneous group. Most presented with recurrent and metastatic disease and sometimes (most frequently in colorectal cancer patients) even after several lines of systemic therapy. We also want to emphasize that the aim of this work was only to characterize true-positive lesions (proven by histopathology or unequivocal radiologic findings of histopathologically proven primary tumors), as no acceptable gold standard to rule out false-negative findings was available. Thus, sensitivity and overall diagnostic accuracy cannot be determined.

FAP was considered a promising target for nuclear-labeled tumor probes in 1994. Because of tumor-to-liver ratios of up to 21:1, the antibody 131I-mAb-F19 could delineate liver metastases of colorectal cancer as small as 1 cm in diameter (26). This was confirmed by our observations (Fig. 4) and is supported by earlier data that cancer-associated fibroblasts are already found in lesions above 1–2 mm in diameter (27). However, well in line with typical antibody kinetics, the optimal time for tumor imaging with 131I-mAb-F19 was 3–5 d after administration (26). In contrast, 68Ga-FAPI PET/CT can be performed 10 min to 1 h after administration and, in contrast to 18F-FDG studies, can be done without fasting and resting time (6). This is a potential operational advantage, as observed between prostate-specific membrane antigen targeting with the antibody J591 and an optimal imaging after 6–8 d (28) versus low-molecular-weight prostate-specific membrane antigen ligands that can be imaged 1 h after injection (29).

CONCLUSION

Several epidemiologically important tumor entities, in particular breast, esophagus, lung, pancreatic, head–neck, and colorectal cancer, present with a remarkably high uptake in 68Ga-FAPI PET/CT. This may open new applications for noninvasive tumor characterization and staging examinations. Because the 68Ga-FAPI tracers contain the universal DOTA chelator, also a theranostic approach—after labeling the ligand with an appropriate therapeutic radionuclide—seems feasible. Other known 18F-FDG limitations, for example, in differentiated thyroid and renal cell carcinoma, can probably not be overcome with 68Ga-FAPI. The limitations of this report, such as retrospective evaluation, a heterogeneous patient collective, and a low case number for some kinds of tumor, require further studies.

DISCLOSURE

A patent application for quinoline-based FAP-targeting agents for imaging and therapy in nuclear medicine presents a potential financial conflict of interest for authors Clemens Kratochwil, Thomas Lindner, Walter Mier, Uwe Haberkorn, and Frederik Giesel. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Apr. 6, 2019.

  • © 2019 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Siveke JT
    . Fibroblast-activating protein: targeting the roots of the tumor microenvironment. J Nucl Med. 2018;59:1412–1414.
    OpenUrl
  2. 2.↵
    1. Hamson EJ,
    2. Keane FM,
    3. Tholen S,
    4. Schilling O,
    5. Gorrell MD
    . Understanding fibroblast activation protein (FAP): substrates, activities, expression and targeting for cancer therapy. Proteomics Clin Appl. 2014;8:454–463.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Garin-Chesa P,
    2. Old LJ,
    3. Rettig WJ
    . Cell surface glycoprotein of reactive stromal fibroblasts as a potential antibody target in human epithelial cancers. Proc Natl Acad Sci USA. 1990;87:7235–7239.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Loktev A,
    2. Lindner T,
    3. Mier W,
    4. et al
    . A tumor-imaging method targeting cancer-associated fibroblasts. J Nucl Med. 2018;59:1423–1429.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Lindner T,
    2. Loktev A,
    3. Altmann A,
    4. et al
    . Development of quinoline based theranostic ligands for the targeting of fibroblast activation protein. J Nucl Med. April 6, 2018 [Epub ahead of print].
  6. 6.↵
    1. Giesel F,
    2. Kratochwil C,
    3. Lindner T,
    4. et al
    . 68Ga-FAPI PET/CT: biodistribution and preliminary dosimetry estimate of 2 DOTA-containing FAP-targeting agents in patients with various cancers. J Nucl Med. 2019;60:386–392.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Loktev A,
    2. Lindner T,
    3. Burger EM,
    4. et al
    . Development of novel FAP-targeted radiotracers with improved tumor retention. J Nucl Med. March 8, 2019 [Epub ahead of print].
  8. 8.↵
    1. Parghane RV,
    2. Basu S
    . Dual-time point 18F-FDG-PET and PET/CT for differentiating benign from malignant musculoskeletal lesions: opportunities and limitations. Semin Nucl Med. 2017;47:373–391.
    OpenUrl
  9. 9.↵
    1. Tagliabue L,
    2. Del Sole A
    . Appropriate use of positron emission tomography with [18F]fluorodeoxyglucose for staging of oncology patients. Eur J Intern Med. 2014;25:6–11.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Jiang C,
    2. Chen Y,
    3. Zhu Y,
    4. Xu Y
    . Systematic review and meta-analysis of the accuracy of 18F-FDG PET/CT for detection of regional lymph node metastasis in esophageal squamous cell carcinoma. J Thorac Dis. 2018;10:6066–6076.
    OpenUrl
  11. 11.↵
    1. Caresia Aroztegui AP,
    2. García Vicente AM,
    3. Alvarez Ruiz S,
    4. et al
    . 18F-FDG PET/CT in breast cancer: evidence-based recommendations in initial staging. Tumour Biol. 2017;39:1010428317728285.
    OpenUrl
  12. 12.↵
    1. Paudyal B,
    2. Oriuchi N,
    3. Paudyal P,
    4. et al
    . Clinicopathological presentation of varying 18F-FDG uptake and expression of glucose transporter 1 and hexokinase II in cases of hepatocellular carcinoma and cholangiocellular carcinoma. Ann Nucl Med. 2008;22:83–86.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Flechsig P,
    2. Mehndiratta A,
    3. Haberkorn U,
    4. Kratochwil C,
    5. Giesel FL
    . PET/MRI and PET/CT in lung lesions and thoracic malignancies. Semin Nucl Med. 2015;45:268–281.
    OpenUrl
  14. 14.↵
    1. Kauhanen SP,
    2. Komar G,
    3. Seppänen MP,
    4. et al
    . A prospective diagnostic accuracy study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography, multidetector row computed tomography, and magnetic resonance imaging in primary diagnosis and staging of pancreatic cancer. Ann Surg. 2009;250:957–963.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Strobel O,
    2. Büchler MW
    . Pancreatic cancer: FDG-PET is not useful in early pancreatic cancer diagnosis. Nat Rev Gastroenterol Hepatol. 2013;10:203–205.
    OpenUrl
  16. 16.↵
    1. Marzola MC,
    2. Chondrogiannis S,
    3. Rubello D
    . Fludeoxyglucose F 18 PET/CT assessment of ovarian cancer. PET Clin. 2018;13:179–202.
    OpenUrl
  17. 17.↵
    1. Kitajima K,
    2. Murakami K,
    3. Sakamoto S,
    4. Kaji Y,
    5. Sugimura K
    . Present and future of FDG-PET/CT in ovarian cancer. Ann Nucl Med. 2011;25:155–164.
    OpenUrlPubMed
  18. 18.↵
    1. Bertagna F,
    2. Nicolai P,
    3. Maroldi R,
    4. et al
    . Diagnostic role of 18F-FDG-PET or PET/CT in salivary gland tumors: a systematic review. Rev Esp Med Nucl Imagen Mol. 2015;34:295–302.
    OpenUrl
  19. 19.
    1. Zafereo ME
    . Evaluation and staging of squamous cell carcinoma of the oral cavity and oropharynx: limitations despite technological breakthroughs. Otolaryngol Clin North Am. 2013;46:599–613.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Plaxton NA,
    2. Brandon DC,
    3. Corey AS,
    4. et al
    . Characteristics and limitations of FDG PET/CT for imaging of squamous cell carcinoma of the head and neck: a comprehensive review of anatomy, metastatic pathways, and image findings. AJR. 2015;205:W519–W531.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. Lai V,
    2. Khong PL
    . Updates on MR imaging and 18F-FDG PET/CT imaging in nasopharyngeal carcinoma. Oral Oncol. 2014;50:539–548.
    OpenUrl
  22. 22.↵
    1. Amodru V,
    2. Guerin C,
    3. Delcourt S,
    4. et al
    . Quantitative 18F-DOPA PET/CT in pheochromocytoma: the relationship between tumor secretion and its biochemical phenotype. Eur J Nucl Med Mol Imaging. 2018;45:278–282.
    OpenUrl
  23. 23.↵
    1. Barrio M,
    2. Czernin J,
    3. Fanti S,
    4. et al
    . The impact of somatostatin receptor-directed PET/CT on the management of patients with neuroendocrine tumor: a systematic review and meta-analysis. J Nucl Med. 2017;58:756–761.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Hekman MCH,
    2. Rijpkema M,
    3. Aarntzen EH,
    4. et al
    . Positron emission tomography/computed tomography with 89Zr-girentuximab can aid in diagnostic dilemmas of clear cell renal cell carcinoma suspicion. Eur Urol. 2018;74:257–260.
    OpenUrl
  25. 25.↵
    1. Antwi K,
    2. Fani M,
    3. Heye T,
    4. et al
    . Comparison of glucagon-like peptide-1 receptor (GLP-1R) PET/CT, SPECT/CT and 3T MRI for the localisation of occult insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study. Eur J Nucl Med Mol Imaging. 2018;45:2318–2327.
    OpenUrl
  26. 26.↵
    1. Welt S,
    2. Divgi CR,
    3. Scott AM,
    4. et al
    . Antibody targeting in metastatic colon cancer: a phase I study of monoclonal antibody F19 against a cell-surface protein of reactive tumor stromal fibroblasts. J Clin Oncol. 1994;12:1193–1203.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Davidson B,
    2. Goldberg I,
    3. Kopolovic J
    . Inflammatory response in cervical intraepithelial neoplasia and squamous cell carcinoma of the uterine cervix. Pathol Res Pract. 1997;193:491–495.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Pandit-Taskar N,
    2. O’Donoghue JA,
    3. Beylergil V,
    4. et al
    . 89Zr-huJ591 immuno-PET imaging in patients with advanced metastatic prostate cancer. Eur J Nucl Med Mol Imaging. 2014;41:2093–2105.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Afshar-Oromieh A,
    2. Hetzheim H,
    3. Kübler W,
    4. et al
    . Radiation dosimetry of 68Ga-PSMA-11 (HBED-CC) and preliminary evaluation of optimal imaging timing. Eur J Nucl Med Mol Imaging. 2016;43:1611–1620.
    OpenUrlCrossRefPubMed
  • Received for publication March 5, 2019.
  • Accepted for publication March 19, 2019.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 60 (6)
Journal of Nuclear Medicine
Vol. 60, Issue 6
June 1, 2019
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer
Clemens Kratochwil, Paul Flechsig, Thomas Lindner, Labidi Abderrahim, Annette Altmann, Walter Mier, Sebastian Adeberg, Hendrik Rathke, Manuel Röhrich, Hauke Winter, Peter K. Plinkert, Frederik Marme, Matthias Lang, Hans-Ulrich Kauczor, Dirk Jäger, Jürgen Debus, Uwe Haberkorn, Frederik L. Giesel
Journal of Nuclear Medicine Jun 2019, 60 (6) 801-805; DOI: 10.2967/jnumed.119.227967

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer
Clemens Kratochwil, Paul Flechsig, Thomas Lindner, Labidi Abderrahim, Annette Altmann, Walter Mier, Sebastian Adeberg, Hendrik Rathke, Manuel Röhrich, Hauke Winter, Peter K. Plinkert, Frederik Marme, Matthias Lang, Hans-Ulrich Kauczor, Dirk Jäger, Jürgen Debus, Uwe Haberkorn, Frederik L. Giesel
Journal of Nuclear Medicine Jun 2019, 60 (6) 801-805; DOI: 10.2967/jnumed.119.227967
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Diagnostic Radiopharmaceutical Trial Design: Is It Time to Change Nomenclature?
  • 18F-FAPI PET/CT Imaging in Pneumoconiosis: a new tool for early diagnosis and guiding treatment of pulmonary fibrosis
  • Comparison of [68Ga]Ga-Fibroblast Activation Protein Inhibitor-04 and [18F]FDG PET Imaging for Solitary Fibrous Tumor and Preliminary Application of FAP-Targeted Radiopharmaceutical Therapy
  • Are FAP Theranostics Really Happening? Will Radiochemistry or Biology Win?
  • Preclinical Evaluation of 68Ga/177Lu-Labeled FAP-Targeted Peptide for Tumor Radiopharmaceutical Imaging and Therapy
  • PD-1 cis-targeted IL-2v in combination with radiotherapy inhibits lung cancer growth and remodels the immune microenvironment
  • Development of FAP-targeted theranostics discovered by next-generation sequencing-augmented mining of a novel immunized VNAR library
  • SNMMI Procedure Standard/EANM Practice Guideline for Fibroblast Activation Protein (FAP) PET
  • [18F]FDG and [68Ga]Ga-FAPI-04-Directed Imaging for Outcome Prediction in Patients with High-Grade Neuroendocrine Neoplasms
  • Addressing Biological Questions with Preclinical Cancer Imaging
  • 1,090 Publications and 5 Years Later: Is FAP-Targeted Theranostics Really Happening?
  • Optimizing the Therapeutic Index of sdAb-Based Radiopharmaceuticals Using Pretargeting
  • The Role of Fibroblast Activation Protein in Glioblastoma and Gliosarcoma: A Comparison of Tissue, 68Ga-FAPI-46 PET Data, and Survival Data
  • Design of a Fibroblast Activation Protein-Targeted Radiopharmaceutical Therapy with High Tumor-to-Healthy-Tissue Ratios
  • 68Ga-Fibroblast Activation Protein Inhibitor PET/CT Improves Detection of Intermediate and Low-Grade Sarcomas and Identifies Candidates for Radiopharmaceutical Therapy
  • 68Ga-FAP-2286 PET of Solid Tumors: Biodistribution, Dosimetry, and Comparison with 18F-FDG
  • Diagnostic Potential of Supplemental Static and Dynamic 68Ga-FAPI-46 PET for Primary 18F-FDG-Negative Pulmonary Lesions
  • A Systematic Review on the Diagnostic Value of Fibroblast Activation Protein Inhibitor PET/CT in Genitourinary Cancers
  • Overexpression of Fibroblast Activation Protein (FAP) in stroma of proliferative inflammatory atrophy (PIA) and primary adenocarcinoma of the prostate
  • 68Ga-FAPI-04 PET/CT in Non-Small Cell Lung Cancer: Accurate Evaluation of Lymph Node Metastasis and Correlation with Fibroblast Activation Protein Expression
  • 68Ga-FAPI PET/CT as an Alternative to 18F-FDG PET/CT in the Imaging of Invasive Lobular Breast Carcinoma
  • Imaging of Tumor Stroma Using 68Ga-FAPI PET/CT to Improve Diagnostic Accuracy of Primary Tumors in Head and Neck Cancer of Unknown Primary: A Comparative Imaging Trial
  • Design, Preclinical Evaluation, and Clinical Translation of 68Ga-FAPI-LM3, a Heterobivalent Molecule for PET Imaging of Nasopharyngeal Carcinoma
  • The Current and Future Roles of Precision Oncology in Advanced Breast Cancer
  • Diagnostic Accuracy of 68Ga-FAPI Versus 18F-FDG PET in Patients with Various Malignancies
  • Metabolic and molecular imaging in inflammatory arthritis
  • Fibroblast Activation Protein {alpha}-Directed Imaging and Therapy of Solitary Fibrous Tumor
  • Initial Experience with 68Ga-FAP-2286 PET Imaging in Patients with Urothelial Cancer
  • Imaging Agents for PET of Inflammatory Bowel Disease: A Review
  • Oncologic Staging with 68Ga-FAPI PET/CT Demonstrates a Lower Rate of Nonspecific Lymph Node Findings Than 18F-FDG PET/CT
  • Impact of 68Ga-FAPI PET/CT on Staging and Oncologic Management in a Cohort of 226 Patients with Various Cancers
  • PET imaging of fibroblast activation protein alpha (FAP) detects incipient cardiotoxicity due to anthracycline chemotherapy
  • Fibroblast Activation Protein and Glycolysis in Lymphoma Diagnosis: Comparison of 68Ga-FAPI PET/CT and 18F-FDG PET/CT
  • Performance of 68Ga-Labeled Fibroblast Activation Protein Inhibitor PET/CT in Evaluation of Erdheim-Chester Disease: A Comparison with 18F-FDG PET/CT
  • Development of FAPI Tetramers to Improve Tumor Uptake and Efficacy of FAPI Radioligand Therapy
  • Initial Evaluation of [18F]FAPI-74 PET for Various Histopathologically Confirmed Cancers and Benign Lesions
  • Molecular Imaging of Myocardial Fibroblast Activation in Patients with Advanced Aortic Stenosis Before Transcatheter Aortic Valve Replacement: A Pilot Study
  • Clinical Evaluation of 68Ga-FAPI-RGD for Imaging of Fibroblast Activation Protein and Integrin {alpha}v{beta}3 in Various Cancer Types
  • Tumor Characterization by [68Ga]FAPI-46 PET/CT Can Improve Treatment Selection for Pancreatic Cancer Patients: An Interim Analysis of a Prospective Clinical Trial
  • Development of FAPI Tetramers to Improve Tumor Uptake and Efficacy of FAPI Radioligand Therapy
  • Molecular Imaging of Myocardial Fibroblast Activation in Patients with Advanced Aortic Stenosis Before Transcatheter Aortic Valve Replacement: A Pilot Study
  • Initial Evaluation of [18F]FAPI-74 PET for Various Histopathologically Confirmed Cancers and Benign Lesions
  • Fibroblast Activation Protein Inhibitor-Based Radionuclide Therapies: Current Status and Future Directions
  • 18F-FDG PET/CT in the Management of Osteosarcoma
  • 68Ga-FAPI PET/CT Interobserver Agreement on Tumor Assessment: An International Multicenter Prospective Study
  • 18F-FDG PET/CT in the Management of Osteosarcoma
  • Clinical Evaluation of 68Ga-FAPI-RGD for Imaging of Fibroblast Activation Protein and Integrin {alpha}v{beta}3 in Various Cancer Types
  • Fibroblast-Activation Protein PET and Histopathology in a Single-Center Database of 324 Patients and 21 Tumor Entities
  • Fibroblast Activation Protein-Targeted Radioligand Therapy for Treatment of Solid Tumors
  • Three-Time-Point PET Analysis of 68Ga-FAPI-46 in a Variety of Cancers
  • PET Imaging of Fibroblast Activation Protein in Various Types of Cancer Using 68Ga-FAP-2286: Comparison with 18F-FDG and 68Ga-FAPI-46 in a Single-Center, Prospective Study
  • Static and Dynamic 68Ga-FAPI PET/CT for the Detection of Malignant Transformation of Intraductal Papillary Mucinous Neoplasia of the Pancreas
  • Spontaneous, naturally occurring cancers in non-human primates as a translational model for cancer immunotherapy
  • FAP-retargeted Ad5 enables in vivo gene delivery to stromal cells in the tumor microenvironment
  • Fibroblast Activation Protein Inhibitor Imaging in Nonmalignant Diseases: A New Perspective for Molecular Imaging
  • A Dimeric FAP-Targeting Small-Molecule Radioconjugate with High and Prolonged Tumor Uptake
  • Repetitive Early 68Ga-FAPI PET Acquisition Comparing 68Ga-FAPI-02, 68Ga-FAPI-46, and 68Ga-FAPI-74: Methodologic and Diagnostic Implications for Malignant, Inflammatory/Reactive, and Degenerative Lesions
  • Staging Liver Fibrosis by Fibroblast Activation Protein Inhibitor PET in a Human-Sized Swine Model
  • Dual-Tracer PET/CT Protocol with [18F]-FDG and [68Ga]Ga-FAPI-46 for Cancer Imaging: A Proof of Concept
  • Generation and in vivo validation of an IL-12 fusion protein based on a novel anti-human FAP monoclonal antibody
  • Cardiac Fibroblast Activation in Patients Early After Acute Myocardial Infarction: Integration with MR Tissue Characterization and Subsequent Functional Outcome
  • Head-to-Head Comparison of 68Ga-FAPI-46 and 18F-FDG PET/CT for Evaluation of Head and Neck Squamous Cell Carcinoma: A Single-Center Exploratory Study
  • Correlation of 68Ga-FAPi-46 PET Biodistribution with FAP Expression by Immunohistochemistry in Patients with Solid Cancers: Interim Analysis of a Prospective Translational Exploratory Study
  • Pitfalls and Common Findings in 68Ga-FAPI PET: A Pictorial Analysis
  • The Added Value of 68Ga-FAPI PET/CT in Patients with Head and Neck Cancer of Unknown Primary with 18F-FDG-Negative Findings
  • Albumin Binder-Conjugated Fibroblast Activation Protein Inhibitor Radiopharmaceuticals for Cancer Therapy
  • Initial Clinical Experience with 90Y-FAPI-46 Radioligand Therapy for Advanced-Stage Solid Tumors: A Case Series of 9 Patients
  • A mass spectrometry-based method for the determination of in vivo biodistribution of tumor targeting small molecule-metal conjugates
  • Feasibility, Biodistribution, and Preliminary Dosimetry in Peptide-Targeted Radionuclide Therapy of Diverse Adenocarcinomas Using 177Lu-FAP-2286: First-in-Humans Results
  • A novel dimeric FAP-targeting small molecule-radio conjugate with high and prolonged tumour uptake
  • Detecting Fibroblast Activation Proteins in Lymphoma Using 68Ga-FAPI PET/CT
  • 68Ga-DOTA-FAPI-04 PET/MR in the Evaluation of Gastric Carcinomas: Comparison with 18F-FDG PET/CT
  • Fibroblast Activation Protein-Specific PET/CT Imaging in Fibrotic Interstitial Lung Diseases and Lung Cancer: A Translational Exploratory Study
  • Imaging the Inflammatory Response in Checkpoint Inhibition Myocarditis
  • 68Ga-FAPI as a Diagnostic Tool in Sarcoma: Data from the 68Ga-FAPI PET Prospective Observational Trial
  • Google Scholar

More in this TOC Section

Theranostics

  • Determination of the Intralesional Distribution of Theranostic 124I-Omburtamab Convection-Enhanced Delivery in Treatment of Diffuse Intrinsic Pontine Glioma
  • Evidence-Based Clinical Protocols to Monitor Efficacy of [177Lu]Lu-PSMA Radiopharmaceutical Therapy in Metastatic Castration-Resistant Prostate Cancer Using Real-World Data
  • 177Lu-Labeled Anticlaudin 6 Monoclonal Antibody for Targeted Therapy in Esophageal Cancer
Show more Theranostics

Clinical

  • Detection of Early Progression with 18F-DCFPyL PET/CT in Men with Metastatic Castration-Resistant Prostate Cancer Receiving Bipolar Androgen Therapy
  • TauIQ: A Canonical Image Based Algorithm to Quantify Tau PET Scans
  • Dual PET Imaging in Bronchial Neuroendocrine Neoplasms: The NETPET Score as a Prognostic Biomarker
Show more Clinical

Similar Articles

Keywords

  • FAPI
  • breast cancer
  • colorectal cancer
  • lung cancer
  • PET/CT
SNMMI

© 2025 SNMMI

Powered by HighWire