Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Practice of Molecular Radiotherapy

Patient-Specific Dosimetry in Predicting Renal Toxicity with 90Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose–Effect Relationship

Raffaella Barone, Françoise Borson-Chazot, Roelf Valkema, Stéphan Walrand, Franck Chauvin, Lida Gogou, Larry K. Kvols, Eric P. Krenning, François Jamar and Stanislas Pauwels
Journal of Nuclear Medicine January 2005, 46 (1 suppl) 99S-106S;
Raffaella Barone
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Françoise Borson-Chazot
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Roelf Valkema
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stéphan Walrand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Franck Chauvin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lida Gogou
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Larry K. Kvols
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eric P. Krenning
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
François Jamar
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stanislas Pauwels
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Nephrotoxicity is the major limiting factor during therapy with the radiolabeled somatostatin analog 90Y-1,4,7,10-tetraazacyclododecane-N,N′,N″,N‴-tetraacetic acid (DOTA)-d-Phe1-Tyr3-octreotide (DOTATOC). Pretherapeutic assessment of kidney absorbed dose could help to minimize the risk of renal toxicity. The aim of this study was to evaluate the contribution of patient-specific adjustments to the standard dosimetric models, such as the renal volume and dose rate, for estimating renal absorbed dose during therapy with 90Y-DOTATOC. In particular, we investigated the correlation between dose estimates and effect on renal function after therapy. Methods: Eighteen patients with neuroendocrine tumors (9 men and 9 women; median age, 59 y) underwent treatment with 90Y-DOTATOC (8.1–22.9 GBq) after pretherapeutic biodistribution study with 86Y-DOTATOC. Kidney uptake and residence times were measured and the absorbed dose (KAD) was computed using either the MIRDOSE3.1 software assuming a standard kidney volume (KADStdVol) or the MIRD Pamphlet 19 values and the actual kidney cortex volume determined by pretherapeutic CT (KADCTVol). For each patient, the biologic effective dose (BED) was calculated according to the linear quadratic model to take into account the effect of dose rate and fractionation. Renal function was evaluated every 6 mo by serum creatinine and creatinine clearance (CLR) during a median follow-up of 35.5 mo (range, 18–65 mo). The individual rate of decline of renal function was expressed as CLR loss per year. Results: KADCTVol ranged between 19.4 and 39.6 Gy (mean, 28.9 ± 5.34 Gy). BED, obtained from KADCTVol, ranged between 27.7 and 59.3 Gy (mean, 40.4 ± 10.6 Gy). The CLR loss per year ranged from 0% to 56.4%. In 12 of 18 patients, CLR loss per year was <20%. No correlation was observed between CLR loss per year and the KADStdVol or the KADCTVol. In contrast, BED strongly correlated with CLR loss per year (r = 0.93; P < 0.0001). All 5 patients with CLR loss per year >20% received a BED >45 Gy. Patients who were treated with low fractionation were those with the highest rate of renal function impairment. Conclusion: Radiation nephrotoxicity after 90Y-DOTATOC therapy is dose dependent. Individual renal volume, dose rate, and fractionation play important roles in an accurate dosimetry estimation that enables prediction of risk of renal function impairment.

  • kidney dosimetry
  • 90Y-DOTA-Tyr3-octreotide
  • radionuclide therapy
  • radiation nephropathy

Peptide receptor radionuclide therapy (PRRT) using radiolabeled somatostatin analogs appears to be promising for the treatment of somatostatin receptor–positive neuroendocrine tumors (1–3). In patients who are untreatable by other conventional methods, favorable clinical responses were obtained with 1,4,7,10-tetraazacyclododecane-N,N′,N″,N‴-tetraacetic acid (DOTA)-d-Phe1-Tyr3-octreotide (DOTATOC) labeled with 90Y, a high-energy β-emitter (2–7). Because a clear dose–response relationship was shown between reduction in tumor volume and tumor radiation dose, the challenge is to deliver the highest activity to the tumor while sparing normal tissues (8,9). Recent biodistribution studies and clinical trials showed that the kidney is a major critical organ for PRRT with 90Y-DOTATOC (10–17). The radiolabeled peptide is rapidly cleared from the circulation by the kidneys and, after filtration by the glomeruli, is reabsorbed and retained into the proximal tubular cells. Renal toxicity after treatment was reported in 6 cases (13–17). In the largest published series, Otte et al. (13) reported 4 cases with renal damage among 29 patients treated. Radiation-induced thrombotic microangiopathy was identified on kidney biopsy samples.

Several factors could be involved in renal damage, among which absorbed dose to kidneys is likely to play a key role. With fractionated external beam radiotherapy, the dose resulting in a 5% probability of developing radiation nephropathy within 5 y was found to be 23 Gy (18). However, in PRRT, where the dose rate is much lower and the radiation delivered to organs is inhomogeneous, the critical dose may be higher and has not yet been determined (19).

Because of the large variability in individual renal uptake of 90Y-DOTATOC, some patients could potentially receive critical kidney doses, particularly if high activities are administered to deliver the most effective tumor doses (10). Therefore, in a recent therapeutic trial with 90Y-DOTATOC, we implemented a patient-specific therapeutic regimen approach. Individual activities administered were based on a pretherapeutic absorbed dose estimate using 86Y-DOTATOC for quantitative kidney imaging and the MIRDOSE3.1 model (20). On the basis of these individual absorbed dose estimations, the administered activities were calculated to deliver a cumulative absorbed dose to the kidneys close to 27 Gy. In spite of the fact that the treatment was planned to deliver a similar absorbed dose to each patient, a wide interpatient difference in kidney side effects was observed during follow-up. These findings suggest that either the absorbed dose alone would not predict response or that conventional dosimetry analyses, based on stylized formalisms, are oversimplified and thus lack the accuracy needed to be valid predictors of toxicity. This retrospective study was undertaken in a subset of those patients to evaluate whether implementation of a more refined absorbed dose estimation method, including adjustments for the actual volume of the irradiated organ and the dose rate effect, would result in greater clinical relevance.

MATERIALS AND METHODS

Study Design and Patients

The study group represented a subset of patients with neuroendocrine tumors, enrolled in a phase 1 multicenter study intended to establish the 1-cycle and multiple-cycle maximum tolerated doses of 90Y-DOTATOC (Novartis Pharma AG) in patients with metastatic, somatostatin-receptor positive tumors (21). The study was approved by the Ethics Committee of the University of Louvain Medical School, and all patients gave written informed consent.

This retrospective study was restricted to patients with gastroenteropancreatic tumors in whom pretherapeutic abdominal CT allowed accurate determination of kidney volume and who were followed up for at least 18 mo. Clinical characteristics are summarized in Table 1. The study included 9 women and 9 men (ages, 41–75 y; mean, 57.2 ± 8.9 y) with histologically confirmed tumor(s) and positive 111In-pentetreotide (OctreoScan111; Tyco Healthcare) imaging. Disease extent was assessed by CT. Three patients had undergone previous chemotherapy more than 6 mo before PRRT, 4 were diabetic, and 4 were hypertensive. Each patient underwent pretherapeutic biodistribution and pharmacokinetic studies with 86Y-DOTATOC PET to measure individual kidney uptake and estimate 90Y-labeled analog renal absorbed doses during therapy (10). This study allowed individualized treatment of patients with cumulative activities that would not exceed the safety threshold of 27 Gy to kidney. All 18 patients were subsequently treated, under amino acid infusion, with 90Y-DOTATOC (21). The median follow-up was 35.5 mo (range, 18.0–65.4 mo).

View this table:
  • View inline
  • View popup
TABLE 1

Patients and Treatment Characteristics

Assessment of Renal Function

During follow-up, kidney function was assessed every 6 mo by serum creatinine and by creatinine clearance (CLR). Measured CLR was determined based on 2 24-h urine collections and serum creatinine assessment. This method is prone to sampling errors and may vary by 10%–20% from day to day. During follow-up, changes in CLR were assessed by estimated CLR using the Cockcroft–Gault formula: MathEq. 1 for men, multiplied by 0.85 for women (22). At baseline, we calculated the ratio between true CLR and the estimated CLR for each patient. All subsequent estimated CLR values were multiplied by this factor to yield CLR.

The kidney is an organ with a slow cellular turnover, and radiation-induced functional damage appears with a substantial delay. It is therefore important to observe renal function over a long period of time to assess the long-term risk of clinically relevant loss of function. Because the follow-up duration varied for each patient in this study, we evaluated individual rates of decline of renal function, expressed as CLR loss per year. To determine the percentage change in CLR per year, a monoexponential curve was fitted through the CLR data of each patient, from the start of treatment onward (23).

Kidney Volume Determination from CT Scan

Kidney volume was retrospectively measured (by an individual unaware of patient characteristics) on pretherapeutic CT scan by drawing regions of interest (ROIs) on consecutive transverse slices including the whole kidneys and the intrarenal part of the collecting system. Intra- and interobserver coefficients of variation were 3.4% and 3.8%, respectively. In this study, the same observer performed all measurements. In 12 patients, kidney volume was also measured on CT scans obtained at the end of treatment to evaluate the effect of treatment on kidney volume. We assumed that the renal cortex accounted for 70% of total kidney volume (24).

Estimation of Kidney Absorbed Dose Using 86Y-DOTATOC PET Imaging

Tracers and Reagents.

DOTATOC (Novartis Pharma AG) was available as a lyophilized kit. 86Y was produced by irradiation of enriched 86SrCO3 (Oak Ridge National Laboratory [ORNL]) after an 86Sr(p,n)86Y reaction (25). Radiolabeling was performed as previously described (10). The final injected activity was 286 ± 119 MBq. The study was performed with co-infusion of mixed amino acids (10). A commercially available amino acid solution was used: 1,500 mL Proteinsteril Hepa 8% (Fresenius) containing 10.72 g l-arginine and 6.88 g l-lysine per liter together with other essential and nonessential amino acids, was brought to 1,800 mL by addition of 300 mL lactated Ringer’s solution (Hartmann; Travenol Laboratories). The total l-arginine + l-lysine amount was 26.4 g. This solution was infused over 4 h, starting 30 min before 86Y-DOTATOC. The same renal protection regimen was applied for 90Y-DOTATOC treatment.

86Y-DOTATOC Biodistribution.

86Y-DOTATOC PET was performed at 3.5, 24, and 48 h after injection. A transmission scan using rotating-rod 68Ge sources was acquired before injection. The camera used was an ECAT EXACT HR tomograph (Siemens–CTI) (26), operated in two-dimensional mode (i.e., with septa extended). Ten overlapping 5-min bed positions (15 cm, 2.5 cm overlap) were acquired at 3.5 h. At 24 and 48 h only, 3–6 positions were acquired on the main field of interest for a total duration of 60 min. The scans were reconstructed by iterative processing (OSEM) in a 128 × 128 matrix (pixel size, 4.3 mm), with decay and attenuation corrections as well as correction for spurious photon contamination arising from the high-energy γ-emissions of 86Y (27,28). A noise filter of 9-mm spatial resolution was applied.

Data Processing.

For quantification of kidney radioactivity uptake, ROIs were drawn plane by plane on all transverse consecutive PET slices, and the activity was expressed as a percentage of injected activity. In patient 14, the upper pole of the left kidney could not be accurately delineated because of overlying tumor activity. The initial quantification was performed assuming that the total uptake of the left kidney was equal to the uptake measured in its lower part, corrected for the total volume of the right kidney, and that both kidneys had similar volumes. When we reanalyzed data for this report, we found in patient 14 a larger difference between the volumes of the 2 kidneys, and, therefore, we corrected the quantitative uptake data, taking into account the actual CT volume of the left kidney.

Residence time in kidneys was calculated from uptake measurements. Linear fitting was used between 4 and 24 h and extrapolated to time 0. Washout curves were fitted to a monoexponential function between 24 and 48 h and applied onward. The effective half-life of 90Y-DOTATOC (T1/2eff) was also estimated. Residence time values were input into the MIRDOSE3.1 program to calculate dosimetry estimates for 90Y-DOTATOC in a reference man or woman. Kidney cortex radiation doses were also computed by rescaling the individual dose obtained from MIRD Pamphlet 19 using the ratio between standard kidney volume (288 mL) and the actual renal cortex volume, assuming that cortex volume accounted for 70% of the total kidney CT estimate (24). S factors given by MIRD Pamphlet 19 account for energy loss in the kidney medulla from the cortex, thereby providing a more accurate calculation of the dose to the cortex.

Calculation of Biologic Effective Dose Using the Linear–Quadratic Model

The linear–quadratic (LQ) model describes the surviving fraction (S) of target cells after a radiation dose (D): MathEq. 2 where the linear component αD describes the double-strand breaks induced by a single ionizing event, and the quadratic component βD2 describes the same effect induced by 2 separate ionizing events.

This model applied to a therapeutic dose delivered over a period of time and fractionated in multiple cycles gives an estimation of the biologic effective dose (BED) (19): MathEq. 3 where Di is the dose delivered for cycle i; T1/2eff is the effective half-life of 90Y-DOTATOC based on 86Y-DOTATOC individual biodistribution data; and T1/2rep is the repair half-time of sublethal damage.

It should be pointed out that the nonlinearity of Equation 3 requires that dose Di be the absolute amount of energy delivered per mass unit of tissue.

We assumed that T1/2rep = 2.8 h and α/β = 2.6 Gy, as reported in the literature (29).

90Y-DOTATOC Administration Protocol

Patients were treated in the framework of a phase 1 dose-escalation study aiming to evaluate the safety of 90Y-DOTATOC (21). The treatment consisted of a single or multiple cycles given at 6- to 9-wk intervals. Dose escalation proceeded in both a vertical and horizontal manner. As mentioned previously, the individual treatment regimen was planned aiming not to exceed the safety threshold of 27 Gy to kidney. Individual activities administered and the number of therapeutic cycles are listed in Table 1. The number of cycles varied from 1 to 5. The median cumulated activity administered was 14.0 GBq, ranging between 8.1 and 22.9 GBq. Total renal absorbed dose, estimated from MIRDOSE3.1, ranged from 25.6 to 38.6 Gy (median, 27.1 Gy) (Table 2). In 2 patients, renal absorbed dose exceeded 27 Gy because of an extra-cycle 90Y-DOTATOC administration (patients 11 and 16). In patient 14, the estimated renal absorbed dose increased from 27.1 to 38.6 Gy according to the calculations described here.

View this table:
  • View inline
  • View popup
TABLE 2

Individual Estimates of Absorbed Dose to Kidneys

Analysis

Results are presented as mean and SD of the mean. The 2-sample paired and unpaired Student t tests were used for group comparisons. The statistical significance of the difference in all comparisons was based on 1-tailed 5% α-error. Correlations between the percentage of change in renal function parameters and the cumulated absorbed dose were fitted by using a modified power exponential function: MathEq. 4 where F is the function to be fitted and D is the kidney absorbed dose or the BED.

This formula describes well the absence of alteration for low doses (parameter b) followed by a fast increase (parameter a). Correlation r and significance P were derived from this fit.

RESULTS

Renal Function

As shown in Table 3, renal function was normal before treatment in all patients. After treatment, for the whole group, the mean CLR loss per year was 15.3%, ranging from 0% to 56.4%. CLR loss per year was less than 10% in 12 of 18 patients and exceeded 20% in patients 2, 8, 9, 10, and 14. During follow-up, these 5 patients exhibited a sustained and progressive increase in serum creatinine (ranging from 50% to 322%) together with a decrease in estimated CLR (ranging from 36% to 78%). In patients 2 and 9, the occurrence of proteinuria, hypertension, and edema, together with anemia and a dramatic decrease in serum haptoglobin, demonstrated radiation-induced microangiopathy. The diagnosis was biopsy-proven in patient 2. Among the 5 patients who presented major CLR loss per year, patient 14 was diabetic, with preexisting hypertension and previous chemotherapy, and patients 2 and 10 were hypertensive at baseline.

View this table:
  • View inline
  • View popup
TABLE 3

Evolution of Renal Function

Patient 1, who also had preexisting hypertension, showed an intermediate rate of CLR loss (14%/y). However, during a 5-y follow-up she exhibited a progressive deterioration of renal function, leading to 49% CLR reduction at the last control. In addition to patient 14, the 2 other patients (6 and 13) who had undergone chemotherapy did not exhibit marked renal function decline during follow-up (CLR losses per year of 2.8% and 4.4%, respectively).

Kidney Volume

As shown in Table 2, there was wide variability in kidney volumes, from 231 to 503 mL. Mean kidney volume differed between males and females (372.8 ± 75.5 and 317.2 ± 59.1 mL, respectively). In all except 2 patients, kidney volume was larger than the standard ORNL phantom (i.e., the volume used to compute the dose in the MIRDOSE3.1: 288.0 mL in males and 264.4 mL in females) (Fig. 1). Patients 2 and 9, who had renal volumes smaller than the standard volume, were the same patients who demonstrated radiation-induced microangiopathy. Kidney volumes were unchanged before and after therapy.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Individual kidney volumes measured by CT, in males (n = 9) and females (n = 9). Dotted lines represent standard ORNL phantom values (288 mL in males, 264 mL in females), and continuous lines represent median kidney volumes obtained from CT (365 mL in males, 302 mL in females). Filled circles represent patients with CLR loss per year >20%.

Estimation of Kidney Absorbed Dose

The median kidney uptakes of 86Y-DOTATOC at 4, 24, and 48 h were 1.90%, 2.01%, and 1.54%, respectively. Median residence time was 1.09 h, ranging between 0.65 and 2 h. Assuming a standard kidney volume, the median kidney absorbed dose estimated from individual PET data was 2.05 mGy/MBq, ranging between 1.18 and 3.60 mGy/MBq (Fig. 2). Taking into account the therapeutic administered activities, the individual kidney absorbed dose assuming a standard volume (KADStdVol) ranged between 25.6 and 38.6 Gy (Table 2). There was no difference between males and females, and no correlation with age or kidney volume was observed.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Individual kidney absorbed dose of 90Y-DOTATOC, using 86Y-DOTATOC quantitative imaging. MIRDOSE3.1 was used for dosimetric calculations. Data are reported for males (n = 9) and females (n = 9). The continuous line represents median kidney dose in each group. Filled circles represent patients with CLR loss per year >20%.

Kidney dose computation using MIRD Pamphlet 19 and CT-measured kidney cortex volumes (KADCTVol), instead of MIRDOSE3.1 and standard volumes, resulted in a wider range of dose estimates (19.4–39.6 Gy) (Table 2).

Finally, taking into account the biologic effect of dose fractionation, the mean BED), obtained from KADCTVol, was 40.4 ± 10.6 Gy, ranging from 27.7 to 59.2 Gy.

Correlation Between Kidney Dose and Renal Function

No relationship was observed between CLR loss per year and KADStdVol or KADCTVol (Figs. 3A and 3B). In contrast, BED strongly correlated with CLR loss per year (r = 0.93; P < 0.0001). As shown in Figure 3C, this relationship was well adjusted to the modified power exponential function (Eq. 4). Indeed, a clear cutoff can be observed between the 5 patients with substantial impairment of kidney function (CLR loss per year >20%) and the other patients. In addition, it is noteworthy that the 5 patients with high BED and pronounced kidney side effects were treated with a relatively small number of therapeutic cycles (Table 1 and Fig. 3C). A similar relationship was obtained between BED and the percentage of CLR change observed at 18 mo after therapy (Fig. 3D).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Correlation between KAD or BED, and the loss in CLR. (A) KADStdVol computed by MIRDOSE3.1 KADStdVol. (B) KADCTVol computed by MIRD Pamphlet 19. (C) Correlation between BED and current CLR loss per year. (D) Correlation between BED and percentage of CLR loss after 18-mo follow-up. Size of symbols reflects number of treatment cycles received by each patient (from 1 for smallest to 5 for largest). Points were fitted to power exponential function (see Eq. 4 in text). In C, note clear difference in BED values observed between patients with rapid CLR decline (CLR loss per year >20%) compared with those with a slower decline.

DISCUSSION

The study indicates that kidney absorbed doses estimated by conventional dosimetry do not correlate with the renal toxicity observed in patients treated with 90Y-DOTATOC. In contrast, a clear dose–effect relationship was found when additional parameters, such as patient-specific kidney volume and rates at which the absorbed doses were delivered, were considered.

Our data provide evidence that 3 major variables influence the actual 90Y-DOTATOC renal absorbed dose estimates: distribution of the radionuclide, size of the target organ (i.e., the kidney), and the absorbed dose rate.

Spatial and temporal radionuclide distribution is generally assessed by quantitative imaging obtained at different time points after injection. Unfortunately, the therapeutic agent DOTATOC labeled with 90Y, a pure β−-particle emitter, is not suitable for quantitative imaging. The substitution of 90Y with a positron-emitter isotope of yttrium (86Y) provides an appropriate surrogate to predict the in vivo behavior of the therapeutic compound. Kidney uptake and retention of 90Y-DOTATOC as measured by PET biodistribution study with 86Y-DOTATOC varied between patients by a factor of 3 and resulted in a wide range of absorbed doses estimated using the MIRDOSE program (1.18–3.60 mGy/MBq). This is in good agreement with our previous report on a larger number of patients, in which we observed a variation in renal absorbed dose ranging between 1.2 and 5.1 mGy/MBq (10). Such variability of renal radionuclide distribution excludes the possibility of using average individuals and thus underlines the necessity of obtaining individual distribution measurement. Bodei et al. (30), using 111In-DOTATOC for quantitative imaging and the standard MIRD formalism for dosimetric calculations, also reported wide interindividual differences in renal dose estimates. The use of an 111In-labeled instead of an 86Y-labeled surrogate for dose estimation constitutes a promising approach that remains to be validated.

For the estimation of the absorbed dose in the MIRDOSE3.1 software, a standardized phantom value is used for kidney volume (i.e., 288 mL in males and 264 mL in women) (20). The retrospective assessment of individual kidney volumes on pretherapeutic CT showed wide interindividual variability, by as much as a factor of 2. This indicates that individual kidney volume determination is necessary to improve the accuracy of kidney absorbed dose estimation. Recent autoradiography studies performed on human kidney obtained after in vivo injection of 111In-labeled somatostatin analog showed radioactivity to be concentrated in the cortex, mainly in the juxtamedullary region (31). Unfortunately, such precise pattern of activity distribution inside the kidney cannot be determined for each patient by quantitative imaging because of the lack of spatial resolution of PET and SPECT cameras. Therefore, in this study, we considered that the radionuclide accumulated only in the cortical region, which, according to MIRD Pamphlet 19, represents 70% of total kidney volume (24). Although the inclusion of individual renal cortex volumes in the dosimetry calculations improved dose estimates, no clear dose–effect relationship was observed.

The third variable that was found to be important when implementing absorbed dose estimation was dose fractionation. The rationale of conventional fractionation in external beam radiotherapy is that dividing a dose into several fractions spares normal tissues because of the repair of sublethal damage between dose fractions. The latent period before the onset of radiation-induced functional damage depends on the rate of cell turnover of the tissue. Kidney parenchyma is a slow turnover tissue, and there is a considerable latency before any functional damage is apparent. In external radiotherapy, a dose of 23–27 Gy is considered to result in a 5%–50% probability of developing radiation nephropathy within 5 y after treatment (18). Such a dose is typically administered homogeneously and at a high dose rate in fractions of 1.5–2 Gy. In contrast, the radiation dose delivered during radionuclide therapy with 90Y-DOTATOC is given at a much lower rate and is exponentially decaying with an effective half-life of approximately 30 h (19). The penetration range of the radiation is shorter, and, as already mentioned, the distribution of the radionuclide within the organs is heterogeneous.

According to the LQ model, it was reported that the critical kidney dose for PRRT was higher than that for external radiotherapy and our results are in agreement (19). The median BED estimated in our patients was 37 Gy. The integration of the dose rate effect in the dosimetry estimation strongly improved the correlation between the resulting BED and renal function impairment. It should be noted that the 5 patients with BED values >45 Gy were those who exhibited the most rapid decline in CLR after treatment. Therefore, a BED value of 45 Gy could be proposed as a threshold limit for an increased risk of rapid decline of renal function.

Although our data suggest that the most prominent cause of renal toxicity with PRRT is the absorbed dose to the kidneys, other factors, such as preexisting hypertension, diabetes, or previous chemotherapy, may accelerate renal function loss induced by radiation, possibly by an unsuspected loss of “renal reserve.” It must be kept in mind that in adults the number of nephrons is fixed and would ineluctably decrease with time. This means that any damage to functional nephrons is irreparable but may remain clinically and biologically silent, because no simple tests are able to measure the maximum glomerular filtration rate. In this study, only 3 patients had undergone chemotherapy before 90Y-DOTATOC treatment. Two of them showed only a minor reduction in renal function after treatment. In the third patient, we observed a rapid decline in renal function, but the key role of chemotherapy could not be proven because the patient also had other potential risk factors, such as diabetes and preexisting hypertension. In addition, the latter patient received kidney doses estimated to be twice as high as those received by the 2 other patients. It should be noted that preexisting hypertension was found in 3 out of the 5 patients with CLR loss per year >20%, suggesting that preexisting hypertension could contribute to the impairment of renal function after therapy. However, a larger number of observations are needed to allow for definite conclusions.

The time appearance and dose-dependence of radiation damage in normal tissue depend on its proliferative behavior. For acutely responding tissues that express damage within a period of days to weeks after irradiation, the α/β-ratio is in the range of 7–20 Gy, whereas for late-responding tissues that express damage months to years after irradiation, that ratio ranges from 0.5 to 6 Gy (32). For the kidney we used the α/β-ratio (2.6 Gy) and half-time of DNA repair (2.8 h) generally accepted in the literature. These values were taken from data in a rodent model (29). Analyses of data from human tissues on DNA repair kinetics are in fact limited. However, the agreement between human and animal data is generally considered acceptable (33). The α/β-value provides a quantitative index of the sensitivity of a given organ or tumor to changes in dose rate. Tissues with low α/β-values, such as kidneys, are more sensitive to small changes in the dose rate or dose per fraction than tissues with high α/β-ratios, such as tumors. According to our results, it should be recommended to fractionate the total administered activities in more cycles to allow the sublethal radiation damage repair in normal tissue. However, the effect of dose fractionation on tumor response remains to be evaluated. It is generally admitted that the effect on tumors occurs earlier than in the kidney and that the α/β-value is generally higher for tumors (5–25 Gy) than for late-responding kidney (2–3 Gy). The increase in α/β-value for tumors compared with normal tissues has been observed in other cancers (33). Also, the DNA repair half-time is generally shorter in tumor cells (34). With a higher α/β-ratio and a lower DNA repair half-time, the ratio of the quadratic term versus the linear term in Equation 3 decreases, and, as a result, tumors are likely to be less sensitive to fractionation.

CONCLUSION

The use of a refined absorbed dose methodology led to the finding of a clear kidney dose–response relationship in patients treated with 90Y-DOTATOC. Our data provide evidence that patient-specific anatomy and dose-rate effects cannot be neglected. The BED model appears to be a reliable predictor of toxicity and could thus be helpful in implementation of individual treatment planning. Considering the complexity of 86Y quantitative imaging, further studies should evaluate whether dosimetric methods using a widely available tracer such as 111In-pentetreotide remain accurate enough to predict response.

Acknowledgments

The authors thank Joëlle De Camps for invaluable assistance in data collection.

Footnotes

  • Received Sep. 8, 2004; revision accepted Nov. 2, 2004.

    For correspondence or reprints contact: Stanislas Pauwels, MD, PhD, Centre de Médecine Nucléaire, Université Catholique de Louvain, UCL 54.30, Avenue Hippocrate, 54, B-1200 Brussels, Belgium.

    E-mail: stanislas.pauwels{at}mnuc.ucl.ac.be

REFERENCES

  1. ↵
    Reubi JC. Peptide receptors as molecular targets for cancer diagnosis and therapy. Endocr Rev. 2003;24:389–427.
    OpenUrlCrossRefPubMed
  2. ↵
    Otte A, Mueller-Brand J, Dellas S, Nitzsche EU, Herrmann R, Maecke HR. Yttrium-90-labelled somatostatin analogue for cancer treatment. Lancet. 1998;351:417–418.
    OpenUrlCrossRefPubMed
  3. ↵
    de Jong M, Valkema R, Jamar F, et al. Somatostatin receptor-targeted radionuclide therapy of tumors: pre-clinical and clinical findings. Semin Nucl Med. 2002;32:133–140.
    OpenUrlCrossRefPubMed
  4. Chinol M, Bodei L, Cremonesi M, Paganelli G. Receptor-mediated radiotherapy with 90Y-DOTA-D-Phe1-Tyr3-octreotide: the experience of the European Institute of Oncology Group. Semin Nucl Med. 2002;32:141–147.
    OpenUrlCrossRefPubMed
  5. Waldherr C, Pless M, Maecke HR, et al. Tumor response and clinical benefit in neuroendocrine tumors after 7.4 GBq 90Y-DOTATOC. J Nucl Med. 2002;43:610–616.
    OpenUrlAbstract/FREE Full Text
  6. Bushnell D, O’Dorisio T, Menda Y, et al. Evaluating the clinical effectiveness of 90Y-SMT 487 in patients with neuroendocrine tumors. J Nucl Med. 2003;44:1556–1560.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    Kwekkeboom DJ, Mueller-Brand J, Paganelli G, et al. An overview of the results of peptide receptor radionuclide therapy with 3 different radiolabeled somatostatin analogues. J Nucl Med. 2005;46(suppl):62S–66S.
    OpenUrlAbstract/FREE Full Text
  8. ↵
    Pauwels S, Barone R, Walrand S, et al. Practical dosimetry of peptide receptor radionuclide therapy with 90Y-labeled somatostatin analogues. J Nucl Med. 2005;46(suppl):92S–98S.
    OpenUrlAbstract/FREE Full Text
  9. ↵
    Jonard P, Jamar F, Walrand S, et al. Tumor dosimetry based on PET 86Y-DOTA-Tyr3-octreotide (SMT487) and CT-scan predicts tumor response to 90Y-SMT487 (Octreother™) therapy [abstract]. J Nucl Med. 2000;41(suppl):111P.
    OpenUrlAbstract/FREE Full Text
  10. ↵
    Jamar F, Barone R, Mathieu I, et al. 86Y-DOTA0-D-Phe1-Tyr3-octreotide (SMT487): a phase 1 clinical study—pharmacokinetics, biodistribution and renal protective effect of different regimens of amino acid co-infusion. Eur J Nucl Med Mol Imaging. 2003;30:510–518.
    OpenUrlCrossRefPubMed
  11. Förster GJ, Engelbach MJ, Brockmann J, et al. Preliminary data on biodistribution and dosimetry for therapy planning of somatostatin receptor positive tumours: comparison of 86Y-DOTATOC and 111In-DTPA-octreotide. Eur J Nucl Med. 2001;28:1743–1750.
    OpenUrlCrossRefPubMed
  12. Cremonesi M, Ferrari M, Zoboli S, et al. Biokinetics and dosimetry in patients administered with 111In-DOTA-Tyr3-octreotide: implication for internal radiotherapy with 90Y-DOTATOC. Eur J Nucl Med. 1999;26:877–886.
    OpenUrlCrossRefPubMed
  13. ↵
    Otte A, Hermann R, Heppeler A, et al. Yttrium-90 DOTATOC: first clinical results. Eur J Nucl Med. 1999;26:1439–1447.
    OpenUrlCrossRefPubMed
  14. Moll S, Nickeleit V, Mueller-Brand J, Brunner FP, Maecke HR, Mihatsch MJ. A new cause of renal thrombotic microangiopathy: yttrium 90-DOTATOC internal radiotherapy. Am J Kidney Dis. 2001;37:847–851.
    OpenUrlPubMed
  15. Cybulla M, Weiner SM, Otte A. End stage renal disease after treatment with 90Y-DOTATOC. Eur J Nucl Med. 2001;28:1552–1554.
    OpenUrlCrossRefPubMed
  16. Boerman OC, Oyen WJG, Corstens FHM. Between the Scylla and Charybdis of peptide radionuclide therapy: hitting the tumor and saving the kidney. Eur J Nucl Med. 2001;28:1447–1449.
    OpenUrlCrossRefPubMed
  17. ↵
    Stoffel MP, Pollok M, Fries J, Baldamus CA. Radiation nephropathy after radiotherapy in metastatic medullary thyroid carcinoma. Nephrol Dial Transplant. 2001;16:1082–1083.
    OpenUrlFREE Full Text
  18. ↵
    Emami B, Lyman J, Brown A, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 1991;21:109–122.
    OpenUrlPubMed
  19. ↵
    Konijnenberg MW. Is the renal dosimetry for [90Y-DOTA0,Tyr3]octreotide accurate enough to predict thresholds for individual patients? Cancer Biother Radiopharm. 2003;18:619–625.
    OpenUrlCrossRefPubMed
  20. ↵
    Stabin MG. MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 1996;37:538–546.
    OpenUrlFREE Full Text
  21. ↵
    Valkema R, Kvols L, Jamar F, et al. Phase 1 study of therapy with 90Y-SMT487 (OctreoTher®) in patients with somatostatin receptor (SS-R) positive tumors [abstract]. J Nucl Med. 2002;43(suppl):P120.
    OpenUrl
  22. ↵
    Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron. 1976;16:31–41.
    OpenUrlCrossRefPubMed
  23. ↵
    Valkema R, Pauwels S, Kvols LK, et al. Long-term follow-up of renal function after peptide receptor radiation therapy (PRRT) with [90Y-DOTA0,Tyr3]octreotide and [177Lu-DOTA0,Tyr3]octreotate. J Nucl Med. 2005;46(suppl):83S–91S.
    OpenUrlAbstract/FREE Full Text
  24. ↵
    Bouchet LG, Bolch WE, Blanco HP, et al. MIRD pamphlet no. 19: absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney. J Nucl Med. 2003;44:1113–1147.
    OpenUrlAbstract/FREE Full Text
  25. ↵
    Rösch F, Qaim SM, Stöcklin G. Production of the positron emitting radioisotope 86Y for nuclear medical applications. Int J Appl Radiat Isot. 1993;44:677–681.
    OpenUrl
  26. ↵
    Wienhard K, Dahlböm M, Eriksson L, et al. The ECAT EXACT HR: performance of a new high resolution positron scanner. J Comput Assist Tomogr. 1994;18:110–118.
    OpenUrlPubMed
  27. ↵
    Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601–609.
    OpenUrlCrossRefPubMed
  28. ↵
    Walrand SH, Jamar F, Mathieu I, et al. Quantification in PET using isotopes emitting prompt single gammas: application to 86Y. Eur J Nucl Med. 2003;30:354–361.
    OpenUrl
  29. ↵
    Thames HD, Ang KK, Stewart FA, van Der Schuren E. Does incomplete repair explain the apparent failure of the basic LQ model to predict spinal cord and kidney responses to low doses per fraction? Int J Radiat Biol. 1988;54:13–19.
    OpenUrlPubMed
  30. ↵
    Bodei L, Cremonesi M, Zoboli S, et al. Receptor-mediated radionuclide therapy with 90Y-DOTATOC in association with amino acid infusion: a phase I study. Eur J Nucl Med. 2003;30:207–216.
    OpenUrl
  31. ↵
    de Jong M, Valkema R, van Gameren A, et al. Inhomogeneous localization of radioactivity in the human kidney after injection of [111In-DTPA]octreotide. J Nucl Med. 2004;45:1168–1171.
    OpenUrlAbstract/FREE Full Text
  32. ↵
    Dale R. Use of the linear-quadratic radiobiological model for quantifying kidney response in targeted radiotherapy. Cancer Biother Radiopharm. 2004;19:363–369.
    OpenUrlCrossRefPubMed
  33. ↵
    Thames HD, Bentzen SM, Turesson I, Overgaard M, Van den Bogaert W. Time-dose factors in radiotherapy: a review of human data. Radiother Oncol. 1990;19:219–235.
    OpenUrlCrossRefPubMed
  34. ↵
    Joiner MC, van der Kogel AJ. The linear-quadratic approach to fractionation and calculation of isoeffect relationships. In: Steel GG, ed. Basic Clinical Radiobiology. London, UK: Arnold; 1997:106–122.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 46 (1 suppl)
Journal of Nuclear Medicine
Vol. 46, Issue 1 suppl
January 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Patient-Specific Dosimetry in Predicting Renal Toxicity with 90Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose–Effect Relationship
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Patient-Specific Dosimetry in Predicting Renal Toxicity with 90Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose–Effect Relationship
Raffaella Barone, Françoise Borson-Chazot, Roelf Valkema, Stéphan Walrand, Franck Chauvin, Lida Gogou, Larry K. Kvols, Eric P. Krenning, François Jamar, Stanislas Pauwels
Journal of Nuclear Medicine Jan 2005, 46 (1 suppl) 99S-106S;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Patient-Specific Dosimetry in Predicting Renal Toxicity with 90Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose–Effect Relationship
Raffaella Barone, Françoise Borson-Chazot, Roelf Valkema, Stéphan Walrand, Franck Chauvin, Lida Gogou, Larry K. Kvols, Eric P. Krenning, François Jamar, Stanislas Pauwels
Journal of Nuclear Medicine Jan 2005, 46 (1 suppl) 99S-106S;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Quality Assurance Considerations in Radiopharmaceutical Therapy Dosimetry Using PLANETDose: An International Atomic Energy Agency Study
  • Lesion Dosimetry for [177Lu]Lu-PSMA-617 Radiopharmaceutical Therapy Combined with Stereotactic Body Radiotherapy in Patients with Oligometastatic Castration-Sensitive Prostate Cancer
  • Pre-clinical Evaluation of Biomarkers for Early Detection of Nephrotoxicity Following Alpha-particle Radioligand Therapy
  • A Realistic Multiregion Mouse Kidney Dosimetry Model to Support the Preclinical Evaluation of Potential Nephrotoxicity of Radiopharmaceutical Therapy
  • Dosimetric Quantities in Neuroendocrine Tumors over Treatment Cycles with 177Lu-DOTATATE
  • Dosimetry for Radiopharmaceutical Therapy: The European Perspective
  • Dosimetry for Radiopharmaceutical Therapy: Current Practices and Commercial Resources
  • Addition of 131I-MIBG to PRRT (90Y-DOTATOC) for Personalized Treatment of Selected Patients with Neuroendocrine Tumors
  • Inflammation-Based Index and 68Ga-DOTATOC PET-Derived Uptake and Volumetric Parameters Predict Outcome in Neuroendocrine Tumor Patients Treated with 90Y-DOTATOC
  • Prediction of Tumor Control in 90Y Radioembolization by Logit Models with PET/CT-Based Dose Metrics
  • 90Y-DOTATOC Dosimetry-Based Personalized Peptide Receptor Radionuclide Therapy
  • International Union of Basic and Clinical Pharmacology. CV. Somatostatin Receptors: Structure, Function, Ligands, and New Nomenclature
  • Clinical History of the Theranostic Radionuclide Approach to Neuroendocrine Tumors and Other Types of Cancer: Historical Review Based on an Interview of Eric P. Krenning by Rachel Levine
  • Individualized Dosimetry for Theranostics: Necessary, Nice to Have, or Counterproductive?
  • Dose Response of Pancreatic Neuroendocrine Tumors Treated with Peptide Receptor Radionuclide Therapy Using 177Lu-DOTATATE
  • A Hepatic Dose-Toxicity Model Opening the Way Toward Individualized Radioembolization Planning
  • Targeted Radionuclide Therapy: Proceedings of a Joint Workshop Hosted by the National Cancer Institute and the Society of Nuclear Medicine and Molecular Imaging
  • Radiobiologic Optimization of Combination Radiopharmaceutical Therapy Applied to Myeloablative Treatment of Non-Hodgkin Lymphoma
  • Individualized Dosimetry of Kidney and Bone Marrow in Patients Undergoing 177Lu-DOTA-Octreotate Treatment
  • Altered Biodistribution of Somatostatin Analogues After First Cycle of Peptide Receptor Radionuclide Therapy
  • RADAR Commentary: Evolution and Current Status of Dosimetry in Nuclear Medicine
  • 4-Step Renal Dosimetry Dependent on Cortex Geometry Applied to 90Y Peptide Receptor Radiotherapy: Evaluation Using a Fillable Kidney Phantom Imaged by 90Y PET
  • Renal Toxicity of Radiolabeled Peptides and Antibody Fragments: Mechanisms, Impact on Radionuclide Therapy, and Strategies for Prevention
  • Arterial Wall Dosimetry for Non-Hodgkin Lymphoma Patients Treated with Radioimmunotherapy
  • Efficacy of Systemic Radionuclide Therapy with p-131I-Iodo-L-Phenylalanine Combined with External Beam Photon Irradiation in Treating Malignant Gliomas
  • Pretargeted Radioimmunotherapy of Pancreatic Cancer Xenografts: TF10-90Y-IMP-288 Alone and Combined with Gemcitabine
  • High-Dose Yttrium-90-Ibritumomab Tiuxetan With Tandem Stem-Cell Reinfusion: An Outpatient Preparative Regimen for Autologous Hematopoietic Cell Transplantation
  • MIRD Pamphlet No. 20: The Effect of Model Assumptions on Kidney Dosimetry and Response--Implications for Radionuclide Therapy
  • High-Dose Radioimmunotherapy with 90Y-Ibritumomab Tiuxetan: Comparative Dosimetric Study for Tailored Treatment
  • Radiation Dose Distribution in Human Kidneys by Octreotides in Peptide Receptor Radionuclide Therapy
  • Spatial Dose Mapping for Individualizing Radioiodine Treatment
  • Dosimetry in Peptide Radionuclide Receptor Therapy: A Review
  • Treatment of advanced neuroendocrine tumours with radiolabelled somatostatin analogues
  • Google Scholar

More in this TOC Section

  • Tositumomab and 131I Therapy in Non-Hodgkin’s Lymphoma
  • The Promise of Targeted α-Particle Therapy
  • Practical Dosimetry of Peptide Receptor Radionuclide Therapy with 90Y-Labeled Somatostatin Analogs
Show more Clinical Practice of Molecular Radiotherapy

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire