Basic Science Investigation |
1 Departments of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario, Canada; 2 Department of Radiation Oncology and Biology, University of Oxford, Oxford, United Kingdom; 3 Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada; and 4 Toronto General Research Institute, University Health Network, Toronto, Ontario, Canada
Correspondence: For correspondence or reprints contact: Raymond M. Reilly, PhD, Leslie Dan Faculty of Pharmacy, University of Toronto, 144 College St., Toronto, Ontario, Canada M5S 3M2. E-mail: raymond.reilly{at}utoronto.ca
The cytotoxicity and tumor-targeting properties of the anti-HER2/neu monoclonal antibody trastuzumab modified with peptides (CGYGPKKKRKVGG) harboring the nuclear localization sequence ([NLS] italicized) of simian virus 40 large T-antigen and radiolabeled with 111In were evaluated. Methods: Trastuzumab was derivatized with sulfosuccinimidyl-4-(N-maleimidomethyl)cyclohexane-1-carboxylate (sulfo-SMCC) for reaction with NLS-peptides and labeled with 111In using diethylenetriaminepentaacetic acid (DTPA). The immunoreactivity of 111In-NLS-trastuzumab was determined by its ability to displace the binding of trastuzumab to SK-BR-3 human breast cancer (BC) cells. Cellular uptake and nuclear localization were evaluated in SK-BR-3, MDA-MB-361, and MDA-MB-231 BC cells, expressing high, intermediate, or very low levels of HER2/neu, respectively, by cell fractionation and confocal microscopy. Biodistribution and nuclear uptake were compared in athymic mice bearing MDA-MB-361 xenografts. The cytotoxicity of 111In-trastuzumab and 111In-NLS-trastuzumab was studied by clonogenic assays, and DNA damage was assessed by probing for phosphorylated histone H2AX (
H2AX) foci. Results: The dissociation constant for binding of 111In-NLS-trastuzumab to SK-BR-3 cells was reduced <3-fold compared with that of 111In-trastuzumab, demonstrating relatively preserved receptor-binding affinity. The receptor-mediated internalization of 111In-trastuzumab in SK-BR-3, MDA-MB-361, and MDA-MB-231 cells increased significantly from 7.2% ± 0.9%, 1.3% ± 0.1%, and 0.2% ± 0.05% to 14.4% ± 1.8%, 6.3% ± 0.2%, and 0.9% ± 0.2% for 111In-NLS-trastuzumab harboring 6 NLS-peptides, respectively. NLS-trastuzumab localized in the nuclei of BC cells, whereas unmodified trastuzumab remained surface-bound. Conjugation of 111In-trastuzumab to NLS-peptides did not affect its tissue biodistribution but promoted specific nuclear uptake in MDA-MB-361 xenografts (2.4–2.9 %ID/g [percentage injected dose per gram] for 111In-NLS-trastuzumab and 1.1 %ID/g for 111In-trastuzumab). 111In-NLS-trastuzumab was 5- and 2-fold more potent at killing SK-BR-3 and MDA-MB-361 cells than 111In-trastuzumab, respectively, whereas toxicity toward MDA-MB-231 cells was minimal. 111In-NLS-trastuzumab was 6-fold more effective at killing SK-BR-3 cells than unlabeled trastuzumab. Formation of
H2AX foci occurred in a greater proportion of BC cells after incubation with 111In-NLS-trastuzumab compared with 111In-trastuzumab or unlabeled trastuzumab. Conclusion: NLS-peptides routed 111In-trastuzumab to the nucleus of HER2/neu-positive human BC cells, rendering the radiopharmaceutical lethal to the cells through the emission of nanometer–micrometer range Auger electrons. The greater cytotoxic potency of 111In-NLS-trastuzumab compared with unlabeled trastuzumab in vitro and its favorable tumor-targeting properties in vivo suggest that it could be an effective targeted radiotherapeutic agent for HER2/neu-amplified BC in humans.
Key Words: breast cancer trastuzumab (Herceptin) 111In nuclear translocation Auger electrons
COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.
Related articles in JNM:
This article has been cited by other articles:
![]() |
X. Liu, Y. Wang, K. Nakamura, S. Kawauchi, A. Akalin, D. Cheng, L. Chen, M. Rusckowski, and D. J. Hnatowich Auger Radiation-Induced, Antisense-Mediated Cytotoxicity of Tumor Cells Using a 3-Component Streptavidin-Delivery Nanoparticle with 111In J. Nucl. Med., April 1, 2009; 50(4): 582 - 590. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. L. Costantini, K. Bateman, K. McLarty, K. A. Vallis, and R. M. Reilly Trastuzumab-Resistant Breast Cancer Cells Remain Sensitive to the Auger Electron-Emitting Radiotherapeutic Agent 111In-NLS-Trastuzumab and Are Radiosensitized by Methotrexate J. Nucl. Med., September 1, 2008; 49(9): 1498 - 1505. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Lindegren, S. Frost, T. Back, E. Haglund, J. Elgqvist, and H. Jensen Direct Procedure for the Production of 211At-Labeled Antibodies with an {varepsilon}-Lysyl-3-(Trimethylstannyl)Benzamide Immunoconjugate J. Nucl. Med., September 1, 2008; 49(9): 1537 - 1545. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Cai, Z. Chen, K. E. Bailey, D. A. Scollard, R. M. Reilly, and K. A. Vallis Relationship Between Induction of Phosphorylated H2AX and Survival in Breast Cancer Cells Exposed to 111In-DTPA-hEGF J. Nucl. Med., August 1, 2008; 49(8): 1353 - 1361. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Mankoff, J. M. Link, H. M. Linden, L. Sundararajan, and K. A. Krohn Tumor Receptor Imaging J. Nucl. Med., June 1, 2008; 49(Suppl_2): 149S - 163S. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |