Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Brief ReportBRIEF COMMUNICATION

Uptake of Cis-4-[18F]Fluoro-l-Proline in Urologic Tumors

Karl-Josef Langen, Anne Rose Börner, Volker Müller-Mattheis, Kurt Hamacher, Hans Herzog, Rolf Ackermann and Heinz H. Coenen
Journal of Nuclear Medicine May 2001, 42 (5) 752-754;
Karl-Josef Langen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anne Rose Börner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Volker Müller-Mattheis
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kurt Hamacher
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hans Herzog
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rolf Ackermann
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heinz H. Coenen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Tumor uptake of the amino acid cis-4-[18F]fluoro-l-proline (cis-FPro) was studied with PET in eight patients with urologic tumors. Methods: Three patients had primary renal cell carcinomas (RCCs), one had a local recurrence of RCC, one had squamous RCC, one had an adrenal hemangioma, one had inguinal metastases of penile squamous carcinoma, and one had suspected metastatic disease from prostate cancer. PET scans of the trunk were acquired at 1 and 3–5 h after intravenous injection of 400 MBq cis-FPro and compared with 18F-FDG PET scans and CT. Results: None of the tumors or metastases showed significant uptake of cis-FPro. FDG uptake was seen in one of the three primary RCCs, in the local recurrence of RCC, in the squamous RCC, and in the metastases of penile cancer. Conclusion: Cis-FPro appears not to be a promising PET tracer in oncology.

  • cis-4-[18F]fluoro-l-proline
  • radiolabeled amino acids
  • renal tumors
  • PET

The diagnostic value of 18F-FDG PET for the evaluation of renal malignancies is limited (1). Radiolabeled amino acids may help to overcome some of the diagnostic limitations of FDG. Most of the interesting amino acids proposed for PET, however, can be labeled with only the short-lived positron emitter 11C (20-min half-life), whose use is restricted to a few PET centers with a cyclotron and a radiochemistry laboratory on site. Recently, the diastereoisomers cis-4-[18F]fluoro-l-proline (cis-FPro) and trans-4-[18F]fluoro-l-proline (trans-FPro) labeled with the longer lived 18F (110-min half-life) have been presented. These can be synthesized with high radiochemical yields, allowing large-scale production for clinical purposes (2). Animal experiments have shown that more cis-FPro than trans-FPro accumulates in osteosarcomas, and tissue homogenates revealed protein incorporation of only cis-FPro (3). In this pilot study, we investigated the potential of cis-FPro for tumor imaging in humans.

MATERIALS AND METHODS

Patients

Eight patients (two women, six men; age range, 37–81 y) were included in this pilot study. Table 1 gives further information on the patients. Histopathologic data were obtained by surgical resection of the primary tumors after the PET studies or were already known from previous resection of the primary tumors in patients with recurrences or metastatic disease. Patient 3 had advanced metastatic disease and did not undergo surgery, so no information on the histopathology of the tumor is available. Three patients had primary renal cell carcinomas (RCCs) (one with distant metastases), one patient had recurrent RCC, one patient had squamous RCC with regional lymph node metastases, one patient had a hemangioma of the left adrenal gland, one patient had inguinal lymph node metastases of penile squamous carcinoma, and one patient had suspected metastatic disease from prostate cancer. The study was approved by the local ethical committee and federal authorities. All patients gave written informed consent to participate in the study. Laboratory values of kidney and liver function were normal in all patients.

View this table:
  • View inline
  • View popup
TABLE 1

Data on Patients and on Cis-FPro and FDG Uptake in Urologic Tumors

Radiopharmaceuticals

Cis-FPro was prepared with a radiochemical yield of 36% ± 7%, a radiochemical purity > 98%, and a specific radioactivity of >18.5 GBq/μmol as previously described (2). The tracer was administered to the patients intravenously as a phosphate buffer solution with a pH of 6.5–8.

FDG was synthesized according to a drug master file created at the Institute of Nuclear Chemistry in Jülich, Germany. The average specific activity was >370 GBq/μmol.

PET

All patients fasted for at least 12 h before the PET studies. After intravenous injection of 400 MBq cis-FPro early (1 h after injection) and late (between 3 and 5 h after injection), PET scans of the trunk (three to five bed positions) were obtained for each patient.

All patients except patient 3 underwent comparative investigations after intravenous injection of 400 MBq FDG within 1 wk before or after cis-FPro PET using the same scanning protocol. The studies were done using either an ECAT EXACT HR+ scanner (Siemens Medical Systems, Inc., Hoffman Estates, IL/CTI, Knoxville, TN) (full width at half maximum, 4.5 mm; 15-cm transaxial field of view) or a PC4096+ scanner (General Electric Medical Systems, Milwaukee, WI) (full width at half maximum, 5.4 mm; 10-cm transaxial field of view). Transmission scanning was performed with 68Ge/68Ga rotating line sources and used for measured attenuation correction. After correction for random and scattered coincidences, dead time, and decay, data were reconstructed with an iterative algorithm. Using transaxial slices and whole-body reprojected images, two independent observers visually evaluated the data and compared them with the corresponding transaxial CT scans. Tumor uptake was rated as − (uptake at or below background level), + (discrete tracer uptake above background level), or ++ (intensive tracer uptake, or hot spot).

RESULTS

Table 1 gives the data on cis-FPro and FDG uptake. None of the tumors or metastatic lesions in this series of patients showed relevant uptake of cis-FPro. Cis-FPro distribution did not significantly differ between the early and the late scans. Of the three patients with primary RCC, only one showed discrete uptake (+) of FDG. The reprojected PET scans of cis-FPro and FDG uptake, as well as the CT scan of an RCC that was negative for uptake of either tracer, are shown in Figure 1 (patient 2). The squamous carcinoma of the kidney showed intensive FDG uptake in the primary tumor (++) and in the regional lymph node metastases (Fig. 2), whereas cis-FPro was negative for FDG uptake. The hemangioma was negative for uptake of either tracer. The inguinal lymph node metastases of a penile squamous carcinoma could be detected by FDG scanning (++) but were negative for cis-FPro uptake.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

PET and CT scans of 72-y-old man (patient 2) with left-sided renal clear cell carcinoma. (A) Reprojected whole-body scan using cis-FPro shows negative findings (dotted oval). Note uptake in renal cortex and pancreas. (B) Reprojected whole-body scan using FDG shows negative findings (dotted oval). (C) Transaxial CT scan at tumor level shows large, hypodense mass in left kidney.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

PET and CT scans of 81-y-old woman (patient 5) with left-sided renal squamous carcinoma. (A) Reprojected whole-body scan using cis-FPro shows relevant uptake neither in primary tumor nor in metastases (dotted oval). (B) Reprojected whole-body scan using FDG shows intensive uptake in primary tumor and regional lymph node metastases (dotted oval). (C) Transaxial CT scan at tumor level shows hypodense renal mass and enlarged para-aortic lymph nodes.

The PET scan of the patient with suspected metastatic disease from prostate cancer was negative for uptake of either tracer. The suspicion of metastatic disease in this patient was based on an elevated prostate-specific antigen level of 39.7 ng/mL. The CT scan and the whole-body bone scan were negative for uptake at the time of the PET studies, but bone metastases developed 12 mo later.

DISCUSSION

Several pathologic processes, such as tumor growth, lung fibrosis, and hepatocirrhosis, are related to increased regional collagen synthesis. Because proline and hydroxyproline represent major constituents of mammalian structural proteins, especially of collagen, the 18F-labeled proline analogs cis-FPro and trans-FPro have been proposed as potential tracers for PET imaging of tumors and abnormal collagen synthesis rates (2). Experiments on the biodistribution of cis-FPro and trans-FPro in tumor-bearing mice have shown that more cis-FPro than trans-FPro accumulates in osteosarcomas, and tissue homogenates revealed protein incorporation of only cis-FPro (3).

In this pilot study, we examined cis-FPro for the imaging of renal tumors and one case of penile cancer with metastatic disease. However, this tracer significantly accumulated neither in renal clear cell carcinomas nor in squamous carcinomas. Also, no uptake was apparent in prostate cancer metastases. These data indicate that the tumor affinity of cis-FPro is limited, and the promise of cis-FPro as a tracer for human tumors appears questionable. Nevertheless, other histologic entities, such as osteosarcomas, breast carcinomas, and colon carcinomas, may be evaluated because experimental studies have shown tumor uptake of cis-FPro (3). Why cis-FPro fails to image the tumor entities investigated in this study remains unclear. Animal experiments have shown that cis-FPro incorporates some protein, although slowly. The processes involved in the transport mechanisms of this nonphysiologic amino acid need further study.

After a preliminary evaluation, we reported an increased uptake of cis-FPro in some RCCs (4). This increase, however, proved to be a misinterpretation because of cis-FPro uptake in the adjacent pancreas. A more sophisticated evaluation of the data in comparison with transaxial CT scans revealed that the tumor area itself showed no uptake of cis-FPro.

The diagnostic value of FDG imaging in renal tumors is also questionable because only a fraction of these tumors exhibit FDG uptake (1). The results of our study confirm the limited potential of FDG for the diagnosis of renal tumors.

CONCLUSION

In this series of urologic tumors, no relevant cis-FPro uptake could be detected. The promise of cis-FPro as a PET tracer in oncology appears questionable. Other malignancies, however, have to be studied before final conclusions can be drawn.

Acknowledgments

The authors thank Elisabeth Theelen and Susanne Schaden for assistance with patient studies, Lutz Tellmann for data management, and Bettina Palm and Erika Wabbals for technical assistance with the radiosynthesis of cis-FPro.

Footnotes

  • Received Aug. 30, 2000; revision accepted Jan. 10, 2001.

    For correspondence or reprints contact: Karl-Josef Langen, MD, Institute of Medicine, Research Center Jülich, P.O. Box 1913, D-52425 Jülich, Germany.

REFERENCES

  1. ↵
    Montravers F, Grahek D, Kerrou K, et al. Evaluation of FDG uptake by renal malignancies (primary tumor or metastases) using a coincidence detection gamma camera. J Nucl Med 2000;41:78–84.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Hamacher K. Synthesis of n.c.a. cis- and trans-4-[18F]fluoro-L-proline, radiotracer for PET-investigation of disordered matrix protein synthesis. J Labelled Compd Radiopharm. 1999;42:1135–1142.
    OpenUrlCrossRef
  3. ↵
    Wester HJ, Herz M, Senekowitsch-Schmidtke R, et al. Preclinical evaluation of 4-[18F]fluoroprolines: diastereomeric effect on metabolism and uptake in mice. Nucl Med Biol. 1999;3:259–265.
    OpenUrl
  4. ↵
    Boerner AR, Hamacher K, Herzog H, et al. Cis-4-[18F]-fluoroproline PET: preliminary results in urological tumors [abstract]. Eur J Nucl Med. 1999;26:1017.
    OpenUrl
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 42, Issue 5
May 1, 2001
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Uptake of Cis-4-[18F]Fluoro-l-Proline in Urologic Tumors
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Uptake of Cis-4-[18F]Fluoro-l-Proline in Urologic Tumors
Karl-Josef Langen, Anne Rose Börner, Volker Müller-Mattheis, Kurt Hamacher, Hans Herzog, Rolf Ackermann, Heinz H. Coenen
Journal of Nuclear Medicine May 2001, 42 (5) 752-754;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Uptake of Cis-4-[18F]Fluoro-l-Proline in Urologic Tumors
Karl-Josef Langen, Anne Rose Börner, Volker Müller-Mattheis, Kurt Hamacher, Hans Herzog, Rolf Ackermann, Heinz H. Coenen
Journal of Nuclear Medicine May 2001, 42 (5) 752-754;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Boramino acid as a marker for amino acid transporters
  • Detection of Secondary Thalamic Degeneration After Cortical Infarction Using cis-4-18F-Fluoro- D-Proline
  • 18F-FDG PET/CT for Staging of Penile Cancer
  • Google Scholar

More in this TOC Section

  • Measuring Total Metabolic Tumor Volume from 18F-FDG PET: A Reality Check
  • Bioanalytic Hybrid System Merging 3-Dimensional Cell Culture and Chromatographic Precision for Unprecedented Preclinical Insights in Molecular Imaging
  • Radiances of Cerenkov-Emitting Radionuclides on the In Vivo Imaging System
Show more BRIEF COMMUNICATION

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire