Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherClinical Investigations

Treatment with 177Lu-DOTATOC of Patients with Relapse of Neuroendocrine Tumors After Treatment with 90Y-DOTATOC

Flavio Forrer, Helena Uusijärvi, Daniel Storch, Helmut R. Maecke and Jan Mueller-Brand
Journal of Nuclear Medicine August 2005, 46 (8) 1310-1316;
Flavio Forrer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Helena Uusijärvi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel Storch
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Helmut R. Maecke
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jan Mueller-Brand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Therapy with [90Y-DOTA0, Tyr3]-octreotide (DOTATOC, where DOTA = tetraazacyclododecane tetraacetic acid and TOC = d-Phe-c(Cys-Tyr-d-Trp-Lys-Thr-Cys)-Thr(ol)) is established for the treatment of metastatic neuroendocrine tumors. Nevertheless, many patients experience disease relapse, and further treatment may cause renal failure. Trials with 177Lu-labeled somatostatin analogs showed less nephrotoxicity. We initiated a prospective study with 177Lu-DOTATOC in patients with relapsed neuroendocrine tumors after 90Y-DOTATOC treatment. Methods: Twenty-seven patients, pretreated with 90Y-DOTATOC, were included. The mean time between the last treatment with 90Y-DOTATOC and 177Lu-DOTATOC was 15.4 ± 7.8 mo (SD). All patients were injected with 7,400 MBq of 177Lu-DOTATOC. Restaging was performed after 8–12 wk. Hematotoxicity or renal toxicity of World Health Organization grade 1 or 2 was not an exclusion criterion. Results: Creatinine levels increased significantly, from 66 ± 14 μmol/L to 100 ± 44 μmol/L (P < 0.0001), after 90Y-DOTATOC therapy. The mean hemoglobin level dropped from 131 ± 14 to 117 ± 13 g/L (P < 0.0001) after 90Y-DOTATOC therapy. 177Lu-DOTATOC therapy was well tolerated. No serious adverse events occurred. The mean absorbed doses were 413 ± 159 mGy for the whole body, 3.1 ± 1.5 Gy for the kidneys, and 61 ± 5 mGy for the red marrow. After restaging, we found a partial remission in 2 patients, a minor response in 5 patients, stable disease in 12 patients, and progressive disease in 8 patients. Mean hemoglobin and creatinine levels did not change significantly. Conclusion: 177Lu-DOTATOC therapy in patients with relapse after 90Y-DOTATOC treatment is feasible, safe, and efficacious. No serious adverse events occurred.

  • 177Lu-DOTATOC
  • 90Y-DOTATOC
  • radionuclide therapy
  • somatostatin
  • neuroendocrine tumors

Treatment options for metastatic neuroendocrine tumors are limited. Trials with long-acting somatostatin analogs (octreotide or lanreotide), interferon-α, or chemotherapy, mostly 5-fluorouracil based, have shown rather low response rates with regard to cytoreduction (1–3). However, somatostatin analogs inhibit flushing, diarrhea, and other symptoms of the carcinoid syndrome (4,5). A retrospective case series in 1996 suggested that survival has increased since the introduction of somatostatin analogs (6). In the last few years, treatment strategies with radiolabeled somatostatin analogs have shown more convincing results (7–13). The 3 most investigated radiopharmaceuticals in clinical trials are [111In-diethylenetriaminepentaacetic acid (DTPA)0]-octreotide, [90Y-DOTA0, Tyr3]-octreotide (DOTATOC, where DOTA = tetraazacyclododecane tetraacetic acid and TOC = d-Phe-c(Cys-Tyr-d-Trp-Lys-Thr-Cys)-Thr(ol)), and [177Lu-DOTA0, Tyr3, Thr8]-octreotide (DOTATATE) (7–13).

Initial studies with high activities of [111In-DTPA0]-octreotide were encouraging. Although partial remissions were not found, favorable effects on symptoms were reported. Many patients in poor clinical condition were included (12,13). For the other 2 radiopeptides, a high overall response rate and distinct improvement in quality of life could be demonstrated (10,14). Although the results with these radiolabeled somatostatin analogs seem promising, relapses occur after a certain time in many patients (15), and further treatment with 90Y-DOTATOC can cause renal failure (16). According to data in the literature, the median time to progression after treatment with 90Y-DOTATOC is 30 mo (17,18). For 177Lu-DOTATATE, the median time to progression had not been reached at 25 mo after the start of therapy (19).

In comparison to 90Y, which is a high-energy, pure β-emitter (Emax, 2.25 MeV), 177Lu is a low-energy β-emitter (maximum electron energy [Emax], 0.497 MeV) with a small γ-component that is suitable for scintigraphic imaging (133 keV [6.5%]; 208 keV [11%]) without using a radionuclide surrogate. Small peptides such as DOTATOC are reabsorbed by the proximal tubules of the kidneys (20). The damage that can occur after treatment with 90Y-DOTATOC is in the glomeruli. It is conceivable that the length of the β-particles influences kidney toxicity. This hypothesis is supported by animal experiments (21).

Renal toxicity has been identified as the dose-limiting factor of 90Y-DOTATOC therapy (9). In a study with [177Lu-DOTA0, Tyr3, Thr8]-octreotide, no nephrotoxicity was found (11). Although no long-term outcome data concerning nephrotoxicity after treatment with 90Y-DOTATOC or 177Lu-DOTATATE are available, we assumed that 177Lu might be less nephrotoxic than 90Y.

In vitro, a higher affinity to the somatostatin receptor subtype 2 was demonstrated for Y(III)-DOTATATE than for Y(III)-DOTATOC (22). However, because in humans a better tumor-to-kidney-ratio was found for 111In-DOTATOC than for 111In-DOTATATE (23), we decided to use DOTATOC as a DOTA-peptide conjugate labeled to 177Lu in patients with relapse.

We initiated a prospective feasibility study with 177Lu-DOTATOC in patients with relapse of neuroendocrine tumors after successful treatment with 90Y-DOTATOC. Because of the assumption that 177Lu-DOTATOC is less nephrotoxic than 90Y-DOTATOC, we did not consider World Health Organization (WHO) grade 1 or 2 renal toxicity, based on creatinine levels, to be an exclusion criterion, nor were patients with WHO grade 1 or 2 hematotoxicity excluded. Human data for 177Lu-DOTATATE show promising results and a tolerable toxicity for injected activities of around 22.2–29.6 GBq (600–800 mCi) in patients who are not pretreated with peptide receptor–mediated radionuclide therapy (11). But for 177Lu-DOTATOC, we could find no human data in the literature. Because our patients were pretreated with peptide receptor–mediated radionuclide therapy, and because no dosimetric data were available, we started with a relatively low injected activity. We treated all patients with a fixed activity of 7,400 MBq (200 mCi).

MATERIALS AND METHODS

The study was approved by the local ethical committee and the Swiss authorities. All patients gave written informed consent.

Patients

Twenty-seven patients (17 men and 10 women) were included. The mean age (± SD) was 58 ± 9 y. All patients had a histologically confirmed metastatic neuroendocrine tumor, which was progressive at the time of treatment. The progression was demonstrated by CT or ultrasound in all patients. All patients were pretreated with 90Y-DOTATOC and benefited from this treatment. Benefit was defined as complete remission, partial remission, minor response, or stable disease according to the WHO standard criteria. For the partial remissions in our collective, the mean time to progression was 15.4 ± 6.9 mo. Many patients were pretreated with surgery, chemotherapy, octreotide, or interferon as well. Details are listed in Table 1.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

Pretherapeutically, all patients underwent staging with CT, 111In-pentetreotide scintigraphy (OctreoScan; Mallinckrodt, Inc.), complete blood counts, and blood chemistry. The findings of 111In-octreotide scintigraphy were strongly positive in all patients. None of the patients had been treated with the long-acting somatostatin analogs octreotide (Sandostatin LAR; Novartis) or lanreotide (Somatuline; Ipsen) during at least the last 6 wk before receiving 177Lu-DOTATOC or with short-acting octreotide (Sandostatin s.c.; Novartis) during the last 3 d before receiving 177Lu-DOTATOC.

Radiotracer

DOTATOC was synthesized as previously described (24). For radiolabeling DOTATOC, we used lyophilized kits containing DOTATOC, gentisic acid, inositol, and sodium ascorbate (pH 5.0).

We added 7,400 MBq of 177LuCl3 (IDB Holland BV) to the lyophilized DOTATOC kits and heated them for 30 min at 95°C. After they had been cooled to room temperature, a quality control check was performed using an analytic high-performance liquid chromatograph (model 1050; Hewlett Packard) with a radiometric detector (model LB 506 C1; Berthold). Additionally, the labeling yield was determined by separation of bound and free 177Lu3+ using Sep-Pak C18 cartridges (Waters). After 177Lu-DOTATOC had been loaded onto the cartridge, the free 177Lu was eluted with sodium acetate buffer (0.4 mol/L, pH 5.0), and bound 177Lu-DOTATOC was then eluted with methanol. Each fraction was measured on a γ-counter.

Treatment

The patients were hospitalized for 3 d in accordance with the legal requirements for radioactivity control. A single, fixed-activity treatment protocol was used. The injected activity was 7,400 MBq of 177Lu-DOTATOC. An infusion of 2,000 mL of an amino acid solution (Ringer’s lactated Hartmann solution, Proteinsteril [B. Braun Medical AG] HEPA 8%, Mg 5-Sulfat [B. Braun Medical AG]) to inhibit tubular reabsorption of the radiopeptide was started 30 min before administration of the radiopharmaceutical and was continued until up to 3 h after administration of the radiopharmaceutical (20,25,26).

Imaging and Dosimetry

Imaging was performed with a dual-head Prism 2000 XP camera (Picker) using parallel-hole, medium-energy, general-purpose collimators. The windows were centered over both 177Lu photon peaks (113 and 208 keV) with a window width of 20%. In 4 patients, whole-body scans for dosimetry were obtained immediately and at 4, 24, and 28 h after injection. The acquisition time for the whole-body scans was 15 min. In all other patients, whole-body scans and spot images were obtained after 24 and 28 h for control of biodistribution.

To determine blood clearance, we drew blood samples from 4 patients at 5, 10, 30, and 60 min and at 12, 4, 24, and 28 h after injection. Radioactivity in blood was measured with a γ-counter (Cobra II; Canberra-Packard).

For dosimetric calculations, regions of interest were drawn manually on the whole-body scans from anterior and posterior projections. Those parts of the kidneys showing tumor infiltration or superimposition were excluded from the evaluation of organ uptake. The Odyssey XP program (Philips Electronics N.V.) was used. Background regions were placed close to the regions of interest for background correction. The geometric mean value between anterior and posterior was taken and corrected for attenuation and physical decay. Whole-body activity acquired immediately after injection was defined as 100% of the injected activity. Data were expressed as percentage injected activity as a function of time. The resulting time–activity data were fitted to a monoexponential curve for the whole-body clearance and to a biexponential curve for the kidneys to calculate residence time. Published radiation dose factors were used to calculate the absorbed doses (27).

The activity in blood was fitted to a biexponential curve to determine the residence time in blood. The dose to the red marrow was calculated from the residence time in blood, assuming no specific uptake, a uniform distribution of activity, and clearance from red marrow equal to that from blood. A correction factor of 1 was used as described by Cremonesi et al. (28).

Evaluation of Results and Assessment of Clinical Benefit

Pretherapeutically, patients underwent disease staging. Eight to 12 wk after peptide receptor–mediated radionuclide therapy, tumor growth and tumor response were monitored by CT or ultrasound. Tumor response was defined according to the WHO standard criteria. In addition, complete blood cell and platelet counts were obtained every 2 wk for at least 8 wk or until resolution of nadir. Side effects were scored according to the WHO criteria.

Statistics

Paired t testing was used to determine statistical significance. Differences at the 95% confidence level (P < 0.05) were considered significant.

RESULTS

The study included 27 patients with metastasized tumors, 11 of whom had neuroendocrine pancreatic tumors and 16, neuroendocrine tumors of other sites (7 of the small bowel, 4 of unknown primary, 2 of the rectum, 1 of the stomach, 1 of the bronchus, and 1 of the appendix). Detailed patient characteristics are listed in Table 1.

Evaluation of Long-Term Outcome After 90Y-DOTATOC Therapy

All patients had progressive disease before 90Y-DOTATOC therapy and before 177Lu-DOTATOC therapy. One criterion for inclusion into this study was benefit from 90Y-DOTATOC therapy. Of the 27 patients studied, we found a partial remission in 14, a minor response in 3, and stable disease in 10 at 3 mo after the last treatment with 90Y-DOTATOC.

The mean time between the last treatment with 90Y-DOTATOC and the treatment with 177Lu-DOTATOC was 15.4 ± 7.8 mo (range, 4–32 mo).

Before therapy with 90Y-DOTATOC, the mean hemoglobin level was 131 ± 14 g/L, the mean thrombocyte level was 306 ± 123 × 109/L, and the mean creatinine level was 66 ± 14 μmol/L. Before treatment with 177Lu-DOTATOC, the level of hemoglobin was significantly lower: 117 ± 13 g/L (P < 0.0001). The thrombocyte counts (263 ± 83 × 109/L) were lower as well but did not show significant changes. Creatinine levels increased to 100 ± 44 μmol/L. The difference was significant (P < 0.0001), although a high SD was seen. Details are listed in Table 2.

View this table:
  • View inline
  • View popup
TABLE 2

Blood Values and Clinical Results

Labeling of 177Lu-DOTATOC

The quality control testing of 177Lu-DOTATOC was done using 2 independent systems; the labeling efficiency was determined by analytic high-performance liquid chromatography and ranged from 99% to 100%. When the labeling yield was less than 99.5%, DTPA (1 mmol/L, pH 7.4) was added.

Dosimetry

Dosimetric calculations were performed on 4 patients and resulted in a mean whole-body absorbed dose of 413 ± 159 mGy. The mean absorbed dose to the kidney was 3.1 ± 1.5 Gy, and that to the red marrow was 61 ± 5 mGy.

Treatment with 177Lu-DOTATOC

The treatment was well tolerated. No severe adverse events occurred. Nausea and vomiting within the first 24 h after treatment occurred in 8 patients (30%). All cases of nausea and vomiting could be treated successfully with domperidone and ondansetron. Some increase of pain at the site of the tumor was experienced by 5 patients (19%) within the first 48 h after treatment. All cases could be controlled with analgesics. No other nonhematologic toxicity was found.

As expected. 177Lu-DOTATOC showed a high specific uptake in somatostatin receptor–positive tumors. The γ-component of 177Lu allowed acquisition of scintigraphic images of a high level of quality (Fig. 1A).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Anterior whole-body scans of patient 9. (A) Scan obtained 24 h after injection of 7,400 MBq of 177Lu-DOTATOC shows several abdominal metastases (liver, spleen, and lymph nodes). (B) Scan obtained 6 h after injection of 185 MBq 111In-Octreoscan 6 mo after treatment with 7,400 MBq of 177Lu-DOTATOC shows a decrease in tumor load. Especially, a reduction of liver metastases can be seen.

At the time of restaging, we found no change in creatinine levels. With these findings, late nephrotoxicity cannot be excluded definitely. But if nephrotoxicity arises, an increase in creatinine levels has usually been found 3 mo after treatment (16). Before treatment, 9 patients had grade 1 anemia and 1 had grade 2. Eight to 12 wk after treatment, 8 patients had grade 1 anemia, 1 had grade 2, and 1 had grade 3. The mean level of thrombocytes decreased significantly, from 263 ± 82 to 197 ± 70 × 109/L (P < 0.01). Details are listed in Table 2.

Eight to 12 wk after treatment, 8 patients did not show a benefit from peptide receptor–mediated radionuclide therapy and continued to have progressive disease. Nineteen patients (70%) showed a benefit: 12 with stabilization of the disease, 5 with a minor response, and 2 with partial remission. Scans of patient 9, with a minor response, are shown in Figure 1, and corresponding anatomic images are shown in Figure 2. According to the referring physicians, the general condition of the patients improved for 15 (56%), remained the same for 11 (41%), and decreased for only 1 (4%).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

CT scans of patient 9. (A) Nine months after treatment with 90Y-DOTATOC and 4 wk before treatment with 177Lu-DOTATOC, CT scan shows multiple liver metastases. (B) Corresponding CT scan 4 mo after treatment with 177Lu-DOTATOC shows minor response.

The subgroup of patients who achieved partial remission after 90Y-DOTATOC (n = 14) included 2 with partial remission, 5 with a minor response, and 7 with stable disease after 177Lu-DOTATOC treatment. In no patient of this subgroup did the disease remain progressive.

The overall time of follow-up was 4–17 mo (mean, 11.0 ± 4.0 mo). The time of remission (stable disease, minor response, or partial remission) ranged from 4 to 13 mo (mean, 8.3 ± 3.4 mo). Presently, 8 patients are still without disease progression; therefore, the overall time to progression will increase further.

DISCUSSION

The labeling of 177Lu-DOTATOC was straightforward, and its application was safe. No serious adverse events occurred.

The group of 27 patients was selected from patients treated earlier with 90Y-DOTATOC; all showed stable disease, a minor response, or partial remission after treatment but experienced relapse rather early and a short time to progression (15 ± 7.8 mo) The time to progression after treatment with 90Y-DOTATOC in these patients was shorter than has been reported in the literature (18).

The absorbed doses to normal organs, especially to the kidneys, were low. In previous clinical trials, a cumulative absorbed dose to the kidneys of 23 or 27 Gy was taken as the maximum tolerated dose (11,26,29). But these values are controversial (30) because they are derived from external-beam radiation (31) with a potentially different mechanism. The low absorbed doses are compatible with the fact that no increase of creatinine levels was found.

When the clinical results after 177Lu-DOTATOC are correlated with the clinical results after 90Y-DOTATOC, a good response after 90Y-DOTATOC (partial remission in our patients) is obviously a positive prognostic factor for further radionuclide treatment. Some tumors seem to be especially suited for peptide receptor–mediated radionuclide therapy. Two reasons are possible: There could be a high density of somatostatin receptors leading to a high radiation-absorbed dose, or there could be some tumors that are more radiosensitive than others.

The general condition of the patients was not scaled before treatment with 177Lu-DOTATOC but was worse than before the first treatment with 90Y-DOTATOC because all patients had a longer history of illness and experienced progression after remission or stabilization after 90Y-DOTATOC therapy. The total amount of injected activity (fixed activity, 7,400 MBq of 177Lu-DOTATOC) was rather low because we included patients with an increased serum creatinine level or with a diminished hemoglobin level.

The toxicity in patients with increased creatinine or diminished hemoglobin levels was not different from that in patients with normal values. We found no severe toxicity and, especially, no increase of creatinine levels. Therefore, we conclude that the treatment with 177Lu-DOTATOC in cases of relapse after treatment with 90Y-DOTATOC is feasible and safe. Clinical improvement could be observed, and most patients benefited from the treatment.

With regard to the radiobiologic mechanisms of 177Lu and 90Y, the combination of the 2 radionuclides could improve the biologic efficiency. The high-energy β-emitter 90Y deposits high doses to tumors and also to areas with low target protein expression and to heterogeneous tumor tissue. Because of the strong crossfire effect, parts of the tumor that either are poorly differentiated and therefore have a low density of somatostatin receptors or are poorly vascularized can be reached. 177Lu, on the other hand, seems to have more favorable physical characteristics for the treatment of small tumors (32–34).

Another mechanism that is not well defined is the so-called low-dose hypersensitivity-inducible radioresistance hypothesis as described by Joiner et al. (35). The administration of only a low absorbed dose at a low dose rate might be more effective in inducing tumor cell death than are higher absorbed doses.

CONCLUSION

Treatment with 177Lu-DOTATOC of patients who were pretreated with 90Y-DOTATOC is feasible and appears to be safe even when patients present with grade 1 or 2 hematotoxicity or nephrotoxicity. Clinical response at a low injected activity is promising. A good response after treatment with 90Y-DOTATOC is a positive predictor for successful treatment with 177Lu-DOTATOC.

Acknowledgments

We thank all supporting personnel of the Division of Radiologic Chemistry and the Institute of Nuclear Medicine for their expert help and effort, and we gratefully thank Martin Speiser and Marlies Meury for technical assistance and nursing. We are indebted to Daniela Biondo, Priska Preisig, Nadia Mutter, Pia Powell, and Stefan Good for nuclear pharmacy support. This work was supported by the Swiss National Science Foundation (grant 31-452969/97) and was performed within the COST B12 action.

Footnotes

  • Received Dec. 20, 2004; revision accepted Apr. 7, 2005.

    For correspondence or reprints contact: Flavio Forrer, MD, Institute of Nuclear Medicine, University Hospital Basel, Petersgraben 4, CH-4031 Basel, Switzerland.

    E-mail: fforrer{at}uhbs.ch

REFERENCES

  1. ↵
    Faiss S, Pape UF, Bohmig M, et al. International lanreotide and interferon alfa study group: prospective, randomized, multicenter trial on the antiproliferative effect of lanreotide, interferon alfa, and their combination for therapy of metastatic neuroendocrine gastroenteropancreatic tumors. J Clin Oncol. 2003;21:2689–2696.
    OpenUrlAbstract/FREE Full Text
  2. Kaltsas GA, Mukherjee JJ, Isidori A, et al. Treatment of advanced neuroendocrine tumours using combination chemotherapy with lomustine and 5-fluorouracil. Clin Endocrinol (Oxf). 2002;57:169–183.
    OpenUrlCrossRefPubMed
  3. ↵
    Moertel CG, Kvols LK, O’Connell MJ, et al. Treatment of neuroendocrine carcinomas with combined etoposide and cisplatin: evidence of major therapeutic activity in the anaplastic variants of these neoplasms. Cancer. 1991;68:227–232.
    OpenUrlCrossRefPubMed
  4. ↵
    Dharmsathaphorn K, Sherwin RS, Cataland S, et al. Somatostatin inhibits diarrhea in the carcinoid syndrome. Ann Intern Med. 1980;92:68–69.
  5. ↵
    Vinik A, Moattari AR. Use of somatostatin analog in management of carcinoid syndrome. Dig Dis Sci 1989;34.(suppl 3):14S–27S.
  6. ↵
    Anthony LB, Martin W, Delbeke D, et al. Somatostatin receptor imaging: predictive and prognostic considerations. Digestion. 1996;57.(suppl 1):50–53.
  7. ↵
    Waldherr C, Pless M, Maecke H, et al. Tumor response and clinical benefit in neuroendocrine tumors after 7.4 GBq 90Y-DOTATOC. J Nucl Med. 2002;43:610–616.
    OpenUrlAbstract/FREE Full Text
  8. Paganelli G, Bodei L, Handkiewicz Junak D, et al. 90Y-DOTA-D-Phe1-Try3-octreotide in therapy of neuroendocrine malignancies. Biopolymers. 2002;66:393–398.
    OpenUrlCrossRefPubMed
  9. ↵
    Otte A, Herrmann R, Heppeler A, et al. Yttrium-90 DOTATOC: first clinical results. Eur J Nucl Med. 1999;26:1439–1447.
    OpenUrlCrossRefPubMed
  10. ↵
    Waldherr C, Pless M, Maecke HR, et al. The clinical value of [90Y-DOTA]-D-Phe1-Tyr3-octreotide (90Y-DOTATOC) in the treatment of neuroendocrine tumours: a clinical phase II study. Ann Oncol. 2001;12:941–945.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    Kwekkeboom D, Bakker W, Kam BLR, et al. Treatment of patients with gastro-entero-pancreatic (GEP) tumours with the novel radiolabelled somatostatin analogue [177Lu-DOTA0,Tyr3]octreotate. Eur J Nucl Med. 2003;30:417–422.
    OpenUrl
  12. ↵
    Anthony LB, Woltering EA, Espanan GD, et al. Indium-111-pentetreotide prolongs survival in gastroenteropancreatic malignancies. Semin Nucl Med. 2002;32:123–132.
    OpenUrlCrossRefPubMed
  13. ↵
    Valkema R, de Jong M, Bakker WH, et al. Phase I study of peptide receptor radionuclide therapy with [111In-DTPA0]octreotide: the Rotterdam experience. Semin Nucl Med. 2002;32:110–122.
    OpenUrlCrossRefPubMed
  14. ↵
    Teunissen J, Kwekkeboom D, Krenning E. Quality of life in patients with gastro-entero-pancreatic tumors treated with [177Lu-DOTA0,Tyr3]octreotate. J Clin Oncol. 2004;22:2724–2729.
    OpenUrlAbstract/FREE Full Text
  15. ↵
    Krenning EP, Kwekkeboom DJ, Valkema, et al. Peptide receptor radionuclide therapy. Ann N Y Acad Sci. 2004;1014:234–245.
    OpenUrlCrossRefPubMed
  16. ↵
    Moll S, Nickeleit V, Mueller-Brand J, et al. A new cause of renal thrombotic microangiopathy: Yttrium-90-DOTATOC internal radiotherapy. Am J Kidney Dis. 2001;37:847–851.
    OpenUrlPubMed
  17. ↵
    Valkema R, Pauwels S, Kvols L, et al. Long-term follow-up of a phase 1 study of peptide receptor radionuclide therapy (PRRT) with [90Y-DOTA0,Tyr3]octreotide in patients with somatostatin receptor positive tumours [abstract]. Eur J Nucl Med Mol Imaging. 2003;30.(suppl 2):S232.
  18. ↵
    Kwekkeboom DJ, Mueller-Brand J, Paganelli G, et al. Overview of results of peptide receptor radionuclide therapy with 3 radiolabeled somatostatin analogs. J Nucl Med. 2005;46.(suppl 1):62S–66S.
  19. ↵
    Kwekkeboom DJ, Bakker WH, Teunissen JJM, et al. Treatment with Lu-177-DOTA-Tyr3-octreotate in patients with neuroendocrine tumors: interim results [abstract]. Eur J Nucl Med Mol Imaging. 2003;30.(suppl 2):S231.
  20. ↵
    Behr TM, Goldenberg DM, Becker W. Reducing the renal uptake of radiolabeled antibody fragments and peptides for diagnosis and therapy: present status, future prospects and limitations. Eur J Nucl Med. 1998;25:201–212.
    OpenUrlCrossRefPubMed
  21. ↵
    Konijnenberg MWE, Bijster M, Krenning E, et al. A stylized computational model of the rat for organ dosimetry in support of preclinical evaluations of peptide receptor radionuclide therapy with 90Y, 111In, or 177Lu. J Nucl Med. 2004;45:1260–1269.
    OpenUrlAbstract/FREE Full Text
  22. ↵
    Reubi J, Schaer J, Waser B, et al. Affinity profiles for human somatostatin receptor subtypes SST1-SST5 of somatostatin radiotracers selected for scintigraphic and radiotherapeutic use. Eur J Nucl Med. 2000;27:273–282.
    OpenUrlCrossRefPubMed
  23. ↵
    Forrer F, Uusijärvi H, Waldherr C, et al. A comparison of 111In-DOTATOC and 111In-DOTATATE: biodistribution and dosimetry in the same patients with metastatic neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2004;31:1257–1262.
    OpenUrlPubMed
  24. ↵
    Wild D, Schmitt JS, Ginj M, et al. DOTA-NOC, a high-affinity ligand of somatostatin receptor subtypes 2, 3 and 5 for labelling with various radiometals. Eur J Nucl Med Mol Imaging. 2003;30:1338–1347.
    OpenUrlCrossRefPubMed
  25. ↵
    Rolleman EJ, Valkema R, de Jong M, et al. Safe and effective inhibition of renal uptake of radiolabelled octreotide by a combination of lysine and arginine. Eur J Nucl Med Mol Imaging. 2003;30:9–15.
    OpenUrlCrossRefPubMed
  26. ↵
    Jamar F, Barone R, Mathieu I, et al. 86Y-DOTA0-D-Phe1-Tyr3-octreotide (SMT487): a phase 1 clinical study—pharmacokinetics, biodistribution and renal protective effect of different regimens of amino acid co-infusion. Eur J Nucl Med Mol Imaging. 2003;30:510–518.
    OpenUrlPubMed
  27. ↵
    RADAR medical procedure radiation dose calculator and consent language generator. Stanford Dosimetry, LLC, Web site. Available at: http://www.doseinfo-radar.com/RADARDoseRiskCalc.html. Accessed June 6, 2005.
  28. ↵
    Cremonesi M, Ferrari M, Zoboli S, et al. Biokinetics and dosimetry in patients administered with 111In-DOTA-Tyr3-octreotide: implications for internal radiotherapy with 90Y-DOTATOC. Eur J Nucl Med. 1999;26:877–886.
    OpenUrlCrossRefPubMed
  29. ↵
    Helisch A, Forster GJ, Reber H, et al. Pre-therapeutic dosimetry and biodistribution of 86Y-DOTA-Phe1-Tyr3-octreotide versus 111In-pentetreotide in patients with advanced neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2004;31:1386–1392.
    OpenUrlPubMed
  30. ↵
    Forrer F, Mueller-Brand J, Maecke H. Pre-therapeutic dosimetry with radiolabelled somatostatin analogues in patients with advanced neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2005;32:511–512.
    OpenUrlPubMed
  31. ↵
    Emami B, Lyman J, Brown A, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 1991;21:109–122.
    OpenUrlPubMed
  32. ↵
    Bernhardt P, Forssell-Aronsson E, Jacobsson L, et al. Low-energy electron emitters for targeted radiotherapy of small tumours. Acta Oncol. 2001;40:602–608.
    OpenUrlCrossRefPubMed
  33. de Jong M, Breeman WA, Bernard BF, et al. [177Lu-DOTA0,Tyr3] octreotate for somatostatin receptor-targeted radionuclide therapy. Int J Cancer. 2001;92:628–633.
    OpenUrlCrossRefPubMed
  34. ↵
    Capello A, Krenning EP, Breeman WA, et al. Tyr3-octreotide and Tyr3-octreotate radiolabeled with 177Lu or 90Y: peptide receptor radionuclide therapy results in vitro. Cancer Biother Radiopharm. 2003;18:761–768.
    OpenUrlPubMed
  35. ↵
    Joiner MC, Marples B, Lambin P, et al. Low-dose hypersensitivity: current status and possible mechanisms. Int J Radiat Oncol Biol Phys. 2001;49:379–389.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 46 (8)
Journal of Nuclear Medicine
Vol. 46, Issue 8
August 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Treatment with 177Lu-DOTATOC of Patients with Relapse of Neuroendocrine Tumors After Treatment with 90Y-DOTATOC
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Treatment with 177Lu-DOTATOC of Patients with Relapse of Neuroendocrine Tumors After Treatment with 90Y-DOTATOC
Flavio Forrer, Helena Uusijärvi, Daniel Storch, Helmut R. Maecke, Jan Mueller-Brand
Journal of Nuclear Medicine Aug 2005, 46 (8) 1310-1316;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Treatment with 177Lu-DOTATOC of Patients with Relapse of Neuroendocrine Tumors After Treatment with 90Y-DOTATOC
Flavio Forrer, Helena Uusijärvi, Daniel Storch, Helmut R. Maecke, Jan Mueller-Brand
Journal of Nuclear Medicine Aug 2005, 46 (8) 1310-1316;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • THIS MONTH IN JNM
  • PubMed
  • Google Scholar

Cited By...

  • Reimbursement Approaches for Radiopharmaceutical Dosimetry: Current Status and Future Opportunities
  • Twelve-Year Follow-up After Peptide Receptor Radionuclide Therapy
  • Parametric Net Influx Rate Images of 68Ga-DOTATOC and 68Ga-DOTATATE: Quantitative Accuracy and Improved Image Contrast
  • Dose Response of Pancreatic Neuroendocrine Tumors Treated with Peptide Receptor Radionuclide Therapy Using 177Lu-DOTATATE
  • Targeted Radionuclide Therapy: Proceedings of a Joint Workshop Hosted by the National Cancer Institute and the Society of Nuclear Medicine and Molecular Imaging
  • Radiopeptide Imaging and Therapy in Europe
  • Nuclear medicine techniques for the imaging and treatment of neuroendocrine tumours
  • Response and Long-Term Control of Bone Metastases After Peptide Receptor Radionuclide Therapy with 177Lu-Octreotate
  • Dynamic and Static Small-Animal SPECT in Rats for Monitoring Renal Function After 177Lu-Labeled Tyr3-Octreotate Radionuclide Therapy
  • Salvage Therapy with 177Lu-Octreotate in Patients with Bronchial and Gastroenteropancreatic Neuroendocrine Tumors
  • 68Ga-DOTA-Tyr3-Octreotide PET for Assessing Response to Somatostatin-Receptor-Mediated Radionuclide Therapy
  • Electron- and Positron-Emitting Radiolanthanides for Therapy: Aspects of Dosimetry and Production
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire