Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherCLINICAL INVESTIGATIONS

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated 99mTc-Sestamibi Myocardial SPECT

Jin Chul Paeng, Dong Soo Lee, Gi Jeong Cheon, Myoung Mook Lee, June-Key Chung and Myung Chul Lee
Journal of Nuclear Medicine May 2001, 42 (5) 695-700;
Jin Chul Paeng
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dong Soo Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gi Jeong Cheon
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Myoung Mook Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
June-Key Chung
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Myung Chul Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

We investigated the reproducibility of an automatic quantitative algorithm for measuring regional myocardial wall motion and systolic thickening. Methods: 99mTc-sestamibi gated myocardial SPECT with dipyridamole stress was performed twice consecutively on 31 patients with known or suspected coronary artery disease, with the patients in the same position for each scan. With AutoQUANT software, segmental wall motion and systolic thickening were quantified automatically and expressed in millimeters and percentage increase, respectively, for 20 segments. Afterward, the correlation and agreement between repeated measurements were investigated, and the influences of wall location, perfusion grade, and partitioning of the myocardium on reproducibility were evaluated by ANOVA and t testing. Results: High correlations (r = 0.95 for wall motion and 0.88 for systolic thickening) and good agreements (weighted κ = 0.81 and 0.71, respectively) were obtained from repeated measurements on consecutive gated SPECT. Changes in wall location and perfusion grade did not cause significant differences between repeated measurements (P > 0.05 in ANOVA and t testing), but a change in partitioning did. On Bland–Altman analysis, 2 SDs for repeated wall motion and for systolic thickening were 2.0 mm and 20%, respectively. Conclusion: The automatic quantitative algorithm for myocardial SPECT provided by AutoQUANT software has good reproducibility under diverse conditions. A change of motion > 2.0 mm or a change of systolic thickening > 20% can be regarded as significant during a follow-up study using this software.

  • 99mTc-sestamibi SPECT
  • automatic quantitation
  • reproducibility

Regional myocardial function and perfusion are important in coronary artery disease because they indicate myocardial viability and predict prognosis after revascularization at the regional level (1–3). Myocardial wall motion and systolic thickening are frequently used parameters for regional myocardial function. They can be assessed by several methods, such as gated SPECT, echocardiography, or cine MRI (4–7). With gated SPECT, myocardial function and perfusion can be assessed simultaneously (8), and the findings have a reputation of reliability compared with those of other methods (9–11).

Algorithms extracting myocardial boundaries from end-systolic and end-diastolic images have improved the assessment of regional myocardial function on gated SPECT (12,13). On the basis of those algorithms, Germano et al. (14) proposed a new algorithm for the automatic quantitation of myocardial wall motion and systolic thickening on gated SPECT and reported that the algorithm agreed well with visual assessment. The algorithm provides quantitative values without manual intervention, whereas most visual assessment is semiquantitative. This automatic algorithm also has the advantage of being independent of the observer’s subjectivity. When an automatic algorithm provides consistent measurements from a gated SPECT image, the algorithm can be considered to provide almost perfect intraobserver reproducibility.

However, the reproducibility of measurements acquired under the same conditions is also important, and normal variations between conditions should be investigated (15). This point is particularly critical when gated SPECT is used for a follow-up study or for evaluating the effect of some treatment. The same clinical condition can be assumed if data are acquired from a patient consecutively in a short time without any intervening treatment or change of position. In this study, gated SPECT images were acquired in that manner, and myocardial motion and systolic thickening were quantified using software incorporating the automatic algorithm.

Reproducibility should be guaranteed under diverse clinical conditions. Several factors may interfere with the interpretation of SPECT images. Attenuation affects image quality and the interpretation of myocardial SPECT (16,17). Each wall location has different attenuation characteristics, and these may affect images. Decreased perfusion makes extraction of myocardial boundaries difficult (18). Partitioning is a process in the automatic algorithm itself and is an important factor when assessing regional parameters.

In this study, the reproducibility of the automatic algorithm for measuring regional myocardial motion and systolic thickening was investigated. The influences of some likely affecting factors, such as wall location, perfusion, and partitioning of the myocardium, on reproducibility were also evaluated.

MATERIALS AND METHODS

Patient Population

Thirty-one patients (23 men, 8 women; age range, 32–73 y; mean age ± SD, 59.2 ± 9.7 y) with known or suspected coronary artery disease were enrolled in this study. Four patients had a history of old myocardial infarction (20 ± 14 mo before study), and another 4 patients had a history of recent myocardial infarction (12 ± 7 d before study). Coronary angiography was performed on 21 patients, and all had coronary artery stenosis occluding more than 50% of the intravascular diameter (4 of a single vessel, 6 of 2 vessels, and 11 of 3 vessels). The stenosis was in the left anterior descending artery in 19 patients, in the left circumflex artery in 15 patients, and in the right coronary artery in 15 patients. Five patients had a history of coronary artery bypass grafting, and another 5 patients had a history of percutaneous transluminal coronary angioplasty before the study. Left ventricular ejection fraction was 51% ± 14%, and end-systolic volume was 65 ± 40 mL.

Image Acquisition

During dipyridamole stress, 925 MBq 99mTc-sestamibi were injected. After 1 h, gated 99mTc-sestamibi SPECT was performed and another acquisition was obtained consecutively without any intervening treatment or change of patient positioning (Fig. 1). Sixteen frames of data according to the averaged cardiac cycle were acquired with a 40% window centered over the 140-keV photopeak, using a dual-head 90° camera (Vertex; ADAC Laboratories, Milpitas, CA). A ramp filter and a Butterworth low-pass filter of order 5 and cutoff frequency 0.33 cycle/pixel were used for backprojection. No attenuation or scatter correction was done, and tomographic transaxial images and gated surface images were reconstructed from the backprojection.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Procedure for dipyridamole stress 99mTc-sestamibi (MIBI) gated SPECT. Scanning was performed twice consecutively in short time without change of position.

Automatic Quantitation

The myocardium was divided into 20 segments (Fig. 2). In each of the 20 segments, the average quantitative values of segmental wall motion and systolic thickening were determined using AutoQUANT software (ADAC Laboratories). Wall motion was calculated and expressed in millimeters, and systolic thickening was expressed as percentage of end-diastolic wall thickness. The entire process was performed automatically, without manual intervention.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Myocardium was partitioned into 20 segments. Apex was divided into 2 segments, and apical, mid, and basal regions were divided into 6 segments each. For assessment of influence of wall location, segments were classified into 5 wall locations. Each pattern represents different wall location.

The influence of partitioning on reproducibility was evaluated by repartitioning the myocardium into 5 regions (apex, anterior, lateral, inferior, and septal walls), and average regional motion and systolic thickening were also quantified in each of these regions. These measurements were also acquired automatically using AutoQUANT software.

Perfusion Grading

For each of the 20 segments, perfusion was evaluated automatically using AutoQUANT software, which awarded a quantitative value and scored the segment according to a 5-grade system (0 through 4). This algorithm has been reported to have good reproducibility and clinical relevance (19,20).

Statistical Analysis

Reproducibility was checked through calculation of correlation coefficients between repeated measurements. Because the correlation coefficient cannot properly represent agreement, weighted κ values were also calculated. For this calculation, the quantified values were scored using a 5-grade system for wall motion (0 = ≥6 mm, 1 = 4–5.9 mm, 2 = 2–3.9 mm, 3 = 0–1.9 mm, and 4 = <0 mm [Table 1]) and using a 4-grade system for systolic thickening (0 = ≥40%, 1 = 20%–40%, 2 = 10%–20%, and 3 = <10%). The range of differences between repeated measurements was shown on a Bland–Altman plot, and 2 SDs of the differences were calculated.

View this table:
  • View inline
  • View popup
TABLE 1

Agreement of Segmental Motion Grades from Automatic Quantified Values on Repeated Gated SPECT

ANOVA was performed to evaluate the influences of wall location and perfusion status. Twenty segments were classified into 5 wall locations (Fig. 2), and ANOVA was performed on the absolute differences between repeated measurements, setting wall location as an effect factor. ANOVA was also performed with perfusion grade set as an effect factor, and t testing was performed to evaluate the influence of myocardial partitioning. In every analysis, P < 0.05 was considered significant, and κ values were graded as follows: 0–0.20 = slight, 0.21–0.40 = moderate, 0.41–0.60 fair, and 0.61–1.00 = good to perfect (21).

RESULTS

General Reproducibility of Quantified Values

The mean value of myocardial wall motion was 5.9 ± 3.0 mm (range, −3.6 to 13.7 mm), and the correlation coefficient between repeated measurements was 0.95 (Fig. 3A). The Bland–Altman plot showed no deviation in dispersion of differences according to the means of their motion values, and 2 SDs of the differences covered a range of ±2.0 mm (Fig. 3B).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Correlation of automatic quantitation of motion on repeated gated SPECT (A) and Bland–Altman plotting of motion (B).

Mean systolic thickening was 34% ± 20% (range, −5% to 103%), and the correlation coefficient between repeated measurements was 0.88 (Fig. 4A). No deviation of dispersion occurred, and 2 SDs covered a range of ±20% (Fig. 4B).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Correlation of automatic quantitation of systolic thickening on repeated gated SPECT (A) and Bland–Altman plotting of systolic thickening (B).

κ values also exhibited good reproducibility. The weighted κ values for agreement between repeated measurements were 0.81 (95% confidence interval, 0.78–0.84) for wall motion (Table 1) and 0.71 (95% confidence interval, 0.67–0.75) for systolic thickening (Table 2), which represented good to perfect agreements.

View this table:
  • View inline
  • View popup
TABLE 2

Agreement of Segmental Thickening Grades from Automatic Quantified Values on Repeated Gated SPECT

Influence of Wall Location

The correlation coefficients for each wall location are shown in Table 3. Although those for systolic thickening in the septal and inferior walls were relatively low, the overall correlation was good in every location. The absolute differences between repeated measurements according to wall location are shown in Figure 5. By ANOVA, setting wall location as an effect factor, no significant distinction was found among wall locations. To take into account the different characteristics of the attenuation pattern between men and women, we performed the same analysis for each sex group. However, neither group showed significant distinction by wall location (Table 4).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Means and confidence intervals (CI) of absolute differences between repeated measurements for wall motion (A) and for systolic thickening (B) according to wall locations. Ant = anterior wall; Inf = inferior wall; Lat = lateral wall; Sept = septal wall.

View this table:
  • View inline
  • View popup
TABLE 3

Correlation Coefficients Between Repeated Measurements of Segmental Motion and Thickening in Each Wall Location and Perfusion Grade

View this table:
  • View inline
  • View popup
TABLE 4

Probability Values on ANOVA, Setting Wall Location or Perfusion Grade as an Effect Factor

Influence of Perfusion

When segments were classified by perfusion grade, 384 segments were grade 0, 108 were grade 1, 69 were grade 2, 32 were grade 3, and 27 were grade 4. The measurements of motion and thickening in each group are tabulated in Table 5. The correlation coefficients in each perfusion grade are shown in Table 3. Both segmental motion and systolic thickening correlated well between repeated measurements. Absolute differences according to perfusion grade are illustrated in Figure 6. Setting perfusion grade as an effect factor, the ANOVA of absolute differences between repeated measurements showed no significant distinction among the perfusion groups for either wall motion or systolic thickening. This finding was retested for each sex group. In this analysis, no significant distinction was found (Table 4).

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Means and confidence intervals (CI) of absolute differences between repeated measurements for wall motion (A) and for systolic thickening (B) according to perfusion grade. Higher grade represents more severe perfusion decrease.

View this table:
  • View inline
  • View popup
TABLE 5

Measurements of Motion and Thickening According to Perfusion Grade

Influence of Partitioning

In segmental data, the absolute differences between repeated measurements were 0.77 ± 0.62 mm for wall motion and 7.2% ± 7.2% for systolic thickening. After the myocardium was repartitioned into 5 wall regions, wall motion and systolic thickening were assessed in each region. The absolute differences were 0.52 ± 0.49 mm for wall motion and 4.5% ± 3.7% for systolic thickening. The absolute differences between the 2 groups were significant on t testing (P < 0.001). Partitioning the myocardium into larger regions showed smaller absolute differences between repeated measurements.

DISCUSSION

This study showed good reproducibility for the automatic quantitation of regional myocardial motion and systolic thickening. In consecutive studies using quantitative gated SPECT software (Cedars-Sinai Medical Center, Los Angeles, CA), the reproducibility of the visual assessment of myocardial motion and thickening was reported to have κ values of 0.76 and 0.87, respectively (22). The automatic algorithms investigated in this study showed similar results. Both motion and thickening showed high agreement for repeated measurements.

Visual assessment of motion or thickening was reported to be less reproducible for dysfunctional myocardium than for normal myocardium (23). However, the Bland–Altman plot in this study showed no distinction between groups with better functioning and groups with worse functioning, meaning that the functional status does not affect the reproducibility of this algorithm. This advantage is another benefit of the automatic algorithm.

Patterns of attenuation differ with wall location (24); moreover, myocardial motion and systolic thickening have been reported to show different normal variations according to wall location (25). Nevertheless, this study showed no significant distinction between segments in different wall locations. In addition, no distinction was found between different perfusion groups. Although the probability value was near 0.05 and Figure 6 displays some distinctive patterns between the various perfusion groups, these patterns seemed to be the result of some factor other than lower perfusion, because the group with worse perfusion showed the lower absolute differences. The fewer segments in the higher grade may have caused this result. A decreased radioactivity count caused by decreased perfusion or attenuation induces artifacts such as the partial-volume effect and makes the interpretation of the gated SPECT images difficult by both visual assessment and automatic algorithms (18,26). However, the perfusion and wall motion did not affect the reproducibility in this study.

Partitioning is an intra-algorithmic process composed of the reorientation of the acquired image and section. This process is one of the critical points in the automatic interpretation of myocardial SPECT (27,28). After the partitioning into larger regions, absolute differences between repeated measurements and their SDs decreased to a statistically significant degree. Therefore, improvement of the partitioning process will likely improve reproducibility.

Another concern of this study was normal variation in repeated measurements. To follow up a patient or evaluate the effect of treatment, we need to determine changes in myocardial function. Two SDs of differences between repeated measurements were ±2 mm for motion and ±20% for systolic thickening. One study found that 2 SDs of interobserver differences for systolic thickening were ±16%, when assessed using an automatic algorithm that extracts myocardial boundaries in echocardiography (29). Considering that those results were not obtained at the segmental level, they seem to be similar to the results of our study.

CONCLUSION

The automatic algorithm for quantitation of regional myocardial wall motion and systolic thickening showed good reproducibility and was not affected by such factors as myocardial functional status, attenuation, and perfusion. The absolute difference between repeated measurements was significantly decreased by a change in partitioning. Therefore, this algorithm can reliably be applied to diverse clinical conditions, but the partitioning process needs further discretion. Finally, when this algorithm is used in follow-up studies or in evaluating the effect of some management, changes in motion more than 2.0 mm and changes in systolic thickening more than 20% can be regarded as significant.

Footnotes

  • Received Nov. 20, 2000; revision accepted Mar. 16, 2001.

    For correspondence or reprints contact: Dong Soo Lee, MD, PhD, Department of Nuclear Medicine, Seoul National University College of Medicine, 28 Yungundong Chongno-gu, Seoul, 110-744, Korea.

REFERENCES

  1. ↵
    Iskander S, Iskandrian AE. Prognostic utility of myocardial viability assessment. Am J Cardiol. 1999;83:696–702.
    OpenUrlCrossRefPubMed
  2. Caner B, Beller GA. Are technetium-99m-labeled myocardial perfusion agents adequate for detection of myocardial viability? Clin Cardiol. 1998;21:235–242.
    OpenUrlPubMed
  3. ↵
    Baer FM, Theissen P, Schneider CA, et al. Dobutamine magnetic resonance imaging predicts contractile recovery of chronically dysfunctional myocardium after successful revascularization. J Am Coll Cardiol. 1998;31:1040–1048.
    OpenUrlCrossRefPubMed
  4. ↵
    Haendchen RV, Wyatt HL, Maurer G, et al. Quantitation of regional cardiac function by two-dimensional echocardiography. I. Patterns of contraction in the normal left ventricle. Circulation. 1983;67:1234–1245.
    OpenUrlAbstract/FREE Full Text
  5. Buda AJ, Zotz RJ, Pace DP, Krause LC. Comparison of two-dimensional echocardiographic wall motion and wall thickening abnormalities in relation to the myocardium at risk. Am Heart J. 1986;111:587–592.
    OpenUrlCrossRefPubMed
  6. Sechtem U, Pflugfelder P, Higgins CB. Quantification of cardiac function by conventional and cine magnetic resonance imaging. Cardiovasc Intervent Radiol. 1987;10:365–373.
    OpenUrlPubMed
  7. ↵
    Higgins CB, Holt W, Pflugfelder P, Sechtem U. Functional evaluation of the heart with magnetic resonance imaging. Magn Reson Med. 1988;6:121–139.
    OpenUrlPubMed
  8. ↵
    Berman DS, Germano G. Evaluation of ventricular ejection fraction, wall motion, wall thickening, and other parameters with gated myocardial perfusion single-photon emission computed tomography. J Nucl Cardiol. 1997;4:S169–S171.
    OpenUrlCrossRefPubMed
  9. ↵
    Tadamura E, Kudoh T, Motooka M, et al. Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging. J Am Coll Cardiol. 1999;33:991–997.
    OpenUrlCrossRefPubMed
  10. Cwajg E, Cwajg J, He ZX, et al. Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography. J Nucl Med. 1999;40:1857–1865.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    Bacher-Stier C, Muller S, Pachinger O, et al. Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography. Eur J Nucl Med. 1999;26:1533–1540.
    OpenUrlCrossRefPubMed
  12. ↵
    Faber TL, Akers MS, Peshock RM, Corbett JR. Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms. J Nucl Med. 1991;32:2311–2317.
    OpenUrlAbstract/FREE Full Text
  13. ↵
    Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995;36:2138–2147.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    Germano G, Erel J, Lewin H, Kavanagh PB, Berman DS. Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol. 1997;30:1360–1367.
    OpenUrlCrossRefPubMed
  15. ↵
    Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310.
    OpenUrlCrossRefPubMed
  16. ↵
    DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med. 1989;30:441–449.
    OpenUrlAbstract/FREE Full Text
  17. ↵
    Wackers FJT. Artifacts in planar and SPECT myocardial perfusion imaging. Am J Card Imaging. 1992;6:42–48.
    OpenUrlPubMed
  18. ↵
    Anagnostopoulos C, Gunning MG, Pennell DJ, Laney R, Proukakis H, Underwood SR. Regional myocardial motion and thickening assessed at rest by ECG-gated 99mTc-MIBI emission tomography and by magnetic resonance imaging. Eur J Nucl Med. 1996;23:909–916.
    OpenUrlCrossRefPubMed
  19. ↵
    Germano G, Kavanagh PB, Waechter P, et al. A new algorithm for the quantitation of myocardial perfusion SPECT. I. Technical principles and reproducibility. J Nucl Med. 2000;41:712–719.
    OpenUrlAbstract/FREE Full Text
  20. ↵
    Sharir T, Germano G, Waechter PB, et al. A new algorithm for the quantitation of myocardial perfusion SPECT. II. Validation and diagnostic yield. J Nucl Med. 2000;41:720–727.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    Blackman NJ-M, Koval JJ. Interval estimation for Cohen’s kappa as a measure of agreement. Stat Med. 2000;19:723–741.
    OpenUrlCrossRefPubMed
  22. ↵
    Lee DS, Cheon GJ, Ahn JY, Chung J-K, Lee MC. Reproducibility of assessment of myocardial function using gated Tc-99m-MIBI SPECT and quantitative software. Nucl Med Commun. 2000;21:1127–1134.
    OpenUrlCrossRefPubMed
  23. ↵
    Gunning MG, Anagnostopoulos C, Davies G, Forbat SM, Ell PJ, Underwood R. Gated techetium-99m-tetrofosmin SPECT and cine MRI to assess left ventricular contraction. J Nucl Med. 1997;38:438–442.
    OpenUrlAbstract/FREE Full Text
  24. ↵
    Prvulovich EM, Lonn AH, Bomanji JB, Jarritt PH, Ell PJ. Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease. Eur J Nucl Med. 1997;24:266–275.
    OpenUrlPubMed
  25. ↵
    Adachi IA, Morita K, Imran MB, et al. Heterogeneity of myocardial wall motion and thickening in the left ventricle evaluated with quantitative gated SPECT. J Nucl Cardiol 2000;7:296–300.
    OpenUrlCrossRefPubMed
  26. ↵
    Nichols K, DePuey EG, Krasnow N, Lefkowitz D, Rozanski A. Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardium: echocardiographic validation. J Nucl Cardiol. 1998;5:387–394.
    OpenUrlCrossRefPubMed
  27. ↵
    Cauvin JC, Boire JY, Maublant JC, Bonny JM, Zanca M, Veyre A. Automatic detection of the left ventricular myocardium long axis and center in thallium-201 single photon emission computed tomography. Eur J Nucl Med. 1992;19:1032–1037.
    OpenUrlPubMed
  28. ↵
    Germano G, Kavanagh PB, Su HT, et al. Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images. J Nucl Med. 1995;36:1107–1114.
    OpenUrlAbstract/FREE Full Text
  29. ↵
    Mizushige K, Furumoto W, Hirao K, Iwado Y, Ohmori K, Matsuo H. Quantitative evaluation of left ventricular regional wall motion using a real-time wall thickness curve system with two-dimensional echocardiography. Am J Cardiol. 1999;84:1204–1208.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 42, Issue 5
May 1, 2001
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated 99mTc-Sestamibi Myocardial SPECT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated 99mTc-Sestamibi Myocardial SPECT
Jin Chul Paeng, Dong Soo Lee, Gi Jeong Cheon, Myoung Mook Lee, June-Key Chung, Myung Chul Lee
Journal of Nuclear Medicine May 2001, 42 (5) 695-700;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated 99mTc-Sestamibi Myocardial SPECT
Jin Chul Paeng, Dong Soo Lee, Gi Jeong Cheon, Myoung Mook Lee, June-Key Chung, Myung Chul Lee
Journal of Nuclear Medicine May 2001, 42 (5) 695-700;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Gated Myocardial Perfusion SPECT: Basic Principles, Technical Aspects, and Clinical Applications
  • The Diagnostic and Prognostic Value of ECG-Gated SPECT Myocardial Perfusion Imaging
  • Gated SPECT Evaluation of the Relationship Between Admission Troponin I, Myocardial Salvage, and Functional Recovery in Acute Myocardial Infarction Treated by Abciximab and Early Primary Angioplasty
  • Myocardial Perfusion Imaging Using Gated SPECT in Heart Failure Patients Undergoing Cardiac Resynchronization Therapy
  • Prognostic Value of Rest 201Tl-Dipyridamole Stress 99mTc-Sestamibi Gated SPECT for Predicting Patient-Based Clinical Outcomes After Bypass Surgery in Patients with Ischemic Left Ventricular Dysfunction
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire