Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

68Ga-DOTATOC Versus 68Ga-DOTATATE PET/CT in Functional Imaging of Neuroendocrine Tumors

Thorsten D. Poeppel, Ina Binse, Stephan Petersenn, Harald Lahner, Matthias Schott, Gerald Antoch, Wolfgang Brandau, Andreas Bockisch and Christian Boy
Journal of Nuclear Medicine December 2011, 52 (12) 1864-1870; DOI: https://doi.org/10.2967/jnumed.111.091165
Thorsten D. Poeppel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ina Binse
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephan Petersenn
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Harald Lahner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthias Schott
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gerald Antoch
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wolfgang Brandau
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andreas Bockisch
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christian Boy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Radiolabeled somatostatin analogs represent valuable tools for both in vivo diagnosis and therapy of neuroendocrine tumors (NETs) because of the frequent tumoral overexpression of somatostatin receptors (sst). The 2 compounds most often used in functional imaging with PET are 68Ga-DOTATATE and 68Ga-DOTATOC. Both ligands share a quite similar sst binding profile. However, the in vitro affinity of 68Ga-DOTATATE in binding the sst subtype 2 (sst2) is approximately 10-fold higher than that of 68Ga-DOTATOC. This difference may affect their efficiency in the detection of NET lesions because it is the sst2 that is predominantly overexpressed in NET. We thus compared the diagnostic value of PET/CT with both radiolabeled somatostatin analogs (68Ga-DOTATATE and 68Ga-DOTATOC) in the same NET patients. Methods: Forty patients with metastatic NETs underwent 68Ga-DOTATOC and 68Ga-DOTATATE PET/CT as part of the work-up before prospective peptide receptor radionuclide therapy. The performance of both imaging methods was analyzed and compared for the detection of individual lesions per patient and for 8 defined body regions. A region was regarded positive if at least 1 lesion was detected in that region. In addition, radiopeptide uptake in terms of the maximal standardized uptake value (SUVmax) was compared for concordant lesions and renal parenchyma. Results: Seventy-eight regions were found positive with 68Ga-DOTATATE versus 79 regions with 68Ga-DOTATOC (not significant). Overall, however, significantly fewer lesions were detected with 68Ga-DOTATATE than with 68Ga-DOTATOC (254 vs. 262, P < 0.05). Mean 68Ga-DOTATATE SUVmax across all lesions was significantly lower than 68Ga-DOTATOC (16.0 ± 10.8 vs. 20.4 ± 14.7, P < 0.01). Mean SUVmax for renal parenchyma was not significantly different between 68Ga-DOTATATE and 68Ga-DOTATOC (12.7 ± 3.0 vs. 13.2 ± 3.3). Conclusion: 68Ga-DOTATOC and 68Ga-DOTATATE possess a comparable diagnostic accuracy for the detection of NET lesions, with 68Ga-DOTATOC having a potential advantage. The approximately 10-fold higher affinity for the sst2 of 68Ga-DOTATATE does not prove to be clinically relevant. Quite unexpectedly, SUVmax of 68Ga-DOTATOC scans tended to be higher than their 68Ga-DOTATATE counterparts.

  • 68Ga-DOTATOC PET/CT
  • 68Ga-DOTATATE PET/CT
  • NET

The abundant expression of somatostatin receptors (sst) is a characteristic of neuroendocrine tumors (NETs). To date, 5 receptor subtypes have been characterized (sst1–sst5) (1,2). NETs typically express several sst subtypes in a pattern related to tumor type, origin, and grade of differentiation (3,4). In most cases, sst2 is overexpressed (3,4). Structural differences between sst subtypes allow for receptor targeting with subtype-specific radiolabeled somatostatin analogs (5). Several analogs are used for peptide receptor radionuclide therapy (PRRT) and scintigraphic imaging or PET of NET. Quite recently, sst PET demonstrated its superiority over scintigraphy and CT (6,7).

The efficiency of a somatostatin analog depends on its specific binding profile. Particularly, the affinity to sst2 is paramount. Two compounds commonly used for sst PET and PRRT are DOTATOC and DOTATATE. Reubi et al. determined the binding profiles of several radiolabeled somatostatin analogs. There were significant differences in subtype-specific affinity after minor structural changes in the radioligand molecule, the introduction of a radiometal, or the use of different radiometals and chelators (2). Yet, the data regarding the analog with the highest uptake in NET shows discrepancies between in vitro and animal data on the one side (2,8,9) and human data on the other (10): Reubi et al. determined the affinity of 68Ga-DOTATATE in binding sst2 (0.2 ± 0.04 nM) to be approximately 10-fold higher than that of 68Ga-DOTATOC (2.5 ± 0.5 nM) (2). De Jong et al. compared 111In-diethylenetriaminepentaacetic acid (DTPA)-Tyr3-octreotide and 111In-DTPA-Tyr3-octreotate (and others) in rats bearing sst-expressing tumors: octreotate exhibited the highest uptake of all compounds tested (8). Storch et al. reported similar results of a comparison including 111In-DTPA-Tyr0-octreotide and 111In-DOTA-Tyr3-octreotate (also animal data) (9). However, Forrer et al. could not find relevant differences in tumor uptake of 111In-DOTATOC versus 111In-DOTATATE in a direct comparison in patients with metastasized NET (10).

The controversy extends into the therapeutic setting, because both compounds are used in PRRT. Because nephrotoxicity is a major concern in PRRT, the dose-limiting factor is often the radiation-absorbed dose to the kidneys (11). Hence, the tumor-to-kidney ratio of a radiopeptide is crucial. The dose is determined by the radiometal and the uptake and retention of the radiopeptide (11–13). Although Forrer et al. reported a higher tumor-to-kidney ratio for 90Y-DOTATOC than 90Y-DOTATATE (10), Esser et al. reported results in favor of 177Lu-DOTATATE versus 177Lu-DOTATOC (14).

Currently, there is no direct comparison of 68Ga-DOTATATE and 68Ga-DOTATOC available regarding tumor uptake and ability to detect NETs. Thus, it is unclear which radiopeptide is preferable for imaging of NET patients.

Therefore, the aim of this study was to compare both the tumor uptake of 68Ga-DOTATOC with that of 68Ga-DOTATATE and their diagnostic value in PET/CT in the same patients with metastasized NET.

MATERIALS AND METHODS

Patients

Forty patients (27 men, 13 women; mean age ± SD, 56 ± 19 y; age range, 27–81 y) were imaged as part of the work-up before prospective PRRT. Imaging is routinely performed with both 68Ga-DOTATOC and 68Ga-DOTATATE to determine optimal uptake for treatment with either 90Y-DOTATOC or 90Y-DOTATATE. All patients had histologically verified gastroenteropancreatic or bronchopulmonary NETs (plus 1 patient with malignant paraganglioma) and had prior imaging evidence of primary or residual or recurrent disease (primary tumor, metastases, or both). All aspects of patient care and treatment were performed at the discretion of the treating clinicians and according to routine procedures of the department, which are in accordance with the guidelines of the European Neuroendocrine Tumor Society (15). The imaging work-up was performed in accordance with guidelines issued by the university hospital institutional review board. Written informed consent was obtained from all patients. Patients who were treated with somatostatin analogs had received the long-acting formulation. The medication was discontinued before the imaging procedures: the average time of last application was 5 ± 1 wk (range, 3–7 wk; only 3 wk in 1 patient [patient 10], Supplemental Table 1 [supplemental materials are available online only at http://jnm.snmjournals.org], because of intense symptoms during withdrawal).

Radiopharmaceutical Preparation

68Ga peptides were synthesized in-house according to the method described by Zhernosekov et al. (16). 68Ga was obtained from a 68Ge/68Ga radionuclide generator (Eckert & Ziegler). Peptides were obtained from Bachem. Overall preparation time was about 60 min, with a radiochemical yield of 60%–70%. Quality control performed with 2 thin-layer chromatography systems revealed a radiochemical purity of greater than 98%.

68Ga-DOTATOC and 68Ga-DOTATATE Imaging

All patients underwent 68Ga-DOTATOC and 68Ga-DOTATATE imaging, with an average interval of less than 14 d. Five patients received the 68Ga-DOTATATE scan initially, and all others received the 68Ga-DOTATOC scan first.

Imaging was performed using 2 (ECAT) EXACT HR+ PET scanners: one stand-alone system (CTI/Siemens), the other the PET component of an integrated PET/CT scanner (Biograph Emotion Duo; Siemens). Both PET systems had been cross-calibrated. Imaging was performed as previously described (5,17,18). In short, attenuation-corrected whole-body (skull base to upper thighs) scans were acquired in 3-dimensional mode (4-min emission time per bed position, 3-min transmission time on the stand-alone PET, a Fourier-rebinning attenuation-weighted ordered-subset expectation maximization reconstruction algorithm, and smoothing with a 5-mm gaussian kernel). For PET/CT, the CT scan was obtained first using a limited breath-hold technique (CT acquisition parameters for the full- and low-dose protocols: 130 and 15 mAs, respectively; 130 and 110 kV, respectively; slice width, 5 mm; rotation time, 0.8 s; table speed, 8 mm per rotation). Iodinated contrast material was given intravenously using an automated injector. The small bowel was distended by administration of a water-equivalent oral contrast agent (18). To minimize radiation exposure and avoid the repeated use of contrast agents, each patient received only 1 full-dose contrast-enhanced CT scan. Thus, 36 patients received both examinations on the PET/CT scanner (first scan using the full-dose technique and the second scan using the low-dose technique for 32 patients; both scans using the low-dose technique in 4 patients), and 4 patients (with recent external whole-body contrast-enhanced CT) were evaluated on the stand-alone scanner.

Image Evaluation

Images were initially interpreted visually by 2 experienced nuclear medicine physicians unaware of the results of the other imaging examinations by counting the number of lesions with pathologically increased radiopeptide uptake in the following 8 regions: head and neck, mediastinum, lung, liver, pancreas, abdomen and pelvis (excluding liver and pancreas), bone, and lymph nodes (whole body, i.e., composite of several regions). Only lesions with a morphologic correlate on the CT portion of the full-dose PET/CT scan or on follow-up examinations were considered. Thus, only 31 of the patients with a full-dose PET/CT scan were analyzed in this manner. If more than 5 lesions were visualized within 1 region, the number of lesions was truncated at 5 for that region to avoid bias (19,20). In a second semiquantitative approach, maximal standardized uptake values (SUVmax) were determined in all patients on a lesion-by-lesion basis by 1 of the initial readers. SUV measurements were performed side-by-side on corresponding lesions on fused image datasets. Spheric volumes of interest were drawn closely encircling a lesion, and the SUVmax was obtained. If more than 5 lesions were visualized within 1 organ, only the first 5 lesions in the craniocaudal direction were considered, with the exception of the liver, in which the lesions were traced in the caudocranial direction to avoid attenuation artifacts. Spheric reference volumes of interest were drawn in unaffected liver tissue, the erector spinae muscles, and the gluteal muscles on the left or right side (as appropriate). The native SUVmax of the lesions was normalized to the SUVmax of the liver reference region and to the average SUVmax of the muscle reference regions. A further spheric volume of interest was placed in the renal cortex, avoiding the pelvis and calyces in the left or right kidney (as appropriate).

Statistical Analysis

Analysis was performed at 3 levels. The first level addressed the aforementioned 8 regions. A region was regarded positive if at least 1 lesion was detected there. The second level analyzed the individual count of lesions per region. At the third level, the SUVmax of corresponding lesions (overall and in the following 5 subgroups: hepatic metastases, lymphatic metastases, bone metastases, pulmonary metastases, and primary tumor) was compared.

On all levels, results from both groups were also compared with respect to grading (low, intermediate, or high grade) and tumor origin (foregut, midgut, pancreas, or cancer of unknown primary [CUP]). Although pancreatic NETs are foregut in origin, they are regarded here as a separate subgroup because of their somewhat distinct biologic behavior (such as response to therapeutic interventions) and a sufficient sample size.

Nonparametric methods were used. Positive regions were compared using the McNemar test. The number of lesions per region and the SUVmax of corresponding lesions were compared using the Wilcoxon signed-rank test. Scanning parameters were tested for possible differences with the Mann–Whitney U test. Potential correlations were tested with Kruskal–Wallis ANOVA or Spearman rank correlation coefficient, as appropriate.

The significance level was 0.05, 2-sided. A Bonferroni adjustment was applied as appropriate. Analyses were performed with STATISTICA (version 8; StatSoft, Inc.).

Moreover, agreement between SUV measurements of both imaging procedures was analyzed on the basis of a Bland–Altman plot (21) of mean differences (Prism 5c; GraphPad Software, Inc.).

RESULTS

Scan parameters and patient characteristics are presented in Supplemental Table 1 and Table 1, respectively. There was no significant difference between both imaging procedures regarding the scanning parameters (uptake time, injected activity, specific activity, and injected peptide mass).

View this table:
  • View inline
  • View popup
TABLE 1

Scan Parameters

Regional and Lesional Analyses

Seventy-eight regions (excluding the composite region “lymph nodes”) were found positive with 68Ga-DOTATATE versus 79 regions with 68Ga-DOTATOC (Supplemental Table 2). The only discrepant region was head and neck, with 1 positive lymph node in a patient. On average, 3 positive regions were found per patient with each of the imaging procedures. There was no significant difference between either imaging procedure regarding the number of detected regions per patient or the number of patients with at least 1 lesion within 1 of the 8 regions (including the composite region “lymph nodes”) (Supplemental Table 3).

Within the defined regions (excluding the composite region “lymph nodes”), 254 lesions were detected with 68Ga-DOTATATE versus 262 lesions with 68Ga-DOTATOC (Supplemental Table 4). The difference was significant (P = 0.012). The 8 lesions that were detected additionally with 68Ga-DOTATOC were found in 8 patients and were distributed among the following regions: head and neck, lung, liver (3 patients), pancreas, abdomen and pelvis, and bone. On average, 8.2 lesions were found per patient with 68Ga-DOTATATE versus 8.5 lesions with 68Ga-DOTATOC. There was no significant difference between either imaging procedure in lesion detection with respect to tumor grading or tumor origin (foregut, midgut, pancreas, or CUP).

SUV Analyses

Mean 68Ga-DOTATATE SUVmax across all lesions was 16.0 ± 10.8 versus 20.4 ± 14.7 with 68Ga-DOTATOC (Table 2). The difference was significant (P = 0.0005). The difference retained its significance for the normalized values (SUVmax normalized to liver, P = 0.012; SUVmax normalized to muscle, P = 0.001). The difference retained its significance across the subgroups (hepatic metastases [34 patients], P = 0.007; lymphatic metastases [24 patients], P = 0.002; bone metastases [17 patients], P = 0.008). No significance test was applied to the subgroups primary tumor (11 patients) and pulmonary metastases (5 patients) because of the small sample size.

View this table:
  • View inline
  • View popup
TABLE 2

Tumor Uptake

The mean difference between 68Ga-DOTATATE and 68Ga-DOTATOC SUVmax across all lesions was 4.5 ± 9.8 (range, 0.1–55.3). There was no significant relationship between the differences of SUVmax measurements between 68Ga-DOTATATE and 68Ga-DOTATOC and tumor grading or tumor origin (foregut, midgut, pancreas, or CUP).

Even though 33 of 40 patients exhibited on average higher 68Ga-DOTATOC SUVmax than 68Ga-DOTATATE SUVmax, the tumor uptake varied considerably both within and between patients: 18 patients displayed only lesions with higher uptake of 68Ga-DOTATOC than 68Ga-DOTATATE (Fig. 1), 18 patients displayed a mixture of lesions with either higher uptake of 68Ga-DOTATATE or (predominantly) of 68Ga-DOTATOC, and 4 patients displayed only lesions with higher uptake of 68Ga-DOTATATE than 68Ga-DOTATOC (Fig. 2).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Example of lesions with exclusively higher uptake of 68Ga-DOTATOC than 68Ga-DOTATATE (patient 24). (A, from left to right) 68Ga-DOTATOC PET maximum-intensity projection, 68Ga-DOTATOC PET, CT, and PET/CT fusion. (B, from left to right) 68Ga-DOTATATE PET maximum-intensity projection, 68Ga-DOTATATE PET, and PET/CT fusion. Arrow refers to ileal carcinoid (SUVmax 68Ga-DOTATOC, 21.0; SUVmax 68Ga-DOTATATE, 8.2).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Example of lesions with exclusively higher uptake of 68Ga-DOTATATE than 68Ga-DOTATOC (patient 27). (A, from left to right) 68Ga-DOTATOC PET maximum-intensity projection, 68Ga-DOTATOC PET, CT, and PET/CT fusion. (B, from left to right) 68Ga-DOTATATE PET maximum-intensity projection, 68Ga-DOTATATE PET, and PET/CT fusion. Arrow refers to hepatic metastasis (SUVmax 68Ga-DOTATOC, 16.7; SUVmax 68Ga-DOTATATE, 21.2).

There was no significant difference between measurements of SUVmax in patients with or without prior somatostatin analog therapy.

Mean 68Ga-DOTATATE SUVmax for renal parenchyma was 12.7 ± 3.0 versus 13.2 ± 3.3 with 68Ga-DOTATOC (Table 2). The difference was not significant for either the native or the normalized values. The tumor-to-kidney ratio was 1.3 ± 0.8 for 68Ga-DOTATATE and 1.6 ± 1.1 for 68Ga-DOTATOC. The difference was significant (P = 0.007). The correlation coefficient of mean SUVmax 68Ga-DOTATATE and 68Ga-DOTATOC for renal parenchyma was 0.50 (correlation coefficient SUVmax normalized to liver, 0.59; correlation coefficient SUVmax normalized to muscle, 0.47).

The Bland–Altman plot showed a fair agreement between both measures of sst expression, with a bias toward lower SUVmax measurements in 68Ga-DOTATATE imaging (Supplemental Fig. 1).

DISCUSSION

This study demonstrates the high capability of both radiolabeled somatostatin analogs—68Ga-DOTATATE and 68Ga-DOTATOC—to detect lesions from NETs. However, 68Ga-DOTATOC might be superior to 68Ga-DOTATATE, presumably because of higher tumor uptake, as indicated by SUVmax. Nonetheless, there was considerable variance in preferential tumor uptake of the 2 compounds.

Lesion Detection

In our direct comparative study, 68Ga-DOTATOC was marginally superior to 68Ga-DOTATATE in detecting NET lesions. The advantage was on the whole and not limited to higher detection rates within one of the evaluated distinct body regions (head and neck, mediastinum, lung, liver, pancreas, abdomen and pelvis, bone, and lymph nodes) or a distinct type of metastatic spread (lymphatic, hepatic, osseous, or pulmonary). Three published studies compared both analogs (coupled to different radiometals) in patients (10,14,22), although mainly for dosimetric purposes. Only Forrer et al. provide some details about lesion detection (10). They investigated the biodistribution and dosimetry of 111In-DOTATOC and 111In-DOTATATE in a small set of patients: the results obtained with both compounds were comparable; however, 111In-DOTATOC enabled better visualization of some liver metastases (10).

Tumor differentiation influences the detection of NET lesions with radiolabeled somatostatin analogs because of a varying capability of expressing sst (23). Moreover, the origin of a NET influences its profile of expression of sst subtypes (24). We examined whether these parameters possessed differential influence on the rate of lesion detection with both tracers. However, we found no significant difference between either imaging procedure in lesion detection with respect to grading (low, intermediate, or high grade) or tumor origin (foregut, midgut, pancreas, or CUP).

Tumor Uptake

SUVmax of concordant lesions obtained with 68Ga-DOTATOC was significantly higher than that obtained with 68Ga-DOTATATE. Normalization either to a tissue with moderate to high sst expression (liver) or to a tissue with low sst expression (muscle) was not able to reduce interpeptide variability and did not cause relevant changes of the results. According to Reubi et al., bronchopulmonary and gastroenteropancreatic NETs are mainly characterized by overexpression of sst1 and sst2 (3,4). Neither 68Ga-DOTATOC nor 68Ga-DOTATATE shows relevant binding to sst1 (2). Hence, the higher SUVmax of 68Ga-DOTATOC is surprising given that 68Ga-DOTATATE possesses an approximately 10-fold higher in vitro affinity in binding sst2 (0.2 ± 0.04 nM vs. 2.5 ± 0.5 nM (2)). However, some NETs exhibit overexpression of sst5 (4,25). 68Ga-DOTATOC possesses a somewhat increased affinity for this receptor subtype in comparison to 68Ga-DOTATATE (73 ± 21 nM vs. 377 ± 18 nM) (2). This difference in affinity profiles might explain the differential tumor uptake. However, this explanation remains hypothetic because no receptor staining of the NET lesions in question was performed.

Our results are in contrast to animal data: De Jong et al. compared 111In-DTPA-octreotide and 111In-DTPA-octreotate (and others) both in vitro and in vivo in the same rats bearing somatostatin receptor–expressing pancreatic tumors: 111In-octreotate possessed the highest uptake in tumors from all compounds tested (8). Storch et al. reported similar results comparing 111In-DTPA-octreotide and 111In-DOTA-octreotate (and others) both in vitro and in vivo in rats (9). As mentioned, there are 3 studies comparing biodistribution and dosimetry of both analogs in patients (10,14,22). Forrer et al. found no significant difference in mean residence times and estimated mean absorbed tumor doses for 90Y-DOTATOC and 90Y-DOTATATE, although mean doses derived from 111In-DOTATOC were slightly higher (10). In contrast to these results, Esser et al. reported that 177Lu-DOTATATE possessed a higher affinity than 177Lu-DOTATOC in the therapeutic setting. However, data are provided only for residence times (which were longer for 177Lu-DOTATATE than 177Lu-DOTATOC). Kwekkeboom et al. also reported higher tumor uptake of 177Lu-DOTA-octreotate than of 111In-DTPA-octreotide (22). Yet, they used both a different chelator and a different radiometal in their comparison, which exerts significant influence on receptor binding (2).

The mean difference of all lesional SUVmax measurements between 68Ga-DOTATATE and 68Ga-DOTATOC tended to be small; however, there was considerable variance both within and between patients. Nearly half of all patients displayed a mixture of lesions with either higher uptake of 68Ga-DOTATATE or (predominantly) of 68Ga-DOTATOC, most of the remaining patients displayed solely lesions with higher uptake of 68Ga-DOTATOC, and the minority of patients displayed only lesions with higher uptake of 68Ga-DOTATATE. Our findings are in line with those of Forrer et al., who found sst expression to vary considerably between patients and tumor manifestations (10). These variations imply the wide spectrum of cellular differentiation and receptor expression of NETs. However, there was no significant relationship between the differences of SUVmax measurements between 68Ga-DOTATATE and 68Ga-DOTATOC regarding tumor grading (low, intermediate, or high grade) or tumor origin (foregut, midgut, pancreas, or CUP).

In the case of receptor-active substances, the SUVmax represents a composite measure of specific receptor binding and internalization, unspecific binding, effects of tissue perfusion, and others (26,27). The intrapatient comparison approach in this study controls for most confounding factors, rendering differences in SUVmax to be most likely caused by differences in binding and internalization properties of the respective somatostatin analog. However, possible differences in attenuation correction between (predominantly) low-dose PET/CT in 68Ga-DOTATATE scans and contrast-enhanced PET/CT in 68Ga-DOTATOC scans may have influenced the results. Yet, those effects seem to be negligible (17,28). In particular, relevant artificial differences are unlikely because the SUVmax of the combination of PET-only scans and low-dose PET/CT for 68Ga-DOTATOC is still significantly higher than that for its 68Ga-DOTATATE counterpart (P = 0.017). Also, a bias due to slightly longer uptake time of 68Ga-DOTATOC than 68Ga-DOTATATE scans cannot be excluded. However, there was no significant difference between the SUVmax of 68Ga-DOTATATE scans with shorter uptake time and that of scans with longer uptake time than the corresponding 68Ga-DOTATOC scans. Furthermore, somatostatin analog therapy may affect tumor uptake because of interacting factors such as partial saturation of sst-expressing nontarget tissues and competition of labeled and unlabeled somatostatin analog for the receptor on tumor tissue. On that account, the medication was discontinued before the imaging procedures. Consequently, no significant differences between measurements of SUVmax in patients with or without prior somatostatin analog therapy were found. Because most patients received the 68Ga-DOTATOC scan as the initial imaging procedure, potential sequence effects cannot be ruled out. These effects may include changes in tumor size or composition between the scans that might have caused a different somatostatin receptor density. However, the mean interscan interval (9 d) was small, compared with typical tumor growth. Relevant changes between the scans thus seem not likely.

Renal Uptake

There was no significant difference between renal uptake of either radiopeptide. However, the tumor-to-kidney ratio found in this study was significantly in favor of 68Ga-DOTATOC. This finding is in contrast to animal data on 111In-DTPA-OC and 111In-DTPA-TATE (9) but is in line with human data derived from a comparison of 111In-DOTATOC and 111In-DOTATATE (10). Because nephrotoxicity is a major concern in PRRT (12,13), one might thus speculate about the peptide of preference for therapy to produce optimal tumor doses while avoiding renal impairment (11). However, caution must be taken translating this diagnostic investigation to a therapeutic setting because significantly higher peptide concentrations are used in the latter case. The interplay of unspecific peptide binding, partial saturation of sst-expressing nontarget tissues, and competition of labeled and unlabeled peptide for the receptor on tumor tissue affects overall uptake in the tumor (29,30). Hence, the uptake of radiolabeled somatostatin analogs in sst-expressing tumors is dependent on the amount of injected peptide mass (29). Moreover, not only peptide uptake but also residence times are factors determining the target dose. Esser et al. (14) found the residence times of 177Lu-DOTATATE to be longer than those of 177Lu-DOTATOC both in tumors and in kidneys. However, division of the mean tumor residence time ratio by the mean kidney residence time ratio yielded a factor of 1.5 in favor of 177Lu-DOTATATE. It is thus even more complicated to decide which peptide is to be preferred for radiotherapy. Moreover, tumor uptake shows high inter- and intraindividual variance, with unpredictable preferential of 1 radiopeptide. Only measurements with both radiopeptides reliably permit the choice of the optimal radiopeptide for therapy. Thus, individual dosimetry seems advisable to decide whether a patient can be admitted for therapy with radiolabeled DOTATOC or DOTATATE and to choose the therapeutic modality for each patient.

CONCLUSION

68Ga-DOTATOC and 68Ga-DOTATATE possess a comparable diagnostic value in the detection of lesions of NETs, with a potential advantage for 68Ga-DOTATOC. The approximately 10-fold higher affinity in binding sst2 of 68Ga-DOTATATE did not prove to be clinically relevant. Quite unexpectedly, SUVmax measurements with 68Ga-DOTATOC tended to be higher than their 68Ga-DOTATATE counterparts.

Nevertheless, there is significant inter- and interindividual variance regarding the radiopeptide with maximal lesional uptake. Thus, our data encourage the application of different sst ligands to permit efficient imaging and therapy of NETs by optimal targeting of tumor receptors.

Footnotes

  • Published online Nov. 9, 2011.

  • © 2011 by Society of Nuclear Medicine

REFERENCES

  1. 1.↵
    1. Hoyer D,
    2. Bell GI,
    3. Berelowitz M,
    4. et al
    . Classification and nomenclature of somatostatin receptors. Trends Pharmacol Sci. 1995;16:86–88.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Reubi JC,
    2. Schar JC,
    3. Waser B,
    4. et al
    . Affinity profiles for human somatostatin receptor subtypes SST1-SST5 of somatostatin radiotracers selected for scintigraphic and radiotherapeutic use. Eur J Nucl Med. 2000;27:273–282.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Reubi JC,
    2. Waser B
    . Concomitant expression of several peptide receptors in neuroendocrine tumours: molecular basis for in vivo multireceptor tumour targeting. Eur J Nucl Med Mol Imaging. 2003;30:781–793.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Reubi JC,
    2. Waser B,
    3. Schaer JC,
    4. Laissue JA
    . Somatostatin receptor sst1-sst5 expression in normal and neoplastic human tissues using receptor autoradiography with subtype-selective ligands. Eur J Nucl Med. 2001;28:836–846.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Boy C,
    2. Heusner TA,
    3. Poeppel TD,
    4. et al
    . 68Ga-DOTATOC PET/CT and somatostatin receptor (sst1-sst5) expression in normal human tissue: correlation of sst2 mRNA and SUV(max). Eur J Nucl Med Mol Imaging. 2011;38:3–4.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Buchmann I,
    2. Henze M,
    3. Engelbrecht S,
    4. et al
    . Comparison of 68Ga-DOTATOC PET and 111In-DTPAOC (Octreoscan) SPECT in patients with neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2007;34:1617–1626.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Gabriel M,
    2. Decristoforo C,
    3. Kendler D,
    4. et al
    . 68Ga-DOTA-Tyr3-octreotide PET in neuroendocrine tumors: comparison with somatostatin receptor scintigraphy and CT. J Nucl Med. 2007;48:508–518.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. de Jong M,
    2. Breeman WA,
    3. Bakker WH,
    4. et al
    . Comparison of 111In-labeled somatostatin analogues for tumor scintigraphy and radionuclide therapy. Cancer Res. 1998;58:437–441.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Storch D,
    2. Behe M,
    3. Walter MA,
    4. et al
    . Evaluation of [99mTc/EDDA/HYNIC0]octreotide derivatives compared with [111In-DOTA0,Tyr3, Thr8]octreotide and [111In-DTPA0]octreotide: does tumor or pancreas uptake correlate with the rate of internalization? J Nucl Med. 2005;46:1561–1569.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Forrer F,
    2. Uusijarvi H,
    3. Waldherr C,
    4. et al
    . A comparison of 111In-DOTATOC and 111In-DOTATATE: biodistribution and dosimetry in the same patients with metastatic neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2004;31:1257–1262.
    OpenUrlPubMed
  11. 11.↵
    1. Rolleman EJ,
    2. Melis M,
    3. Valkema R,
    4. Boerman OC,
    5. Krenning EP,
    6. de Jong M
    . Kidney protection during peptide receptor radionuclide therapy with somatostatin analogues. Eur J Nucl Med Mol Imaging. 2010;37:1018–1031.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Bodei L,
    2. Cremonesi M,
    3. Ferrari M,
    4. et al
    . Long-term evaluation of renal toxicity after peptide receptor radionuclide therapy with 90Y-DOTATOC and 177Lu-DOTATATE: the role of associated risk factors. Eur J Nucl Med Mol Imaging. 2008;35:1847–1856.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Valkema R,
    2. Pauwels SA,
    3. Kvols LK,
    4. et al
    . Long-term follow-up of renal function after peptide receptor radiation therapy with 90Y-DOTA(0),Tyr(3)-octreotide and 177Lu-DOTA(0), Tyr(3)-octreotate. J Nucl Med. 2005;46(suppl 1):83S–91S.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Esser JP,
    2. Krenning EP,
    3. Teunissen JJ,
    4. et al
    . Comparison of [177Lu-DOTA(0),Tyr(3)]octreotate and [177Lu-DOTA(0),Tyr(3)]octreotide: which peptide is preferable for PRRT? Eur J Nucl Med Mol Imaging. 2006;33:1346–1351.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Plöckinger U,
    2. Rindi G,
    3. Arnold R,
    4. et al
    . Guidelines for the diagnosis and treatment of neuroendocrine gastrointestinal tumours: a consensus statement on behalf of the European Neuroendocrine Tumour Society (ENETS). Neuroendocrinology. 2004;80:394–424.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Zhernosekov KP,
    2. Filosofov DV,
    3. Baum RP,
    4. et al
    . Processing of generator-produced 68Ga for medical application. J Nucl Med. 2007;48:1741–1748.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Antoch G,
    2. Freudenberg LS,
    3. Stattaus J,
    4. et al
    . Whole-body positron emission tomography-CT: optimized CT using oral and IV contrast materials. AJR. 2002;179:1555–1560.
    OpenUrlPubMed
  18. 18.↵
    1. Antoch G,
    2. Kuehl H,
    3. Kanja J,
    4. et al
    . Dual-modality PET/CT scanning with negative oral contrast agent to avoid artifacts: introduction and evaluation. Radiology. 2004;230:879–885.
    OpenUrlPubMed
  19. 19.↵
    1. Binderup T,
    2. Knigge U,
    3. Loft A,
    4. et al
    . Functional imaging of neuroendocrine tumors: a head-to-head comparison of somatostatin receptor scintigraphy, 123I-MIBG scintigraphy, and 18F-FDG PET. J Nucl Med. 2010;51:704–712.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Therasse P,
    2. Arbuck SG,
    3. Eisenhauer EA,
    4. et al
    . New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J Natl Cancer Inst. 2000;92:205–216.
    OpenUrlAbstract/FREE Full Text
  21. 21.↵
    1. Bland JM,
    2. Altman DG
    . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Kwekkeboom DJ,
    2. Bakker WH,
    3. Kooij PP,
    4. et al
    . [177Lu-DOTAOTyr3]octreotate: comparison with [111In-DTPAo]octreotide in patients. Eur J Nucl Med. 2001;28:1319–1325.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Kayani I,
    2. Bomanji JB,
    3. Groves A,
    4. et al
    . Functional imaging of neuroendocrine tumors with combined PET/CT using 68Ga-DOTATATE (DOTA-DPhe1,Tyr3-octreotate) and 18F-FDG. Cancer. 2008;112:2447–2455.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. Koopmans KP,
    2. Neels ON,
    3. Kema IP,
    4. et al
    . Molecular imaging in neuroendocrine tumors: molecular uptake mechanisms and clinical results. Crit Rev Oncol Hematol. 2009;71:199–213.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Wild D,
    2. Macke HR,
    3. Waser B,
    4. et al
    . 68Ga-DOTANOC: a first compound for PET imaging with high affinity for somatostatin receptor subtypes 2 and 5. Eur J Nucl Med Mol Imaging. 2005;32:724.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Koukouraki S,
    2. Strauss LG,
    3. Georgoulias V,
    4. et al
    . Evaluation of the pharmacokinetics of 68Ga-DOTATOC in patients with metastatic neuroendocrine tumours scheduled for 90Y-DOTATOC therapy. Eur J Nucl Med Mol Imaging. 2006;33:460–466.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Rodrigues M,
    2. Traub-Weidinger T,
    3. Li S,
    4. Ibi B,
    5. Virgolini I
    . Comparison of 111In-DOTA-DPhe1-Tyr3-octreotide and 111In-DOTA-lanreotide scintigraphy and dosimetry in patients with neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2006;33:532–540.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Yau YY,
    2. Chan WS,
    3. Tam YM,
    4. et al
    . Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error? J Nucl Med. 2005;46:283–291.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. de Jong M,
    2. Breeman WA,
    3. Bernard BF,
    4. et al
    . Tumour uptake of the radiolabelled somatostatin analogue [DOTA0, TYR3]octreotide is dependent on the peptide amount. Eur J Nucl Med. 1999;26:693–698.
    OpenUrlCrossRefPubMed
  30. 30.↵
    1. Velikyan I,
    2. Sundin A,
    3. Eriksson B,
    4. et al
    . In vivo binding of [68Ga]-DOTATOC to somatostatin receptors in neuroendocrine tumours–impact of peptide mass. Nucl Med Biol. 2010;37:265–275.
    OpenUrlCrossRefPubMed
  • Received for publication April 1, 2011.
  • Accepted for publication August 22, 2011.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 52 (12)
Journal of Nuclear Medicine
Vol. 52, Issue 12
December 1, 2011
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
68Ga-DOTATOC Versus 68Ga-DOTATATE PET/CT in Functional Imaging of Neuroendocrine Tumors
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
68Ga-DOTATOC Versus 68Ga-DOTATATE PET/CT in Functional Imaging of Neuroendocrine Tumors
Thorsten D. Poeppel, Ina Binse, Stephan Petersenn, Harald Lahner, Matthias Schott, Gerald Antoch, Wolfgang Brandau, Andreas Bockisch, Christian Boy
Journal of Nuclear Medicine Dec 2011, 52 (12) 1864-1870; DOI: 10.2967/jnumed.111.091165

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
68Ga-DOTATOC Versus 68Ga-DOTATATE PET/CT in Functional Imaging of Neuroendocrine Tumors
Thorsten D. Poeppel, Ina Binse, Stephan Petersenn, Harald Lahner, Matthias Schott, Gerald Antoch, Wolfgang Brandau, Andreas Bockisch, Christian Boy
Journal of Nuclear Medicine Dec 2011, 52 (12) 1864-1870; DOI: 10.2967/jnumed.111.091165
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • PET- and CT-Based Imaging Criteria for Response Assessment of Gastroenteropancreatic Neuroendocrine Tumors Under Radiopharmaceutical Therapy
  • Side-by-Side Comparison of the In Vivo Performance of [212Pb]Pb-DOTAMTATE and Other SSTR2-Targeting Compounds
  • Somatostatin Receptor Imaging with [18F]FET-{beta}AG-TOCA PET/CT and [68Ga]Ga-DOTA-Peptide PET/CT in Patients with Neuroendocrine Tumors: A Prospective, Phase 2 Comparative Study
  • Evaluation of [68Ga]-DOTATOC PET/MRI in Patients with Meningioma of the Subcranial and Intraorbital Space
  • 18F-AlF-NOTA-Octreotide Outperforms 68Ga-DOTATATE/NOC PET in Neuroendocrine Tumor Patients: Results from a Prospective, Multicenter Study
  • 18F-DOPA PET/CT at the Forefront of Initial or Presurgical Evaluation of Small-Intestine Neuroendocrine Tumors
  • Prognostic Value of Whole-Body PET Volumetric Parameters Extracted from 68Ga-DOTATOC PET/CT in Well-Differentiated Neuroendocrine Tumors
  • Somatostatin Receptor Imaging and Theranostics: Current Practice and Future Prospects
  • Preventive medicine of von Hippel-Lindau disease-associated pancreatic neuroendocrine tumors
  • Safety, Biodistribution, and Radiation Dosimetry of 68Ga-OPS202 in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase I Imaging Study
  • Sensitivity Comparison of 68Ga-OPS202 and 68Ga-DOTATOC PET/CT in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase II Imaging Study
  • Appropriate Use Criteria for Somatostatin Receptor PET Imaging in Neuroendocrine Tumors
  • Current Concepts in 68Ga-DOTATATE Imaging of Neuroendocrine Neoplasms: Interpretation, Biodistribution, Dosimetry, and Molecular Strategies
  • 68Ga-DOTATOC Imaging of Neuroendocrine Tumors: A Systematic Review and Metaanalysis
  • Iodine Symporter Targeting with 124I/131I Theranostics
  • Head-to-Head Comparison of 64Cu-DOTATATE and 68Ga-DOTATOC PET/CT: A Prospective Study of 59 Patients with Neuroendocrine Tumors
  • Molecular Imaging of Gastroenteropancreatic Neuroendocrine Tumors: Current Status and Future Directions
  • 68Ga-DOTATOC PET/CT in Patients with Iodine- and 18F-FDG-Negative Differentiated Thyroid Carcinoma and Elevated Serum Thyroglobulin
  • 68Ga-DOTATATE Compared with 111In-DTPA-Octreotide and Conventional Imaging for Pulmonary and Gastroenteropancreatic Neuroendocrine Tumors: A Systematic Review and Meta-Analysis
  • Prognostic Value of 68Ga-DOTANOC PET/CT SUVmax in Patients with Neuroendocrine Tumors of the Pancreas
  • Preclinical Evaluation of a High-Affinity 18F-Trifluoroborate Octreotate Derivative for Somatostatin Receptor Imaging
  • Quantitative and Qualitative Intrapatient Comparison of 68Ga-DOTATOC and 68Ga-DOTATATE: Net Uptake Rate for Accurate Quantification
  • Free Somatostatin Receptor Fraction Predicts the Antiproliferative Effect of Octreotide in a Neuroendocrine Tumor Model: Implications for Dose Optimization
  • Comparative Biodistribution and Radiation Dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in Patients with Neuroendocrine Tumors
  • Comparison of 68Ga-DOTANOC and 68Ga-DOTATATE PET/CT Within Patients with Gastroenteropancreatic Neuroendocrine Tumors
  • The Role of 68Ga-DOTATATE PET/CT in Suspected Neuroendocrine Tumors
  • Clinical PET of Neuroendocrine Tumors Using 64Cu-DOTATATE: First-in-Humans Study
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles