Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

How many time points for personalized dosimetry? Use of automated batch processing software for analysis of large patient population.

Alexandre Chicheportiche, Adam Kesner and Nanette Freedman
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1743;
Alexandre Chicheportiche
1Hadassah Hospital Jerusalem Israel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adam Kesner
3Memorial Sloan Kettering Cancer Center New York NY United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nanette Freedman
2Ichilov Hospital Tel Aviv Israel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1743

Objectives: Personalized dosimetry offers the potential of reducing risk of high dose to vulnerable normal organs while maximizing tumor dose in radionuclide therapy, but involves additional efforts in scan acquisition and data analysis. In this retrospective study of post-treatment scans of patients with neuroendocrine tumors receiving Lu-177 DOTATATE Peptide Receptor RadioTherapy (PRRT), we compared the impact of removing one of the three recommended biodistribution SPECT scans required for modelling source organ biodistribution. Dosimetry estimations were compared between full 3 scan and abbreviated 2 scan methods in a population of clinical scans/administration cycles using in-house developed automated batch processing software, Dosimetry Data Processor (DDP), for rapid efficient data analysis.

Methods: Patients receiving PRRT underwent 3 post-treatment scans during the week following treatment to verify tumor uptake and provide data for personalized dosimetry. Vendor software, Dosimetry ToolKit (DTK) from GE, was used to define VOI’s on the post-treatment scans, calculate corresponding time activity curves for patient organs, and save this data in a file. DDP software was run to read in these files and perform curve fitting, numerical integration, error checking, and absorbed dose calculation (using OLINDA/EXM Dose Conversion Factors). Standard processing of files from 634 treatments (197 patients) used mono-exponential curve fitting of the three original data points and integration to estimate organ and body remainder time integrated activity - (residence time), which were then processed to derive absorbed dose estimations. We then modified our DDP software to omit the first time point of scan data, and to recalculate dosimetry for the population using only the two other measurement time points. The population dose estimates based on two vs three time points were compared.

Results: The time required for reprocessing data with 2 time points for the 634 treatments was about 6 minutes and 30 sec, i.e., about 0.6 sec per treatment using a PC on Windows 10 with an Intel Core i5 CPU @ 2.30 Ghz. Kidney dose per treatment cycle estimated from 3 and from 2 time points respectively were 0.709 ± 0.306 mGy/MBq (mean ± SD) and 0.710 ± 0.307 mGy/MBq with a mean absolute % difference <2%. However, it is noteworthy that in few cases (about 10 cycles) the magnitude of the relative difference exceeds 10%. The reasons for such differences and the influence on the number of projected permissible treatment cycles for the 197 patients were varied and case specific. For liver, spleen and tumors mean absolute % differences between the two calculations of 2.56%, 3.00% and 10.25%, respectively, were obtained.

Conclusions: Interest in and acceptance of radionuclide therapy continues to grow. New mandates in regulations are compelling new levels of responsibility from treatment providers. Provision of quality dosimetry must be balanced with practical considerations imposed by the assessment. Whether a reduction of acquisition time points is built into protocols, or imposed by uncontrollable circumstances, we must understand our capacity to utilize the remaining available information. Our results show similar dose estimates whether using the 2 time points or 3 time points calculation with low mean absolute % differences (&#8804;3% for organs). However, caution is required since in few cases the relative difference in kidney dose can reach few tens of percent. In the future we will use our data and tools to perform more analysis on the impact of measurement timing on dose estimation. RESEARCH SUPPORT: We would like to acknowledge GE Healthcare for their partial support of this project.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
How many time points for personalized dosimetry? Use of automated batch processing software for analysis of large patient population.
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
How many time points for personalized dosimetry? Use of automated batch processing software for analysis of large patient population.
Alexandre Chicheportiche, Adam Kesner, Nanette Freedman
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1743;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
How many time points for personalized dosimetry? Use of automated batch processing software for analysis of large patient population.
Alexandre Chicheportiche, Adam Kesner, Nanette Freedman
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1743;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • Comparison of 22 partial volume correction methods for amyloid PET imaging with 11C-PiB
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
Show more Instrumentation & Data Analysis Track

Data Analysis & Management Posters

  • Evaluation of Quantitative Whole Body Dynamic FDG-PET Using Block Sequence Regularized Expectation Maximization (BSREM) Reconstruction
  • Feasibility of 18F-THK5351 PET quantitation using the Centiloid scale
  • NaF-PET/CT for assessment of temporomandibular joint osseous activity in rheumatoid arthritis patients and healthy subjects
Show more Data Analysis & Management Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire