Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT

Junyoung Park, Sungwoo Bae, Seongho Seo, Ji In Bang, Won-Woo Lee and Jae Sung Lee
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 26;
Junyoung Park
2Department of Biomedical Sciences Seoul National University Seoul Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sungwoo Bae
5Department of Nuclear Medicine Seoul National University Bundang Hospital Seoul Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Seongho Seo
1Gachon University Incheon Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ji In Bang
5Department of Nuclear Medicine Seoul National University Bundang Hospital Seoul Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Won-Woo Lee
4Institute of Radiation Medicine, Medical Research Seoul National University Seoul Korea, Republic of
5Department of Nuclear Medicine Seoul National University Bundang Hospital Seoul Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jae Sung Lee
3Department of Nuclear Medicine Seoul National University Seoul Korea, Republic of
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

26

Objectives: Glomerular filtration rate (GFR), the rate at which the kidney filters the waste from the blood, is considered the most useful test to measure the level of renal function and determine the stage of kidney disease. Quantitative SPECT/CT is potentially useful for more accurate and reliable GFR measurement than conventional planar scintigraphy [1]. However, manual drawing of a volume of interest (VOI) on renal parenchyma in CT images is labor-intensive and time-consuming job usually taking around 15 min per scan. The aim of this study is to develop fully automated GFR quantification method based on deep learning approach to the three-dimensional (3D) segmentation of kidney parenchyma in CT.

Methods: Two hundred and ninety (290) patients underwent quantitative 99mTc-DTPA SPECT/CT (GE Discovery NM/CT 670) scans. One-min SPECT data were acquired in a continuous mode 2 min after the intravenous injection of 370 MBq 99mTc-DTPA. The SPECT images were corrected for attenuation, scatter, and collimator-detector response, and cross-calibrated with a dose calibrator. A nuclear medicine physician drew 2D region of interest (ROI) on renal parenchyma in every 80 to 100 coronal CT slices using vendor’s Q. Metrix software, which provides automatic ROI interpolation between the slices. To reduce the discontinuity in 3D space caused by the 2D ROI drawing, we applied 3D volume smoothing and morphological operations. We used modified 3D U-Net that consists of the contraction and expansion paths and learns an end-to-end mapping between CT and renal parenchyma segmented volumes. Each path has 4 sequential layers composed of a convolution with 3 × 3 × 3 kernels, ReLU (Rectified Linear Unit) and pooling layers (1 × 1 × 1 kernels, Sigmoid for last layer of expansion path). Each layer is updated using the error back-propagation with Adam (adaptive moment estimation) optimizer. Symmetric skip connections between convolutional and up-convolutional layers are used. The U-Net was trained using 240 randomly selected datasets and validated using 50 datasets. Before the training, CT images were down-sampled to 200 × 200 × 160 (2.5 mm3) and cropped into a 144 × 86 × 70 matrix to reduce the input data size. For the quantitative performance evaluation, Dice similarity coefficient between manual drawing and deep learning output was calculated. We calculate % injected dose (%ID) by applying the deep learning output (3D VOI) to the quantitative SPECT images. We also assessed the correlation between the GFR measurements (%ID × 9.1462 + 23.0653) using both segmentation methods [1]. To confirm the consistency of performance, we performed five-fold cross-validation.

Results: We could automatically segment the kidneys in CT images using the proposed method with remarkably high Dice similarity coefficient relative to the manual segmentation (mean ± SD = 0.82 ± 0.054). Although manual segmentation resulted in the discontinuity between slices and vendor’s program sometimes offered wrong ROI interpolation results, the proposed deep learning approach provided 3D kidney parenchyma VOI with no such discontinuity between slices. The GFR values derived using manual and automatic segmentation methods were strongly correlated (R2 = 0.94). The absolute difference between the GFR values using manual (45.40±7.48 ml/min) and automatic (46.05±7.32 ml/min) methods was only 3.30±2.89% (left kidney: 3.70±3.16%, right: 3.58±3.18%) in the first cross-validation. The absolute difference obtained in the other cross-validations were 5.75±4.91%, 5.29±3.78%, 3.08±2.81% and 3.41±3.55%, respectively. Conclusion: The proposed deep learning approach to the 3D segmentation of kidney parenchyma in CT enables fast and accurate GFR measurement. Accordingly, this method will be useful for facilitating the GFR measurement using the quantitative SPECT/CT technology.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
Junyoung Park, Sungwoo Bae, Seongho Seo, Ji In Bang, Won-Woo Lee, Jae Sung Lee
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 26;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
Junyoung Park, Sungwoo Bae, Seongho Seo, Ji In Bang, Won-Woo Lee, Jae Sung Lee
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 26;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

Deep Learning In Molecular Imaging Studies

  • Automated detection and quantification of prostatic PSMA uptake in SPECT/CT using a deep learning algorithm for segmentation of pelvic anatomy
  • Improved myocardial perfusion PET imaging using artificial neural networks
Show more Deep Learning In Molecular Imaging Studies

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire