Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleMolecular Imaging

The Characterization of 18F-hGTS13 for Molecular Imaging of xC− Transporter Activity with PET

Corinne Beinat, Gayatri Gowrishankar, Bin Shen, Israt S. Alam, Elise Robinson, Tom Haywood, Chirag B. Patel, Emily Carmen Azevedo, Jessa B. Castillo, Ohad Ilovich, Norman Koglin, Heribert Schmitt-Willich, Mathias Berndt, Andre Mueller, Marion Zerna, Ananth Srinivasan and Sanjiv Sam Gambhir
Journal of Nuclear Medicine December 2019, 60 (12) 1812-1817; DOI: https://doi.org/10.2967/jnumed.119.225870
Corinne Beinat
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gayatri Gowrishankar
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bin Shen
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Israt S. Alam
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elise Robinson
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tom Haywood
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chirag B. Patel
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
2Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Emily Carmen Azevedo
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jessa B. Castillo
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ohad Ilovich
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Norman Koglin
3Life Molecular Imaging GmbH (formerly Piramal Imaging) GmbH, Berlin, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heribert Schmitt-Willich
3Life Molecular Imaging GmbH (formerly Piramal Imaging) GmbH, Berlin, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mathias Berndt
3Life Molecular Imaging GmbH (formerly Piramal Imaging) GmbH, Berlin, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andre Mueller
3Life Molecular Imaging GmbH (formerly Piramal Imaging) GmbH, Berlin, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marion Zerna
3Life Molecular Imaging GmbH (formerly Piramal Imaging) GmbH, Berlin, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ananth Srinivasan
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sanjiv Sam Gambhir
1Department of Radiology, Molecular Imaging Program at Stanford (MIPS), Stanford University School of Medicine, Stanford, California
4Departments of Bioengineering and Materials Science and Engineering, Bio-X, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

The aim of this study was development of an improved PET radiotracer for measuring xC− activity with increased tumor uptake and reduced uptake in inflammatory cells compared with (S)-4-(3-18F-fluoropropyl)-l-glutamate (18F-FSPG). Methods: A racemic glutamate derivative, 18F-hGTS13, was evaluated in cell culture and animal tumor models. 18F-hGTS13 was separated into C5 epimers, and the corresponding 18F-hGTS13-isomer1 and 18F-hGTS13-isomer2 were evaluated in H460 tumor–bearing rats. Preliminary studies investigated the cellular uptake of 18F-hGTS13-isomer2 in multiple immune cell populations and states. Results: 18F-hGTS13 demonstrated excellent H460 tumor visualization with high tumor-to-background ratios, confirmed by ex vivo biodistribution studies. Tumor-associated radioactivity was significantly higher for 18F-hGTS13 (7.5 ± 0.9 percentage injected dose [%ID]/g, n = 3) than for 18F-FSPG (4.6 ± 0.7 %ID/g, n = 3, P = 0.01). 18F-hGTS13-isomer2 exhibited excellent H460 tumor visualization (6.3 ± 1.1 %ID/g, n = 3) and significantly reduced uptake in multiple immune cell populations relative to 18F-FSPG. 18F-hGTS13-isomer2 exhibited increased liver uptake relative to 18F-FSPG (4.6 ± 0.8 vs. 0.7 ± 0.01 %ID/g), limiting its application in hepatocellular carcinoma. Conclusion: 18F-hGTS13-isomer2 is a new PET radiotracer for molecular imaging of xC− activity that may provide information on tumor oxidation states. 18F-hGTS13-isomer2 has potential for clinical translation for imaging cancers of the thorax because of the low background signal in healthy tissue.

  • xC− transporter
  • oxidative stress
  • cancer metabolism
  • PET imaging
  • 18F-hGTS13

The increased uptake of glucose has been exploited clinically to detect tumors and their response to treatment by PET imaging with 18F-FDG (1,2). However, 18F-FDG has limitations, including nonspecificity toward inflammation and high background accumulation in tissues with high glycolytic rates, such as brain and heart (3). To overcome the limitations of 18F-FDG and provide additional information about tumor biology, other fundamental processes in tumor cells would be of utility for detecting cancer, monitoring treatment response, and predicting chemoresistance (4). The enhanced rate of glucose and glutamine uptake to increase cell mass results in elevated levels of oxidative intermediates and subsequent altered redox potential and excess of reactive oxygen species (5). Thiol-containing molecules, including l-cysteine and the tripeptide glutathione (GSH), are key cellular components to neutralize these conditions, and their consumption leads to detoxification of reactive oxygen species and other electrophiles (e.g., chemotherapeutics) (6). GSH, the major thiol-containing endogenous antioxidant, is found in millimolar intracellular concentrations and serves as a redox buffer against various sources of oxidative stress (7–9). A constant supply of GSH and its precursory components is essential for cell survival and provides an advantage for tumor growth. l-cysteine plays a crucial role as a reactive oxygen species scavenger and is also the rate-limiting constituent in GSH biosynthesis (10). l-cysteine is provided to cells via system xC−, the amino acid transporter that mediates the sodium-independent exchange of extracellular l-cystine and intracellular l-glutamate across the plasma membrane (Fig. 1) (11). Intracellularly, l-cystine is reduced to 2 molecules of l-cysteine, which can be used for GSH biosynthesis. System xC− is a heterodimeric transporter consisting of 2 subunits: the light-chain xCT (SLC7A11) conferring substrate specificity and the heavy-chain 4F2hc (SLC3A2) (12). It is noteworthy that xC− is unable to differentiate between its natural substrates l-cystine and l-glutamate for the inward direction of transport (13). The increased activity of xC− in tumors has previously been exploited by PET imaging with (4S)-4-(3-18F-fluoropropyl)-l-glutamate (18F-FSPG). Pilot clinical studies have been completed examining dosimetry in healthy volunteers and tumor detection in non–small cell lung carcinoma, breast cancer (14), hepatocellular cancer (15), and intracranial malignancies (16). Additional radiotracers, including 18F-5-fluoro-aminosuberic acid, targeting the xC− transporter have also been described (17,18). Because the xC− transporter plays important roles in other, non–tumor-related, diseases, 18F-FSPG has high uptake and retention in inflammatory cells (19), including activated T cells and microglia, resulting in the investigation of 18F-FSPG to visualize multiple sclerosis (20) and cerebral ischemia (21). With these considerations in mind, second-generation radiotracers for molecular imaging of xC− were designed (WO/2012/150220), with potential for reduced uptake in inflammatory cells and enhanced tumor visualization. Incorporation of an ultraviolet active moiety was pursued to facilitate radiosynthesis and quality control because 18F-FSPG requires derivatization for quality control analysis at our institution. The compound hGTS13 was selected for further evaluation.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Graphical representation of system xC−, comprising heavy-chain and light-chain xC transporter coupled by disulfide bond (S–S). xC− imports extracellular cystine in exchange for intracellular glutamate in 1:1 ratio. 18F-hGTS13 and 18F-FSPG bear structural similarities to glutamate and are transported into cell via xC−.

MATERIALS AND METHODS

General

Human A549 and H460 tumor cell lines were obtained from ATCC and maintained according to the provider’s protocols. Chemicals were obtained from Sigma-Aldrich, Tocris, and Thermo Fisher-Scientific. Synthesis of the precursor, tosylate di-tert-butyl (2S)-2-[(tert-butoxycarbonyl)amino]-5-{4-[2-(tosyloxy)ethoxy]benzyl}hexanedioate (compound 1), was adopted from a patent (WO/2012/150220). 18F-FSPG was obtained from Stanford Cyclotron and Radiochemistry Facility.

Radiochemistry

18F-hGTS13 was synthesized from nucleophilic displacement of the tosylate group within compound 1 and subsequent deprotection (Supplemental Fig. 1). Full details can be found in the supplemental materials (available at http://jnm.snmjournals.org). The identity of 18F-hGTS13 was confirmed through coinjection with reference standard 19F-hGTS13 (Supplemental Fig. 2).

Chiral High-Performance Liquid Chromatography

C5 epimers of compound 1 were separated by high-performance liquid chromatography using a chiral column (Lux 5-μM amylose-1, 150 × 4.6 mm). An isocratic mobile phase of hexane/isopropanol (85:10) + 0.1% diethylamine was used (flow rate, 1.0 mL/min) to give baseline separation of C5 epimers (retention time, 6.4 and 8.5 min).

Cell Uptake Studies

A549 and H460 cells (2 × 105) were plated into 12-well plates the day before uptake studies (n = 3 per condition). On the day of the uptake, prewarmed Hanks balanced salt solution containing about 0.2 MBq of 18F-hGTS13 was added to individual wells (1 mL per well). Cells were incubated at 37°C and 5% CO2 over a specified time course. For competition studies, wells were pretreated 10 min before radiotracer addition with the appropriate amino acid or (S)-4-carboxyphenylglycine to give a final concentration of 1 mM (n = 3 replicates per inhibitor). Hanks balanced salt solution containing the inhibitors was aspirated, and fresh Hanks balanced salt solution containing the appropriate inhibitor and 0.2 MBq of 18F-hGTS13 was added and incubated at 37°C and 5% CO2 for 60 min. Cells were processed as previously described (22).

xCT Small Inhibitory RNA (siRNA)

A549 cells (6 × 104) were seeded in 12-well plates in antibiotic-free F-12K medium the day before addition of siRNA transfection with lipofectamine 2000 according to the manufacturer’s instructions. Specific siRNA sequences targeting the light-chain xCT were produced by Thermo Scientific using the following sequence: CGAGTCTGGGTGGAACTCCTCATAA. Scrambled siRNA (CGAGGTCGGTGTCAACTCCATGTAA) was used as a control. siRNA was added at a final concentration of 25 nM, and xCT knockdown was achieved 48 h after transfection, as confirmed through quantitative reverse-transcription polymerase chain reaction (PCR) and 14C-cystine uptake studies. 18F-hGTS13 uptake was measured over 60 min in cells treated with xCT siRNA and control siRNA at 48 h after transfection. Cells were processed for tracer uptake studies as described above using 18F-hGTS13 or 14C-cystine. For 14C-cystine measurements, 10 mL of scintillation liquid were added to lysates and measured using an LS 6500 multipurpose scintillation counter (Beckman Coulter). Untreated cells were used as an additional control, measured 72 h after seeding.

RNA Isolation, Reverse Transcription, and Quantitative Reverse-Transcription PCR

Total RNA was extracted with an RNeasy mini kit (Qiagen). cDNA was synthesized with M-MLV reverse transcriptase (Thermo Fisher Scientific) using oligo(dT) primers according to the manufacturer’s protocol. Real-time PCR was performed on the iCycler real-time PCR detection system (Bio-Rad) using SYBR green PCR master mix (Life Technologies) with primers specific for xCT and 18S ribosomal RNA using annealing and extension temperatures of 56°C and 72°C, respectively. xCT was amplified using primers (forward) 5′-CAAATGCAGTGGCAGTGACC and (reverse) 5′-AGACAGCAAACACACCACCG, and 18S ribosomal RNA was amplified using primers (forward) 5′-GTAACCCGTTGAACCCCATT and (reverse) 5′-CCATCCAATCGGTAGTAGCG. Transcript levels were normalized to the level of 18S ribosomal RNA messenger RNA. The comparative quantitation method (ΔΔCt) was used to compare the different samples and transform them to absolute values with 2–ΔΔCt for determining relative fold changes.

Primary Human Immune Cell Isolation, Activation, and Radiotracer Uptake Studies

Human peripheral blood mononuclear cells were obtained from fresh buffy coat fractions (Stanford Blood Center) using Ficoll-Paque Plus following the manufacturer’s instructions (GE Healthcare). T cells, B cells, and monocytes were isolated using a human naïve pan T cell isolation kit, human B cell enrichment kit, and human monocyte isolation kit, respectively (Stemcell Technologies). Isolated cells were subsequently maintained in resting or activated conditions for 2 d. T cells were activated with the T-cell activation/expansion kit using anti-CD3/2/28 coated particles (Miltenyi Biotec). B cells were activated with (S)-4-carboxylphenylglycine oligodeoxynucleotide 2006 (1 μM; Sigma-Aldrich). Monocytes were activated using lipopolysaccharide (1 μg/mL, Escherichia coli O55:B5; Sigma-Aldrich) (23–25). Activation was confirmed by assessing significant changes in morphology in activated versus resting cells.

Radiotracer uptake experiments were performed 48 h after activation. Cells from the same donor were used to evaluate uptake of both 18F-hGTS13-isomer2 and 18F-FSPG to minimize donor-dependent variation. T cells, B cells, and monocytes (3 × 105 per well) were prepared in prewarmed Hanks balanced salt solution in a 96-well plate and incubated with about 0.8 MBq of radiotracer per well for 1 h. Cells were processed as previously described (26).

Animal Studies

All experiments involving animals were in accordance with protocols approved by the Institutional Animal Care and Use Committee at Stanford University and were performed in accord with the National Institutes of Health Guide for the Care and Use of Laboratory Animals. H460 subcutaneous tumor models were developed as previously described (27). PET/CT imaging of rats was performed with a small-animal hybrid scanner (Inveon; Siemens) and analyzed according to methods previously described by our group (22). Approximately 15 MBq (400 μCi) of each radiotracer was administered to rats intravenously. For comparative radiotracer studies, the same cohort of rats was scanned with each radiotracer; representative images show comparison within the same animal. Static PET scans were acquired 60 min after injection of radioactivity, and the acquisition of dynamic PET scans commenced immediately before injection of radiotracer. No partial-volume correction was completed.

Ex Vivo Biodistribution Studies

At completion of PET imaging studies, about 80 min after radiotracer administration, the rats were sacrificed by terminal cardiac puncture and tissues harvested. Radioactivity within individual tissues was determined on a γ-counter. Radioactivity standards were counted for data normalization. Data were expressed as percentage injected dose (%ID)/g.

Statistical Analyses

Data were expressed as mean ± SD. Statistical significance was determined using a 2-tailed Student t test, with P values of less than 0.05 being considered significant. For analysis across multiple samples, 1- or 2-way ANOVA was used, followed by multiple comparisons of means with Bonferroni adjustment.

RESULTS

Rapid and Extensive Uptake of 18F-hGTS13 in Cell Culture

Cell culture studies showed rapid cellular uptake in A549 and H460 tumor cells after addition of 18F-hGTS13, with uptake values of 9.7% ± 2.8% and 21.6% ± 3.6% in A549 cells and 15.8% ± 1.5% and 32.1% ± 0.8% in H460 cells at 30 and 60 min, respectively (Fig. 2A). Strong inhibition of 18F-hGTS13 uptake was evident in the presence of l-glutamate, l-cystine, or the system xC−–specific inhibitor (S)-4-carboxylphenylglycine. However, no inhibition of uptake was evident in the presence of l-aspartate. The competition profile of 18F-hGTS13 in both A549 and H460 cells is highlighted in Figure 2B and indicates the specificity of this radiotracer for system xC−. We additionally modulated light-chain xCT protein expression in vitro through siRNA; reduced xCT expression was confirmed through PCR and 14C-cystine uptake (Supplemental Fig. 3). A significant reduction in 18F-hGTS13 uptake (78%, P < 0.0001, n = 3 per condition) was evident in xCT siRNA cells compared with those transfected with control siRNA (Fig. 2C). Competition studies in the presence of l-glutamine, l-leucine, and l-alanine suggest possible involvement of systems L and B+0 in the uptake of 18F-hGTS13, particularly in A549 cells (Supplemental Fig. 4), whereas additional knockdown studies (Fig. 2C and Supplemental Fig. 5) indicate specificity to system xC− and a similar specificity profile to 18F-FSPG.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) Cellular uptake of 18F-hGTS13 over time in A549 and H460 lung carcinoma cell lines. (B) Competition studies of 18F-hGTS13 in A549 and H460 cells at 60 min after addition of radioactivity. There was significant interaction on inhibitor and cell line (****P < 0.0001, n = 3 per condition). In A549 and H460 cells, 18F-hGTS13 uptake was significantly reduced in l-glutamate–treated cells (P < 0.0001 for both cell lines; A549, 81% decrease; H460, 94% decrease), l-cystine–treated cells (P < 0.0001 for both cell lines; A549, 93% decrease; H460, 97% decrease), and (S)-4-carboxylphenylglycine (CPG)–treated cells (P < 0.0001 for both cell lines; A549, 78% decrease; H460, 88% decrease). Nonsignificant reduction was observed in l-aspartate–treated cells (P = 0.74 for A549 cells, P = 0.59 for H460 cells). (C) Reduced 18F-hGTS13 uptake was evident in A549 cells treated with xCT siRNA compared with control siRNA (P < 0.0001, n = 3 per condition). No difference in uptake was evident in untreated cells compared with control siRNA (P = 0.10, n = 3 per condition).

Evaluation of 18F-hGTS13 in H460 Tumor–Bearing Rats

In xenograft models of H460 cells, 10-min static PET/CT imaging was completed 60 min after injection of 18F-hGTS13. The distribution of 18F-hGTS13 was characterized by renal clearance and liver uptake (Fig. 3). High tumor uptake (7.5 ± 0.9 %ID/g) was evident at 60 min after injection of radioactivity. Rats bearing H460 tumors were additionally scanned 1 d beforehand with 18F-FSPG PET/CT, and levels of radioactivity within H460 tumors were significantly lower with 18F-FSPG than with 18F-hGTS13 (4.6 ± 0.7, P = 0.01, n = 3). Ex vivo biodistribution studies after the 18F-hGTS13 PET scan corroborated the PET imaging results (Fig. 3C). 18F-hGTS13 radioactivity in the H460 tumor was determined to be 6.4 ± 0.9 %ID/g, which was significantly higher than that of blood (0.6 ± 0.2 %ID/g, P = 0.0042, n = 3) and muscle (0.1 ± 0.05 %ID/g, P = 0.0004, n = 3).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A) Representative maximum-intensity-projection PET/CT images of rats bearing subcutaneous H460 tumors 60 min after intravenous administration of ∼15 MBq of 18F-FSPG or 18F-hGTS13. (B) Levels of radioactivity in H460 tumors at 60 min after injection of radioactivity with 18F-FSPG and 18F-hGTS13 (P = 0.01, n = 3) and in liver and kidneys determined from PET imaging. (C) Ex vivo biodistribution at ∼80 min after injection of 18F-hGTS13 in 3 animals. **P = 0.0042. ***P = 0.0004. Sml Int = small intestine.

Separation of 18F-hGTS13 C-5 Epimers and Evaluation in H460 Tumor–Bearing Rats

Chiral high-performance liquid chromatography of compound 1 gave baseline separation of C-5 epimers with retention times of 6.4 and 8.5 min. No efforts were made to resolve the absolute stereochemistry of the isomers at this stage. They were defined as isomer 1 and isomer 2 based on order of elution from the chiral column. Radiolabeling of the C-5 epimers of compound 1 to give 18F-hGTS13-isomer1 and 18F-hGTS13-isomer2 was achieved using the method described for the racemic mixture. 18F-hGTS13-isomer1 and 18F-hGTS13-isomer2 were synthesized, respectively, in 4.4% (n = 1) and 5.1% ± 1.7% (n = 2) radiochemical yield, non–decay-corrected. H460 tumor–bearing rats were evaluated with static PET/CT imaging of 18F-hGTS13-isomer1 and 18F-hGTS13-isomer2 (4 d apart) (Fig. 4). A significant reduction in liver uptake was observed with 18F-hGTS13-isomer2 compared with 18F-hGTS13-isomer1 at 60 min after injection of radioactivity (4.7 ± 0.9 vs. 8.5 ± 0.4 %ID/g, P = 0.01, n = 3). There were similar amounts of radioactivity retained in H460 tumors between 18F-hGTS13-isomer1 and 18F-hGTS13-isomer2 (6.7 ± 1.1 vs. 6.3 ± 1.6 %ID/g, P = 0.8, n = 3). Further studies were completed with 18F-hGTS13-isomer2 based on the improved biodistribution profile and similar levels of radioactivity retained in H460 tumors. Dynamic PET/CT imaging with 18F-hGTS13-isomer2 was completed over a 60-min period (Fig. 5). High H460 tumor accumulation was evident throughout the scan, with radiotracer uptake continuing to rise over the 60-min period (4.7 ± 1.3 %ID/g at 60 min after injection), suggesting that peak tumor radiotracer uptake may occur beyond the 60-min acquisition period. Levels of radioactivity present in healthy lung tissue and muscle were low throughout the scan, highlighting the potential for a high tumor-to-background ratio in cancers of the thorax (Supplemental Fig. 6A). Results of the PET imaging studies were confirmed through ex vivo biodistribution (Supplemental Fig. 6B).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

(A) Representative maximum-intensity-projection PET/CT images at 60 min after tail-vein injection of ∼15 MBq of 18F-hGTS13-isomer1 or 18F-hGTS13-isomer2 in H460 tumor–bearing rats. (B) Levels of radioactivity retained in H460 tumors and liver (P = 0.01, n = 3).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

(A) Representative summed 25- to 60-min maximum-intensity-projection PET/CT image of H460 tumor–bearing rat. (B) Time–activity curves reflecting 18F-hGTS13-isomer2 tumor uptake.

Evaluation of 18F-hGTS13-Isomer2 in Immune Cell Populations Compared with 18F-FSPG

We evaluated the uptake of 18F-hGTS13-isomer2 compared with 18F-FSPG in primary human T cells, B cells, and monocytes, which are key immune cell populations in various inflammatory diseases and the tumor microenvironment. These studies revealed a dramatic increase in the uptake of 18F-FSPG in activated versus resting T cells (72-fold, P < 0.0001, n = 3) (Fig. 6A), consistent with previous studies (26). In contrast, the increased uptake of 18F-hGTS13-isomer2 in activated T cells was attenuated; there was a 17-fold increase relative to resting T cells (P = 0.0002, n = 3). A similar trend was observed with B cells, with 18F-FSPG exhibiting a 3-fold increased uptake in activated versus resting B cells (P = 0.0003, n = 3, Fig. 6B). In contrast, 18F-hGTS13-isomer2 displayed a 2-fold increase in uptake in activated versus resting B cells (P = 0.189, n = 3). Finally in monocytes, 18F-FSPG displayed a 2-fold increased uptake in activated versus resting monocytes (P = 0.0022, n = 3) whereas 18F-hGTS13-isomer2 exhibited a 4-fold increased uptake in activated versus resting monocytes (P < 0.0001, n = 3, Fig. 6C). However, 18F-hGTS13-isomer2 absolute uptake values were considerably lower.

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Cellular uptake of 18F-FSPG and 18F-hGTS13-isomer2 in resting and activated human T cells (18F-FSPG resting vs. activated, P < 0.0001, n = 3; 18F-hGTS13-isomer2 resting vs. activated, P = 0.0002, n = 3) (A), B cells (18F-FSPG resting vs. activated, P = 0.0003, n = 3; 18F-hGTS13-isomer2 resting vs. activated, P = 0.189, n = 3) (B), and monocytes (18F-FSPG resting vs. activated, P = 0.0022, n = 3; 18F-hGTS13-isomer2 resting vs. activated, P < 0.0001, n = 3) (C).

DISCUSSION

System xC− represents an attractive target for PET imaging because of its involvement in mediating cellular response to oxidative stress and detoxification processes that support tumor progression and therapy resistance. Molecular imaging of xC− activity provides additional information over other amino acid–based PET probes currently being explored, including 18F-FET and 18F-FDOPA, which are taken up primarily by l-type amino acid transporter mechanisms and largely reflect nutrient uptake to support increased biomass and proliferative energy demands (28). The present work describes the characterization of a novel radiotracer, 18F-hGTS13-isomer2, for PET imaging of xC− activity and evaluation in cell culture and preclinical models.

The capacity of cancer cells to achieve multidrug resistance remains an obstacle for successful chemotherapy. xC− plays a vital role in the development of multidrug resistance in cancer. Increased xC− expression is associated with chemoresistance of tumor cells; a negative correlation is evident between its expression and drug potency across NCI-60 cancer cell lines (29). A negative correlation is similarly evident between xC− expression and the anticancer activity of compounds that contain structural features amenable to GSH reactivity, including Mannich base, therefore indicating that GSH-dependent inactivation is a potential mechanism through which xC− expression induces chemoresistance (30). Molecular imaging of xC− activity provides the potential to visualize this important target in oncology and gain insight into the mechanisms of cancer drug resistance. PET imaging of xC− activity with 18F-hGTS13-isomer2 may provide the potential to visualize tumors and provide valuable insight into chemoresistance, particularly in cancers of the thorax because of the low background signal in healthy tissue. Although 18F-hGTS13-isomer2 displayed a favorable increase in tumor uptake, an increase in radiotracer uptake was also evident in the liver compared with 18F-FSPG, potentially limiting the ability of this radiotracer for imaging hepatocellular cancer, for which 18F-FSPG has shown utility (31). There are no anticipated concerns in radiation dosimetry based on the increased liver uptake. Key applications in which 18F-hGTS13-isomer2 may have advantages over 18F-FSPG include lung cancer, breast cancer, and primary and metastatic brain lesions.

Several lines of evidence suggest the role of xC− in regulating the innate and adaptive immune response. Activation of monocytes is associated with production of reactive oxygen species. The xC− is subsequently upregulated potentially as an autoprotective response during activation of these cells (32). Similarly, naïve T cells are known to be metabolically dependent on antigen-presenting cells to fulfil their cysteine requirements due to the lack of xC− and limited cysteine availability in the extracellular space. However, on activation of T cells, expression of xC− becomes upregulated and provides activated T cells with cysteine necessary for proliferation (33,34). Aside from malignant cells, the tumor microenvironment contains a complex milieu of immune cells including T- and B-lymphocytes, tumor-associated macrophages and monocytes, and fibroblasts and vascular endothelial cells (35). The xC− expression and uptake of 18F-FSPG in several of these cell populations have been previously investigated (26,33,36). Although 18F-hGTS13-isomer2 uptake was elevated in activated versus resting immune cells, the differential observed between activated and resting cells, as well as the absolute levels of uptake, was much lower than observed with 18F-FSPG. Although both compounds are specifically taken up through the same transporter, structural differences (length of the carbon backbone and the side chain) may cause more directed inward channeling of one compound over the other depending on the context of the transporter activity, that is, cancer or inflammation, and associated driving forces. Future studies including immune cell blocking studies will be required to evaluate this in detail. Additional studies including in vivo inflammation models will be required to determine whether these findings persist in animal models. Nevertheless, the results of 18F-hGTS13-isomer2 in cell culture and in animal models are promising and highlight the potential of this radiotracer with improved specificity for imaging cancer cells in the tumor microenvironment.

CONCLUSION

18F-hGTS13-isomer2 is a new radiotracer for molecular imaging of xC− activity, specifically taken up by xC− in cell culture and with high tumor accumulation in animal models. Molecular imaging of xC− activity with 18F-hGTS13-isomer2 has potential for improved tumor detection and staging compared with other xC−–targeting radiotracers and may assist in directing therapeutic strategies by visualizing metabolic adaptations to oxidative stress. Future studies are required to elucidate the uptake of 18F-hGTS13-isomer2 in inflammation states in vivo and to associate radiotracer uptake with chemoresistance. Clinical translation of 18F-hGTS13-isomer2 is under way for molecular imaging of cancers of the thorax.

DISCLOSURE

This work was partly supported by Life Molecular Imaging GmbH (formerly Piramal Imaging). Corinne Beinat acknowledges receipt of a Stanford Translational Research and Applied Medicine Fellowship. The authors acknowledge support from Thomas Brumby, Georg Kettschau, and Timo Stellfeld of Bayer Pharma (Berlin, Germany) in the development of this compound. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

  • QUESTION: The goal of this study was development of a novel radiotracer for molecular imaging of xC− activity with improved tumor uptake and reduced uptake in inflammatory cells.

  • PERTINENT FINDINGS: 18F-hGTS13-isomer2 exhibited excellent H460 tumor visualization and significantly reduced uptake in multiple immune cell populations.

  • IMPLICATIONS FOR PATIENT CARE: 18F-hGTS13-isomer2 has potential for clinical translation for imaging cancers of the thorax because of the low background signal in healthy tissue.

Acknowledgments

We thank the Radiochemistry Facility and Small Animal Imaging Facility at Stanford University.

Footnotes

  • Published online Jun. 6, 2019.

  • © 2019 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Kelloff GJ,
    2. Hoffman JM,
    3. Johnson B,
    4. et al
    . Progress and promise of FDG-PET imaging for cancer patient management and oncologic drug development. Clin Cancer Res. 2005;11:2785–2808.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Pantel AR,
    2. Ackerman D,
    3. Lee SC,
    4. Mankoff DA,
    5. Gade TP
    . Imaging cancer metabolism: underlying biology and emerging strategies. J Nucl Med. 2018;59:1340–1349.
    OpenUrl
  3. 3.↵
    1. Shreve PD,
    2. Anzai Y,
    3. Wahl RL
    . Pitfalls in oncologic diagnosis with FDG PET imaging: physiologic and benign variants. Radiographics. 1999;19:61–77.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Mankoff DA,
    2. Eary JF,
    3. Link JM,
    4. et al
    . Tumor-specific positron emission tomography imaging in patients: [18F] fluorodeoxyglucose and beyond. Clin Cancer Res. 2007;13:3460–3469.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Levine AJ,
    2. Puzio-Kuter AM
    . The control of the metabolic switch in cancers by oncogenes and tumor suppressor genes. Science. 2010;330:1340–1344.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Okuno S,
    2. Sato H,
    3. Kuriyama-Matsumura K,
    4. et al
    . Role of cystine transport in intracellular glutathione level and cisplatin resistance in human ovarian cancer cell lines. Br J Cancer. 2003;88:951–956.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Meister A
    . Glutathione metabolism. Methods Enzymol. 1995;251:3–7.
    OpenUrlCrossRefPubMed
  8. 8.
    1. DeBerardinis RJ,
    2. Cheng T
    . Q’s next: the diverse functions of glutamine in metabolism, cell biology and cancer. Oncogene. 2010;29:313–324.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Estrela JM,
    2. Ortega A,
    3. Obrador E
    . Glutathione in cancer biology and therapy. Crit Rev Clin Lab Sci. 2006;43:143–181.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Lu SC
    . Glutathione synthesis. Biochim Biophys Acta. 2013;1830:3143–3153.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Bridges RJNN,
    2. Patel SA
    . System xc− cystine/glutamate antiporter: an update on molecular pharmacology and roles within the cns. Br J Pharmacol. 2012;165:20–34.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Bassi MT,
    2. Gasol E,
    3. Manzoni M,
    4. et al
    . Identification and characterisation of human xct that co-expresses, with 4f2 heavy chain, the amino acid transport activity system xc. Pflugers Arch. 2001;442:286–296.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Patel SA,
    2. Warren BA,
    3. Rhoderick JF,
    4. Bridges RJ
    . Differentiation of substrate and non-substrate inhibitors of transport system xc−: an obligate exchanger of l-glutamate and l-cystine. Neuropharmacology. 2004;46:273–284.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Baek S,
    2. Choi CM,
    3. Ahn SH,
    4. et al
    . Exploratory clinical trial of (4s)-4-(3-[18F]fluoropropyl)-l-glutamate for imaging xc− transporter using positron emission tomography in patients with non-small cell lung or breast cancer. Clin Cancer Res. 2012;18:5427–5437.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Baek S,
    2. Mueller A,
    3. Lim Y-S,
    4. et al
    . (4s)-4-(3-18F-fluoropropyl)-l-glutamate for imaging of xc− transporter activity in hepatocellular carcinoma using pet: preclinical and exploratory clinical studies. J Nucl Med. 2013;54:117–123.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Mittra ES,
    2. Koglin N,
    3. Mosci C,
    4. et al
    . Pilot preclinical and clinical evaluation of (4S)-4-(3-[18F]fluoropropyl)-l-glutamate (18F-FSPG) for PET/CT imaging of intracranial malignancies.PLoS One. 2016;11:e0148628.
    OpenUrl
  17. 17.↵
    1. Webster JM,
    2. Morton CA,
    3. Johnson BF,
    4. et al
    . Functional imaging of oxidative stress with a novel PET imaging agent, 18F-5-fluoro-l-aminosuberic acid. J Nucl Med. 2014;55:657–664.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Yang H,
    2. Jenni S,
    3. Colovic M,
    4. et al
    . 18F-5-fluoroaminosuberic acid as a potential tracer to gauge oxidative stress in breast cancer models. J Nucl Med. 2017;58:367–373.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Chae SY,
    2. Choi CM,
    3. Shim TS,
    4. et al
    . Exploratory clinical investigation of (4S)-4-(3-18F-fluoropropyl)-l-glutamate PET of inflammatory and infectious lesions. J Nucl Med. 2016;57:67–69.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Martín A,
    2. Vázquez-Villoldo N,
    3. Gómez-Vallejo V,
    4. et al
    . In vivo imaging of system xc− as a novel approach to monitor multiple sclerosis. Eur J Nucl Med Mol Imaging. 2016;43:1124–1138.
    OpenUrl
  21. 21.↵
    1. Domercq M,
    2. Szczupak B,
    3. Gejo J,
    4. et al
    . PET imaging with [18F]FSPG evidences the role of system xc− on brain inflammation following cerebral ischemia in rats. Theranostics. 2016;6:1753–1767.
    OpenUrl
  22. 22.↵
    1. Beinat C,
    2. Haywood T,
    3. Chen YS,
    4. et al
    . The utility of [18F]DASA-23 for molecular imaging of prostate cancer with positron emission tomography. Mol Imaging Biol. 2018;20:1015–1024.
    OpenUrl
  23. 23.↵
    1. Krieg AM,
    2. Yi A-K,
    3. Matson S,
    4. et al
    . Cpg motifs in bacterial DNA trigger direct b-cell activation. Nature. 1995;374:546–549.
    OpenUrlCrossRefPubMed
  24. 24.
    1. Trickett A,
    2. Kwan YL
    . T cell stimulation and expansion using anti-cd3/cd28 beads. J Immunol Methods. 2003;275:251–255.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Plevin RE,
    2. Knoll M,
    3. McKay M,
    4. Arbabi S,
    5. Cuschieri J
    . The role of lipopolysaccharide structure in monocyte activation and cytokine secretion. Shock. 2016;45:22–27.
    OpenUrlCrossRef
  26. 26.↵
    1. Hoehne A,
    2. James ML,
    3. Alam IS,
    4. et al
    . [18F]FSPG-PET reveals increased cystine/glutamate antiporter (xc−) activity in a mouse model of multiple sclerosis. J Neuroinflammation. 2018;15:55.
    OpenUrl
  27. 27.↵
    1. Koglin N,
    2. Mueller A,
    3. Berndt M,
    4. et al
    . Specific PET imaging of xc transporter activity using a 18F-labeled glutamate derivative reveals a dominant pathway in tumor metabolism. Clin Cancer Res. 2011;17:6000–6011.
    OpenUrlAbstract/FREE Full Text
  28. 28.↵
    1. Sun A,
    2. Liu X,
    3. Tang G
    . Carbon-11 and fluorine-18 labeled amino acid tracers for positron emission tomography imaging of tumors. Front Chem. 2018;5:124.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Huang Y,
    2. Dai Z,
    3. Barbacioru C,
    4. Sadée W
    . Cystine-glutamate transporter slc7a11; in cancer chemosensitivity and chemoresistance. Cancer Res. 2005;65:7446–7454.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Dai Z,
    2. Huang Y,
    3. Sadee W,
    4. Blower P
    . Chemoinformatics analysis identifies cytotoxic compounds susceptible to chemoresistance mediated by glutathione and cystine/glutamate transport system xc. J Med Chem. 2007;50:1896–1906.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Kavanaugh G,
    2. Williams J,
    3. Morris AS,
    4. et al
    . Utility of [18F]FSPG PET to image hepatocellular carcinoma: first clinical evaluation in a US population. Mol Imaging Biol. 2016;18:924–934.
    OpenUrl
  32. 32.↵
    1. Pampliega O,
    2. Domercq M,
    3. Soria FN,
    4. Villoslada P,
    5. Rodríguez-Antigüedad A,
    6. Matute C
    . Increased expression of cystine/glutamate antiporter in multiple sclerosis. J Neuroinflammation. 2011;8:63.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Levring TB,
    2. Hansen AK,
    3. Nielsen BL,
    4. et al
    . Activated human CD4+ T cells express transporters for both cysteine and cystine. Sci Rep. 2012;2:266.
    OpenUrlCrossRefPubMed
  34. 34.↵
    1. Siska PJ,
    2. Kim B,
    3. Ji X,
    4. et al
    . Fluorescence-based measurement of cystine uptake through xCT shows requirement for ROS detoxification in activated lymphocytes. J Immunol Methods. 2016;438:51–58.
    OpenUrlCrossRef
  35. 35.↵
    1. Balkwill FR,
    2. Capasso M,
    3. Hagemann T
    . The tumor microenvironment at a glance. J Cell Sci. 2012;125:5591–5596.
    OpenUrl
  36. 36.↵
    1. Merckx E,
    2. Albertini G,
    3. Paterka M,
    4. et al
    . Absence of system xc− on immune cells invading the central nervous system alleviates experimental autoimmune encephalitis. J Neuroinflammation. 2017;14:9.
    OpenUrl
  • Received for publication January 7, 2019.
  • Accepted for publication May 28, 2019.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 60 (12)
Journal of Nuclear Medicine
Vol. 60, Issue 12
December 1, 2019
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Characterization of 18F-hGTS13 for Molecular Imaging of xC− Transporter Activity with PET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The Characterization of 18F-hGTS13 for Molecular Imaging of xC− Transporter Activity with PET
Corinne Beinat, Gayatri Gowrishankar, Bin Shen, Israt S. Alam, Elise Robinson, Tom Haywood, Chirag B. Patel, Emily Carmen Azevedo, Jessa B. Castillo, Ohad Ilovich, Norman Koglin, Heribert Schmitt-Willich, Mathias Berndt, Andre Mueller, Marion Zerna, Ananth Srinivasan, Sanjiv Sam Gambhir
Journal of Nuclear Medicine Dec 2019, 60 (12) 1812-1817; DOI: 10.2967/jnumed.119.225870

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Characterization of 18F-hGTS13 for Molecular Imaging of xC− Transporter Activity with PET
Corinne Beinat, Gayatri Gowrishankar, Bin Shen, Israt S. Alam, Elise Robinson, Tom Haywood, Chirag B. Patel, Emily Carmen Azevedo, Jessa B. Castillo, Ohad Ilovich, Norman Koglin, Heribert Schmitt-Willich, Mathias Berndt, Andre Mueller, Marion Zerna, Ananth Srinivasan, Sanjiv Sam Gambhir
Journal of Nuclear Medicine Dec 2019, 60 (12) 1812-1817; DOI: 10.2967/jnumed.119.225870
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • KEY POINTS
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Comparative Evaluation of [18F]5-Fluoroaminosuberic Acid and (4S)-4-3-[18F]fluoropropyl)-L-Glutamate as System Formula-Targeting Radiopharmaceuticals
  • Comparative Evaluation of [18F]5-Fluoroaminosuberic Acid and (4S)-4-3-[18F]fluoropropyl)-L-Glutamate as System Formula-Targeting Radiopharmaceuticals
  • Latest Advances in Imaging Oxidative Stress in Cancer
  • STING-driven interferon signaling triggers metabolic alterations in pancreas cancer cells visualized by [18F]FLT PET imaging
  • Clinical Evaluation of (4S)-4-(3-[18F]Fluoropropyl)-L-glutamate (18F-FSPG) for PET/CT Imaging in Patients with Newly Diagnosed and Recurrent Prostate Cancer
  • Google Scholar

More in this TOC Section

Molecular Imaging

  • Optical Navigation of the Drop-In γ-Probe as a Means to Strengthen the Connection Between Robot-Assisted and Radioguided Surgery
  • Molecular Imaging of Very Late Antigen-4 in Acute Lung Injury
  • Preclinical Evaluation of an Engineered Single-Chain Fragment Variable-Fragment Crystallizable Targeting Human CD44
Show more Molecular Imaging

Basic

  • Optical Navigation of the Drop-In γ-Probe as a Means to Strengthen the Connection Between Robot-Assisted and Radioguided Surgery
  • Molecular Imaging of Very Late Antigen-4 in Acute Lung Injury
  • Preclinical Evaluation of an Engineered Single-Chain Fragment Variable-Fragment Crystallizable Targeting Human CD44
Show more Basic

Similar Articles

Keywords

  • xC− transporter
  • oxidative stress
  • cancer metabolism
  • PET imaging
  • 18F-hGTS13
SNMMI

© 2025 SNMMI

Powered by HighWire