Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Relative Difference Prior with Dynamic Edge Preservation Parameter

Andriy Andreyev, Chuanyong Bai and Zhiqiang Hu
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 744;
Andriy Andreyev
1Philips Healthcare Highland Heights OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chuanyong Bai
3Philips Healthcare Cleveland, OH Solon OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zhiqiang Hu
2Philips Healthcare Cleveland Highland Heights OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

744

Objectives: Effective noise control in the iterative reconstruction is challenging due to the statistical nature of emission tomography. Regularization by using edge preserving priors such as Relative Difference Prior (RDP) has been successful in reducing the noise in the image while preserving the contrast. The task of setting optimal parameters for such priors is still challenging. Often, even for hand-optimized parameters, there is still a risk that certain noise fluctuations may get past the edge preservation threshold, get amplified during the iterative reconstruction and appear as “real” features (hot-spots) in the final image. Since the common property of the typical iterative image reconstruction algorithm (e.g., OSEM) is that noise is amplified towards later iterations, we propose to use regularized reconstruction with dynamically adjustable, iteration-dependent edge preservation parameter (such as the gamma parameter in RDP). We investigated the performance of the proposed approach using RDP for real PET data.

Methods: We utilize the following feature of the iterative reconstructions. During the iterations of OSEM, large components (lower frequency) of the image converge faster. At later iterations, the high-frequency components increase which most likely represent the noisy component of the image. The main idea of this work is to allow stronger edge preservation in earlier iterations (lower penalty to allow for unrestricted recovery of real features before the noise starts to build up). As the regularized reconstruction goes towards later iterations to pursue convergence, the edge preservation parameter is relaxed (leading to gradual increase of the penalty) to prevent the noise amplification and ensure convergence. We compared the performance of the proposed method to the standard RDP with fixed parameters optimized either for improved contrast or maximum noise and hot-spot removal. We used NEMA IQ phantom data to test the proposed method.

Results: In one particular reconstruction using NEMA IQ phantom data, with a standard RDP penalty with settings (i.e., gamma=1.0) optimized for contrast preservation, in one of the slices there is a hot-spot artifact. This hot spot is easily removed when the contrast preservation threshold gamma is set lower (gamma=0.5) but at the cost of greatly diminished contrast for the 10 mm sphere. Whereas, the combination of RDP with dynamic edge preservation parameter (starting initially from a high gamma value of 1.5 and gradually reduced to 0.5 over the course of 20 iterations) allows the reconstruction to both suppress hot-spot development and to preserve the majority of contrast in the 10 mm sphere.

Conclusion: The proposed RDP reconstruction with dynamically changing iteration-dependent parameter demonstrated the improvement in noise-contrast tradeoff over the standard OSEM. The approach demonstrates the benefit of reduced chance for artificial hot-spots with similar edge-preservation potential compared to RDP with fixed parameters. Research Support: This work is supported by Philips.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 58, Issue supplement 1
May 1, 2017
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Relative Difference Prior with Dynamic Edge Preservation Parameter
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Relative Difference Prior with Dynamic Edge Preservation Parameter
Andriy Andreyev, Chuanyong Bai, Zhiqiang Hu
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 744;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Relative Difference Prior with Dynamic Edge Preservation Parameter
Andriy Andreyev, Chuanyong Bai, Zhiqiang Hu
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 744;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

Quantitation Topics in PET and SPECT

  • Complementary frame reconstruction improves measurement of cerebral perfusion from dynamic PET O-15 labelled water images
  • Y-90 SPECT maximum likelihood image reconstruction with a new model for tissue-dependent bremsstrahlung production