Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleCLINICAL INVESTIGATIONS

Optimal Metabolite Curve Fitting for Kinetic Modeling of 11C-WAY-100635

Songmei Wu, R. Todd Ogden, J. John Mann and Ramin V. Parsey
Journal of Nuclear Medicine June 2007, 48 (6) 926-931; DOI: https://doi.org/10.2967/jnumed.106.038075
Songmei Wu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Todd Ogden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. John Mann
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ramin V. Parsey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Many quantitative imaging protocols that make use of a metabolite-corrected arterial input function require the use of a mathematic model to describe the rate of metabolism of the radioligand. Commonly, parametric models are fit to metabolism data and then the fitted model is used to correct the plasma input function. 11C-WAY 100635 is a rapidly metabolized radioligand used extensively in mapping the 5-hydroxytryptamine receptor 1A system. Methods: To evaluate the adequacy of fit of 4 metabolite models, we examined data from 92 subjects who received an injection of 11C-WAY 100635, were imaged with PET, and underwent measurement of total plasma concentration and metabolites. The performance of these models was assessed according to residual plots, as well as fit and information criteria. Results: The study showed that the choice of model has a substantial effect on the resulting estimates of outcome measures. Conclusion: Among the models considered, the Hill model provides the best fit across all criteria.

  • nonlinear modeling
  • residual analysis
  • kinetic modeling

The radioligand 11C-WAY-100635 is used extensively in imaging the 5-hydroxytryptamine receptor 1A system (1–5). In such studies, the method for estimation of binding potential (maximum number of binding sites divided by dissociation constant) that involves the fewest assumptions requires determination of the metabolite-corrected arterial input function. Typically, total radioactivity counts in the plasma are corrected for the rate of metabolism of the injected “parent” (unmetabolized radiotracer). In the case of the PET ligand 11C-WAY-100635, metabolism is rapid, with nearly 80% of the parent compound being metabolized within 5–15 min.

For accurate quantification of the binding potential, we have shown that a minimum of 110 min of emission scanning are required (6). Metabolites cannot be determined reliably at late times because of low levels of parent compound; low counting rates decrease confidence in count estimates; and 11C decays relatively quickly: For these reasons, the metabolite curve is typically fit by a parametric model and extrapolated to late times according to the fitted model.

Models that have been used for this purpose include 1-exponential (6), 2-exponential with 1 time constant constrained (7), 3-exponential (8,9), multiexponential (10,11), and a Hill function (12,13).

We examined 4 candidate models for the rate of metabolism of the parent compound in plasma over time. Model fit was assessed using residual sum of squares, Akaike information criterion (AIC) (14), and residual plots.

MATERIALS AND METHODS

Data Description

We considered data from 92 subjects recruited in an ongoing neuroreceptor imaging study. Imaging and measurement of metabolites were performed as described previously (6). Briefly, after acetonitrile extraction of the plasma, samples were separated into parent and 1 polar metabolite peak by high-pressure liquid chromatography on 5 samples. Extraction was measured at every time point and did not vary with time. The rate of metabolism is presented as a ratio of the area under the curve of the unmetabolized compound peak divided by the total unmetabolized and metabolized peak. In other words, the fraction of unmetabolized compound isMathwhere vi is the radioactivity count, corrected for background and decay, under peak i. The metabolites are eluted from the column first and collected in tubes (fractions) numbered 1 through 3. The parent is eluted later, with no overlap between the parent and metabolite, and collected in fractions 4 and 5. The fractions are then counted in the well counter, and the percentage of unmetabolized compound is calculated as above.

Modeling Metabolite Data

We considered 2 types of models. One approach is to model the proportion of unmetabolized parent ligand. An alternative is to model the concentration of the parent compound directly with a physiologic model of metabolism. At time t, we used Cp(t) and Cmet(t) to denote the concentrations of parent compound and metabolite, respectively. Total concentration is given by Math. Thus, “proportion models” are fit to describe the fraction Math; the kinetic modeling alternative is to fit the Math measurements directly.

Proportion Models.

Observed fractions Math taken at corresponding time points are modeled as Math, where Math represents the noise. Proportion models are constrained in 3 ways. Specifically, because the compound is injected at time zero, it is assumed that the compound is not metabolized and hence Math (the first constraint). After that, the compound is continuously metabolized (the second constraint), and its metabolism is irreversible (the third constraint).

The first proportion model considered is the 1-exponential model:MathEq. 1The restrictions are satisfied provided that Math and Math.

Another common model is the 2-exponential model:MathEq. 2We arbitrarily let Math represent the larger of the 2 time constants (i.e., Math). Restrictions on this model are satisfied if Math.

The third model for metabolite fraction considered is the Hill model (15):MathEq. 3for which we require Math, Math, and Math.

A Kinetic Model.

Knowledge of the kinetics of the metabolism process may improve our ability to model the data. To our knowledge, no published paper using WAY100635 has applied a kinetic model to fit the metabolite function, but it seems important to consider at least 1 kinetic model for comparison's sake. We considered a basic 2-compartment kinetic model that allows for 1 metabolite as diagrammed in Figure 1. Though alternative kinetic models could be fit, model complexity is limited by the small number of data points per subject.

FIGURE 1. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1. 

Diagram of kinetic model. Parent compound begins in plasma and passes to tissue compartment (thought to be composed primarily of liver but could also include kidneys and other tissues). Some compound is metabolized and moves to “met” compartment; rest is excreted back to blood without being metabolized. Rate parameters k1– k4 are assumed to be nonnegative.

The total concentration of radioactivity in the plasma is measured over time through plasma analysis. The concentration of metabolite Math is measured through metabolite analysis, but Math cannot be observed directly. In our study, the metabolite data consist of the fraction of unmetabolized compound at Math specific time points (Math), and the plasma data consists of Math time points and corresponding total concentrations of radioactive substances (i.e., Math).

The system of differential equations corresponding to Figure 1 in terms of rate parameters isMathMathThe solution for Math is given byMathEq. 4where ⊗ denotes convolution.

The total concentration Math in Equation 4 was estimated from a plasma data model. Our plasma model comprised 2 pieces: After the injection, the concentration of the compound in plasma increased linearly for a short time to its peak value; after peaking, the concentration fell off according to a sum-of-exponentials model (6). The linear rise in the plasma function until the peak was a fairly crude representation of the true plasma concentration curve, but because this interval was small relative to total scanning time (about 1%), it makes little difference in the resulting model estimates. Once the total plasma data are fit to this model, the estimated plasma concentration function is plugged in for estimating Math.

Weighting.

The data used for the fitting are computed as ratios of radioactive counts in each fraction. In general, the fraction of unmetabolized (parent) compound is computed for a given time asMathwhere I represents an index set. For our data, indices range from 1 to 5 and I = {4, 5}.

The γ-counter (1480 Wizard 3M Automatic γ-Counter; Wallac) provides both the Math values and an estimate of their SD. Using these quantities, estimates of the SD of the fractions can be computed using the so-called delta method. If each Math denotes the SD of the corresponding Math measurement and the Math's are taken to be independent, then the variance of Y is approximated according toMathEq. 5This is used to determine the weights used in model fitting.

Model-Fitting Algorithm.

Standard iterative nonlinear regression methods are used for the model fitting:MathEq. 6where β is the vector of the parameters in the models and Math is computed as Math according to Equation 5.

RESULTS

Visual Analysis of Model Fits

Figure 2 gives example fits for each model for a specific dataset. For the kinetic model, to equalize the model-fitting procedure (to allow a more direct comparison), we computed the corresponding fraction Math byMathwhere Math comes from Equation 4 and then is fit using Equation 6. Though the fitting is done using the fractional data, results are displayed using metabolite concentration data. The 2-exponential model clearly undershoots the later time points, because the 2-exponential model does not contain a constant term and is thus constrained to go to zero rapidly, even when the data do not justify this (as in this example). The data were also fit with a 2-exponential model with constant (results not shown), but the fitting procedure was rather unstable (many parameters with few data points) and for almost all subjects, one of the exponential terms had a zero coefficient, providing no improvement over the 1-exponential model.

FIGURE 2. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2. 

Fitted data for all models for 1 subject's data. Plots show fitted unmetabolized fraction vs. observed data.

Comparisons Based on Fit Diagnostics

We also compared weighted residual sum of squares and AIC for each model across all datasets. AIC (14) attempts a compromise between model fit and parsimony by imposing a penalty for additional model parameters. For normally distributed errors, the criterion is AIC = nlog(weighted residual sum of squares/n) + 2M, where n is the number of data points and M is the number of model parameters.

Figure 3 shows box plots for AIC values corresponding to each candidate model; corresponding box plots for log(weighted residual sum of squares) are similar and not shown. On the basis of these measures, the Hill model fits the data best among the models considered.

FIGURE 3. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3. 

Box plots of AIC values for 1-exponential, 2-exponential, Hill, and kinetic models. One- and 2-exponential models have similar results, and kinetic model has smaller values than exponential models. Compared with the others, Hill model tends to have much smaller values: Maximum AIC value is less than median for kinetic model and less than 25th percentile for other models. exp = exponential.

Residual Analysis

If the model fits well, at least in large datasets, residuals for each dataset should have an approximate normal distribution with a mean of zero. We had no more than 6 observations in each dataset and thus could not expect residuals to have a distribution close to normality. However, for an appropriate choice of model, we would expect residuals to be centered on zero and to be nearly symmetric.

In a typical regression analysis, many observations are pooled to fit a model and all residuals are plotted together in a single plot. In our present study, data from each subject were fitted separately. In such a situation, we search for patterns among independent residuals by pooling across all subjects separately for each time point.

All residuals from all 92 subjects are displayed simultaneously in Figure 4. On the basis of both absolute size of residuals and distribution of residuals about zero, the Hill model would be preferred.

FIGURE 4. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4. 

Graph of weighted residual for each model. For better visual display, points are spread out by adding small amount of gaussian noise in x direction. For 1- and 2-exponential models, residuals tend to fall only on one side of zero at each time point. Means of residuals are relatively far from zero, and distributions of residuals are, in general, rather asymmetric and heavily skewed. For kinetic model, similar problems exist. Residuals for Hill model look more reasonable: They are evenly scattered around zero, and their distributions are fairly symmetric. Although, at first 2 time points, residuals are skewed to one side of zero, they are all quite small relative to those of other models.

Effect on Kinetic Outcome Measures

A crucial question about metabolite modeling is whether the choice of model makes a difference for subsequent region-of-interest or voxel-level analysis. Therefore, we compared the resulting biologic parameters binding potential (BP1) and volume of distribution (VT) that resulted from different metabolite models.

For each candidate model, the resulting estimated metabolite-corrected plasma concentration curve was used as the input function for subsequent kinetic modeling of PET data. This procedure was applied to all 87 complete datasets to estimate total equilibrium VT (using a 1-tissue kinetic model) for cerebellum, and BP1 (using a 2-tissue constrained model) (6) for 4 regions: amygdala, hippocampus, cingulate, and parietal lobe.

The effect of the metabolite modeling is summarized in Table 1. To test for significance of the differences, paired t tests and Wilcoxon signed-rank tests were applied. Results are given in Table 2. All P values are small, indicating that the choice of metabolite model had a highly significant impact on resulting outcome measures derived from the imaging data.

View this table:
  • View inline
  • View popup
TABLE 1

BP1 Measurements Using Each of the 4 Candidate Models on 4 Brain Regions, Along with VT Estimates for Cerebellum

View this table:
  • View inline
  • View popup
TABLE 2

Paired t Tests and Signed-Rank Tests for Testing Difference Between BP1 and VT Estimates from Different Models

DISCUSSION

Having an arterial input function for modeling of dynamic PET data can be a great help, provided that the input function is measured and modeled appropriately. Key to the validity of the input function is correctly accounting for the metabolism process of the ligand. Thus, it is of vital importance to ensure that the model used to describe metabolism is adequate.

We considered only 1 kinetic model, though others are possible. Huang et al. (16) presented the kinetic model building procedure and model formulas for the general case, including the case of multiple metabolites. Andree et al. (17) showed that WAY100635 has more than 1 metabolite in humans. However, they also pointed out that only 1 metabolite (11C-desmethyl-WAY-100635) can be used as a radioligand for central 5-hydroxytryptamine receptor 1A; other metabolites are more polar and not likely to pass the blood–brain barrier. Osman et al. (18) observed another significant polar metabolite in some experiments—11C-cyclohexanecarboxylic acid—along with some other metabolites that were more polar still. Thus, with the exception of 11C-desmethyl-WAY-100635, no metabolites are expected to bind strongly to 5-hydroxytryptamine receptor 1A. Even if the radioactive acid metabolite binds nonspecifically, it is in low levels and cleared rapidly (in about 5 min). On the basis of these considerations, as well as the obvious limitation on the complexity of models that can be fit with 6 data points, we concluded that the kinetic model considered in the data would be an appropriate candidate for these data.

CONCLUSION

Among those considered, the Hill function was the model of choice to describe the metabolism of 11C-WAY-100635, and the impact of model choice was confirmed by the analysis on BP1 and VT data, demonstrating the need to carefully select an appropriate metabolite model in analyzing PET data.

Acknowledgments

This work was supported in part by MH62185 and NARSAD.

Footnotes

  • COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Fisher PM, Meltzer CC, Ziolko SK, Price JC, Hariri AR. Capacity for 5-HT(1A)-mediated autoregulation predicts amygdala reactivity. Nat Neurosci. 2006;9:1362–1363.
    OpenUrlCrossRefPubMed
  2. 2.
    Parsey RV, Olvet DM, Oquendo MA, Huang YY, Ogden RT, Mann JJ. Higher 5-HT1A receptor binding potential during a major depressive episode predicts poor treatment response: preliminary data from a naturalistic study. Neuropsychopharmacology. 2006;31:1745–1749.
    OpenUrlCrossRefPubMed
  3. 3.
    Parsey RV, Oquendo MA, Ogden RT, et al. Altered serotonin 1A binding in major depression: a [carbonyl-C-11]WAY100635 positron emission tomography study. Biol Psychiatry. 2006;59:106–113.
    OpenUrlCrossRefPubMed
  4. 4.
    Borg J, Andree B, Lundberg J, Halldin C, Farde L. Search for correlations between serotonin 5-HT1A receptor expression and cognitive functions: a strategy in translational psychopharmacology. Psychopharmacology (Berl). 2006;185:389–394.
    OpenUrlCrossRefPubMed
  5. 5.↵
    Bailer UF, Frank GK, Henry SE, et al. Altered brain serotonin 5-HT1A receptor binding after recovery from anorexia nervosa measured by positron emission tomography and [carbonyl11C]WAY-100635. Arch Gen Psychiatry. 2005;62:1032–1041.
    OpenUrlCrossRefPubMed
  6. 6.↵
    Parsey RV, Slifstein M, Hwang D-R, et al. Validation and reproducibility of measurement of 5-HT1A receptor parameters with [carbonyl-11C]WAY-100635 in humans: comparison of arterial and reference tissue input functions. J Cereb Blood Flow Metab. 2000;20:1111–1133.
    OpenUrlCrossRefPubMed
  7. 7.↵
    Abi-Dargham A, Simpson N, Kegeles L, et al. PET studies of binding competition between endogenous dopamine and the D1 radiotracer [11C]NNC 756. Synapse. 1999;32:93–109.
    OpenUrlCrossRefPubMed
  8. 8.↵
    Roivainen A, Forsback S, Gronroos T, et al. Blood metabolism of [methyl-11C]choline: implications for in vivo imaging with positron emission tomography. Eur J Nucl Med. 2000;27:25–32.
    OpenUrlCrossRefPubMed
  9. 9.↵
    Acton PD, Choi SR, Hou C, Plossl K, Kung HF. Quantification of serotonin transporters in nonhuman primates using [123I]ADAM and SPECT. J Nucl Med. 2001;42:1556–1562.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    Hume SP, Ashworth S, Opacka-Juffry J, et al. Evaluation of [O-methyl-3H]WAY-100635 as an in vivo radioligand for 5-HT1A receptors in rat brain. Eur J Pharmacol. 1994;271:515–523.
    OpenUrlCrossRefPubMed
  11. 11.↵
    Carson RE, Wu Y, Lang L, et al. Brain uptake of the acid metabolites of F-18-labeled WAY 100635 analogs. J Cereb Blood Flow Metab. 2003;23:249–260.
    OpenUrlPubMed
  12. 12.↵
    Gunn RN, Sargent PA, Bench CJ, et al. Tracer kinetic modeling of the 5-HT1A receptor ligand [carbonyl-11C]WAY-100635 for PET. Neuroimage. 1998;8:426–440.
    OpenUrlCrossRefPubMed
  13. 13.↵
    Oikonen V, Allonen T, Nagren K, Kajander J, Hietala J. Quantification of [carbonyl-(11)C]WAY-100635 binding: considerations on the cerebellum. Nucl Med Biol. 2000;27:483–486.
    OpenUrlCrossRefPubMed
  14. 14.↵
    Akaike H. Information theory and an extension of the maximum likelihood principle. In: Petrov BN, Csaki F, eds. Proceedings of the 2nd International Symposium on Information Theory. Budapest, Hungary: Akademiai Kiado; 1973:267–281.
    OpenUrl
  15. 15.↵
    Hill AV. The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves. J Physiol (Lond). 1910;40:4–7.
    OpenUrl
  16. 16.↵
    Huang SC, Barrio JR, Yu DC, et al. Modelling approach for separating blood time-activity curves in positron emission tomographic studies. Phys Med Biol. 1991;36:749–761.
    OpenUrlCrossRefPubMed
  17. 17.↵
    Andree B, Halldin C, Thorberg SO, Sandell J, Farde L. Use of PET and the radioligand [carbonyl-11C]WAY-100635 in psychotropic drug development. Nucl Med Biol. 2000;27:515–521.
    OpenUrlCrossRefPubMed
  18. 18.↵
    Osman S, Lundkvist C, Pike VW, et al. Characterisation of the appearance of radioactive metabolites in monkey and human plasma from the 5-H T 1A receptor radioligand, [carbonyl-11C]WAY-100635: explanation of high signal contrast in PET and an aid to biomathematical modelling. Nucl Med Biol. 1998;25:215–223.
    OpenUrlCrossRefPubMed
  • Received for publication November 14, 2006.
  • Accepted for publication March 16, 2007.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 48 (6)
Journal of Nuclear Medicine
Vol. 48, Issue 6
June 2007
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Optimal Metabolite Curve Fitting for Kinetic Modeling of 11C-WAY-100635
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Optimal Metabolite Curve Fitting for Kinetic Modeling of 11C-WAY-100635
Songmei Wu, R. Todd Ogden, J. John Mann, Ramin V. Parsey
Journal of Nuclear Medicine Jun 2007, 48 (6) 926-931; DOI: 10.2967/jnumed.106.038075

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Optimal Metabolite Curve Fitting for Kinetic Modeling of 11C-WAY-100635
Songmei Wu, R. Todd Ogden, J. John Mann, Ramin V. Parsey
Journal of Nuclear Medicine Jun 2007, 48 (6) 926-931; DOI: 10.2967/jnumed.106.038075
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Modeling Strategies for Quantification of In Vivo 18F-AV-1451 Binding in Patients with Tau Pathology
  • Quantification of 11C-Laniquidar Kinetics in the Brain
  • In Hot Blood: Quantifying the Arterial Input Function
  • Modeling Considerations for 11C-CUMI-101, an Agonist Radiotracer for Imaging Serotonin 1A Receptor In Vivo with PET
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire