Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherBASIC SCIENCE INVESTIGATIONS

Dosimetric Techniques in 90Y-Microsphere Therapy of Liver Cancer: The MIRD Equations for Dose Calculations

Seza A. Gulec, Geraldine Mesoloras and Michael Stabin
Journal of Nuclear Medicine July 2006, 47 (7) 1209-1211;
Seza A. Gulec
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Geraldine Mesoloras
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Stabin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Therapy with 90Y-microspheres is emerging as a mainstream treatment modality in the management of patients with primary and metastatic liver cancer (1,2). The technique involves the administration of 90Y-microspheres into the hepatic artery, which is accessed via the transfemoral route or through a hepatic arterial infusion port or pump. The technique was first introduced by Ariel, who also reported the first series of successful treatment in patients with metastatic colorectal cancer (3,4). The patients were treated with intraarterial chemotherapy and 3.7–5.5 GBq (100–150 mCi) of 90Y-resin microspheres. The estimated radiation dose to the liver from 3.7 GBq (100 mCi) of 90Y-microspheres was 120–180 Gy using the MIRD approach. It took a few decades since Ariel's early experience, in the 1960s, to refine the manufacturing technology and administration techniques of 90Y-microspheres before more structured studies could be implemented (5–7). The initial indications, for use in colorectal cancer metastases and hepatocellular carcinoma, have now expanded to include other unresectable metastatic liver tumors (8,9). The development of highly sophisticated techniques of administration has improved the therapeutic efficacy while minimizing the attendant side effects (10).

Compared with the growing clinical experience with 90Y-microsphere therapy, dosimetric data are unsatisfactory largely because of the lack of uniform and well-explained methods. This brief report aims to summarize the principles of 90Y-microsphere dosimetry and provide the mathematic derivations of the equations used in the MIRD schema.

Commercially available 90Y-microsphere products include resin microspheres with a specific activity of 40–70 Bq per sphere (SIR-Spheres; Sirtex Medical) and glass microspheres with a specific activity of 2,400–2,700 Bq per sphere (TheraSphere; MDS Nordion), both of which have median diameters of between 35 and 40 μm. Microspheres administered in the hepatic artery are distributed preferentially in the tumor compartment and are trapped within the microvasculature of the tumor. Microspheres are biocompatible but not biodegradable, and therefore no biologic elimination occurs. The entire 90Y dose is delivered over a physical decay period with a half-life of 2.66 d. Radiation delivery from 90Y-microspheres is essentially confined to the liver because of the 3.8-mm mean range and approximately 10-mm maximum range of β-particles in soft tissue.

Although, in reality, 90Y-microsphere distribution is never uniform and, in fact, is invariably patchy, with a wide range of variation, MIRD dose estimations are based on the assumption of a uniform distribution. Obviously, this assumption of uniform distribution of the microspheres is acceptable only as a first-order approximation. Despite this recognized limitation, the MIRD methodology provides consistent and reproducible dose estimates.

The MIRD Schema for 90Y-Microspheres

90Y-Microspheres are distributed in the liver parenchyma with a concentration of C μCi/g. Because 1 μCi produces 3.7 × 104 disintegrations per second, energy released and absorbed per gram of tissue in 1 s is 3.7 × 104 Ēβ MeV, where Ēβ is the average β-particle energy per disintegration, in mega–electron volts. The average β-particle energy per disintegration for 90Y is 0.93 MeV. One rad is defined as 100 erg/g of tissue. It is equivalent to the absorption of 6.24 × 107 MeV/g:MathEq. 1where dis = disintegration.

The average half-life is used to determine the total dose received during treatment and is equal to the half-life multiplied by 1.44. The half-life for 90Y is 2.66 d. Therefore, the total dose for complete decay of 90Y isMathEq. 2

The administered 90Y-microsphere activity is distributed in tumor and normal liver compartments. The distribution profile is determined by the relative vascularity and volume of these 2 compartments and is expressed as the tumor-to-liver ratio (TLR). When lung shunting due to intrahepatic peritumoral arteriovenous communications occurs, a third compartment (lung) is encountered and is expressed as the lung shunt fraction (SF). The TLR and SF can be determined using 99mTc-macroaggregated albumin scans. Region-of-interest analysis of tumor and normal liver compartments on SPECT images is used to determine the TLR. The SF is calculated on planar images using the formula below:MathEq. 3

It is assumed that the administered activity is distributed evenly within the normal liver and tumor compartments. The tumor compartment, as expected, receives a higher concentration proportional to the TLR. Using the tumor and liver masses, the dose fraction accumulated in the normal liver (fractional liver uptake) isMathEq. 4

Activity to be administered for a desired liver dose can be calculated fromMathEq. 5

Dose delivered from a given administered activity isMathEq. 6

The fraction of the administered activity accumulated in the tumor (fractional tumor uptake) isMathEq. 7

The dose to the tumor and the lungs can be determined using the following equations:MathEq. 8MathEq. 9

Mass is assumed to be equal to volume for tumor and liver tissues, because their densities are close to that of soft tissue (1.04 g/cm3). Therefore, for simplicity, “mass” can be replaced with “volume” in equations for liver and tumor dose determination. The density of lung, however, is approximately 0.30 g/cm3. Therefore, measured lung volumes on CT images need to be multiplied by this factor to obtain the mass. A lung mass of 1,000 g based on the anthropomorphic phantom design applied in MIRD modeling can be used if CT calculation is not available.

Concluding Notes

The MIRD schema and its applications for radiopharmaceuticals labeled with other pure-β-emitting radionuclides using bremsstrahlung imaging and quantitation have been reported (11,12). This technical review has focused on 90Y-microsphere dose determination based on 99mTc-macroaggregated albumin image quantitation. The 99mTc-macroaggregated albumin administration and acquisition protocols and processing techniques are important and are the subject of a separate technical report. We believe that the application of the MIRD schema to 90Y-microsphere treatment of primary and metastatic liver tumors offers better guidance than does empiric approaches. The development of more accurate absorbed dose estimates and the correlation of these estimates with biologic response will lead to a better understanding of the results of treatment and improve the clinical outcomes.

Footnotes

  • COPYRIGHT © 2006 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Murthy R, Xiong H, Nunez R, et al. Yttrium 90 resin microspheres for the treatment of unresectable colorectal hepatic metastases after failure of multiple chemotherapy regimens: preliminary results. J Vasc Interv Radiol. 2005;16:937–945.
    OpenUrlPubMed
  2. 2.↵
    Lau WY, Ho SK, Yu SC, Lai EC, Liew CT, Leung TW. Salvage surgery following downstaging of unresectable hepatocellular carcinoma. Ann Surg. 2004;240:299–305.
    OpenUrlCrossRefPubMed
  3. 3.↵
    Ariel IM, Padula G. Treatment of symptomatic metastatic cancer to the liver from primary colon and rectal cancer by the intra-arterial administration of chemotherapy and radioactive isotopes. J Surg Oncol. 1978;10:327–336.
    OpenUrlCrossRefPubMed
  4. 4.↵
    Ariel IM, Padula G. Treatment of asymptomatic metastatic cancer to the liver from primary colon and rectal cancer by the intra-arterial administration of chemotherapy and radioactive isotopes. J Surg Oncol. 1982;20:151–156.
    OpenUrlCrossRefPubMed
  5. 5.↵
    Van Hazel G, Blackwell A, Anderson J, et al. Randomised phase 2 trial of SIR-Spheres plus fluorouracil/leucovorin chemotherapy versus fluorouracil/leucovorin chemotherapy alone in advanced colorectal cancer. J Surg Oncol. 2004;88:78–85.
    OpenUrlCrossRefPubMed
  6. 6.
    Gray B, Van Hazel G, Hope M, et al. Randomised trial of SIR-Spheres plus chemotherapy vs. chemotherapy alone for treating patients with liver metastases from primary large bowel cancer. Ann Oncol. 2001;12:1711–1720.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    Lau WY, Leung WT, Ho S, et al. Treatment of inoperable hepatocellular carcinoma with intrahepatic yttrium-90 microspheres: a phase I and II study. Br J Cancer. 1994;70:994–999.
    OpenUrlPubMed
  8. 8.↵
    Rubin D, Nutting C, Jones B. Metastatic breast cancer in a 54-year-old woman: integrative treatment with yttrium-90 radioembolization. Integr Cancer Ther. 2004;3:262–267.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    King J, Morris D, Glenn D, et al. SIR-Spheres for liver metastases from neuroendocrine tumors. In: Abstracts of the 2005 WCGIC (9th World Congress on Gastrointestinal Cancer); Barcelona, Spain. Abstract P-090.
  10. 10.↵
    Liu D, Salem R, Bui J, et al. Angiographic considerations in patients undergoing liver-directed therapy. J Vasc Interv Radiol. 2005;16:911–935.
    OpenUrlPubMed
  11. 11.↵
    Siegel JA, Handy DM, Kopher KA, et al. Therapeutic beta irradiating isotopes in bony metastasis: a technique for bremsstrahlung imaging and quantitation. Antibody Immunoconjugates Radiopharm. 1992;5:237–248.
  12. 12.↵
    Siegel JA, Zeiger LS, Order SE, Wallner PE. Quantitative bremsstrahlung single photon emission computed tomographic imaging: use for volume, activity, and absorbed dose calculations. Int J Radiat Oncol Biol Phys. 1995;31:953–958.
    OpenUrlCrossRefPubMed
  • Received for publication November 30, 2005.
  • Accepted for publication March 13, 2006.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 47 (7)
Journal of Nuclear Medicine
Vol. 47, Issue 7
July 2006
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Dosimetric Techniques in 90Y-Microsphere Therapy of Liver Cancer: The MIRD Equations for Dose Calculations
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Dosimetric Techniques in 90Y-Microsphere Therapy of Liver Cancer: The MIRD Equations for Dose Calculations
Seza A. Gulec, Geraldine Mesoloras, Michael Stabin
Journal of Nuclear Medicine Jul 2006, 47 (7) 1209-1211;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Dosimetric Techniques in 90Y-Microsphere Therapy of Liver Cancer: The MIRD Equations for Dose Calculations
Seza A. Gulec, Geraldine Mesoloras, Michael Stabin
Journal of Nuclear Medicine Jul 2006, 47 (7) 1209-1211;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Footnotes
    • References
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Treatment of Primary Liver Tumors and Liver Metastases, Part 1: Nuclear Medicine Techniques
  • A Prospective Study of Quantitative SPECT/CT for Evaluation of Lung Shunt Fraction Before SIRT of Liver Tumors
  • How Sensitive Is the Upper Gastrointestinal Tract to 90Y Radioembolization? A Histologic and Dosimetric Analysis in a Porcine Model
  • The Impact of Image Reconstruction Bias on PET/CT 90Y Dosimetry After Radioembolization
  • Three-Dimensional Personalized Monte Carlo Dosimetry in 90Y Resin Microspheres Therapy of Hepatic Metastases: Nontumoral Liver and Lungs Radiation Protection Considerations and Treatment Planning Optimization
  • Prognostic Utility of 90Y Radioembolization Dosimetry Based on Fusion 99mTc-Macroaggregated Albumin-99mTc-Sulfur Colloid SPECT
  • 99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization
  • Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization
  • Radiodosimetric Estimates for Radioembolic Therapy of Liver Tumors: Challenges and Opportunities
  • Clinical Feasibility of Fast 3-Dimensional Dosimetry of the Liver for Treatment Planning of Hepatocellular Carcinoma with 90Y-Microspheres
  • Hepatic Structural Dosimetry in 90Y Microsphere Treatment: A Monte Carlo Modeling Approach Based on Lobular Microanatomy
  • Google Scholar

More in this TOC Section

  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis
  • Counting Rate Characteristics and Image Distortion in Preclinical PET Imaging During Radiopharmaceutical Therapy
  • Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology
Show more Basic Science Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire