Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method

Hyun Joon An, Seongho Seo, Hyejin Kang, Hongyoon Choi, Gi Jeong Cheon, Han-Joon Kim, Dong Soo Lee, In Chan Song, Yu Kyeong Kim and Jae Sung Lee
Journal of Nuclear Medicine April 2016, 57 (4) 587-593; DOI: https://doi.org/10.2967/jnumed.115.163550
Hyun Joon An
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
2Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Seongho Seo
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
3Department of Brain and Cognitive Sciences, Seoul National University College of Natural Sciences, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hyejin Kang
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hongyoon Choi
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gi Jeong Cheon
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
4Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Han-Joon Kim
5Department of Neurology, Seoul National University College of Natural Sciences, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dong Soo Lee
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
4Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea
6Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Suwon, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
In Chan Song
7Department of Radiology, Seoul National University College of Medicine, Seoul, Korea; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yu Kyeong Kim
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
8Department of Nuclear Medicine, Seoul Metropolitan Government Boramae Medical Center, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jae Sung Lee
1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, Korea
2Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea
3Department of Brain and Cognitive Sciences, Seoul National University College of Natural Sciences, Seoul, Korea
4Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Inaccuracy in MR image–based attenuation correction (MR-AC) leads to errors in quantification and the misinterpretation of lesions in brain PET/MRI studies. To resolve this problem, we proposed an improved ultrashort echo time MR-AC method that was based on a multiphase level-set algorithm with main magnetic field (B0) inhomogeneity correction. We also assessed the feasibility of this level-set–based MR-AC method (MR-AClevel), compared with CT-AC and MR-AC provided by the manufacturer of the PET/MRI scanner (MR-ACmMR). Methods: Ten healthy volunteers and 20 Parkinson disease patients underwent 18F-FDG and 18F-fluorinated-N-3-fluoropropyl-2-β-carboxymethoxy-3-β-(4-iodophenyl)nortropane (18F-FP-CIT) PET scans, respectively, using both PET/MRI and PET/CT scanners. The level-set–based segmentation algorithm automatically delimited air, bone, and soft tissue from the ultrashort echo time MR images. For the comparison, MR-AC maps were coregistered to reference CT. PET sinogram data obtained from PET/CT studies were then reconstructed using the CT-AC, MR-ACmMR, and MR-AClevel maps. The accuracies of SUV, SUVr (SUV and its ratio to the cerebellum), and specific–to–nonspecific binding ratios obtained using MR-AClevel and MR-ACmMR were compared with CT-AC using region-of-interest– and voxel-based analyses. Results: There was remarkable improvement in the segmentation of air cavities and bones and the quantitative accuracy of PET measurement using the level set. Although the striatal and cerebellar activities in 18F-FP-CIT PET and frontal activity in 18F-FDG PET were significantly underestimated by the MR-ACmMR, the MR-AClevel provided PET images almost equivalent to the CT-AC images. PET quantification error was reduced by a factor of 3 using MR-AClevel (SUV error < 10% in MR-AClevel and < 30% in MR-ACmMR [version VB18P], and < 5% in MR-AClevel and < 15% in MR-ACmMR [VB20P]). Conclusion: The results of this study indicate that our new multiphase level-set–based MR-AC method improves the quantitative accuracy of brain PET in PET/MRI studies.

  • PET/MRI
  • attenuation correction
  • level-set segmentation
  • brain PET

The development of tomographic imaging technologies has made dramatic progress in recent decades. Among the modern medical imaging systems, PET and MRI have greatly contributed to understanding normal and abnormal brain functions and evaluating various neurologic disorders (1–4). Although PET is the most sensitive medical imaging device, providing both functional and biochemical information, it has limited spatial resolution, signal-to-noise ratio, and anatomic information. Conversely, MRI offers detailed anatomic information about the brain along with excellent soft-tissue contrast and various types of hemodynamic information (i.e., perfusion and diffusion). Accordingly, the combination of PET and MRI can provide a 1-stop shop for clinical examination and new methodology for exploring the brain with multiparametric and complementary imaging information (5,6).

In addition, fully integrated PET/MRI scanners based on semiconductor photosensors, such as avalanche photodiodes and silicon photomultipliers, allow the simultaneous acquisition of both image datasets, which possess several distinct advantages over the sequential scan in conventional PET/CT examinations (7–11). Accurate spatiotemporal correlation of PET/MRI signals permits the studies to demonstrate the relationship between neurotransmitter release and hemodynamic change in the brain under various pathologic and pharmacologic circumstances. Head motion correction of PET images using the motion information derived from the rapidly acquired time series of MR images is another advantage of simultaneous PET/MRI scans. Moreover, the MRI-based extraction of arterial input function for PET kinetic analysis and partial-volume correction of PET has become easier to perform and more accurate (5,6,9,12–14).

However, the accuracy of attenuation correction of brain PET in PET/MRI studies is still questionable. Because the MRI signal is not directly related to the photon attenuation, PET attenuation correction in PET/MRI relies on MRI segmentation, population-based standard templates, or joint activity and attenuation estimation (15–18). The template-based method is robust but has limitations in accommodating the wide interindividual anatomic variability in patients’ brains (19–22). The MRI segmentation–based method using a 2-point Dixon sequence does not provide the bone segment, leading to the underestimation of uptake around the bone (23–27). Although the reconstruction algorithms for the joint estimation of activity and attenuation have great potential, the PET timing resolution that determines the accuracy of these algorithms is not good enough in current PET/MRI scanners (28–30).

The MRI-based attenuation correction (MR-AC) using an ultrashort echo time (UTE) MRI sequence derives the bone segment based on the difference between 2 MR images obtained at different echo times (ultrashort and typical times) (31,32). Thus, the most widely used clinical PET/MRI system (Biograph mMR; Siemens Healthcare) offers the UTE-based MR-AC along with the Dixon-based method for brain PET/MRI studies. However, the initial versions of the UTE sequence (i.e., mMR software version VB18P) yielded frequent segmentation errors at the boundary between soft tissue, bone, and air, and misclassification of the ventricle as air (33–35). Although a recent upgrade of the software from VB18P to VB20P offers more reliable attenuation maps than before, significant segmentation errors in the regions around the inferior part of the brain (i.e., sinus and lower skull structures) still exist. Moreover, considerable quantification errors because of the inaccurate UTE MR-AC have been reported in several articles (33–35).

Here, we propose an advanced UTE MR-AC method that is based on a multiphase level-set algorithm (36–38) to provide more accurate attenuation maps than those currently used in brain PET/MRI studies. The quantitative accuracy of this new method, providing a 3-segment (air, bone, and soft tissue) attenuation map, was compared with CT-based and mMR-providing attenuation corrections. For this comparison, we used image datasets obtained from 18F-fluorinated-N-3-fluoropropyl-2-β-carboxymethoxy-3-β-(4-iodophenyl)nortropane (18F-FP-CIT) and 18F-FDG brain PET/MRI and PET/CT studies.

MATERIALS AND METHODS

Patient Population

We evaluated our new MR-AC method using 2 different brain PET datasets. One of these was the 18F-FP-CIT PET/CT and PET/MRI data acquired in our previous study for evaluating the accuracy of existing MR-AC methods in patients with Parkinson disease (35). Four more PET studies have been added since the publication of the previous study; thus, a total of 20 patients (11 men, 9 women; mean age ± SD, 59.6 ± 9.1 y; age range, 54–71 y) were enrolled in this study. The other was 18F-FDG PET/CT and PET/MRI data of 10 prospectively enrolled healthy normal volunteers (6 men, 4 women; mean age ± SD, 57.7 ± 5.4 y; age range, 51–67 y) without any medical diseases or abnormalities uncovered in neuropsychologic screening tests. All these studies were approved by the Institutional Review Board of our institute, and all study participants signed an informed consent form.

PET/CT and PET/MRI Acquisition

PET/CT data were acquired using a Biograph mCT40 scanner (Siemens Healthcare) in 18F-FP-CIT studies and a Biograph TruePoint40 scanner in 18F-FDG studies. A Biograph mMR system was used for PET/MRI data acquisition in both studies. Although the mMR software version of VB18P was used in the 18F-FP-CIT studies, the software was upgraded to VB20P for the 18F-FDG studies. The VB20P is the latest version and provides improved UTE image quality by incorporating gradient delay correction, streak artifact suppression, and a more advanced MR-AC method. In this new version, skull segment is generated using a template-based approach and combined with the soft-tissue map obtained by applying MRI segmentation.

In the 18F-FP-CIT studies, a PET/MRI scan was obtained 110 min after the injection of a tracer (192 MBq on average) and followed by a PET/CT scan. In the 18F-FDG studies, the sequence of PET/MRI and PET/CT was randomly determined, and the first scan was obtained 40 min after the injection of the tracer (259 MBq on average). PET scan duration for 18F-FP-CIT and 18F-FDG was 10 min.

PET/CT Acquisition

PET/CT imaging was performed in a single PET bed position and the participants’ heads were positioned in a head holder attached to the patient bed. The PET/CT scan followed the routine clinical protocol for brain studies including a topogram scan, an attenuation CT scan, and a 10-min PET emission scan. For PET attenuation correction, the CT images were reconstructed in a 512 × 512 × 112 matrix with voxel sizes of 0.59 × 0.59 × 3 mm. The emission PET data were acquired in sinogram format.

PET/MR Acquisition

In PET/MRI, the participants’ heads were positioned in the mMR head coil. MR images were acquired simultaneously with PET using a dual-echo UTE sequence (echo time, 0.07 and 2.46 ms; repetition time, 11.9 ms; flip angle, 10°). The UTE images were reconstructed into a 192 × 192 × 192 matrix with an isotropic voxel size of 1.33 mm (Supplemental Fig. 1; supplemental materials are available at http://jnm.snmjournals.org). A T1-weighted 3-dimensional ultrafast gradient echo sequence was also acquired in a 208 × 256 × 256 matrix with voxel sizes of 1.0 × 0.98 × 0.98 mm.

MR-Based Attenuation Map Using Level-Set Algorithm

The T2 relaxation time of protons in bone tissue is much faster than in other tissues. Thus, bone tissues with short T2 can be distinguished from soft tissue by taking the subtraction or division between the first UTE image (UTE1) and the second longer TE image (UTE2). However, these images, especially UTE2, are sensitive to off-resonance effects because of main magnetic field (B0) inhomogeneity and susceptibility, causing inhomogeneity artifacts that make accurate image segmentation difficult (39). Thus, we generated a UTE MR-based attenuation map based on a level-set algorithm in which the intensity inhomogeneity correction was incorporated. These procedures were performed using in-house–developed code written in Matlab (R2014a; The MathWorks).

Level-Set Algorithm

Two-phase level-set segmentation based on the Chan and Vese multiphase model was applied to both the UTE1 and the UTE2, in which 2 level-set functions were evolved simultaneously (37). Local intensity clustering properties and region-based information were considered as proposed by Li et al. to unify the segmentation and inhomogeneity correction within a single evolving framework (38). Figure 1 shows the results of the level-set segmentation (the supplemental note provides detailed information on the level-set algorithm used in this study). The final evolved contours (red: level-set function 1 = 0; blue: level-set function 2 = 0) were overlaid on the MR images. The regions delimitated by the contours were represented in the binary images by assigning 1 to the inside of the contour and 0 to the outside. (UxLy is the binary image from the yth level-set function of the xth UTE in Figure 1. The symbol C labeled behind y indicates that the binary image is generated with inhomogeneity correction.)

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Generation of soft-tissue and air maps and additional mask using 2-phase level-set segmentation and morphologic and binary operations. Final evolved contours (red: level-set function 1 = 0, blue: level-set function 2 = 0) were overlaid on MR images. UxLy was binary image from xth level-set function of yth UTE. Soft-tissue and air maps were generated by filling holes in U1L1 and multiplying 2 binary images (∼U1L1 and ∼U2L1). Additionally, mask for trimming bone map was generated from binary images of level-set functions obtained using level-set segmentation with inhomogeneity correction (U2L1C ∩ ∼U2L2C).

Generation of Attenuation Map

The procedure for generating the attenuation map is similar to Keereman’s scheme (31). However, the accuracy of segmentation of each region was improved by the level-set method.

The soft-tissue map was obtained by applying a hole-filling operation to the U1L1 that encloses almost all of the structures in the head. Air has a negligibly low signal in both UTE images. Thus, we obtained an air map by multiplying ∼U1L1 and ∼U2L1 (Fig. 1). To generate the bone map, we started from the initial bone map generated by applying a threshold to the difference image (dUTE) between UTE1 and UTE2 (Fig. 2). The threshold was empirically determined and 50% of the mean intensity of dUTE pixels greater than 10. This initial bone map was then masked by the morphologically eroded soft-tissue map to correct for the misclassified voxels around the outer boundary of the skull with air. To further trim out the remaining misclassified soft tissue as bone in the dUTE image, we applied an additional mask generated by multiplying U2L1C and ∼U2L2C (Figs. 1 and 2).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Generation of bone map and final level-set–based attenuation map (MR-AClevel). Initial bone map generated by applying a threshold to difference image between UTE1 and UTE2 was further trimmed to yield final bone map by masking it with soft-tissue map and additional mask. MR-AClevel map was then generated by assigning attenuation coefficients to soft-tissue, bone, and air maps and combining them.

Finally, we added the bone segment to the initial attenuation map, and assigned the attenuation coefficients for soft tissue and bone (0.1 and 0.151 cm−1). The computing time for generation of the attenuation map using the level-set method was approximately 5 min when this method was implemented using Matlab code (version R2014a) and executed on a personal computer with Intel Core i5-2500 Processor (3.3 GHz).

Image Processing and Reconstruction

Reconstructed PET images were generated from emission data in the PET/CT studies using 3 different attenuation maps. The first one was the MR-based attenuation map that is offered by the Biograph mMR software (MR-ACmMR map). The second one was the MR-based attenuation map generated using the proposed multiphase level-set method (MR-AClevel map). The last one was the CT-based attenuation map conventionally used in PET/CT studies, which was converted from the CT images to 511-keV attenuation coefficients using a bilinear transformation (CT-AC map).

For each participant, 2 MR-based attenuation maps were coregistered and resliced to the CT-AC map using the statistical parametric mapping (SPM8; University of College London) software through the coregistration of T1 3-dimensional MRI to CT. The PET/CT head holder was visible in the CT-AC map, whereas the UTE images were without the head holder. Therefore, the head holder shown in the CT image was extracted using a region-growing segmentation algorithm and added to the MR-based attenuation maps to allow a fair comparison. All PET images were reconstructed using the ordinary Poisson ordered-subset expectation maximization (subsets, 14; iterations, 3) algorithm through e7tool from Siemens Healthcare. After reconstruction, all PET data were spatially normalized to the SPM standard MRI T1 template to eliminate intersubject anatomic variability. The overall image processing steps are summarized in Supplemental Figure 2.

Image Analysis

The quantitative accuracies of the 2 MR-AC methods relative to CT-AC were compared using the similarity measurements of attenuation maps and absolute and relative differences between PET images.

The accuracy of the attenuation maps were evaluated using Dice similarity coefficients (40–42) that measure the overlap of the segmented bone and air regions of MR-AC maps with respect to those of CT-AC maps (1 for perfect overlap and 0 for no overlapping) according to the following equation:Embedded Image

where N is the number of bone (or air) voxels in each image. In the CT-AC map, the voxels with μ greater than 0.1134 (=300 Hounsfield units) were classified into bone and the voxels with μ less than 0.0475 (= −500 Hounsfield units) were air (32,41). The Dice coefficients were calculated for the entire head and for the cranial region, separately (40).

We measured the PET activity concentration in 5 regions of interest (ROIs) (caudate nucleus, putamen, thalamus, occipital, and cerebellum) for 18F-FP-CIT studies and 10 ROIs (frontal, temporal, parietal, occipital, insula, striatum, precuneus, amygdala/hippocampus, thalamus, and cerebellum) for 18F-FDG studies using an automatic ROI-delineation method with statistical probabilistic anatomic maps (43). The mean SUV of each ROI and its ratio to the cerebellum (SUVr) were calculated. The relative ratio of specific binding (binding ratio, [Cspecific – Cnonspecific]/Cnonspecific) was also calculated to assess the 18F-FP-CIT binding in the caudate nucleus and putamen (Cspecific and Cnonspecific: activity concentrations in specific and nonspecific [cerebellum] binding regions, respectively).

For the voxelwise comparison, all the PET images were spatially normalized as shown in Supplemental Figure 2, mean PET images of MR-AC and CT-AC were generated, and their absolute and relative difference maps were generated.

RESULTS

The results of CT-AC, MR-ACmMR, and MR-AClevel applied to the same emission data acquired using PET/CT machines are compared in Figures 3 and 4 (Fig. 3 for 18F-FP-CIT PET with VB18P mMR software, Fig. 4 for 18F-FDG PET and VB20P). The MR-ACmMR map gave larger air cavities than CT regardless of the version of mMR software. The bone tissue in the MR-ACmMR map was underestimated in VB18P (Fig. 3B) and overestimated in VB20P (Fig. 4B). On the contrary, MR-AClevel maps (Figs. 3C and 4C) showed more similar properties with CT (Figs. 3A and 4A) in the size and shape of the air cavities and bones. Although the striatal and cerebellar activity in 18F-FP-CIT PET and frontal activity in 18F-FDG PET were remarkably underestimated in MR-ACmMR relative to CT-AC (Figs. 3B and 4B), MR-AClevel did not show this discrepancy from CT-AC (Figs. 3C and 4C).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Attenuation maps and 18F-FP-CIT PET images corrected using them. (A) CT. (B) MR-ACmMR: MR-based attenuation map generated using mMR software version VB18P. (C) MR-AClevel: MR-based attenuation map generated using level-set method.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Attenuation maps and 18F-FDG PET images corrected using them. (A) CT. (B) MR-ACmMR using mMR software version VB20P. (C) MR-AClevel.

The Dice similarity coefficients between MR-AC and CT-AC maps are summarized in Table 1. The mean Dice coefficients for bone in MR-AClevel were 0.60 and 0.79 (VB18P and VB20P) for the whole head and 0.71 and 0.83 for the cranial region only, and all of them were higher than those in MR-ACmMR. There was the same trend for air regions.

View this table:
  • View inline
  • View popup
TABLE 1

Dice Similarity Coefficients for Whole Head and Cranial Bone (Mean ± SD)

The superiority of MR-AClevel to MR-ACmMR was confirmed in the ROI- and voxel-based quantitative comparisons. Figures 5 and 6 show the results of ROI-based analysis on 18F-FP-CIT and 18F-FDG PET data, respectively. In 18F-FP-CIT studies with MR-ACmMR, the percentage difference of SUV from CT-AC was greater than –20% in most ROIs (Fig. 5A). The percentage difference was most remarkable in the cerebellum, leading to the overestimation of SUVr, which was highest in the putamen (Fig. 5B). Conversely, the percentage difference of 18F-FP-CIT PET with MR-AClevel from CT-AC was smaller than 10% in both SUV and SUVr. The binding ratio values offered by the MR-AC methods were linearly correlated with those by CT-AC; nevertheless, the MR-AClevel (putamen: y = 1.04x ± 0.016; caudate: y = 1.04x ± 0.021) yielded a smaller bias than MR-ACmMR (putamen: y = 1.11x ± 0.038; caudate: y = 1.14x ± 0.073) (Supplemental Figs. 3–6).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Percentage difference of SUV (A) and SUVr (B) from CT-AC in 18F-FP-CIT PET.

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Percentage difference of SUV (A) and SUVr (B) from CT-AC in 18F-FDG PET.

The 18F-FDG PET tests showed a trend similar to the 18F-FP-CIT PET tests, whereas the percentage differences in SUV and SUVr between MR-AC and CT-AC were roughly half of those in 18F-FP-CIT PET (Fig. 6; Supplemental Figs. 7–9). Figure 7 shows that there was a remarkable difference in almost every brain region in the voxelwise comparison between MR-ACmMR and CT-AC. On the contrary, the difference between MR-AClevel and CT-AC was limited to the brain cortex. In both methods, the outer boundary of brain cortex, which is vulnerable to the brain size mismatch and registration error between CT and MRI and errors in skull segmentation, showed the largest differences.

FIGURE 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7.

Absolute (left) and percentage (right) difference of SUV in 18F-FDG PET images. (A) MR-AClevel with respect to CT-AC. (B) MR-ACmMR with respect to CT-AC.

DISCUSSION

In this study, we developed a new UTE MR-AC map based on a unified multiphase level-set segmentation and inhomogeneity correction method and demonstrated the superior performance of this method over the currently used MR-AC map in an mMR PET/MRI scanner. The remarkable improvements in the segmentation of air cavities and bone and the quantitative accuracy of PET measurement using the level-set method were shown in both the 18F-FP-CIT PET data using VB18P mMR software and the 18F-FDG PET data using VB20P.

The major upgrade of mMR software from VB18P to VB20P seems to be effective in the elimination of misclassification of cerebrospinal fluid in ventricles as air and the correction of bone underestimation shown in previous reports (33–35). The percentage error of MR-ACmMR in SUV and SUVr quantification relative to CT-AC was reduced approximately by half, although we could not confirm this error reduction using the exact same dataset. However, the current VB20P version still yields air cavity and bone segmentation errors as shown in Figure 4B. However, the MR-AClevel offered improved segmentation results, leading to the reduction of PET quantification error by a factor of approximately 3 as shown in Figure 5 (SUV error < 10% in MR-AClevel and < 30% in MR-ACmMR with VB18P, and < 5% in MR-AClevel and < 15% in MR-ACmMR with VB20P). The evaluation of attenuation maps using Dice coefficients confirmed the improvements in the MR-AC maps achieved by the level-set method (Table 1). For VB20P UTE datasets, MR-AClevel yielded the Dice coefficient for bone of 0.83 in the cranial region whereas MR-ACmMR offered 0.74 in this study and 0.65 in a previous study (40).

The results suggest that UTE MR-AClevel provides more accurate PET quantification than Dixon-based AC methods that yielded around 10%–20% errors in the study by Dickson et al. (33) and 5%–15% in the study by Izquierdo-Garcia et al. (17) depending on brain regions (larger error in cortical regions). Recent advanced template-based approaches (17) and new approaches with R2* to Hounsfield unit conversion (41) and zero-echo time (42) show results similar to our approach or great potential for further improvement of MR-AC. The combination of our approach with those methods would be the interesting next step that we can take to improve the MR-AC in brain and potentially in whole-body PET/MRI studies.

The advanced results using the level-set method can be attributed to the combined effects of various factors in this study. These factors include the inhomogeneity correction of UTE images incorporated into the level-set segmentation, which led to the more reliable segmentation results. The assorted boundary information provided by the multiphase level-set segmentations applied to both the UTE images were useful for determining the complex boundaries among different segments and trimming the segmentation results through morphologic operations on the binary images.

Although MR-AClevel yielded SUV quantification results almost equivalent to CT-AC in most brain regions, the errors in the cerebellum and occipital cortex were larger than in other regions (Figs. 5A and 6A). The errors in these most common reference regions in brain PET studies resulted in positive biases in binding ratios and SUVr estimations (Figs. 5B and 6B; Supplemental Figs. 5 and 6). It is most likely that the errors in these posterior and inferior brain regions are related to the misclassification of fat tissues in the neck as bone. This misclassification, also observed in Figures 3C and 4C, is likely caused by the image intensity brightening at the periphery of UTE images mainly because of the inhomogeneous B1 field associated with multichannel phased array coils (39,44).

Thus, we expect to achieve more accurate UTE segmentation and MR-based attenuation correction through the further optimization of UTE sequences (i.e., the reduction of off-resonance effects, robustness enhancement of non-Cartesian data acquisition, and saturation of fat tissues) (45).

CONCLUSION

We have developed a UTE MR-AC method using level-set segmentation with inhomogeneity correction for brain PET/MRI studies and demonstrated the feasibility of this method in brain PET/MRI studies with 18F-FP-CIT and 18F-FDG. The MR-based attenuation maps generated using level-set segmentation and PET images corrected for attenuation and scatter were superior to those offered by the manufacturer of the PET/MRI system in terms of the similarity to the CT-AC. This method will be useful for improving the quantitative accuracy of brain PET in PET/MRI studies.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This work was supported by grants from the Ministry of Trade, Industry & Energy (10030030); the National Research Foundation of Korea (NRF-2014M3C7034000); and the Korea Health Industry Development Institute (HI13C01630200) and an Intramural Research Grant of Seoul National University (grant 0420130670, 2013-1290). No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Dec. 23, 2015.

  • © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Silverman DH
    . Brain 18F-FDG PET in the diagnosis of neurodegenerative dementias: comparison with perfusion SPECT and with clinical evaluations lacking nuclear imaging. J Nucl Med. 2004;45:594–607.
    OpenUrlAbstract/FREE Full Text
  2. 2.
    1. Kazumata K,
    2. Dhawan V,
    3. Chaly T,
    4. et al
    . Dopamine transporter imaging with fluorine-18-FPCIT and PET. J Nucl Med. 1998;39:1521–1530.
    OpenUrlAbstract/FREE Full Text
  3. 3.
    1. Biswal B,
    2. Yetkin FZ,
    3. Haughton VM,
    4. Hyde JS
    . Functional connectivity in the motor cortex of resting human brain using echo-planar MRI. Magn Reson Med. 1995;34:537–541.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Frisoni GB,
    2. Fox NC,
    3. Jack CR Jr.,
    4. Scheltens P,
    5. Thompson PM
    . The clinical use of structural MRI in Alzheimer disease. Nat Rev Neurol. 2010;6:67–77.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Catana C,
    2. Drzezga A,
    3. Heiss WD,
    4. et al
    . PET/MRI for neurologic applications. J Nucl Med. 2012;53:1916–1925.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Drzezga A,
    2. Barthel H,
    3. Minoshima M,
    4. et al
    . Potential clinical applications of PET/MR imaging in neurodegenerative disease. J Nucl Med. 2014;55:47S–55S.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Pichler BJ,
    2. Judenhofer MS,
    3. Catana C,
    4. et al
    . Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. J Nucl Med. 2006;47:639–647.
    OpenUrlAbstract/FREE Full Text
  8. 8.
    1. Catana C,
    2. Wu Y,
    3. Judenhofer MS,
    4. et al
    . Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med. 2006;47:1968–1976.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Schlemmer HP,
    2. Pichler B,
    3. Schm M,
    4. et al
    . Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology. 2008;248:1028–1035.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Yoon HS,
    2. Ko GB,
    3. Kwon SI,
    4. et al
    . Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner. J Nucl Med. 2012;53:608–614.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Yamamoto S,
    2. Watabe T,
    3. Watabe H,
    4. et al
    . Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system. Phys Med Biol. 2012;57:N1–N13.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Wehrl HF,
    2. Hossain M,
    3. Lankes K,
    4. et al
    . Simultaneous PET-MRI reveals brain function in activated and resting state on metabolic, hemodynamic and multiple temporal scales. Nat Med. 2013;19:1184–1189.
    OpenUrlCrossRefPubMed
  13. 13.
    1. Sander CY,
    2. Hooker JM,
    3. Catana C,
    4. et al
    . Neurovascular coupling to D2/D3 dopamine receptor occupancy using simultaneous PET/functional MRI. Proc Natl Acad Sci USA. 2013;110:11169–11174.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Lee JS,
    2. Kim JH
    . Recent advances in hybrid molecular imaging systems. Semin Musculoskelet Radiol. 2014;18:103–122.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Keereman V,
    2. Mollet P,
    3. Berker Y,
    4. et al
    . Challenges and current methods for attenuation correction in PET/MR. MAGMA. 2013;26:81–98.
    OpenUrlCrossRefPubMed
  16. 16.
    1. Wagenknecht G,
    2. Kaiser H-J,
    3. Mottaghy FM,
    4. et al
    . MRI for attenuation correction in PET: methods and challenges. MAGMA. 2013;26:99–113.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Izquierdo-Garcia D,
    2. Hansen AE,
    3. Förster S,
    4. et al
    . An SPM8-based approach for attenuation correction combining segmentation and nonrigid template formation: application to simultaneous PET/MR brain imaging. J Nucl Med. 2014;55:1825–1830.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Yoo HJ,
    2. Lee JS,
    3. Jee JM
    . Integrated whole body PET/MRI: where are we? Korean J Radiol. 2015;16:32–49.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Montandon M-L,
    2. Zaidi H
    . Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. Neuroimage. 2005;25:278–286.
    OpenUrlCrossRefPubMed
  20. 20.
    1. Kops ER,
    2. Herzog H
    . Alternative methods for attenuation correction for PET images in MR-PET scanners. Nucl Sci Symp Conf Rec. 2007;6:4327–4330.
    OpenUrl
  21. 21.
    1. Malone IB,
    2. Ansorge RE,
    3. Williams GB,
    4. et al
    . Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches. J Nucl Med. 2011;52:1142–1149.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Hofmann M,
    2. Bezrukov I,
    3. Mantlik F,
    4. et al
    . MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and Atlas-based methods. J Nucl Med. 2011;52:1392–1399.
    OpenUrlAbstract/FREE Full Text
  23. 23.↵
    1. Martinez-Möller A,
    2. Souvatzoglou M,
    3. Delso G,
    4. et al
    . Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50:520–526.
    OpenUrlAbstract/FREE Full Text
  24. 24.
    1. Keereman V,
    2. Holen RV,
    3. Mollet P,
    4. et al
    . The effect of errors in segmented attenuation maps on PET quantification. Med Phys. 2011;38:6010–6019.
    OpenUrlCrossRefPubMed
  25. 25.
    1. Berker Y,
    2. Franke J,
    3. Salomon A,
    4. et al
    . MRI-based attenuation correction for hybrid PET/MRI systems: a 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence. J Nucl Med. 2012;53:796–804.
    OpenUrlAbstract/FREE Full Text
  26. 26.
    1. Samarin A,
    2. Burger C,
    3. Wollenweber SD,
    4. et al
    . PET/MR imaging of bone lesions–implications for PET quantification from imperfect attenuation correction. Eur J Nucl Med Mol Imaging. 2012;39:1154–1160.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Kim JH,
    2. Lee JS,
    3. Song IC,
    4. et al
    . Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data. J Nucl Med. 2012;53:1878–1882.
    OpenUrlAbstract/FREE Full Text
  28. 28.↵
    1. Nuyts J,
    2. Dupont P,
    3. Stroobants S,
    4. et al
    . Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sonograms. IEEE Trans Med Imaging. 1999;18:393–403.
    OpenUrlCrossRefPubMed
  29. 29.
    1. Salomon A,
    2. Goedicke A,
    3. Schweizer B,
    4. et al
    . Simultaneous reconstruction of activity and attenuation for PET/MR. IEEE Trans Med Imaging. 2011;30:804–813.
    OpenUrlCrossRefPubMed
  30. 30.↵
    1. Rezaei A,
    2. Defrise M,
    3. Bal G,
    4. et al
    . Simultaneous reconstruction of activity and attenuation in time-of-flight PET. IEEE Trans Med Imaging. 2012;31:2224–2233.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Keereman V,
    2. Fierens Y,
    3. Broux T,
    4. et al
    . MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med. 2010;51:812–818.
    OpenUrlAbstract/FREE Full Text
  32. 32.↵
    1. Catana C,
    2. van der Kouwe A
    . Benner, et al. T Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med. 2010;51:1431–1438.
    OpenUrlAbstract/FREE Full Text
  33. 33.↵
    1. Dickson JC,
    2. O’Meara C,
    3. Barnes A
    . A comparison of CT- and MR-based attenuation correction in neurological PET. Eur J Nucl Med Mol Imaging. 2014;41:1176–1189.
    OpenUrlCrossRefPubMed
  34. 34.
    1. Cabello J,
    2. Lukas M,
    3. Förster S,
    4. et al
    . MR-based attenuation correction using ultrashort-echo-time pulse sequences in dementia patients. J Nucl Med. 2015;56:423–429.
    OpenUrlAbstract/FREE Full Text
  35. 35.↵
    1. Choi H,
    2. Cheon GJ,
    3. Kim H-J,
    4. et al
    . Segmentation-based MR attenuation correction including bones also affects quantitation in brain studies: an initial result of 18F-FP-CIT PET/MR for patients with parkinsonism. J Nucl Med. 2014;55:1617–1622.
    OpenUrlAbstract/FREE Full Text
  36. 36.↵
    1. Chan TF,
    2. Vese LA
    . Active contours without edges. IEEE Trans Image Process. 2001;10:266–277.
    OpenUrlCrossRefPubMed
  37. 37.↵
    1. Vese LA,
    2. Chan TF
    . A multiphase level set framework for image segmentation using the Mumford and Shah model. Int J Comput Vis. 2002;53:271–293.
    OpenUrl
  38. 38.↵
    1. Li C,
    2. Huang R,
    3. Ding Z,
    4. et al
    . A level set method for image segmentation in the presence of intensity inhomogeneities with application to MRI. IEEE Trans Image Process. 2011;20:2007–2016.
    OpenUrlCrossRefPubMed
  39. 39.↵
    1. Robson MD,
    2. Gatehouse PD,
    3. Bydder M,
    4. et al
    . Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr. 2003;27:825–846.
    OpenUrlCrossRefPubMed
  40. 40.↵
    1. Aasheim LB,
    2. Karlberg A,
    3. Goa PE,
    4. et al
    . PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction. Eur J Nucl Med Mol Imaging. 2015;42:1439–1446.
    OpenUrlCrossRefPubMed
  41. 41.↵
    1. Juttukonda MR,
    2. Mersereau BG,
    3. Chen Y,
    4. et al
    . MR-based attenuation correction for PET/MRI neurological studies with continuous-valued attenuation coefficients for bone through a conversion from R2* to CT-Hounsfield units. Neuroimage. 2015;112:160–168.
    OpenUrlCrossRefPubMed
  42. 42.↵
    1. Delso G,
    2. Wiesinger F,
    3. Sacolick LI,
    4. et al
    . Clinical evaluation of zero-echo-time MR imaging for the segmentation of the skull. J Nucl Med. 2015;56:417–422.
    OpenUrlAbstract/FREE Full Text
  43. 43.↵
    1. Lee JS,
    2. Lee DS
    . Analysis of functional brain images using population-based probabilistic atlas. Curr Med Imaging Rev. 2005;1:81–87.
    OpenUrlCrossRef
  44. 44.↵
    1. Pilkinton DT,
    2. Elliott MA,
    3. Magland J
    . Sodium MRI multi-echo sequence for simultaneous ultra-short echo imaging and T2L* mapping at 7T with a 12 channel phased-array coil [abstract]. Proc Intl Soc Mag Reson Med. 2010;18:1002.
    OpenUrl
  45. 45.↵
    1. Aitken AP,
    2. Giese D,
    3. Tsoumpas C,
    4. et al
    . Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring. Med Phys. 2014;41:012302.
    OpenUrlCrossRefPubMed
  • Received for publication July 9, 2015.
  • Accepted for publication November 25, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 57 (4)
Journal of Nuclear Medicine
Vol. 57, Issue 4
April 1, 2016
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
Hyun Joon An, Seongho Seo, Hyejin Kang, Hongyoon Choi, Gi Jeong Cheon, Han-Joon Kim, Dong Soo Lee, In Chan Song, Yu Kyeong Kim, Jae Sung Lee
Journal of Nuclear Medicine Apr 2016, 57 (4) 587-593; DOI: 10.2967/jnumed.115.163550

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
Hyun Joon An, Seongho Seo, Hyejin Kang, Hongyoon Choi, Gi Jeong Cheon, Han-Joon Kim, Dong Soo Lee, In Chan Song, Yu Kyeong Kim, Jae Sung Lee
Journal of Nuclear Medicine Apr 2016, 57 (4) 587-593; DOI: 10.2967/jnumed.115.163550
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Generation of PET Attenuation Map for Whole-Body Time-of-Flight 18F-FDG PET/MRI Using a Deep Neural Network Trained with Simultaneously Reconstructed Activity and Attenuation Maps
  • Improving the Accuracy of Simultaneously Reconstructed Activity and Attenuation Maps Using Deep Learning
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • PET/MRI
  • attenuation correction
  • level-set segmentation
  • brain PET
SNMMI

© 2025 SNMMI

Powered by HighWire