OtherBasic Science (Animal or Phantoms)
Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra
Yihuan Lu, Mika Naganawa, Takuya Toyonaga, Jean-Dominique Gallezot, Kathryn Fontaine, Silin Ren, Enette Mae Revilla, Tim Mulnix and Richard E. Carson
Journal of Nuclear Medicine February 2020, jnumed.119.235515; DOI: https://doi.org/10.2967/jnumed.119.235515
Yihuan Lu
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Mika Naganawa
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Takuya Toyonaga
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Jean-Dominique Gallezot
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Kathryn Fontaine
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Silin Ren
2 Biomedical Engineering, Yale University, United States
Enette Mae Revilla
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Tim Mulnix
1 Department of Radiology and Biomedical Imaging, Yale University, United States;
Richard E. Carson
1 Department of Radiology and Biomedical Imaging, Yale University, United States;

Article Figures & Data
Additional Files
Supplemental Data
Files in this Data Supplement:
In this issue
Journal of Nuclear Medicine
Vol. 66, Issue 5
May 1, 2025
Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra
Yihuan Lu, Mika Naganawa, Takuya Toyonaga, Jean-Dominique Gallezot, Kathryn Fontaine, Silin Ren, Enette Mae Revilla, Tim Mulnix, Richard E. Carson
Journal of Nuclear Medicine Feb 2020, jnumed.119.235515; DOI: 10.2967/jnumed.119.235515
Data-driven motion detection and event-by-event correction for brain PET: Comparison with Vicra
Yihuan Lu, Mika Naganawa, Takuya Toyonaga, Jean-Dominique Gallezot, Kathryn Fontaine, Silin Ren, Enette Mae Revilla, Tim Mulnix, Richard E. Carson
Journal of Nuclear Medicine Feb 2020, jnumed.119.235515; DOI: 10.2967/jnumed.119.235515
Jump to section
Related Articles
Cited By...
- Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
- Fully Automated, Fast Motion Correction of Dynamic Whole-Body and Total-Body PET/CT Imaging Studies
- Conditional Generative Adversarial Networks Aided Motion Correction of Dynamic 18F-FDG PET Brain Studies
- Ultra-Fast List-Mode Reconstruction of Short PET Frames and Example Applications