Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherBasic Science (Animal or Phantoms)

Evaluation of a novel elastic respiratory motion correction algorithm on quantification and image quality in abdomino-thoracic PET/CT

Joseph G Meier, Carol C Wu, Sonia L Betancourt Cuellar, Mylene T Truong, Jeremy R Erasmus, Samuel Einstein and Osama Mawlawi
Journal of Nuclear Medicine August 2018, jnumed.118.213884; DOI: https://doi.org/10.2967/jnumed.118.213884
Joseph G Meier
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Carol C Wu
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sonia L Betancourt Cuellar
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mylene T Truong
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeremy R Erasmus
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Samuel Einstein
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Osama Mawlawi
MD Anderson Cancer Center, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Article Information

jnumed.118.213884
DOI 
https://doi.org/10.2967/jnumed.118.213884
PubMed 
30115689

Published By 
Society of Nuclear Medicine
Print ISSN 
0161-5505
Online ISSN 
2159-662X
History 
  • Published online August 16, 2018.

Article Versions

  • You are currently viewing a previous version of this article (August 16, 2018 - 11:37).
  • View the most recent version of this article
Copyright & Usage 
Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Author Information

  1. Joseph G Meier,
  2. Carol C Wu,
  3. Sonia L Betancourt Cuellar,
  4. Mylene T Truong,
  5. Jeremy R Erasmus,
  6. Samuel Einstein and
  7. Osama Mawlawi
  1. MD Anderson Cancer Center, United States
  1. For correspondence or reprints contact: Osama Mawlawi, MD Anderson Cancer Center, 1515 Holcombe Blvd, Box 1352, Houston, Tx 77030, United States. E-mail: omawlawi@mdanderson.org

Statistics from Altmetric.com

Cited By...

  • 14 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients
    Willem Grootjans, Daphne D.D. Rietbergen, Floris H.P. van Velden
    Seminars in Nuclear Medicine 2022 52 6
  • Data-driven gated PET/CT: implications for lesion segmentation and quantitation
    M. Allan Thomas, Tinsu Pan
    EJNMMI Physics 2021 8 1
  • Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT
    James J. Hamill, Joseph G. Meier, Sonia L. Betancourt Cuellar, Bradley Sabloff, Jeremy J. Erasmus, Osama Mawlawi
    Journal of Nuclear Medicine 2020 61 9
  • Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction
    Stefanie Pösse, Florian Büther, Dirk Mannweiler, Inki Hong, Judson Jones, Michael Schäfers, Klaus Peter Schäfers
    EJNMMI Physics 2020 7 1
  • Impact of acquisition time and misregistration with CT on data-driven gated PET
    M Allan Thomas, Joseph G Meier, Osama R Mawlawi, Peng Sun, Tinsu Pan
    Physics in Medicine & Biology 2022 67 8
  • Characterization of continuous bed motion effects on patient breathing and respiratory motion correction in PET/CT imaging
    Joseph G. Meier, Jeremy J. Erasmus, Gregory W. Gladish, Christine B. Peterson, Radwan H. Diab, Osama R. Mawlawi
    Journal of Applied Clinical Medical Physics 2020 21 1
  • Evaluating two respiratory correction methods for abdominal PET/MRI imaging
    Weiwei Ruan, Fang Liu, Xun Sun, Fan Hu, Tingfan Wu, Yongxue Zhang, Xiaoli Lan
    EJNMMI Physics 2022 9 1
  • Motion-correction strategies for enhancing whole-body PET imaging
    James Wang, Dalton Bermudez, Weijie Chen, Divya Durgavarjhula, Caitlin Randell, Meltem Uyanik, Alan McMillan
    Frontiers in Nuclear Medicine 2024 4
  • Evaluation of Data-Driven Respiration Gating in Continuous Bed Motion in Lung Lesions
    Takeshi Nii, Shota Hosokawa, Tomoya Kotani, Hiroshi Domoto, Yasunori Nakamura, Yasutomo Tanada, Ryotaro Kondo, Yasuyuki Takahashi
    Journal of Nuclear Medicine Technology 2023 51 1
  • Correcting CT misregistration in data‐driven gated (DDG) PET with PET self‐gating and deformable image registration
    Peng Sun, M. Allan Thomas, Dershan Luo, Tinsu Pan
    Medical Physics 2024 51 3

Article usage

Article usage: August 2018 to April 2025

AbstractFullPdf
Aug 2018342046
Sep 2018176021
Oct 2018152011
Nov 201813509
Dec 201810505
Jan 20196302
Feb 20198391960
Mar 2019190311
Apr 201910664
May 201980011
Jun 20195717
Jul 20198037
Aug 201964834
Sep 201952623
Oct 2019341339
Nov 2019491741
Dec 2019351015
Jan 2020431116
Feb 2020526053
Mar 2020333727
Apr 2020251224
May 2020304635
Jun 2020202624
Jul 202038712
Aug 202021621
Sep 202023619
Oct 2020391620
Nov 202022815
Dec 2020191213
Jan 2021121918
Feb 2021133030
Mar 202181732
Apr 202181323
May 2021132027
Jun 202153411
Jul 20215819
Aug 202131726
Sep 202162111
Oct 202172353
Nov 202142025
Dec 202182022
Jan 20227118
Feb 202210109
Mar 202283121
Apr 202243011
May 2022769
Jun 202261810
Jul 202210185
Aug 202291319
Sep 202271613
Oct 202281015
Nov 20223514
Dec 2022653
Jan 20235158
Feb 202341912
Mar 202352610
Apr 20235177
May 202341822
Jun 202341118
Jul 2023169
Aug 2023121711
Sep 2023257
Oct 20236157
Nov 20234149
Dec 202341189
Jan 202410206
Feb 2024185
Mar 20242726
Apr 202412312
May 202447513
Jun 20246146
Jul 202491321
Aug 2024323414
Sep 202416196
Oct 202451513
Nov 2024664
Dec 20241157
Jan 20258249
Feb 202589217
Mar 202535510
Apr 2025922167
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 66 (5)
Journal of Nuclear Medicine
Vol. 66, Issue 5
May 1, 2025
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of a novel elastic respiratory motion correction algorithm on quantification and image quality in abdomino-thoracic PET/CT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Evaluation of a novel elastic respiratory motion correction algorithm on quantification and image quality in abdomino-thoracic PET/CT
Joseph G Meier, Carol C Wu, Sonia L Betancourt Cuellar, Mylene T Truong, Jeremy R Erasmus, Samuel Einstein, Osama Mawlawi
Journal of Nuclear Medicine Aug 2018, jnumed.118.213884; DOI: 10.2967/jnumed.118.213884

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Evaluation of a novel elastic respiratory motion correction algorithm on quantification and image quality in abdomino-thoracic PET/CT
Joseph G Meier, Carol C Wu, Sonia L Betancourt Cuellar, Mylene T Truong, Jeremy R Erasmus, Samuel Einstein, Osama Mawlawi
Journal of Nuclear Medicine Aug 2018, jnumed.118.213884; DOI: 10.2967/jnumed.118.213884
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Evaluation of Data-Driven Respiration Gating in Continuous Bed Motion in Lung Lesions
  • Google Scholar

Similar Articles

Keywords

  • Image Processing
  • PET/CT
  • Respiratory
  • quantification
  • Respiratory motion correction
SNMMI

© 2025 SNMMI

Powered by HighWire