Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherClinical Investigations (Human)

Clinical evaluation of ZTE attenuation correction for brain FDG-PET/MR imaging—comparison with atlas attenuation correction

Tetsuro Sekine, Edwin EGW ter Voert, Geoffrey Warnock, Alfred Buck, Martin W Huellner, Patrick Veit-Haibach and Gaspar Delso
Journal of Nuclear Medicine June 2016, jnumed.116.175398; DOI: https://doi.org/10.2967/jnumed.116.175398
Tetsuro Sekine
1 University Hospital Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edwin EGW ter Voert
1 University Hospital Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Geoffrey Warnock
1 University Hospital Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alfred Buck
2 Universitatsspital Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin W Huellner
3 University Hospital Zurich / University of Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrick Veit-Haibach
1 University Hospital Zurich, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gaspar Delso
4 GE Healthcare
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Accurate attenuation correction (AC) on PET/MR is still challenging. The purpose of this study was to evaluate the clinical feasibility of AC based on fast zero-echo-time (ZTE) MR imaging by comparing it the default atlas-based AC on a clinical PET/MR scanner. Methods: We recruited 10 patients with malignant diseases not located on the brain. In all patients, a clinically-indicated whole-body 18F-FDG-PET/CT was acquired. In addition, a head PET/MR scan (GE SIGNA TOF-PET/MR) was performed voluntarily. For each patient, two AC maps were generated from the MR images. One was Atlas-AC, derived from T1-weighted LAVA-FLEX images (clinical standard). The other was ZTE-AC, derived from proton-density-weighted ZTE images by applying tissue segmentation and assigning continuous attenuation values to the bone. The AC map generated by PET/CT was used as silver standard. Based on each AC map, PET images were reconstructed from identical raw data on the PET/MR scanner. All PET images were normalized to the SPM5 PET template. After that, these images were qualified visually and quantified in 67 volumes-of-interest (VOIs; automated anatomical labeling (AAL), atlas). Relative differences (%diff) and absolute relative differences (|%diff|) between PET images based on each AC were calculated. FDG uptake in all 670 VOIs and generalized merged VOIs were compared using paired t-test. Results: Qualitative analysis shows that ZTE-AC was robust to patient variability. Nevertheless, misclassification of air and bone in mastoid and nasal areas led the overestimation of PET in the temporal lobe and cerebellum (%diff of ZTE-AC; 2.46±1.19% and 3.31±1.70%, respectively). The |%diff| of all 670 VOIs on ZTE was improved by approximately 25% compared to Atlas-AC (ZTE-AC vs. Atlas-AC; 1.77±1.41% vs. 2.44±1.63%, P < 0.01). In two out of seven generalized VOIs, |%diff| on ZTE-AC were significantly smaller than Atlas-AC (ZTE-AC vs. Atlas-AC; Insula and cingulate, 1.06±0.67% vs. 2.22±1.10%, P < 0.01; central structure, 1.03±0.99% vs. 2.54±1.20%, P < 0.05). Conclusion: The ZTE-AC could provide more accurate AC than clinical Atlas-AC by improving the estimation of head skull attenuation. The misclassification in mastoid and nasal areas must be addressed to prevent the overestimation of PET in regions near the skull base.

  • Bone
  • MRI
  • PET
  • PET/MRI
  • FDG
  • PET/MR
  • ZTE
  • attenuation correction
  • neuroimaging
  • Copyright © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Next
Back to top

In this issue

Journal of Nuclear Medicine: 66 (6)
Journal of Nuclear Medicine
Vol. 66, Issue 6
June 1, 2025
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Clinical evaluation of ZTE attenuation correction for brain FDG-PET/MR imaging—comparison with atlas attenuation correction
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Clinical evaluation of ZTE attenuation correction for brain FDG-PET/MR imaging—comparison with atlas attenuation correction
Tetsuro Sekine, Edwin EGW ter Voert, Geoffrey Warnock, Alfred Buck, Martin W Huellner, Patrick Veit-Haibach, Gaspar Delso
Journal of Nuclear Medicine Jun 2016, jnumed.116.175398; DOI: 10.2967/jnumed.116.175398

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Clinical evaluation of ZTE attenuation correction for brain FDG-PET/MR imaging—comparison with atlas attenuation correction
Tetsuro Sekine, Edwin EGW ter Voert, Geoffrey Warnock, Alfred Buck, Martin W Huellner, Patrick Veit-Haibach, Gaspar Delso
Journal of Nuclear Medicine Jun 2016, jnumed.116.175398; DOI: 10.2967/jnumed.116.175398
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • [18F]DPA-714 PET Imaging in the Presurgical Evaluation of Patients With Drug-Resistant Focal Epilepsy
  • Brain and systemic inflammation in de novo Parkinsons disease
  • A Path to Qualification of PET/MRI Scanners for Multicenter Brain Imaging Studies: Evaluation of MRI-Based Attenuation Correction Methods Using a Patient Phantom
  • In vivo synaptic density loss is related to tau deposition in amnestic mild cognitive impairment
  • A Quantitative Evaluation of Joint Activity and Attenuation Reconstruction in TOF PET/MR Brain Imaging
  • Generation of PET Attenuation Map for Whole-Body Time-of-Flight 18F-FDG PET/MRI Using a Deep Neural Network Trained with Simultaneously Reconstructed Activity and Attenuation Maps
  • Synthesis of Patient-Specific Transmission Data for PET Attenuation Correction for PET/MRI Neuroimaging Using a Convolutional Neural Network
  • Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI
  • Evaluation of Sinus/Edge-Corrected Zero-Echo-Time-Based Attenuation Correction in Brain PET/MRI
  • Long-Delay Arterial Spin Labeling Provides More Accurate Cerebral Blood Flow Measurements in Moyamoya Patients: A Simultaneous Positron Emission Tomography/MRI Study
  • The Effect of Susceptibility Artifacts Related to Metallic Implants on Adjacent-Lesion Assessment in Simultaneous TOF PET/MR
  • Google Scholar

More in this TOC Section

Clinical Investigations (Human)

  • The added value of 18F-FDG PET/CT compared to 68Ga-PSMA PET/CT in patients with castration-resistant prostate cancer
Show more Clinical Investigations (Human)

Physics and Instrumentation: MRI and PET/MRI

  • MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI
Show more Physics and Instrumentation: MRI and PET/MRI

Similar Articles

Keywords

  • Bone
  • MRI
  • PET
  • PET/MRI
  • FDG
  • PET/MR
  • ZTE
  • attenuation correction
  • neuroimaging
SNMMI

© 2025 SNMMI

Powered by HighWire