Visual Abstract
Abstract
CD70 is an emerging biomarker for both solid tumors and hematologic malignancies, highlighting the urgent need for a molecular imaging tracer capable of visualizing CD70 with favorable pharmacokinetics. Methods: ABDB6 was prepared by fusing the albumin-binding domain ABD035 with the CD70-targeting single-domain antibody RCCB6, which we previously reported. The resulting ABDB6 was then conjugated to the bifunctional chelator p-SCN-NOTA and labeled with 64Cu to produce [64Cu]Cu-NOTA-ABDB6. Flow cytometry was used to screen 6 lymphoma cell lines with varying CD70 expression levels. Cell uptake and in vivo immuno-PET imaging studies were conducted to fully evaluate the pharmacokinetic properties and tumor-targeting efficacy of [64Cu]Cu-NOTA-ABDB6. An ABDB6 blocking study was performed to validate the targeting specificity of [64Cu]Cu-NOTA-ABDB6, followed by immunohistochemistry and fluorescent immunostaining studies to correlate tracer uptake with CD70 expression. Results: 64Cu labeling of ABDB6 achieved a high radiochemical yield and specific activity. Significant CD70 expression was observed in 5 lymphoma cell lines (TMD8, HBL1, OCI-LY10, LCL-EBV, and type III latency Burkitt lymphoma [BL] cells) but not in type I latency BL cells, which served as the negative control. [64Cu]Cu-NOTA-ABDB6 exhibited good affinity for CD70 protein at the nanomolar level (inhibitory concentration of 50%, 91.57 nM) and specificity in binding to human CD70. Immuno-PET imaging of [64Cu]Cu-NOTA-ABDB6 demonstrated excellent tumor uptake and retention in various CD70-positive lymphoma models (TMD8, type III latency BL, and LCL-EBV), with the highest tumor uptake values recorded as 24.67 ± 1.36, 18.02 ± 4.29, and 14.68 ± 1.20 percentage injected dose per gram of tissue (%ID/g) at 48 h after injection, respectively. These tumor uptake values were significantly higher than that of the CD70-negative type I latency BL tumor, which had an uptake of 3.59 ± 0.28 %ID/g at the same scanning time point (P < 0.05). In the TMD8 blocking group, tumor uptake was 5.99 ± 1.20 %ID/g at 48 h after injection, significantly lower than in the TMD8 control group (P < 0.01). Both biodistribution and histology results corroborated these imaging findings. Conclusion: [64Cu]Cu-NOTA-ABDB6 immuno-PET effectively visualized varying levels of CD70 in different lymphoma models. Its clinical potential may provide insights into CD70 expression in lymphoma patients.
Footnotes
Published online Feb. 27, 2025.
- © 2025 by the Society of Nuclear Medicine and Molecular Imaging.
This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
SNMMI members
Login to the site using your SNMMI member credentials
Individuals
Login as an individual user