Visual Abstract
Abstract
Personalized dosimetry holds promise to improve radioembolization treatment outcomes in hepatocellular carcinoma (HCC) patients. To this end, tolerance absorbed doses for nontumor liver tissue are assessed by calculating the mean absorbed dose to the whole nontumor liver tissue (AD-WNTLT), which may be limited by its neglect of nonuniform dose distribution. Thus, we analyzed whether voxel-based dosimetry could be more accurate in predicting hepatotoxicity in HCC patients undergoing radioembolization. Methods: In total, 176 HCC patients were available for this retrospective analysis; of these, 78 underwent partial- and 98 whole-liver treatment. Posttherapeutic changes in bilirubin were graded using the Common Terminology Criteria for Adverse Events. We performed voxel-based and multicompartment dosimetry using pretherapeutic 99mTc-labeled human serum albumin SPECT and contrast-enhanced CT/MRI and defined the following dosimetry parameters: AD-WNTLT; the nontumor liver tissue volume exposed to at least 20 Gy (V20), at least 30 Gy (V30), and at least 40 Gy (V40); and the threshold absorbed dose to the 20% (AD-20) and 30% (AD-30) of nontumor liver tissue with the lowest absorbed dose. Their impact on hepatotoxicity after 6 mo was analyzed using the area under the receiver-operating-characteristic curve; thresholds were identified using the Youden index. Results: The area under the curve for prediction of posttherapeutic grade 3+ increases in bilirubin was acceptable for V20 (0.77), V30 (0.78), and V40 (0.79), whereas it was low for AD-WNTLT (0.67). The predictive value could further be increased in the subanalysis of patients with whole-liver treatment, where a good discriminatory power was found for V20 (0.80), V30 (0.82), V40 (0.84), AD-20 (0.80), and AD-30 (0.82) and an acceptable discriminatory power was found for AD-WNTLT (0.63). The accuracies of V20 (P = 0.03), V30 (P = 0.009), V40 (P = 0.004), AD-20 (P = 0.04), and AD-30 (P = 0.02) were superior to that of AD-WNTLT but did not differ significantly from each other. The respective thresholds were 78% (V30), 72% (V40), and 43 Gy (AD-30). Statistical significance was not reached for partial-liver treatment. Conclusion: Voxel-based dosimetry may more accurately predict hepatotoxicity than multicompartment dosimetry in HCC patients undergoing radioembolization, which could enable dose escalation or deescalation with the intent to optimize treatment response. Our results indicate that a V40 of 72% may be particularly useful in whole-liver treatment. However, further research is warranted to validate these results.
On the basis of an ever-growing body of evidence, radioembolization guidelines and expert consensuses increasingly recommend the use of multicompartment dosimetry, that is, treatment activity calculations based on a separate pretherapeutic assessment of mean absorbed doses to the tumor and nontumor tissue (1–4). Following these recommendations with regard to 90Y glass microspheres, the mean absorbed dose to the whole nontumor liver tissue (AD-WNTLT) should be kept below 75 Gy to minimize the risk of hepatic decompensation, although different thresholds based on baseline bilirubin have been proposed (4,5). However, when AD-WNTLT is used, nonuniform dose distribution is not considered. This could potentially be addressed by use of voxel-based dosimetry.
Three-dimensional voxel-based dosimetry evaluates the absorbed dose to each reconstructed voxel, thus taking into account dose heterogeneity and gradients in each region on a small spatial scale (3,6), which resembles absorbed dose planning models used in external-beam radiotherapy (7). However, the benefits of voxel-based activity calculation for 90Y radioembolization in hepatocellular carcinoma (HCC) have not yet been established (4). The limited spatial resolution of 99mTc-macroaggregated albumin (MAA) SPECT used for pretherapeutic assessment of dose distribution in 90Y radioembolization may not be sufficient to map the voxel-based distribution of tumor lesions because of the presence of image noise and partial-volume effects (6). However, the volume of the nontumoral liver is typically larger by an order of magnitude than lesions, potentially allowing for voxel-based dosimetry of the nontumoral liver (8). In addition, 99mTc-MAA SPECT predicts glass 90Y microsphere distribution more reliably in the nontumoral liver than in tumor lesions (3,8–10).
So far, there is no consensus on how to parametrize voxel-based dosimetry in radioembolization; however, exploratory considerations are facilitated by literature on external-beam radiation therapy and surgery. In external-beam radiation therapy, the safety threshold of the absorbed dose to the nontumor hepatic tissue ranges from 20 to 40 Gy (7,11,12), whereas in liver surgery, a remnant nontumor liver of 20% and 30% should be aimed for (13–17).
This work retrospectively investigated the prognostic impact of various voxel-based dosimetry parameters on short-term (6 mo) hepatotoxicity, compared with multicompartment dosimetry in HCC patients undergoing radioembolization with 90Y glass microspheres.
MATERIALS AND METHODS
Patients
From March 2008 to February 2021, 406 consecutive patients with HCC were screened from the radioembolization registry from our institution, and 176 were excluded because the follow-up period of their laboratory data was less than 6 mo. Of the remaining 230 patients, 3 underwent 2 radioembolization sessions to the identical target volume within 6 mo, impairing the assessment of absorbed dose distribution. Three patients underwent concurrent transarterial chemoembolization. Twenty-three patients underwent subsequent transarterial chemoembolization or radioembolization within 6 mo after the first radioembolization. In 25 patients, dosimetry calculations were not possible because of missing CT or MR images or technical issues. After exclusion of these 54 patients, 176 were finally included in this retrospective study (Fig. 1).
Of these 176 patients, 142 were male and 34 were female; the mean patient age was 67.2 y (range, 20 to 86 y). Seventy-eight patients underwent partial-liver treatment, and 98 underwent whole-liver treatment. Of the latter, 9 received a lobar injection after hemihepatectomy, making it a whole-liver treatment.
In cases of whole-liver treatment with 2 or more injections (e.g., separate injections for left and right lobes), injections were performed in 2 sessions, approximately 4–6 wk apart. The patient characteristics are summarized in Table 1. Of note, 3 patients had very limited extrahepatic metastases (adrenal grand, n = 1; lung, n = 1, abdominal wall, n = 1) (3). Seven patients had previously been treated with sorafenib and 1 patient with lenvatinib. In addition, 23 and 30 patients underwent transarterial chemoembolization or radiofrequency ablation and liver resection before radioembolization, respectively. Concerning this retrospective study, all procedures performed were approved in accordance with the ethical standards of the institutional review board of the Medical Faculty of the University Duisburg–Essen (Ethics Committee approval 13-5325BO) and with the principles of the Declaration of Helsinki and its later amendments. All patients gave written informed consent to the analysis of available data.
Treatment Algorithm
All radioembolization cases were discussed by a multidisciplinary tumor board. Digital-subtraction angiography, 99mTc-human serum albumin (HSA) planar scintigraphy, and SPECT/CT were performed for treatment planning. A mean of 151.4 MBq (range, 90–193 MBq) of 99mTc-HSA was administered into the hepatic target vessels, and image acquisition started within 2 h. Images were acquired on a Symbia T2 (Siemens Medical Solutions AG) hybrid SPECT/CT scanner using a 130- to 150-keV energy window, and a total of 64 views were acquired in step-and-shoot mode, with 15 s per view and a 2.8° angular step size. The low-dose CT was performed immediately after emission acquisition. Images were reconstructed into a 128 × 128 matrix with a cubic voxel size of 4.8 mm3 using the 3-dimensional ordered-subset expectation maximization algorithm with 8 iterations and 4 subsets and no smoothing filter. All images were corrected for scatter and attenuation.
Calculation of the lung-shunt fraction was based on the planar scintigraphy following guideline recommendations, and visceral shunting was assessed using 99mTc-HSA SPECT/CT by 2 nuclear medicine physicians as per clinical routine. Treatment activity was calculated using unicompartment dosimetry (mean perfused target volume absorbed dose, 80–150 Gy), aiming for an absorbed dose of 120 Gy (±10%) to the perfused target volume, with further adjustments being based on factors such as liver function, tumor load, 99mTc-HSA uptake, and the extent of the treated liver fraction. Treatment activity was injected while patient breathed freely in the same catheter position as for the pretherapeutic 99mTc-HSA scan. The mean duration from dose calibration to the first and second dose injections was 4.5 d (range, 1–12 d).
Dosimetry Calculation
Post hoc multicompartment and voxel-based dosimetry were performed by a board-certified nuclear medicine physician and radiologist in collaboration with a board-certified nuclear medicine physician using Mirada Simplicit90Y (Mirada Medical). The mean durations between the first radioembolization and the 99mTc-HSA SPECT and between the 99mTc-HSA SPECT and contrast-enhanced CT/MRI were 40.9 and 19.6 d, respectively.
After manual coregistration of contrast-enhanced CT/MR and 99mTc-HSA SPECT/CT images, segmentation of whole-liver volume, perfused target volumes, tumor tissue, and nontumor liver tissue was performed both manually and automatically or semiautomatically by use of region-growing and thresholding tools. The whole-liver volume segmentation was performed automatically, whereas tumor lesions were segmented on CT/MR images using region-growing tools and on 99mTc-HSA SPECT images using visually determined thresholds.
As for dosimetry calculation, we calculated the AD-WNTLT (multicompartment dosimetry) and determined the volume of nontumor liver tissue (voxel-based dosimetry), in which the absorbed doses exceeded 20 Gy (V20), 30 Gy (V30), and 40 Gy (V40). In addition, we determined the absorbed dose threshold level (voxel-based dosimetry) including a volume of 20% (AD-20) and 30% (AD-30) of the total nontumor liver tissue receiving the lowest absorbed doses; that is, 20% of the nontumor liver tissue received less than AD-20 and 30% of the nontumor liver tissue received less than AD-30. The analyses were limited to AD-20, AD-30, V20, V30, and V40 to prevent spurious results and multiple testing problems. The hepatic reserve, that is, the fraction of liver tissue not treated by radioembolization, was measured for all patients undergoing partial-liver treatment, and the percentage of hepatic tumor burden was obtained by dividing the tumor volume by the whole-liver volume as measured on contrast-enhanced CT/MRI.
Follow-up
The patients who underwent radioembolization were followed up using total bilirubin measurements for at least 6 mo (n = 176). Adverse effects were graded using the Common Terminology Criteria for Adverse Events (CTCAE), version 5. Relevant hepatotoxicity was defined as a binary metric by the occurrence of grade 3+ toxicity in bilirubin levels, on the basis of prior publications identifying it as a particularly suitable marker for hepatotoxicity after radioembolization (18,19).
Statistical Analysis
Statistics were analyzed using MedCalc, version 20.113-32 bit (MedCalc Software). To investigate the relationship between the absorbed dose of the nontumor liver and the liver toxicity within the follow-up period of 6 mo, we performed a receiver-operating-characteristic (ROC) curve analysis and identified the cutoffs using the Youden index. ROC curve analyses were compared using Hanley and McNeil’s methodology (20). Subanalyses were performed for patients undergoing partial-liver and whole-liver treatment; analyses of the latter group involved 9 patients undergoing lobar treatment after contralateral hemihepatectomy. A P value of less than 0.05 was considered statistically significant.
RESULTS
The mean volume and percentage of hepatic tumor burden across all patients were 269.0 mL (range, 0.6–2,534.4 mL) and 12.1% (range, 0.04%–61.1%), respectively. Twenty-nine patients had a high tumor burden (≥25%), and 147 patients had a low tumor burden (<25%). Of the 55 patients with portal tumoral thrombosis, 46 had the first branch or a more distal branch of the portal vein involved, and in 9 patients the main trunk of the portal vein was involved.
In the total cohort (n = 176), CTCAE grade 3+ hyperbilirubinemia was observed in 20 patients. Mean V20, V30, V40, AD-20, AD-30, and AD-WNTLT was 60.5%, 55.6%, 51.1%, 11.1 Gy, 18.2 Gy, and 57.7 Gy, respectively. Comparison of ROC curves (Fig. 2) showed superiority of V20 (area under the ROC curve [AUC], 0.77; P = 0.03), V30 (AUC, 0.78; P = 0.009), and V40 (AUC, 0.79; P = 0.005) over AD-WNTLT (AUC, 0.67) in predicting 6-mo hepatotoxicity. V40 was significantly more accurate than V20 (P < 0.05), whereas no difference was found between V40 and V30 (P = 0.09). The cutoffs using the Youden index with the follow-up period of 6 mo, in consideration of the ROC analyses in CTCAE grade 3+ hyperbilirubinemia (Table 2; Figs. 2 and 3), were 56.9 Gy, 80%, 78%, 68%, 27 Gy, and 37 Gy in AD-WNTLT, V20, V30, V40, AD-20, and AD-30, respectively.
In the cohort that underwent partial-liver treatment (n = 78), CTCAE grade 3+ hyperbilirubinemia was observed in 4 patients. Mean V20, V30, V40, AD-20, AD-30, AD-WNTLT, and hepatic reserve were 42.7%, 39.7%, 36.9%, 0.1 Gy, 1.4 Gy, 42.1 Gy, and 41.8%, respectively. The AUC of the voxel-based calculations ranged from 0.52 to 0.59 for voxel-based analyses and was 0.58 for AD-WNTLT; however, statistical significance was reached only for AD-30 (P < 0.001). The cutoffs using the Youden index with the follow-up period of 6 mo, in consideration of the ROC analyses in CTCAE grade 3+ hyperbilirubinemia (Table 3; Fig. 4; Supplemental Fig. 1; supplemental materials are available at http://jnm.snmjournals.org), were 58.7 Gy, 6%, 6%, 5%, 0 Gy, 0 Gy, and 34% in AD-WNTLT, V20, V30, V40, AD-20, AD-30, and hepatic reserve, respectively.
In the cohort that underwent whole-liver treatment (n = 98), CTCAE grade 3+ hyperbilirubinemia was observed in 16 of 98 within 6 mo and in 2 of 49 within 6–12 mo. Mean V20, V30, V40, AD-20, AD-30, and AD-WNTLT were 74.6%, 68.3%, 62.3%, 19.9 Gy, 31.6 Gy, and 70.2 Gy, respectively. The AUC of the voxel-based calculations using histograms (V20, V30, V40, AD-20, and AD-30) (AUC, 0.80–0.84) were superior to that of the AD-WNTLT (AUC, 0.63) (Table 4; Figs. 5 and 6). V20 (P = 0.03), V30 (P = 0.009), V40 (P = 0.004), AD-20 (P = 0.04), and AD-30 (P = 0.02) were superior to AD-WNTLT in predicting hepatotoxicity, whereas the predictive power between them did not differ significantly. The cutoffs were determined to be 55.6 Gy, 80%, 78%, 72%, 27 Gy, and 43 Gy in AD-WNTLT, V20, V30, V40, AD-20, and AD-30, respectively.
DISCUSSION
Our results indicate superiority for voxel-based dosimetry in the pretherapeutic prediction of hepatotoxicity in HCC patients undergoing radioembolization of the whole liver. All tested voxel-based parameters were more accurate in predicting 6-mo hepatotoxicity than AD-WNTLT, which is considered the state of the art by current guidelines (3,4). A V40 of more than 72%, in particular, appears to be an accurate predictor of liver decompensation, showing an accuracy superior to V20, AD-20, AD-30, and AD-WNTLT and a tendency toward higher accuracy than V30.
Of all patients undergoing whole-liver treatment, grade 3+ hepatotoxicity was observed in only 3 of 98 patients with a V40 of no more than 72%, making it a reasonably safe threshold for radioembolization. On the basis of these results, activity escalation within safe margins would have been possible in 65 of 98 patients with a V40 of less than 72% undergoing whole-liver radioembolization. Because prior studies assessing the absorbed dose–response relationship for HCC lesions treated with radioembolization show a wide range of proposed absorbed dose thresholds, it follows that additional increases in tumor-absorbed doses may further increase the likelihood of treatment response (19,21,22).
Treatment planning using absorbed dose to the nontumor liver tissue as an additional driving criterion may be of particular interest in the presence of small tumor lesions, where partial-volume effects are expected to lead to a severe underestimation of absorbed doses. Furthermore, the prediction of absorbed doses to nontumor liver tissue by use of 99mTc-MAA has been shown to be more reliable than the prediction of absorbed doses to tumor lesions, underpinning the robustness of this approach (9,10).
To our knowledge, this is the first study to show superiority for voxel-based dosimetry over multicompartment dosimetry in the prediction of liver decompensation of HCC patients undergoing radioembolization with 90Y glass microspheres. However, prior studies have shown some evidence for a potential benefit of voxel-based dosimetry to assess the likelihood of treatment response. Two retrospective studies of patients with liver tumors showed that voxel-based dosimetry of tumor lesions as assessed on posttherapeutic PET was predictive of tumor response after radioembolization with 90Y resin microspheres (23,24). Similarly, a slightly higher accuracy than for multicompartment dosimetry was found for response prediction using voxel-based segmentation of the pretherapeutic 99mTc-MAA SPECT/CT images (25).
The analysis of prognostic parameters of hepatotoxicity in HCC patients undergoing partial-liver treatment did not reveal statistically significant results. This may be attributable to low statistical power because of a low event rate in this subcohort. In addition, the prognostic impact of the voxel-based parameters chosen for this study may not be able to accurately reflect radiobiologic effects in a patient cohort, in whom a relevant part of the liver remains untreated.
Limitations of this study include the high rate of patients with insufficient follow-up, as well as its retrospective nature. In addition, absorbed dose distribution was derived from pretherapeutic 99mTc-HSA SPECT/CT, which has been shown to be a reliable but not perfect predictor of 90Y glass microsphere deposition (9,10). Calculated doses will therefore deviate from those achieved during treatment, posing inherent constraints on the reliability of 99mTc-MAA/HSA-based pretherapeutic prediction of liver decompensation. On the other hand, 99mTc-MAA/HSA SPECT/CT constitutes the only modality to pretherapeutically assess 90Y microsphere deposition recommended by current guidelines, with no viable alternatives. In addition, for sequential bilobar radioembolization, absorbed doses from both sessions were analyzed cumulatively, with no interim 99mTc-MAA/HSA SPECT/CT or contrast-enhanced CT, meaning that volumetric changes between treatments were not considered. Though technically a limitation with regard to accurate assessment of dose distribution, this more closely resembles the clinical reality of most physicians and is therefore preferable. The interval from the 99mTc-MAA/HSA SPECT/CT scan to the first radioembolization (40.9 d) was longer than ideal (15 d) (3) and may limit the reliability of the predicted dose distribution.
CONCLUSION
Our retrospective study showed encouraging results for the prediction of posttherapeutic liver decompensation in HCC patients after whole-liver radioembolization with 90Y glass microspheres using voxel-based absorbed dose metrics. In these patients, exposure of 72% or more of the nontumor liver tissue to more than 40 Gy was associated with an increased risk of liver decompensation. Future research is warranted to confirm these preliminary results and elucidate the interplay of dosimetry results and baseline laboratory and clinical parameters.
DISCLOSURE
Benedikt M. Schaarschmidt received a research grant from PharmaCept for an undergoing investigator-initiated study not related to this paper. Wolfgang P. Fendler is a consultant for Endocyte and BTG and received fees from RadioMedix, Bayer, and Parexel outside the submitted work. Wolfgang P. Fendler reports fees from SOFIE Bioscience (research funding), Janssen (consultant, speakers’ bureau), Calyx (consultant), Bayer (consultant, speakers’ bureau, research funding), Parexel (image review), and AAA (speakers’ bureau) outside the submitted work. Ken Herrmann reports personal fees from Bayer, Sofie Biosciences, SIRTEX, Adacap, Curium, Endocyte, BTG, IPSEN, Siemens Healthineers, GE Healthcare, Amgen, Novartis, ymabs, Aktis Oncology, Theragnostics, and Pharma15; other fees from Sofie Biosciences; nonfinancial support from ABX; and grants from BTG outside the submitted work. Manuel Weber reports personal fees from Boston Scientific, Terumo, Advanced Accelerator Applications, and Eli Lilly outside the submitted work. No other potential conflict of interest relevant to this article was reported.
KEY POINTS
QUESTION: Can voxel-based dosimetry predict hepatotoxicity in HCC patients undergoing radioembolization and thereby improve pretherapeutic activity calculation?
PERTINENT FINDINGS: Voxel-based dosimetry may more accurately predict hepatotoxicity than multicompartment dosimetry, which is currently considered to be the state of the art in procedure guidelines.
IMPLICATIONS FOR PATIENT CARE: Voxel-based dosimetry of selective internal radiation therapy is helpful to assess expected hepatotoxicity and may thereby enable safe escalation or deescalation of treatment activity to optimize tumor control, that is, the efficacy and toxicity trade-off of selective internal radiation therapy.