Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigation
Open Access

Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging

Matthew G. Spangler-Bickell, Samuel A. Hurley, Ali Pirasteh, Scott B. Perlman, Timothy Deller and Alan B. McMillan
Journal of Nuclear Medicine October 2022, 63 (10) 1604-1610; DOI: https://doi.org/10.2967/jnumed.121.263309
Matthew G. Spangler-Bickell
1PET/MR Engineering, GE Healthcare, Waukesha, Wisconsin;
2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Samuel A. Hurley
2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ali Pirasteh
2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
3Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Scott B. Perlman
2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timothy Deller
1PET/MR Engineering, GE Healthcare, Waukesha, Wisconsin;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alan B. McMillan
2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
3Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 63 no. 10 1604-1610
DOI 
https://doi.org/10.2967/jnumed.121.263309
PubMed 
35086896

Published By 
Society of Nuclear Medicine
Print ISSN 
0161-5505
Online ISSN 
2159-662X
History 
  • Received for publication October 1, 2021
  • Accepted for publication January 25, 2022
  • Published online October 3, 2022.

Article Versions

  • previous version (January 27, 2022 - 13:16).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2022 by the Society of Nuclear Medicine and Molecular Imaging. Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: https://jnm.snmjournals.org/page/permissions.

Author Information

  1. Matthew G. Spangler-Bickell1,2,
  2. Samuel A. Hurley2,
  3. Ali Pirasteh2,3,
  4. Scott B. Perlman2,
  5. Timothy Deller1 and
  6. Alan B. McMillan2,3
  1. 1PET/MR Engineering, GE Healthcare, Waukesha, Wisconsin;
  2. 2Radiology, University of Wisconsin–Madison, Madison, Wisconsin; and
  3. 3Medical Physics, University of Wisconsin–Madison, Madison, Wisconsin
  1. For correspondence or reprints, contact Matthew G. Spangler-Bickell (matthew.spangler-bickell{at}ge.com).
View Full Text

Statistics from Altmetric.com

Cited By...

  • 16 Citations
  • 15 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Total-Body Positron Emission Tomography
    Simon R. Cherry, Johanna Diekmann, Frank M. Bengel
    JACC: Cardiovascular Imaging 2023 16 10
  • Markerless head motion tracking and event-by-event correction in brain PET
    Tianyi Zeng, Yihuan Lu, Weize Jiang, Jiaxu Zheng, Jiazhen Zhang, Paul Gravel, Qianqian Wan, Kathryn Fontaine, Tim Mulnix, Yulin Jiang, Zhaohui Yang, Enette Mae Revilla, Mika Naganawa, Takuya Toyonaga, Shannan Henry, Xinyue Zhang, Tuoyu Cao, Lingzhi Hu, Richard E Carson
    Physics in Medicine & Biology 2023 68 24
  • Clinical Value of Hybrid PET/MR Imaging
    Aurélie Kas, Laura Rozenblum, Nadya Pyatigorskaya
    Magnetic Resonance Imaging Clinics of North America 2023 31 4
  • Impact of motion correction on [18F]-MK6240 tau PET imaging
    Amal Tiss, Thibault Marin, Yanis Chemli, Matthew Spangler-Bickell, Kuang Gong, Cristina Lois, Yoann Petibon, Vanessa Landes, Kira Grogg, Marc Normandin, Alex Becker, Emma Thibault, Keith Johnson, Georges El Fakhri, Jinsong Ouyang
    Physics in Medicine & Biology 2023 68 10
  • Motion-correction strategies for enhancing whole-body PET imaging
    James Wang, Dalton Bermudez, Weijie Chen, Divya Durgavarjhula, Caitlin Randell, Meltem Uyanik, Alan McMillan
    Frontiers in Nuclear Medicine 2024 4
  • Deep-Learning-Aided Intraframe Motion Correction for Low-Count Dynamic Brain PET
    Erik Reimers, Ju-Chieh Cheng, Vesna Sossi
    IEEE Transactions on Radiation and Plasma Medical Sciences 2024 8 1
  • Current Applications of PET/MR: Part I: Technical Basics and Preclinical/Clinical Applications
    Seyed Ali Mirshahvalad, Adam Farag, Jonathan Thiessen, Rebecca Wong, Patrick Veit-Haibach
    Canadian Association of Radiologists Journal 2024 75 4
  • Impact of upgrading from a 25-cm to a 30-cm z-axis field of view digital PET/CT in a pediatric hospital
    Joseph G. Meier, Andrew T. Trout, Nadeen Abu Ata, Susan E. Sharp, Christopher G. Anton, Elanchezhian Somasundaram, Samuel L. Brady
    Pediatric Radiology 2024 54 11
  • Improving diagnostic precision in amyloid brain PET imaging through data-driven motion correction
    Hye Lim Park, Sonya Youngju Park, Mingeon Kim, Soyeon Paeng, Eun Jeong Min, Inki Hong, Judson Jones, Eun Ji Han
    EJNMMI Physics 2024 11 1
  • Recent advances in combined Positron Emission Tomography and Magnetic Resonance Imaging
    P. Galve, B. Rodriguez-Vila, J.L. Herraiz, V. García-Vázquez, N. Malpica, J.M. Udias, A. Torrado-Carvajal
    Journal of Instrumentation 2024 19 01

Article usage

Article usage: January 2022 to April 2025

AbstractFullPdf
Jan 2022385059
Feb 20226460131
Mar 2022234047
Apr 2022199036
May 2022135032
Jun 2022107048
Jul 2022117020
Aug 2022105024
Sep 202299033
Oct 2022363380123
Nov 202212412757
Dec 20226940341
Jan 20236139849
Feb 20234836844
Mar 20234338352
Apr 20232529837
May 20231822214
Jun 20232523619
Jul 20233318420
Aug 20232331427
Sep 20232022418
Oct 20231514130
Nov 20231515919
Dec 202356519
Jan 20241617527
Feb 20241120710
Mar 20242412049
Apr 2024436531
May 2024328622
Jun 2024527527
Jul 202410312834
Aug 202484115118
Sep 2024183230
Oct 2024154831
Nov 2024266429
Dec 2024155045
Jan 2025134018
Feb 2025126525
Mar 202587336
Apr 20251710754
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 63 (10)
Journal of Nuclear Medicine
Vol. 63, Issue 10
October 1, 2022
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging
Matthew G. Spangler-Bickell, Samuel A. Hurley, Ali Pirasteh, Scott B. Perlman, Timothy Deller, Alan B. McMillan
Journal of Nuclear Medicine Oct 2022, 63 (10) 1604-1610; DOI: 10.2967/jnumed.121.263309

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging
Matthew G. Spangler-Bickell, Samuel A. Hurley, Ali Pirasteh, Scott B. Perlman, Timothy Deller, Alan B. McMillan
Journal of Nuclear Medicine Oct 2022, 63 (10) 1604-1610; DOI: 10.2967/jnumed.121.263309
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction
  • Google Scholar

More in this TOC Section

  • Establishing In Vitro Dosimetric Models and Dose–Effect Relationships for 177Lu-DOTATATE in Neuroendocrine Tumors
  • Designed Ankyrin Repeat Protein–Mediated Peptide Nucleic Acid–Based Pretargeting: A Proof-of-Principle Study
  • [11C]ZTP-1: An Effective Short-Lived Radioligand for PET of Rat and Monkey Brain Phosphodiesterase Type 4 Subtype B
Show more Basic Science Investigation

Similar Articles

Keywords

  • PET
  • Image Reconstruction
  • data-driven motion correction
  • brain imaging
SNMMI

© 2025 SNMMI

Powered by HighWire