Visual Abstract
Abstract
With hundreds of millions of coronavirus disease 2019 (COVID-19) messenger RNA (mRNA)–based vaccine doses planned to be delivered worldwide in the upcoming months, it is important to recognize PET/CT findings in recently vaccinated immunocompetent or immunocompromised patients. We aimed to assess PET/CT uptake in the deltoid muscle and axillary lymph nodes of patients who received a COVID-19 mRNA-based vaccine and to evaluate its association with patient age and immune status. Methods: All consecutive adults who underwent PET/CT scans with any radiotracer at our center during the first month of a national COVID-19 vaccination rollout (between December 23, 2020, and January 27, 2021) and had received the vaccination were included. Data on clinical status, laterality, and time from vaccination were prospectively collected, retrospectively analyzed, and correlated with deltoid muscle and axillary lymph node uptake. Results: Of 426 eligible subjects (median age, 67 ± 12 y; 49% female), 377 (88%) underwent PET/CT with 18F-FDG, and positive axillary lymph node uptake was seen in 45% of them. Multivariate logistic regression analysis revealed a strong inverse association between positive 18F-FDG uptake in ipsilateral lymph nodes and patient age (odds ratio [OR], 0.57; 95% CI, 0.45–0.72; P < 0.001), immunosuppressive treatment (OR, 0.37; 95% CI, 0.20–0.64; P = 0.003), and presence of hematologic disease (OR, 0.44; 95% CI, 0.24–0.8; P = 0.021). No such association was found for deltoid muscle uptake. The number of days from the last vaccination and the number of vaccine doses were also significantly associated with increased odds of positive lymph node uptake. Conclusion: After mRNA-based COVID-19 vaccination, a high proportion of patients showed ipsilateral lymph node axillary uptake, which was more common in immunocompetent patients. This information will help with the recognition of PET/CT pitfalls and may hint about the patient’s immune response to the vaccine.
The emergence of pneumonia cases caused by the novel severe acute respiratory syndrome coronavirus 2 in December 2019 (1) and the subsequent coronavirus disease 2019 (COVID-19) pandemic have led to initiatives for developing an effective vaccine from as early as January 2020. To date, more than 230 vaccine candidates have been developed (2), many of them using innovative vaccine development technologies, most of which had never been used commercially in humans before (3).
The first vaccines to be approved by the U.S. Food and Drug Administration, in December 2020, were based on a messenger RNA (mRNA) sequence encoding segments of the spike protein of the severe acute respiratory syndrome coronavirus 2 and encapsulated in lipid nanoparticles (4,5).
To date, there are no published data regarding the efficacy of mRNA vaccines in immunocompromised populations, and both the U.S. Centers for Disease Control and Prevention and the U.S. Food and Drug Administration state that immunocompromised persons receiving mRNA vaccines may have a diminished immune response (4–6).
As the global COVID-19 vaccination endeavor is in its early days, there are no published data on the prevalence of post–mRNA vaccination PET/CT findings, especially in oncologic patients, either immunocompetent or immunocompromised. The most common findings described in patients who underwent PET/CT after receiving vaccines against influenza or papillomavirus were ipsilateral lymphadenopathy with varying degrees of uptake (7–15).
In this study, we aimed to describe the PET/CT findings in patients after mRNA-based COVID-19 vaccination and to identify the patient characteristics associated with PET/CT uptake.
MATERIALS AND METHODS
Study Design and Setting
We conducted a retrospective analysis of prospectively collected data. The study was approved by the institutional ethics committee. The need for patient informed consent was waived.
Patients
All consecutive adults (>18 y old) who had been referred for a PET/CT scan (with any radiotracer) for any indication between December 23, 2020 (the initiation date of a national COVID-19 vaccination rollout in the general population), and January 27, 2021, and had received the vaccination were included in the study. Patients were excluded if they had incomplete medical records or a known malignancy involving axillary lymph nodes.
Data Collection
Before entering the PET/CT unit, all patients were asked to complete a standard clinical intake form, which included age, sex, indication for PET/CT, clinical and oncologic status, current oncologic treatment, recent surgical procedures (including location of the procedure), date of COVID-19 vaccination, and arm in which the vaccine was administered for the first and second (if applicable) doses.
Immunosuppressive status was assigned to patients with a known hematologic disease (any type of lymphoma, leukemia, or multiple myeloma) or receiving any of the following treatments considered to result in immunosuppression: current corticosteroid therapy, chemotherapy within the last 3 mo, treatment with rituximab or daratumumab in the last 6 mo, or bone marrow transplantation within the last 6 mo (16).
PET/CT Acquisition and Analysis
All PET/CT scans were performed according to our institute’s clinical scanning protocols. A diagnostic CT examination was performed on a 64-detector-row helical CT scanner (Vereos; Philips). The field of view and pixel size for PET images reconstructed for fusion were 57.6 cm and 4 mm, respectively, with a matrix size of 144 × 144. The technical parameters used for CT imaging were a pitch of 0.83, a gantry rotation speed of 0.5 s/rotation, 120 kVp, a modulated tube current of 40–300 mA, and specific breath-holding instructions. After fasting for 2–6 h, the patients received an intravenous injection of tracer: 5.18 MBq/kg for 18F-FDG or 18F-fluorodopa (18F-DOPA), 3.7 MBq/kg for 18F-prostate-specific membrane antigen (18F-PSMA), and 185–296 MBq for 68Ga-PSMA or 68Ga-DOTATATE. About 60 min after tracer administration, CT images were obtained from the vertex to the mid thigh or of the whole body. An emission PET scan followed in 3-dimensional acquisition mode for the same longitudinal coverage, 1.5 min per bed position. CT images were fused with the PET data and used to generate a map for attenuation correction, eventually generating reconstructed images for review on a computer workstation.
The images were analyzed using Vue PACS (version 12.1.5.1; Carestream). All PET/CT images were read in consensus by a physician with dual board certification in radiology and nuclear medicine and 6 y of PET/CT reading experience, 2 board-certified radiologists in nuclear medicine residency with 3 y of PET/CT experience, and a nuclear medicine resident with 1 y of PET/CT experience.
Deltoid muscle and axillary lymph node SUVmax, normalized for body weight, was measured by placing a region of interest at the injection site and at the draining axillary lymph node with the highest uptake (i.e., the ipsilateral side), as well as on the contralateral deltoid muscle and axillary lymph node (i.e., the contralateral side), which were used as a reference.
Because SUVmax depends on the tracer used and on variable technical aspects, uptake in the deltoid muscle and axillary lymph node was defined as positive if the ipsilateral-to-contralateral SUVmax ratio was at least 1.5, a method previously used by Thomassen et al. (9).
Statistical Analysis
Logistic regression models were fit with a binary dependent variable (positive deltoid muscle or axillary lymph node uptake [yes/no]) and with the following independent variables: scaled age, sex, immunosuppressive treatment (yes/no), hematologic disease (yes/no), scaled days since last vaccine dose, whether a second vaccine dose was administered (yes/no), and the interaction between the last 2 independent variables. The test of Hosmer and Lemeshow (17) with 8 groups (representing the number of covariates plus 1) was used for assessing the goodness of fit of each model. The Benjamini and Hochberg false-discovery rate method (18) was used for multiple-testing adjustment, jointly, for the 2 models, at the level of 0.05. All statistical analyses were conducted in the R environment (https://www.r-project.org/). Because of small number of non–18F-FDG scans, only 18F-FDG scans were included in the statistical analysis.
RESULTS
Of 1,002 consecutive adults scanned during the study, 44% (443) received at least 1 vaccine dose before the scan. Of those vaccinated, 23% (103/443) received the second vaccine dose. After excluding patients with incomplete medical records or with a known malignancy involving the axillary lymph nodes, the final vaccinated study cohort comprised 426 patients with a mean age of 67 y (SD, 12), each with a single PET/CT scan (Fig. 1). Patient demographics are shown in Table 1. Most patients (377/426, 88%) underwent 18F-FDG scans. 18F-PSMA and 68Ga-PSMA scans were performed on 37 patients (9%), 68Ga-DOTATATE scans on 11 patients (2.5%), and an 18F-DOPA scan on 1 patient (0.5%). Among those who underwent 18F-FDG PET/CT, 20% (76/377) received a second vaccine dose, 62% (232/377) were immunocompetent, and 38% (145/377) were immunocompromised. Among the immunocompromised patients, 52% (75/145) had a hematologic malignancy and 56% (82/145) received immunosuppressive therapy. There was an overlap between these 2 groups, as 12 hematologic patients also received immunosuppressive treatment.
Patient flowchart.
Demographic Characteristics of Vaccinated Study Population
The time between the first vaccine dose and the PET/CT scan ranged between 1 and 34 d (median, 13 d). The median time between the last vaccination dose and the PET/CT scan was 11 d (SD, ± 6.4) for patients who received only 1 vaccine dose and 4 d (SD, ± 3.8) for patients who received a second vaccine dose. Although the overall time frame between vaccination and imaging was large (1–34 d), the distribution was similar between the immunocompromised and immunocompetent groups (interquartile ranges, 6–21 and 6–20, respectively).
Although positive 18F-FDG and 68Ga-DOTATATE axillary lymph node uptake was noted in about half the patients, 18F-PSMA, 68Ga-PSMA, and 18F-DOPA uptake was far less common (Table 2; Figs. 2 and 3). The mean 18F-FDG SUVmax in patients with positive uptake was 2 ± 0.8 (range, 0.6–4.6) and 2.7 ± 1.6 (range, 0.6–12.4) in the deltoid muscle and axillary lymph nodes, respectively.
Prevalence of Increased Uptake in Ipsilateral Deltoid Muscle or in Ipsilateral Axillary Lymph Nodes with Different PET/CT Tracers
18F-FDG PET/CT after COVID-19 vaccination in 66-y-old woman with suspected colon cancer and elevated carcinoembryonic antigen, with no current immunosuppressive treatment: maximal-intensity projection (A), axial multiplanar reformation (B), contrast-enhanced CT (C), and PET/CT (D) 25 d after first vaccine dose and 2 d after second vaccine dose, both in left arm. Increased uptake was observed in left deltoid muscle (arrowhead), corresponding to injection site, and in ipsilateral enlarged axillary lymph nodes (arrows). Otherwise, there were no hypermetabolic findings suggestive of malignancy.
68Ga-DOTATATE PET/CT after COVID-19 vaccination in 68-y-old woman with newly diagnosed typical carcinoid (G2), not currently receiving immunosuppressive treatment: maximal-intensity projection (A), axial multiplanar reformation (B), contrast-enhanced CT (C), and PET/CT (D) 24 d after first vaccine and 3 d after second vaccine, both on left side. Increased uptake was observed in left deltoid muscle (arrowhead), corresponding to injection site, and in left axillary lymph nodes of normal size (arrows).
A little over half the immunocompetent patients (122/232, 53%) and a third of the immunocompromised patients (48/145, 33%) showed 18F-FDG axillary lymph node uptake. More specifically, 18F-FDG axillary lymph node uptake was observed in 30% (25/82) of patients treated with immunosuppressive treatment and 32% (24/75) of patients with a hematologic disease.
The multivariate logistic regression analysis of SUV uptake in the deltoid muscle and the lymph nodes after COVID-19 vaccination is summarized in Table 3. There was a strong inverse association between positive 18F-FDG uptake in ipsilateral lymph nodes and patient age (odds ratio [OR], 0.57; 95% CI, 0.45–0.72; P < 0.001), immunosuppressive treatment (OR, 0.37; 95% CI, 0.20–0.64; P = 0.003), and presence of hematologic disease (OR, 0.44; 95% CI, 0.24–0.8; P = 0.021). In addition, the number of days from the last vaccine dose and the number of vaccine doses were significantly associated with increased odds of positive lymph node uptake (OR, 1.53; 95% CI, 1.18–1.99[P = 0.005], and OR, 7.53; 95% CI, 2.91–23.50 [P = 0.001], respectively). No association was found between positive deltoid muscle uptake and patient age (OR, 0.86; 95% CI, 0.66–1.12; P = 0.32), immunosuppressive treatment (OR, 0.63; 95% CI, 0.31–1.23; P = 0.277), or hematologic disease (OR, 0.72; 95% CI, 0.34–1.42; P = 0.411). The number of vaccine doses was also associated with increased odds for positive deltoid muscle uptake (OR, 2.85; 95%CI, 1.13–6.70; P = 0.040), whereas the interaction between the number of vaccine doses and the number of days from the last vaccination was associated with decreased odds of positive deltoid muscle uptake (OR, 0.28; 95%CI, 0.09–0.75; P = 0.036).
Multivariate Logistic Regression Analysis of Uptake in Deltoid Muscle and Lymph Nodes After COVID-19 mRNA Vaccination
A single patient presenting for staging of left-breast cancer after 2 doses of vaccine (first dose in left arm and second dose in right arm) had 18F-FDG–avid lymphadenopathy in the left axilla, but a further biopsy negated lymph node involvement (Fig. 4).
Pathology of reactive, 18F-FDG–avid, axillary lymph node after COVID-19 vaccination in 41-y-old woman with newly diagnosed left-sided estrogen receptor–positive, progesterone receptor–positive, human epidermal growth factor receptor 2–positive breast cancer: maximal-intensity projection showing marked increase in 18F-FDG uptake in right deltoid muscle (arrowhead), corresponding to recent second vaccine dose site, and in several left and right axillary lymph nodes (A); axial multiplanar reformation (B); contrast-enhanced CT (C); and PET/CT showing marked bilateral increase in 18F-FDG uptake in axillary lymph nodes (arrows) (D). First vaccine dose was in left deltoid muscle before diagnosis of breast cancer and 22 d before scan. Second vaccine dose was in right deltoid muscle after diagnosis and 1 d before scan. Patient underwent ultrasound-guided core-needle biopsy to left suggestive axillary lymph node 1 d after PET/CT scan. (E) Hematoxylin- and eosin-stained images of cores of lymph node tissue showing prominently dilated and edematous sinuses that probably reflect reactive changes. Lymphoid tissue is unremarkable, and there is no evidence of malignancy.
DISCUSSION
With the global vaccination effort against COVID-19 under way, data on the safety and efficacy of the newly approved vaccines are accumulating (19). In the current study, 45% of patients demonstrated avid ipsilateral axillary lymphadenopathy on 18F-FDG PET/CT in the weeks after vaccination with the novel mRNA-based COVID-19 vaccine, a finding significantly less common in immunocompromised patients. During Pfizer’s phase 3 vaccine approval trial, only 0.3% of vaccinated participants were diagnosed with ipsilateral lymphadenopathy (4), suggesting that most lymph node uptake occurs in subclinical lymphadenopathy.
In our patient population, we encountered 426 patients who, over a short period of 5 wk, had received an mRNA vaccination for COVID-19 and undergone PET/CT (44% of all patients scanned). It soon became apparent that on many of those scans, the ipsilateral deltoid muscle and axillary lymph node showed avid uptake that was not related to the underlying disease (20).
Previous studies have explored the association between aging or immune status and vaccine-induced protection. Such studies showed impaired primary and secondary antibody responses to vaccination in the elderly (21), low vaccine-induced protection against influenza A (H1N1) in patients receiving anti-CD20 treatment with rituximab (22), and a weaker antibody response to influenza virus vaccine in patients receiving cancer chemotherapy (23). A previous study failed to show an association between 18F-FDG axillary lymph node uptake and chemotherapy in patients vaccinated against influenza virus (8). Our study demonstrated that in the weeks after injection of the novel mRNA-based vaccine, the 18F-FDG PET/CT images of 53% of immunocompetent patients showed avid ipsilateral axillary lymphadenopathy, a finding that was less common in immunocompromised patients (33%). Furthermore, we found a strong inverse association between axillary lymph node uptake, patient age, and immune status, as well as a strong association between the number of administered vaccine doses (the odds of positive lymph node uptake were higher in patients receiving 2 vaccine doses) and the time since the last vaccination (the longer the interval, the higher the odds of positive lymph node uptake). Conversely, no association was found between deltoid muscle uptake and age or immune status. Deltoid muscle uptake was associated with only the interval from the second vaccine dose and the number of administered vaccine doses (taking into account that the median time before the PET/CT scan was shorter for the second vaccine dose [4 d] than for the first vaccine dose [11 d]). These associations imply that the high metabolic activity in the lymph nodes might be a marker of vaccine-induced immune system activation, increasing over time and after the second vaccine dose, whereas metabolic activity in the deltoid muscle is inflammatory and likely secondary to local trauma from the injection itself. Whether there is a causal association between axillary lymph node uptake and vaccination-elicited immunogenicity should be further explored.
Our study had a few limitations. First, all patients were vaccinated with the Pfizer-BioNTech COVID-19 vaccine. It is yet unknown whether similar PET/CT findings would be observed after administration of other manufacturers’ mRNA vaccines and whether other vaccine platforms (e.g., viral vectors) would elicit similar uptake on PET/CT. Second, the method used to define patients as immunocompetent versus immunocompromised may have resulted in misclassification of some patients, as we did not account for some conditions requiring immunosuppressive therapy, such as posttransplantation or rheumatologic diseases; however, we assume that their relative proportion in the study cohort was low. Third, as most of the patients underwent 18F-FDG PET/CT, the small number of patients undergoing imaging with other tracers (68Ga-DOTATATE, PSMA, and 18F-DOPA) was not included in the statistical regression model, and more data are required to assess these tracers. Last, the study was conducted during a short period (37 d), and we did not have a repeat scan of the same patients. Although our data show that 18F-FDG uptake may be observed long after the first vaccine dose (up to 34 d), we have no data on its trend and change over longer periods. These data could be collected in future studies.
Elderly and high-risk patients are more prone to developing malignancies. Because many countries choose to vaccinate these populations first, and because hundreds of millions of COVID-19 vaccine doses were planned to be administered by the summer of 2021 (24), the PET/CT findings we describe here will likely be seen more often. Recognition of reactive axillary lymph node uptake as an indication of prior mRNA vaccination will obviate unnecessary oncologic patient work-up.
CONCLUSION
In about half the patients receiving the novel mRNA-based COVID-19 vaccine, PET/CT showed avid ipsilateral lymphadenopathy, which was significantly less common in immunocompromised and elderly patients. These findings suggest that 18F-FDG PET/CT may hint about the patient’s immune response to the vaccine. In addition, these findings will help inform nuclear medicine physicians about potential PET/CT pitfalls related to COVID-19 vaccination—pitfalls possibly requiring a dedicated intake form addressing recent COVID-19 vaccination. Lastly, these findings may help oncologic physicians in deciding the proper work-up, such as recommending that breast cancer patients be vaccinated on their healthy side to avoid unnecessary biopsies.
DISCLOSURE
No potential conflict of interest relevant to this article was reported.
KEY POINTS
QUESTION: What is the prevalence of PET/CT findings after COVID-19 mRNA vaccination, and are they associated with the patient’s immune status?
PERTINENT FINDINGS: In this cross-sectional study of 426 patients after COVID-19 mRNA vaccination, 45% of the 377 who underwent 18F-FDG PET/CT showed increased axillary lymph node uptake, which was significantly inversely associated with age and immunosuppressive status.
IMPLICATIONS FOR PATIENT CARE: Axillary lymph node 18F-FDG uptake ipsilateral to the mRNA COVID 19 injection site may hint about the patient’s immune response to the vaccine.
Footnotes
Published online April 23, 2021.
- © 2022 by the Society of Nuclear Medicine and Molecular Imaging.
Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.
REFERENCES
- Received for publication February 25, 2021.
- Revision received April 21, 2021.