Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Denoising Low-count PET images Using a Dilated Convolutional Neural Network for Kinetic Modeling

Mario Serrano-Sosa, Karl Spuhler, Christine DeLorenzo and Chuan Huang
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 437;
Mario Serrano-Sosa
1Stony Brook University Glen Cove NY United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Karl Spuhler
2NYU Langone New York NY United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christine DeLorenzo
3Stony Brook Medicine Stony Brook NY United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chuan Huang
3Stony Brook Medicine Stony Brook NY United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

437

Objectives: Quantitatively accurate PET images are essential in psychiatric studies to assess subtle differences between diseases. Recently, development of denoising techniques using convolutional neural networks (CNN) for quantitatively accurate low-count PET reconstruction has attracted substantial interest. In this work, we use kinetic modeling to evaluate the performance of our novel multiscale dilated CNN (dNet) and compare it to the well adopted uNet architecture, and, more importantly, full-count data. With dilated kernels, our dNet avoids down-sampling and up-sampling feature maps, a technique used in uNet which typically degrades resolution and fine details. Methods: All models had five channels and were trained using a 2.5D scheme (slabs) to afford the network a degree of 3D information. These slabs contained the slice of interest (middle slice) with two superior and two inferior slices to form a 3D slab. A total of 35 subjects were acquired and split into training (n=30, ~3000 slabs) and testing (n=5). Each subject was administered between 148-185 MBq (4-5mCi) of 18F-FDG and asked to void their bladder immediately after injection. This study acquired listmode data using a dedicated MRI head coil for 60 minutes immediately after the injection of 18F-FDG using a Siemens Biograph mMR PET/MRI scanner. Attenuation maps were generated using an established MRI-based algorithm1,2. Scanner attenuation maps were also extracted for reconstruction. We developed two deep learning models for comparison of PET image denoising: a conventional uNet and our proposed dNet (Figure 1). Kinetic modeling was used to analyze both CNN models. Metabolic rate of glucose (MRglu) was calculated at the voxel-level using the Patlak algorithm3. We used seven frames starting at 10 minutes after injection with temporal frame lengths of 4x5min and 3x10min4. Each frame was reconstructed using OSEM (6 iterations, 21 subsets), interframe motion was corrected and images were then registered to the subject’s T1w MRI. The CNN networks were retrained for each temporal frame using the training sets and methods as listed above. Denoising was performed using the corresponding network for images of a given frame. In the voxel-level analysis, mean absolute percent error (MAPE) of the CNN-denoised data relative to the full-count dataset was the figure of merit. Residual learning was included into both networks.

Results: Quantitative analysis showed both CNNs demonstrate good performance in voxel-level Patlak modeling compared to low-count data. Figure 2 shows a histogram of absolute percent error gathered across all testing set subjects. Both dNet (mean = 8.48%) and uNet (mean=9.61%) significantly outperformed the low-count PET data (mean=12.72%). Representative sagittal and coronal slices of voxel-level MRglu images are shown in Figure 3. Conclusion: Our novel approach of using a dilated convolutional neural network architecture for low-count PET denoising is a quantitatively accurate way to recover full-count PET images. Future denoising machine learning methods could utilize the spatially conserving aspect of dNet to improve their results.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Denoising Low-count PET images Using a Dilated Convolutional Neural Network for Kinetic Modeling
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Denoising Low-count PET images Using a Dilated Convolutional Neural Network for Kinetic Modeling
Mario Serrano-Sosa, Karl Spuhler, Christine DeLorenzo, Chuan Huang
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 437;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Denoising Low-count PET images Using a Dilated Convolutional Neural Network for Kinetic Modeling
Mario Serrano-Sosa, Karl Spuhler, Christine DeLorenzo, Chuan Huang
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 437;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
  • Keel-Edge Height Selection for Improved Multi-Pinhole 123I Brain SPECT Imaging
  • Ultra-Fast Reconstruction of Short List-Mode PET Data Frames for Real-Time Visualization and Processing
Show more Physics, Instrumentation & Data Sciences

Image Denoising PET

  • Investigation of lesion detectability using deep learning based denoising methods in oncology PET: a cross-center phantom study
  • Deep Denoising of O-15 Water Dynamic PET Images without Training Data
  • [68Ga]-DOTATATE PET Image Denoising using Unsupervised Deep Learning can Improve CNR in A Wide Range
Show more Image Denoising PET

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire