Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Design of a dual-head multi-pinhole collimator for brain SPECT with improved axial sampling

Arda Konik, Kesava Kalluri, Ling Chen, Greta Mok, Timothy Fromme, George Zubal, Lars Furenlid and Michael King
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 359;
Arda Konik
4University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kesava Kalluri
4University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ling Chen
3Department of Electrical and Computer Engineering University of Macau Macau China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Greta Mok
2University of Macau Taipa Macao
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timothy Fromme
5Robotics Engineering and Computer Science Worcester Polytechnic Institute Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
George Zubal
6Z-Concepts LLC East Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lars Furenlid
1University of Arizona Tucson AZ United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael King
4University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

359

Objectives: We designed a multi-pinhole (MPH) collimator for clinical brain SPECT imaging, which could potentially be used with the recently reported Tau-SPECT tracers (H. Watanabe et al, 2016). In this design two identical MPH collimators replace the existing collimators on a general-purpose-dual-head SPECT system. The pinholes are arranged at different axial positions to improve sampling. In addition, the collimator on one head is rotated 180 degree (about the axis normal to the collimator plane) with respect to the other one to further increase the axial sampling. Method: We determined the geometry of the system (e.g., number of pinholes, aperture size, aperture positions, aperture-center-of-field-of view distance, and aperture-detector distance) by maximizing system sensitivity for a target ellipsoidal (principal semi-axes, a:10.5, b:10.5, c:9 cm) volume-of-interest (VOI) covering 99-percentile head size and a target system resolution of 7 mm at the focal point on the axis-of-rotation. Constraints in optimization were fitting around the 99-percentile shoulder width of patients during rotation, minimum radius of rotation for brain, and <30% of multiplexing. We performed analytic and GATE Monte Carlo simulations of this system for uniform activity within the VOI, and clinical distributions within the XCAT brain phantom.

Results: Our preliminary results showed that 6-pinhole version offers the highest sensitivity. However, better axial sampling is obtained with the 7-pinhole version, which offers the second highest sensitivity (0.008%) and slightly lower multiplexing (24%). We altered the pinhole positions on the 7-pinhole version to further improve the axial sampling, which also resulted in further reduction in multiplexing (18%). We will present the results for the optimization algorithm over a range of numbers of pinholes and simulation results obtained from selected collimator designs. Conclusions: We designed and simulated an MPH system for general brain SPECT imaging. In future work we will assess through simulations the performance of the selected designs for quantitative measures such as striatal binding ratio (SBR) for Parkinson’s Disease imaging and cortical to cerebellum ratio (CCR) in Tau imaging for Alzheimer’s Disease. Acknowledgment This work was supported by the National Institute of Biomedical Imaging and Bioengineering (NIBIB) grant R01-EB022092. The contents are solely the responsibility of the authors and do not represent the official views of the NIBIB.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Design of a dual-head multi-pinhole collimator for brain SPECT with improved axial sampling
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Design of a dual-head multi-pinhole collimator for brain SPECT with improved axial sampling
Arda Konik, Kesava Kalluri, Ling Chen, Greta Mok, Timothy Fromme, George Zubal, Lars Furenlid, Michael King
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 359;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Design of a dual-head multi-pinhole collimator for brain SPECT with improved axial sampling
Arda Konik, Kesava Kalluri, Ling Chen, Greta Mok, Timothy Fromme, George Zubal, Lars Furenlid, Michael King
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 359;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

New System Designs and Emerging Technologies

  • Development of a simultaneous PET/Ultrasound imaging system with near real-time reconstruction capability for point-of-care applications
  • Point spread function modeling for pinhole SPECT imaging which accounts for aperture size and orientation.
Show more New System Designs and Emerging Technologies

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire