Abstract
Precise regional quantitative assessment of renal function is limited with conventional 99mTc-labeled renal radiotracers. A recent study reported that the PET radiotracer 2-deoxy-2-18F-fluorosorbitol (18F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, 18F-FDS is available via simple reduction from routinely used 18F-FDG. We aimed to further investigate the potential of 18F-FDS PET as a functional renal imaging agent using rat models of kidney disease. Methods: Two different rat models of renal impairment were investigated: induction of acute renal failure by intramuscular administration of glycerol in the hind legs, and induction of unilateral ureteral obstruction by ligation of the left ureter. At 24 h after these procedures, dynamic 30-min 18F-FDS PET data were acquired using a dedicated small-animal PET system. Urine 18F-FDS radioactivity 30 min after radiotracer injection was measured together with coinjected 99mTc-diethylenetriaminepentaacetic acid urine activity. Results: Dynamic PET imaging demonstrated rapid 18F-FDS accumulation in the renal cortex and rapid radiotracer excretion via the kidneys in healthy control rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in acute renal failure rats and unilateral ureteral obstruction kidneys. Measured urine radiotracer concentrations of 18F-FDS and 99mTc-diethylenetriaminepentaacetic acid correlated well with each other (R = 0.84, P < 0.05). Conclusion: 18F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. 18F-FDS PET imaging, with its advantages of high spatiotemporal resolution and simple tracer production, could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging.
The best indicator of kidney function is considered to be the glomerular filtration rate (GFR). However, because the filtration process occurs simultaneously in millions of glomeruli, a direct measurement of GFR is not feasible (1). The filtered agent 99mTc-diethylenetriaminepentaacetic acid (99mTc-DTPA) is widely available as a means to determine split GFR estimation by plotting dynamic renogram time–activity curves from planar images. However, precise regional assessment of renal function is limited by this 2-dimensional approach. Furthermore, Compton scatter and soft-tissue attenuation are major obstacles for reliable quantification. The use of hybrid imaging devices such as SPECT/CT enables 3-dimensional anatomic coregistration; however, the prolonged SPECT acquisition time and the limited temporal resolution reduce the potential of dynamic imaging (2).
Dynamic tomographic imaging with PET has the intrinsic advantage of high temporal and spatial resolution when compared with the 2-dimensional planar approach used with single-photon imaging agents. Furthermore, as previously confirmed in an experimental study on healthy rats, the PET radiotracer 2-deoxy-2-18F-fluorosorbitol (18F-FDS) has emerged as a promising candidate for measuring renal function with high kidney extraction and excretion, low plasma protein binding, and high metabolic stability (3). Given the simple 1-step reduction of the most frequent PET radiotracer, 18F-FDG, the use of 18F-FDS might open the window to the clinical availability of renal PET imaging.
The purpose of the present study was to elucidate the imaging and kinetic characteristics of 18F-FDS for the assessment of renal function in renally impaired rats using models of acute renal failure (ARF) and unilateral ureteral obstruction (UUO).
MATERIALS AND METHODS
Radiotracer Production
18F-FDS was synthesized by following a previously described procedure (4). In short, NaBH4 (2 mg, 0.053 mmol) was added to a solution of 18F-FDG in saline, and the resulting mixture was stirred at 35°C for 15 min. After quenching of the reaction, the mixture was adjusted to a pH of 7.4 and filtered through an Alumina-N Sep-Pak cartridge (Waters). The filtrate was then reconstituted in saline and passed through a 0.22-μm Millipore filter into a sterile multidose vial. A radiochemical purity of more than 95% was confirmed for 18F-FDS by radio–thin-layer chromatography (CR 35 Bio; Raytest) (80% acetonitrile with 20% water as eluent) (3).
DTPA kits (Fujifilm RI Pharma) were labeled using generator-produced 99mTc-pertechnetate according to the manufacturer’s instructions.
Animal Preparation
Male Wistar rats weighing 200–250 g (n = 18) were used. Experimental protocols were approved by the regional governmental commission of animal protection and conducted in strict accordance with the Guide for the Care and Use of Laboratory Animals published by the U.S. National Institutes of Health (5). ARF was induced by intramuscular injection of 50% glycerol (10 mL/kg) in each hind leg after a 24-h water deprivation period (n = 5) (6,7). At 24 h after glycerol injection, experimental tracer studies were conducted. UUO was induced by complete ligation of the left ureter near the renal pelvis (n = 9) (8). At 24 h after the ligation procedure, experimental studies were performed. As controls, experimental studies were also performed on 4 healthy rats.
Small-Animal PET Imaging
The rats were studied with a high-resolution dedicated small-animal PET system (Inveon microPET; Siemens Healthcare) (9). They were maintained under anesthesia by 2% isoflurane during the entirety of the experiments. 18F-FDS (30 MBq) was administered via the tail vein for PET imaging, and 99mTc-DTPA (2 MBq) was coinjected for reference for urine γ-counting and autoradiography. The 30-min list-mode scan was started just before radiotracer injection. The list-mode data were sorted into 3-dimensional sinograms, which were then rebinned with fully 3-dimensional binning to reconstruct dynamic images using 3-dimensional ordered-subset expectation maximization. The reconstructed dynamic images consisted of 56 acquired frames (15 frames × 8 s, 26 frames × 30 s, and 15 frames × 60 s).
The obtained PET images were analyzed using an image-processing application (AMIDE imaging software, version 1.0.1) (10). Three-dimensional regions of interests were manually drawn over the entire kidney, including the medulla. The mean concentration of radioactivity within the regions of interests was expressed as the percentage injected dose per cubic centimeter of tissue. Time–activity curves (renography) were generated, and the time points of maximal (Tmax) and half-maximal (T½max) concentration were computed.
Postmortem Analysis
For γ-counting, plasma was collected via the tail artery during the PET acquisition (10 min after tracer delivery). After the PET acquisition (35 min after tracer injection), the rats were euthanized, urine was collected by opening the abdominal cavity, and autoradiography studies were conducted. Plasma (4 ARF rats, 4 controls) and urine (3 ARF rats, 3 controls) were counted for radioactivity in an automated γ-counter (Wizard; PerkinElmer). The radioactivity concentrations, expressed as percentage injected dose per gram, were calculated (3). The kidneys were frozen and cut into 20-μm short-axis slices using a cryostat (Leica). Dual-radiotracer autoradiography was performed to assess both 18F-FDS and 99mTc-DTPA uptake. First, the imaging plate (MultiSensitive Phosphor Screens; PerkinElmer) was exposed for 3 h to visualize the distribution of 18F-FDS with a digital autoradiography system (CR 35 Bio; Raytest). After 18 h to allow for the decay of 18F, a second exposure for 12 h was started to evaluate 99mTc-DTPA uptake. After autoradiography, tissue slices were stained with hematoxylin and eosin.
Statistics
All results are displayed as mean ± SD. The 2-tailed paired Student t test was used to compare differences between 2 dependent groups, and the 2-tailed independent Student t test was used to compare differences between independent groups. For correlative analyses, Pearson coefficients of correlation were calculated. A P value of less than 0.05 was considered statistically significant. Statistical analysis was done with StatMate III (ATMS Co., Ltd.) and JMP (SAS Institute Inc.).
RESULTS
Small-Animal Imaging
Whole-body dynamic PET imaging demonstrated high radiotracer excretion via the kidneys, with a low hepatobiliary clearance in control animals (Figs. 1 and 2). Blood flow through the inferior vena cava and the arterial vasculature was visualized, followed by a gradual delineation of the renal cortex and transition of the activity into the collecting system and renal pelvis (Fig. 1A). Visual analysis demonstrated that 18F-FDS was excreted solely through the urinary system and subsequently transited into the bladder. No obvious signals from other organs were detected (Fig. 1B). A normal renogram pattern consistent with blood-flow, parenchymal, and excretory phases, with a Tmax of 1.1 ± 0.6 min and a T½max of 12.2 ± 3.0 min, was derived in control rats (Fig. 1C, top). As expected, the bladder demonstrated a continuous radiotracer increase in control rats (Fig. 1C, bottom).
On PET images, uptake in the renal cortex was significantly less in ARF rats than in controls (Fig. 1A), and radiotracer excretion through the urinary system was lower. In particular, radiotracer transit to the bladder was delayed (Fig. 1B). These findings were further corroborated using averaged radiotracer time–activity curves. The derived renograms showed a nonfunctioning pattern, indicating that glomerular filtration was impaired after glycerol injection (Fig. 1C, top). Tmax was 0.5 ± 0.1 min in ARF rats (P < 0.05, vs. controls), whereas T½max was not reached during the 30-min scan. Additionally, bladder activity was reduced and delayed in the ARF model (Fig. 1C, bottom).
In UUO rats, enlarged PET images of the renal area displayed a weak to moderate radiotracer retention in the renal cortex over time (Fig. 2A). Lower and delayed uptake was observed on the obstructed side, with no transition into the collecting system and renal pelvis (Fig. 2B, left kidney), whereas the contralateral side (Fig. 2B, right kidney) showed results similar to those obtained in control rats. The derived renograms demonstrated a typical pattern for an obstructed kidney: on averaged time–activity curves, the increase in activity on the obstructed side was slow, with no further peak during the parenchymal phase and progressive parenchymal accumulation (Fig. 2C). For the UUO kidneys, Tmax was 22.7 ± 4.5 min (P < 0.0001 vs. controls), whereas T½max was not reached.
γ-Counting and Autoradiography Results
On γ-counting, the 18F-FDS concentrations in plasma (R = 0.77) and urine (R = 0.84) correlated well with the 99mTc-DTPA concentrations (P < 0.05, Table 1). Autoradiography confirmed a similar renal distribution for both radiotracers in control and ARF rats (Fig. 3). With regard to the hematoxylin and eosin staining, retained radioactivity was observed in the inner medullary collecting ducts.
In Vivo Stability and Plasma Protein Binding
Radio–thin-layer chromatography analysis of rat plasma samples and 18F-FDS solution revealed completely matched single spots in all samples from each group (n = 2), indicating the nonexistence of radiolabeled metabolites in blood 30 min after radiotracer administration. In vivo serum protein binding of 18F-FDS at 30 min after radiotracer administration was quantified as minimal (<0.1%) by separation of free 18F-FDS using ultrafiltration.
DISCUSSION
As the standard of renal function measurement, GFR assessment requires an exogenous marker that behaves similarly to inulin, that is, free filtration without any tubular secretion or absorption (11). Suitable exogenous markers for measuring renal function, such as 51Cr-EDTA, are widely used in clinical practice, and plasma clearance estimated by multiple blood samples increases its diagnostic accuracy, although repeated sampling makes it inconvenient (11). GFR estimation using 99mTc-DTPA planar imaging is biased by the applied method of scintigraphic GFR determination (12), and camera-based techniques depend on the precise assessment of renal depth for soft-tissue attenuation corrections (13). On the other hand, recent efforts have been made to develop novel renal imaging agents focusing on tubular function and renal plasma flow instead of measuring GFR (14,15). With kinetics identical to the gold standard 131I-orthoiodohippurate for measurement of effective renal plasma flow, 99mTc-(CO)3(fluoroethyl)iminodiacetic acid inherits the advantage of improved background activity correction; however, none of the methodology currently in place is able to solve this issue successfully (16,17). In contradistinction, as previously demonstrated in healthy rats and confirmed in the present study, 18F-FDS allows for almost complete elimination of background activity from surrounding organs (3). We observed rapid excretion via the urinary system (without visualized hepatobiliary clearance), high in vivo stability, and low serum protein binding. Furthermore, in 2 different rat models of kidney disease, functional impairment of the injured kidneys was successfully identified: in ARF rats, radiotracer extraction by and excretion through both kidneys was low, and radiotracer accumulation in the bladder was minimal. Imaging-derived renograms showed a bilateral nonfunctioning pattern. In the UUO rat model, radiotracer extraction from the blood pool was reduced, and transit from the cortex to the collecting system in the obstructed kidney was significantly impaired. Renograms demonstrated a typical obstructed pattern on the affected side.
In the present dual-tracer autoradiography study using the γ-camera imaging agent 99mTc-DTPA and the PET tracer 18F-FDS, biodistribution for the two radiotracers was comparable. However, renal PET imaging offers numerous advantages, such as increased spatiotemporal resolution and accurate tomographic 3-dimensional quantitative capability (17). As a competitor for PET renal imaging, 68Ga-EDTA was recently introduced as a substitute for 99mTc-DTPA (18). Compared with its 68Ga-labeled counterpart, 18F-FDS provides a cost-effective approach toward radiotracer production by a simple 1-step reduction of 18F-FDG, and its longer half-life allows for flexibility in study design. Further, it possesses the inherent advantages of lower positron energy along with higher positron yield. Strikingly, as an analog of sorbitol, 18F-FDS has kinetic properties that are theoretically identical to the gold standard inulin (sorbitol–to–inulin clearance ratio, 1.01) (19). However, regardless of which radiotracer is used, the major obstacle of renal PET imaging in a human setting has to been addressed—that is, current PET cameras do not allow imaging of the entire urinary system in a single field of view (18). Hence, it might be necessary to use costly large-field whole-body PET devices or to obtain multiple PET and CT acquisitions, which might hamper diagnostic accuracy.
In light of radiation exposure and higher costs, the clinical situation in which its use in renal radionuclide imaging would be most justified remains a matter of debate. A decade ago, renovascular hypertension and kidney transplant rejection were seen as major clinical indications for renal PET; however, improvements in drug development and the widespread availability of nonradiation methods such as ultrasound have led to a massive decline in such study requests in recent years (20–23). Currently, common clinical indications include monitoring during chemotherapy or assessment of split renal function for various clinical indications, such as before radiotherapy or before live kidney donation (24–26). Because of the superior spatial and temporal resolutions of PET, 18F-FDS could potentially be applied in those clinical situations, especially for determining differential glomerular filtration.
In view of the promising results of recently published randomized clinical trials, treatment of inoperable, metastasized neuroendocrine tumors with radiolabeled somatostatin analogs is currently gaining ground (27). However, renal irradiation from peptide receptor radionuclide therapy is most likely to be caused by cross fire of radiolabeled somatostatin analogs from adjacent tubules, and it was hypothesized that serial 99mTc-mercaptoacetyltriglycine studies might be a superior indicator for early stages of kidney dysfunction caused by endoradiotherapy (28). However, measurement of tubular extraction rate was unsuitable as an early way to identify an increased probability of later renal failure (29). Hence, a dual-radiotracer approach using somatostatin receptor PET together with 18F-FDS PET could potentially be applied to patients scheduled for peptide receptor radionuclide therapy and replace common renography studies in the long term.
Most importantly, creatinine clearance–based estimates of GFR are often used in pediatrics. However, changes in body mass limit the reliability of this method, and accuracy is hampered in children with renal and urologic disorders (17). Moreover, children can also have anatomic abnormalities of the kidney, such as ureteropelvic junction obstruction (30). Ideally, in these difficult clinical situations, 18F-FDS renal PET might set the scene for effective decision making, as it provides simultaneous information about anatomic conditions and about the functional significance of an obstruction (17). Given the increased count rates obtained with 18F-FDS, as compared with conventional imaging agents such as 99mTc-DTPA, a much lower activity of 18F can be administered. Hence, mainly because of the advantages of PET over SPECT, 18F-FDS could potentially minimize radiation exposure in children without sacrificing image quality. Moreover, when a PET/CT study is performed, the additional radiation exposure from the CT component should also be considered. However, use of a low-dose or ultra–low-dose CT scan along with the narrow field of view necessary for renal imaging could further lower radiation exposure to less than 0.25 mSv (2).
CONCLUSION
In 2 rat models of kidney disease, 18F-FDS PET demonstrated favorable kinetics for functional renal imaging. Renal PET/CT has the potential to provide improved spatial and temporal functional data when the clinical situation does not allow relevant information to be easily obtained by other common noninvasive techniques. Because of its superior diagnostic performance and simple production via reduction of 18F-FDG, 18F-FDS might meet this urgent need in renal radionuclide imaging. Strikingly, 18F-FDS could potentially minimize radiation exposure in children without sacrificing image quality. Further confirmatory studies in humans are warranted.
DISCLOSURE
This work was supported by the Competence Network of Heart Failure funded by the Integrated Research and Treatment Center (IFB) of the Federal Ministry of Education and Research (BMBF) and the German Research Council (DFG grant HI 1789/3-3). This project received funding from the European Union’s Horizon 2020 research and innovation program under Marie Sklodowska-Curie grant agreement 701983. Hiroshi Wakabayashi received a JSPS Grant-in-Aid for Research (17K10353). No other potential conflict of interest relevant to this article was reported.