Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Respiratory Phase Matching in PET/CT Using Fast Spiral CT

James Hamill, Osama Mawlawi and Joseph Meier
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 577;
James Hamill
2Siemens Healthcare Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Osama Mawlawi
1MD Anderson Cancer Center Houston TX United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joseph Meier
3UT MD Anderson Cancer Center Houston TX United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

577

Objectives: In a whole-body PET/CT study, patient motion during the CT and PET scans affects the spatial alignment of CT and PET images, sometimes leading to errors in image interpretation and PET attenuation correction. To address this problem, we have developed a method for automatically aligning PET and CT images in normal PET/CT protocols. The method uses a respiration-correlated waveform and has the same CT radiation exposure as in standard PET/CT. We demonstrate the improved alignment and the relationship between noise and distortion for different approaches to PET image reconstruction.

Methods: Our novel approach is called matched PET/CT and is to be compared with conventional static PET, amplitude-based gating into a single gate with retention of 35% of acquired data (HD Chest ), and phase-based gated PET. 25 oncology patients with known thoracic or liver lesions, 30 mm or less in size, were injected with 18F-FDG and scanned, 60 minutes later, in continuous bed motion mode on a Siemens mCT Flow PET/CT system. The protocol used a non-gated low-dose spiral CT scan during free breathing, followed by list-mode PET, also in free breathing. A respiration monitoring device collected waveform data during CT and PET, allowing measurement of respiratory phase and respiratory amplitude. Automated analysis of the waveform assigned a phase or amplitude to each CT slice. Matching images from the two modalities was based on determining, slice by slice, the PET phase or amplitude that most closely corresponded to CT. In the phase-based case, we used 8 or 16 PET gates. The latter resulted in less intra-frame blurring but more image noise. To measure the displacement between CT and PET in each case, we calculated the distance between the centers of gravity of 3D contours drawn on lesions on the respective PET and CT images. In the case of gated PET, we determined which gate corresponded to the smallest displacement value, a non-automated method that defined the so-called best gate for that lesion. Additionally, for each case, we evaluated the lesions’ maximum standardized uptake values (SUVmax) and characterized the image noise.

Results: In a preliminary analysis of 12 lesions with the phase-based method and 8 gates, average PET-CT displacements (and standard deviations) for matched, static, HD Chest, and the best gate were 4.2 ± 4.6, 4.9 ± 4.8, 6.4 ± 4.1 and 2.5 ± 3.5 mm . Lesion SUVmax were highest in HD Chest and gated images. When we compared images according to image noise, they ranked as follows from least to most noisy: static, HD Chest, matched based on 8 gates, 8 gates, matched based on 16 gates, and 16 gates. We evaluated three methods of interpolating between gates. Nearest neighbor interpolation resulted in distorted, noisy images. Bilinear interpolation reduced distortions but introduced a noise pattern that varied between slices. Convolution with a 1-2-1 kernel resulted in a comparatively low noise and a reduced level of image distortions.

Conclusion: The alignment of PET and CT can be improved with an automated method based on measuring respiratory waveforms during CT and PET. The CT dose was unchanged from conventional PET/CT. Research Support:

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 58, Issue supplement 1
May 1, 2017
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Respiratory Phase Matching in PET/CT Using Fast Spiral CT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Respiratory Phase Matching in PET/CT Using Fast Spiral CT
James Hamill, Osama Mawlawi, Joseph Meier
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 577;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Respiratory Phase Matching in PET/CT Using Fast Spiral CT
James Hamill, Osama Mawlawi, Joseph Meier
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 577;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

PET Quantitation & Reconstruction

  • Evolution-scaled quadratic prior for penalized iterative reconstruction in PET
  • Using high-resolution time-of-flight for automatic PET/CT misalignment detection and correction
  • Investigation of TOF benefits on the Celesteion PET/CT scanner
Show more PET Quantitation & Reconstruction

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire