Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Preliminary Results of a Depth-of-Interaction based PET System with Dual Ended Readout for Combined Breast PET/CT Imaging

Martin Judenhofer, M.G. Buddika Sumanasena, Kuang Gong, Qiyu Peng, George Burkett, Benjamin Spencer, Jinyi Qi and Ramsey Badawi
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 223;
Martin Judenhofer
3Biomedical Engineering UC Davis Davis CA United States
4Dept. Radiology UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M.G. Buddika Sumanasena
1Silver Spring MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kuang Gong
3Biomedical Engineering UC Davis Davis CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Qiyu Peng
2Lawrence Berkley National Laboratory Berkely CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
George Burkett
4Dept. Radiology UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Benjamin Spencer
4Dept. Radiology UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jinyi Qi
3Biomedical Engineering UC Davis Davis CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ramsey Badawi
4Dept. Radiology UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

223

Objectives: Dedicated PET and CT imaging of the breast in cancer patients can have an advantage due to better spatial resolution obtained in both modalities. We propose the development of a dedicated breast PET imager that utilizes PET detectors which provide depth-of-interaction (DOI) information to reduce the spatial resolution degradation at off-center locations in the trans-axial field of view (FOV). This PET system will finally be combined with a CT to provide sequential acquisition of PET and CT data of the pendent breast. We report on the preliminary imaging results of an initial single-ring prototype built using DOI PET detectors.

Methods: We have developed a modular PET detector based on 14x14 arrays of 1.5x1.5x20 mm3 Lutetium Yttrium Orthosilicate (LYSO) crystals, unpolished and separated by a diffuse reflector film. The module employs a dual ended readout using a Position Sensitive Photo-Multiplier-Tube (PSPMT, R8900, Hamamatsu) for crystal encoding and energy detection on the backside (away from the center) and a compact Avalanche Photo Diode (APD, 21x21 mm2, Radiation Monitoring Devices) detector (2 mm thick) on the front side (close to the center) to obtain energy information. The DOI information is calculated as the ratio of the total energy detected by either photo-detector. In previous characterization experiments of this module achieved a DOI resolution of 1.8 mm and energy resolution of 18% in a bench-top setup. To readout all detectors of a complete PET ring we utilize a commercial PET electronics suite (Siemens Molecular Imaging) developed for PMT-based block detectors (4 channels per detector). We have modified the firmware of the PET electronics suite to use the analog inputs of two blocks detectors (4 + 4 channels) to decode both position and DOI information as required for our PET detector. Our prototype system consists of 24 block detectors arranged in a single ring of 200 mm inner diameter covering a transaxial FOV of 150 mm and an axial FOV of 22 mm. APDs were cooled below room temperature for low noise operation. We have measured the DOI resolution performance using the implemented firmware processing and have assessed the system’s point spread function as full width at half maximum (FWHM) of a reconstructed Na22 point source (20 µCi, with artificial background during reconstruction) at the radial center and at 2.5 and 5 cm off-center. Images were reconstructed using a listmode based maximum likelihood expectation maximization algorithm.

Results: We have successfully modified the PET electronics to readout the DOI PET block detectors. Using the modified firmware we obtained a DOI resolution of 3.1 mm and energy resolution of 24%. Acquired PET images of the point source at the center position revealed a FWHM of the measured point spread function of 1.4 mm without using DOI and 1.3 mm with DOI information. At off center positions of 2.5 cm and 5.0 cm the FWHM dropped to 2.1 and 2.8 mm without DOI but remained at 1.6 mm and 1.9 mm when using the DOI information.

Conclusion: Our results show the use of a DOI-capable detector can significantly reduce the effect of image blur for radially off-center objects. Using a commercial PET electronics is possible but resulted in some loss of performance due to the limited accuracy of the FPGA implementation. Research Support: This work was supported by grant NCI R01 CA129561, by the Rusch Fund for Nuclear Medicine and by the UC Davis Department of Radiology. $$graphic_76E1D3F7-7AE2-4A8C-B4A2-A58DC8A8DCE8$$

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 58, Issue supplement 1
May 1, 2017
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Preliminary Results of a Depth-of-Interaction based PET System with Dual Ended Readout for Combined Breast PET/CT Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Preliminary Results of a Depth-of-Interaction based PET System with Dual Ended Readout for Combined Breast PET/CT Imaging
Martin Judenhofer, M.G. Buddika Sumanasena, Kuang Gong, Qiyu Peng, George Burkett, Benjamin Spencer, Jinyi Qi, Ramsey Badawi
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 223;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Preliminary Results of a Depth-of-Interaction based PET System with Dual Ended Readout for Combined Breast PET/CT Imaging
Martin Judenhofer, M.G. Buddika Sumanasena, Kuang Gong, Qiyu Peng, George Burkett, Benjamin Spencer, Jinyi Qi, Ramsey Badawi
Journal of Nuclear Medicine May 2017, 58 (supplement 1) 223;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

New Systems

  • Development of the MRC-SPECT-II System:Experimental Evaluation and Modeling of a Prototype Inverted-Compound-Eye Gamma Camera
  • A hand-held hybrid gamma-near-infrared fluorescence imaging camera
  • A mobile SPECT system using variable angle, slant hole collimation
Show more New Systems

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire