Abstract
Tumor endothelial marker 1 (TEM1/endosialin) is a tumor vascular marker highly overexpressed in multiple human cancers with minimal expression in normal adult tissue. In this study, we report the preparation and evaluation of 124I-MORAb-004, a humanized monoclonal antibody targeting an extracellular epitope of human TEM1 (hTEM1), for its ability to specifically and sensitively detect vascular cells expressing hTEM1 in vivo. Methods: MORAb-004 was directly iodinated with 125I and 124I, and in vitro binding and internalization parameters were characterized. The in vivo behavior of radioiodinated MORAb-004 was characterized in mice bearing subcutaneous ID8 tumors enriched with mouse endothelial cells expressing hTEM1 and by biodistribution and small-animal immuno-PET studies. Results: MORAb-004 was radiolabeled with high efficiency and isolated in high purity. In vitro studies demonstrated specific and sensitive binding of MORAb-004 to MS1 mouse endothelial cells expressing hTEM1, with no binding to control MS1 cells. 125I-MORAb-004 and 124I-MORAb-004 both had an immunoreactivity of approximately 90%. In vivo biodistribution experiments revealed rapid, highly specific and sensitive uptake of MORAb-004 in MS1-TEM1 tumors at 4 h (153.2 ± 22.2 percentage injected dose per gram [%ID/g]), 24 h (127.1 ± 42.9 %ID/g), 48 h (130.3 ± 32.4 %ID/g), 72 h (160.9 ± 32.1 %ID/g), and 6 d (10.7 ± 1.8 %ID/g). Excellent image contrast was observed with 124I-immuno-PET. MORAb-004 uptake was statistically higher in TEM1-positive tumors than in control tumors. Binding specificity was confirmed by blocking studies using excess nonlabeled MORAb-004. Conclusion: In our preclinical model, with hTEM1 exclusively expressed on engineered murine endothelial cells that integrate into the tumor vasculature, 124I-MORAb-004 displays high tumor–to–background tissue contrast for detection of hTEM1 in easily accessible tumor vascular compartments. These studies strongly suggest the clinical utility of 124I-MORAb-004 immuno-PET in assessing TEM1 tumor-status.
Tumor vascular markers (TVMs) are attractive targets for antibody-based diagnostics and therapeutics. Targeting tumor vasculature rather than tumor cells themselves has several advantages. Among these, tumor vasculature expresses unique molecular targets that are absent in normal vasculature, vascular targets are less likely to be lost due to adaptation or mutations, and TVMs are readily accessible to blood circulation. Consequently, TVMs are attractive targets for antibody-based cancer diagnosis of molecular phenotype and personalized therapy (1–3).
Tumor endothelial marker 1 (TEM1)/endosialin/CD248 is emerging as a robust TVM in multiple human cancers (4,5). These early studies concluded that TEM1-positive cells are tumor endothelial cells. However, nearly all carcinomas, including ovarian, lung, and breast cancer, have TEM1 expression that is restricted to tumor-associated perivascular cells (pericytes) and stromal cells (6–12). In sarcomas, ranging from neuroblastoma to colorectal cancers to highly invasive glioblastomas, TEM1 is also expressed in malignant cancer cells (6,13–15). TEM1 is a heavily O-glycosylated 175-kDa type I transmembrane protein of the C-type lectin-like receptor family, which shares overall architecture with thrombomodulin (11). The extracellular domain contains a C-type lectin-like domain, 3 epidermal growth factor–like repeats, and a proline-rich mucin domain, whereas the intracellular domain is fairly short (51 amino acids), with 3 potential phosphorylation sites and a C-terminal PDZ-binding motif (16). This surface protein is not shed, but little is known on its modulation or internalization in response to epitope engagement by antibodies and other TEM1-targeted therapies. Its high expression on the tumor vasculature across a wide variety of solid human cancers, with limited expression in normal adult tissue, makes human TEM1 (hTEM1) an ideal target for exogenous antibody therapies and diagnostics (17–19).
A humanized IgG monoclonal antibody (mAb) directed to human endosialin/TEM1 (MORAb-004; Morphotek, Inc.) (20) is currently being explored in phase I/II clinical trials for its potential antiangiogenic and antineoplastic activity in solid and soft-tissue tumors. The efficacy of this anti-TEM1 mAb against solid tumors is also being investigated in combination with chemotherapy (21). The mechanism of action of MORAb-004 in vivo appears to be mediated by inhibiting the cell surface association of TEM1 with extracellular matrix proteins including fibronectin, collagen I/IV (20), and the Mac-2 BP/90K protein (22).
A critical factor in targeted therapy is evaluating the presence and amount of the specific target in the tumor and its relevance to the disease state. The overexpression of TEM1 on tumor vasculature provides a potential target for the specific diagnosis and therapy of TEM1-positive (TEM1+) tumors. Initial clinical experience by immunohistochemistry analysis reveals that high TEM1 levels correlate with high tumor grade and aggressive tumor behavior (7,23). Along with other pathologic procedures and tests, noninvasive nuclear imaging is often used to assess the status of the specific target. Multiple antibodies against TEM1 have been reported (17,24), however, there is limited demonstration of whether this TVM can function as a target for tumor detection in diagnostic nuclear medicine. Considering the superiority of PET over single-photon scintigraphy, the development of an hTEM1-specific PET radioimmunoconjugate is a worthwhile pursuit. Because of its high resolution, sensitivity, and unique ability to measure tissue concentrations of radioactivity in 3 dimensions, PET is the method of choice for in vivo imaging using therapeutic and diagnostic antibodies. 124I is a positron-emitting radioisotope that can be attached to antibodies generally without significant loss of immunobiologic characteristics; its 4.2-d half-life allows assessment of long-term pharmacokinetics of antibody forms (25–27). To the best of our knowledge, this report represents the first study of a positron-emitting form of a TEM1-directed antibody construct in a murine mouse model of hTEM1-expressing tumor vasculature.
MATERIALS AND METHODS
Antibodies and Cell Lines
Humanized anti-hTEM1 MORAb-004 mAb (IgG1, 160 kDa), which binds human but not murine TEM1, was produced by Morphotek, Inc. The MS1 mouse endothelial cell line, engineered to express DsRed and firefly luciferase fLuc (for ease, designated as MS1), was used for subsequent generation of the MS1-TEM1 cell line, expressing hTEM1, and EmGFP, in addition to DsRed and fLuc (18). MS1-TEM1 cells were sorted by flow-assisted flow cytometry sorting using a MoFlo cell sorter (Dako Cytomation), and the cell population with lower hTEM1 expression was expanded and used for subsequent studies. ID8 is a mouse ovarian surface epithelium cancer cell line, provided by Dr. Paul Terranova (University of Kansas Medical Center) (28). MS1 cell lines and the ID8 cell line were maintained in RPMI 1640 containing 10% fetal bovine serum and antibiotics. Full details of all methods and equipment used are presented in the supplemental materials (available at http://jnm.snmjournals.org).
Radiolabeling
Iodination of MORAb-004 mAb and control IgG1 was performed by the IODO-GEN method (Pierce) (29). Briefly, 125I-NaI (in 0.01N NaOH; Perkin Elmer) or 124I-NaI (in 0.02 M NaOH; IBA Molecular) was added to a precoated iodination tube (Thermo Scientific) containing antibody (15 μg, 1 mg/mL in phosphate-buffered saline) and incubated for 5 min. Radiolabeled antibody was purified using a 2-mL desalting column (Thermo Scientific). Trichloroacetic acid precipitation assay (30) and radio–thin-layer chromatography were used to determine radiolabeling efficiency and purity for labeled antibodies. Protein concentration was measured using Nanodrop 2000c (Thermo Scientific) to calculate specific activity (MBq/mg).
In Vitro Characterization
Radioimmunoassay
Assessment of specific binding of 125/124I-MORAb-004 was determined by radioimmunoassay using cells grown to confluence on 1% gelatin-coated 96-strip well microplates (Corning Life Sciences). For direct mAb binding assay, cells were incubated with increasing concentration of 125/124I-MORAb-004 in assay buffer (5% fetal bovine serum in RPMI 1040) in quadruplicate at 4°C for 4 h. Cells were washed 5 times with ice-cold wash buffer (3% bovine serum albumin/phosphate-buffered saline). Cell-associated radioactivity was measured by a γ counter (2470 Wizard2, Perkin Elmer) and normalized to the total number of cells, counted by hemocytometer. Nonspecific binding was determined using control MS1 cells or by performing the assay in 100-fold excess of unlabeled ligand. Radioimmunoassay analysis was performed as previously described (30). The details to determine the apparent binding affinity, Kd; the number of functional binding sites per cell, Bmax; and the binding inhibition constant, Ki, can be found in the supplemental materials. In competitive binding assays, cells were incubated with a fixed concentration of 125/124I-mAb for 4 h at 4°C, in the presence of unlabeled MORAb-004 (0–200 nM). Binding data were collected as above and the competitive binding data plotted as described in the supplemental materials.
Internalization Assay
For fluorescent ligand assay, cells were cultured on chamber slides (Nunc; Life Technologies) overnight at 37°C in culture medium. Cells were incubated with DyLight405-MORAb-004 immunoconjugate (1 mL, 1.5 mg/mL in medium) at 4°C and allowed to warm to 37°C for 1 h. After two 5-min washes with wash buffer (or additional glycine buffer wash [pH 2; 200 mM glycine; 150 mM NaCl]), cells were fixed with 2% paraformaldehyde. Images were taken with an inverted LSM510 confocal microscope (Carl Zeiss), using a 405-nm diode laser, 488-nm argon laser, and 561-nm diode laser for excitation of Dylight405, EmGFP, and DsRed, respectively.
For the radioligand assay, cells were grown to confluence on 1% gelatin-coated 96-strip well microplates and incubated with 125I-MORAb-004 at 37°C at selected time points up to 24 h. Cells were placed on ice and rinsed with wash buffer. Parallel plates were washed with glycine buffer (pH 2) twice for 5 min to remove surface-bound radioactivity. Wells were counted in a γ counter and normalized to total activity bound.
In Vivo Characterization
Chimeric hTEM1-Expressing Murine Vascular Graft Model
All animal experiments were conducted in compliance with the guidelines of the Institutional Animal Care and Use Committee. Chimeric tumors expressing hTEM1 in the vasculature were established by subcutaneous injection of 2 × 106 ID8 cancer cells comixed with MS1-TEM1 or MS1 endothelial cells (at a ratio of 1:5 ID8 to MS1) in each mouse flank of female athymic nu/nu mice (Crl:NU-Foxn1nu; weight, 18 g; age, 4–6 wk; Charles River Laboratories, Inc.). Mice were provided with food and water ad libitum. Mice with tumor grafts expressing fLuc reporter were anesthetized using 1%–2% isoflurane/O2 (VetEquip), and in vivo bioluminescence imaging was performed thrice weekly using the Xenogen IVIS Lumina II small-animal imaging system (Caliper Life Science). Briefly, d-Luciferin (phosphate-buffered saline stock [150 mg/mL]; 150 μL/15-g mouse) was injected intraperitoneally, and optical images were acquired at 10 min after injection. Pseudocolor images of emitted photon radiance (p/s/cm2/sr) were generated and quantified with Living Image Version 3.0 software (Caliper Life Science). Tumors were allowed to grow to a size of 5–10 mm in diameter (14–21 d), and then mice were used for subsequent studies.
Biodistribution and Autoradiography Studies
Naïve mice and mice bearing ID8 tumors comixed with MS1 or MS1-TEM1 endothelial cells were administered 125I-MORAb-004 (0.185 MBq [5 μCi], 2.5 μg mAb, in 150 μL of sterile 0.9% saline for injection) via the tail vein. Animals (n = 3–6, per group) were euthanized at 4, 24, 48, 72, and 144 h after injection, and organs and tumors were removed, weighed, and counted in a γ counter for accumulation of activity. In a separate cohort, tumors were harvested, embedded in Tissue-TEK OCT compound (Sakura, Finetek U.S.A Inc.), and frozen at −80°C. Serial 10-μm-thick sections were cut at −20°C in a cryostat (Leica CM1950). Sections were exposed to a phosphorimage plate (BAS; Fujifilm) for 48 h. Digital autoradiography images were read using a phosphor plate reader (Typhoon FLA-7000; GE Healthcare).
Immuno-PET Studies
PET experiments were conducted on a small-animal A-PET scanner (Mosaic; Philips) with an imaging field of view of 11.5 cm (31). Mice were administered 124I-MORAb-004 (5.2 MBq [∼140 μCi], 2.5 μg mAb, in 150 μL of sterile 0.9% saline for injection) via tail vein injection. For blocking studies, mice were coinjected with 25 μg of nonlabeled MORAb-004. Mice were anesthetized by inhalation of a 1%–2% isoflurane/O2 and placed on the scanner bed before the imaging study. PET data acquisition commenced at 4, 24, 48, and 72 h after injection of the radiotracer, and dynamic scans were obtained over a period of 1 h (5 min per frame; image voxel size, 0.5 mm3). Analysis on reconstructed images was performed using AMIDE (http://amide.source-forge.net). After termination of the final PET scan, mice were euthanized and tissue activity assessed.
Data Analysis and Statistics
All experiments were performed at least in triplicate, with a minimum of 3 independent experiments. Results are expressed as mean ± SD unless otherwise noted. Significant differences between means were determined using 1-way ANOVA followed by a post hoc Bonferroni multiple comparison test or unpaired Student t test, as appropriate. Differences at the 95% confidence level (P < 0.05) were considered statistically significant. All curve-fitting and statistical analyses were conducted using Prism 5.0 software (GraphPad).
RESULTS
Radioiodination
MORAb-004 was successfully radiolabeled with near-quantitative labeling efficiency. Radiochemical purity by radio–thin-layer chromatography and trichloroacetic acid precipitation assays showed that more than 98% of 125/124I was bound to protein after size-exclusion column purification (Supplemental Fig. 1). Specific activities for 125I-MORAb-004 ranged from 150 to 225 MBq/mg (4–6 mCi/mg; mean, 185 MBq/mg [5 mCi/mg]) and from 280 to 340 MBq/mg (7.6–9.2 mCi/mg) for IgG1 control (mean, 300 MBq/mg [8.1 mCi/mg]). For 124I-MORAb-004, specific activities were between 1,920 and 2,220 MBq/mg (52–60 mCi/mg; mean, 2,072 MBq/mg [56 mCi/mg]).
In Vitro Binding Properties of MORAb-004
The specificity of binding of 125I-MORAb-004 to hTEM1 was assessed with mouse endothelial MS1 cells engineered and subsequently sorted to express surface TEM1 as compared with control MS1 cells. The apparent dissociation constant (Kd) of 125I-MORAb-004 determined by live-cell radioimmunoassay was 3.41 ± 1.20 nM, and the number of MORAb-004 mAb bound per cell (Bmax) was 6.28 ± 2.14 × 105 (Fig. 1A). 125I-MORAb-004 did not bind to control MS1 cells, and binding on MS1-TEM1 cells could be blocked with excess unlabeled mAb, demonstrating specificity. Competitive binding assays demonstrated that 125I-MORAb-004 was displaced with increasing amounts of unlabeled MORAb-004, with the Ki of unlabeled MORAb-004 being 3.10 ± 1.24 nM (Fig. 1B). mAb immunoreactivity from radioimmunoassay was approximately 90% for both 125I-MORAb-004 and 124I-MORAb-004 after direct iodination at the noted specific activity (Table 1). 125I-MORAb-004 bound to endogenous hTEM1 with higher affinity (Kd ∼0.5 nM) when incubated with human neuroblastoma LA1-5s cells, as compared with recombinant hTEM1 expressed in the murine MS1-TEM1 cell line (Supplemental Fig. 2). The number of surface hTEM1 molecules is comparable between LA1-5s cells and MS1-TEM1 cells.
Internalization of MORAb-004
To qualitatively assess mAb internalization after binding to TEM1, we followed the location of fluorescent dye-labeled MORAb-004 (MORAb-004-Dy405) on MS1-TEM1 cells versus control MS1 cells by confocal microscopy. Cells were initially incubated with MORAb-004-Dy405 on ice and then allowed to warm to 37°C. At 4°C, MORAb-004-Dy405 (blue) localized to the cell membrane on MS1-TEM1 cells (Fig. 2A), but there was no binding on MS1 cells (Fig. 2E). Surface binding could be effectively removed after acid wash, showing that signal was restricted to the plasma membrane at 4°C (Fig. 2B). After warming to 37°C for 1 h, strong immunofluorescence was observed on both plasma membrane and in intracellular compartments of MS1-TEM1 cells (Fig. 2C). Internalization of MORAb-004-Dy405 was confirmed by acid wash of MS1-TEM1 cells, where surface-bound mAb was removed but intracellular MORAb-004-Dy405 was still retained (Fig. 2D).
For quantitative assessment of MORAb-004 internalization, MS1-TEM1 cells were incubated with 125I-MORAb-004 and the internalization of MORAb-004 was studied by γ counting (Fig. 3). The fraction of radioactivity that internalized in MS1-TEM1 cells at 2 h at 37°C was approximately 12% of total activity bound and did not change with increasing dose of 125I-mAb added to the medium (0.5–4 nM) (Fig. 3A). The fraction of radioactivity that internalized in MS1-TEM1 cells, with respect to the total amount of 125I-MORAb-004 bound per MS1-TEM1 cell, increased from 15.6% ± 0.7% at 2 h to 23.4% ± 0.9% at 4 h and reached a plateau at 8 h from 32.8% ± 0.8% to 38.6% ± 0.9% at 24 h (Figs. 3B and 3C). Interestingly, in LA1-5s neuroblastoma cells, which endogenously express hTEM1, maximum internalization was achieved at 60 min and remained quite low at less than 10% at all time points thereafter (Supplemental Fig. 3). The uptake of radioactivity was completely blocked by the addition of unlabeled MORAb-004 to the incubation medium, thus demonstrating the requirement of TEM1-specific binding in mediating internalization. Figures 3B and 3C show the internalized and surface-bound fractions over time, with respect to total cell bound radioactivity. The surface-bound fraction of radioactivity was the activity removed from the total bound activity after an acid wash of the cells.
In Vivo Characterization
Biodistribution Studies
In naïve non–tumor-bearing mice, there was a dramatic difference in the blood clearance kinetics of 125I-MORAb-004, as compared with mice bearing ID8 tumor grafts enriched with MS1 or MS1-TEM1 endothelial cells in either flank (Fig. 4; Tables 2 and 3). In naïve mice, the blood-pool activity was 22.39 ± 1.47 percentage injected dose per gram (%ID/g) at 4 h and slowly decreased 4-fold to 5.64 ± 0.50 %ID/g on day 6. Blood-pool activity decreased 25-fold over a 6-d period, from 18.84 ± 0.93 %ID/g at 4 h to 0.74 ± 0.05 %ID/g on day 6. There was slower washout of activity across all major organs, as seen with blood levels, in naïve mice, as compared with tumor-bearing mice. In contrast, uptake in TEM1+ tumor grafts was 153.19 ± 22.24 %ID/g as early as 4 h after injection and remained consistently high out to 3 d after injection, demonstrating retention of the TEM1-targeted antibody. Uptake in TEM1+ tumors decreased to 10.65 ± 1.08 %ID/g at 6 d after injection. Uptake in TEM1-negative (TEM1−) tumor grafts was significantly lower than TEM1+ tumors at all time points, with uptake clearing over time from 8.98 ± 2.48 %ID/g at 4 h to 3.93 ± 1.98 %ID/g at 72 h and 0.67 ± 0.08 %ID/g on day 6. Autoradiography of tumors at 24 h after injection further confirmed the higher uptake of 125I-MORAb-004 in TEM1+ tumors than in the control tumors (Fig. 4C). The tumor-to-blood ratio in TEM1+ grafts increased 4.5-fold from 8.1 to a maximum of 40.6 on day 3. Similarly, the TEM1+-to-TEM1− tumor ratio in ID8 grafts increased 2.7-fold from 18.1 to a maximum of 49.1 on day 3. Target-to-nontarget uptake ratios were decreased by day 6. As an indication of radioiodine metabolism from the antibody, thyroid uptake was also assessed over time. No time-dependent changes in thyroid uptake were observed in both naïve and tumor-bearing mice up to 6 d after injection. Thyroid levels ranged from 0.1% to 1.2 %ID per total organ (%ID/org).
The specificity of TEM1 tumor targeting was demonstrated using an isotype control IgG1. The biodistribution of 125I-IgG1 shows that uptake of the nontargeted IgG is nearly the same between both MS1-TEM1 and MS1 vascularized tumors, with 5.43 ± 0.73 and 5.13 ± 1.86 %ID/g at 24 h after injection, respectively (supplemental materials). The localization ratio of TEM1+ tumor uptake to blood and TEM1− tumor uptake were low for nontargeted IgG1 (generally < 1), indicating a lack of specific uptake.
Pharmacokinetic Analysis
To evaluate the blood pharmacokinetics of 125I-MORAb-004 in naïve versus TEM1+ tumor–bearing nu/nu mice, serum samples were collected and analyzed at defined times (supplemental material). Blood-pool clearance rates were slow for the targeted IgG1 mAb in naïve mice as compared with mice with TEM1+ tumors: the fast α-phase of the biphasic blood clearance was 1.9 versus 1.1 h, respectively, whereas the slower β-phase was 117.9 h in naïve mice, compared with 28.8 h in tumor-bearing mice (R2 = 0.95 and 0.92, respectively). For further comparison, the α- and β-decay rates for blood clearance of the isotype control 125I-IgG1 in tumor-bearing mice were 3.7 and 76.9 h, respectively. These rates were both slower than those for 125I-MORAb-004 in tumor-bearing mice, further demonstrating targeting specificity of 125I-MORAb-004 for TEM1+ tumors.
PET Imaging Studies
Tumor location and volume were first confirmed by in vivo bioluminescence imaging of fLuc reporter gene expression in mice bearing subcutaneous ID8 tumor grafts with MS1-TEM1–expressing vasculature on the left flank and control MS1/ID8 tumor graft on the right flank. 124I-MORAb-004 uptake in tumor grafts was TEM1-specific, as demonstrated by target-blocking experiments performed by coinjecting an excess dose (25 μg) of nonlabeled cold MORAb-004 (Fig. 5B). TEM1+ tumors were poorly visualized throughout the 3-d study period, demonstrating TEM1 specificity of MORAb-004. Images for the remaining mice in the PET study are provided in the supplemental materials. Postmortem tissue sampling of the mice after 72-h PET imaging confirmed the biodistribution data. The tumor uptake of 124I-MORAb-004 was 221.82 ± 57.33 %ID/g in TEM1+ tumor grafts at 72 h after injection and was significantly greater than corresponding tumor uptake of 24.06 ± 3.26 %ID/g at 72 h in mice blocked with excess cold MORAb-004, again confirming radioimmunoconjugate specificity (supplemental material). In contrast, no significant difference in tumor uptake was observed in TEM1 tumor grafts after coinjection with blocking dose of MORAb-004 (Fig. 5B).
DISCUSSION
The tumor vascular marker TEM1/endosialin is emerging as an attractive biomarker for targeted molecular diagnostics and therapeutics because of its expression across many human tumors, low to absent expression in normal tissues, and accessibility from the vascular circulation. Although the molecular function of TEM1 remains unclear, investigators have recently designed IgG antibodies targeting the lectin-like domain of TEM1, which inhibit cell migration (20) and vascular tube formation (9,32,33). Smaller scFv constructs have also been reported for TEM1 targeting of drug-delivery vehicles (19) or diagnostics for fluorescence imaging techniques (17). Although TEM1 is a quasiuniversal tumor target present in the vasculature of many solid tumor types, a variable proportion of tumors—depending on histotype—show low or no TEM1 expression (6). Detection of TEM1 in tumors may facilitate the selection of patients for specific therapies and would allow monitoring of therapeutic effect in real time using immuno-PET (25,34,35). Combined with the ready availability of 124I and its sufficiently long half-life (4.2 d), 124I immuno-PET imaging is an attractive approach to demonstrate quantitative biomarker expression noninvasively. In this work, we describe the detailed preclinical characterization of a novel PET radioimmunodiagnostic humanized anti-TEM1 124I-MORAb-004 IgG1, of which the naked antibody MORAb-004 is currently in trials for cancer immunotherapy.
Direct radioiodination of MORAb-004 did not dramatically alter the functional targeting to MS1 mouse endothelial cells engineered to express recombinant hTEM1 (MS1-TEM1). This is evidenced by the nanomolar affinity, high cellular binding capacity (>105 antibodies bound per cell), and immunoreactivity of 125/124I-MORAb-004. Differences in degree and quality of hTEM1 glycosylation patterns in murine and human cells could potentially overestimate MORAb-004 accessibility and binding to native hTEM1. However, the affinity of 125I-MORAb-004 for native hTEM1 expressed in human neuroblastoma cancer cells is considerably higher than recombinant hTEM1 in murine endothelial cells, suggesting that MORAb-004 accessibility and affinity is sufficiently high for targeting to endogenous hTEM1 in patients. Antibody internalization and intracellular retention are important criteria for assessing the potential of a therapeutic agent being considered for conjugation with a toxin or radioisotope. Fluorescence microscopy of dye-labeled MORAb-004 and radiotracing of 125I-MORAb-004 confirm slow internalization (and radiolabel catabolism ex post facto) in vitro by MS1-TEM1 endothelial cells. Internalization was found to be even slower in human neuroblastoma cells endogenously expressing hTEM1. However, in vitro results may not always be indicative of antibody processing in vivo.
MORAb-004 binds to hTEM1 and does not cross-react with murine TEM1. Hence, we used a chimeric ovarian cancer vascular murine model recently described to assess the targeting of MORAb-004 to hTEM1 TVM (18). In this preclinical model, tumors derived from ID8 ovarian cancer cells enriched with MS1 endothelial cells had increased vascular density, compared with ID8 tumors alone by visual inspection and from quantification of hemoglobin content (data not shown). This increase implies that MS1 cells contribute to the formation of functional tumor vasculature. Further, MS1-TEM1 cells admixed with ID8 cells integrate into the tumor vasculature, as confirmed by immunohistochemical visualization of hTEM1-positive vessels and capillaries (Supplemental Fig. 8).
Biodistribution data with this vascular hTEM1 murine model revealed high uptake of 125I-MORAb-004 (>150 %ID/g at 4 h) in ID8 ovarian tumors with TEM1+ tumor vasculature and no uptake in the contralateral hTEM1− ID8/MS1 tumors. This high degree of targeting to TEM1+ vessels was maintained up to 72 h after injection, with target tumor uptake decreasing on day 6. There was a low extent of thyroid uptake over the course of the biodistribution and PET study (<2 %ID/org). This is consistent with previously reported studies with other radioiodine-labeled mAbs targeting slowly internalizing cell surface markers—including 124I-cG250 IgG mAb for imaging carbonic anhydrase 9 (CAIX) expression (25) and 125I-35A7 IgG mAb, as a radioimmunotherapeutic targeted to carcinoembryonic antigen (CEA) (36). Therefore, we can tentatively conclude that the antibody catabolic rate in vivo is comparable to that seen in vitro. It is plausible that slow intratumoral metabolism and subsequent recirculation of 124I-labeled metabolites may also occur. Full metabolic studies are beyond the scope of the current study and will be the subject of further investigations.
This type of preclinical model is a helpful tool for validating agents specific to human tumor vascular targets in the absence of more relevant knock-in models with the human coding sequence inserted into the mouse locus. Immuno-PET data demonstrate that 124I-MORAb-004 imaging provides high tumor–to–background tissue ratios and that this high uptake is specific for TEM1 expression in tumor tissue. On the basis of the aforementioned in vivo results, 124I-MORAb-004 has favorable pharmacokinetics, with rapid tumor targeting, rapid blood clearance, and fast washout from nontarget tissue. An experimental limitation to our preclinical model is that hTEM1 is exclusively expressed on engineered murine endothelial cells that integrate into the murine tumor vasculature, and so we are only able to assess targeting and tumor retention of MORAb-004 to the most easily accessible tumor vascular compartment. In human tumors, TEM1 is expressed by tumor-associated stromal cells, fibroblasts, and pericytes (7,24,37); various types of cancer cells; and endothelial progenitor cells (6,33). However, IgG can readily cross the leaky basement membrane of tumor vasculature and extravasate into the perivascular space, suggesting that MORAb-004 could bind readily to various cell types presenting surface TEM1 in the tumor microenvironment. Although this model cannot address questions including the temporal regulation of hTEM1 with respect to tumor size or on internalization of the antibody, the recent development of hTEM1 knock-in mice (38) will allow future studies to focus toward that goal.
Overall, the novel radiotracer 124I-MORAb-004 represents a promising candidate for further evaluation and translation to the clinic as an immuno-PET agent for the noninvasive detection of primary and metastatic cancers expressing TEM1 in vivo.
CONCLUSION
The humanized anti-hTEM1 IgG mAb 125/124I-MORAb-004 can be prepared by direct radioiodination, with high radiochemical purity and specific activity, without significant loss of specificity and immunoreactivity to hTEM1-positive cells. In vitro internalization is fairly low and protracted. Biodistribution and 124I immuno-PET in a chimeric hTEM1 mouse tumor model revealed robust TEM1-specific contrast within the tumor vasculature as early as 4 h and up to 6 d after administration. Autoradiography further confirmed microdistribution of 124I-MORAb-004 within TEM1-postitive vascularized tumor tissue. This is the first report, to our knowledge, fully characterizing 124I-MORAb-004 as an immuno-PET diagnostic of noninvasive detection of hTEM1 in a murine tumor vascular network.
DISCLOSURE
The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This work was supported by NIH Transformative R01CA156695 and NIH NCCR and NCATS, through grant KL2TR00139; the Honorable Tina Brozman Foundation; and a grant from the Basser Center at the University of Pennsylvania. No other potential conflict of interest relevant to this article was reported.
Acknowledgments
We thank Eric Blankemeyer of the University of Pennsylvania Small Animal Imaging Facility (SAIF) for excellent technical support.
Footnotes