Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions

Ali Afshar-Oromieh, Henrik Hetzheim, Clemens Kratochwil, Martina Benesova, Matthias Eder, Oliver C. Neels, Michael Eisenhut, Wolfgang Kübler, Tim Holland-Letz, Frederik L. Giesel, Walter Mier, Klaus Kopka and Uwe Haberkorn
Journal of Nuclear Medicine November 2015, 56 (11) 1697-1705; DOI: https://doi.org/10.2967/jnumed.115.161299
Ali Afshar-Oromieh
1Department of Nuclear Medicine, Heidelberg University Hospital, Heidelberg, Germany
2Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Henrik Hetzheim
3Division of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Clemens Kratochwil
1Department of Nuclear Medicine, Heidelberg University Hospital, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martina Benesova
4Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthias Eder
4Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Oliver C. Neels
4Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Eisenhut
4Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wolfgang Kübler
5Division of Radiation Protection and Dosimetry, German Cancer Research Center, Heidelberg, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tim Holland-Letz
6Department of Biostatistics, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frederik L. Giesel
1Department of Nuclear Medicine, Heidelberg University Hospital, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Walter Mier
1Department of Nuclear Medicine, Heidelberg University Hospital, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Klaus Kopka
4Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Uwe Haberkorn
1Department of Nuclear Medicine, Heidelberg University Hospital, Heidelberg, Germany
2Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

PET imaging with the prostate-specific membrane antigen (PSMA)–targeted radioligand 68Ga-PSMA-11 is regarded as a significant step forward in the diagnosis of prostate cancer (PCa). More recently, a PSMA ligand was developed that can be labeled with 68Ga, 111In, 177Lu, and 90Y. This ligand, named PSMA-617, therefore enables both diagnosis and therapy of PCa. The aims of this evaluation were to clinically investigate the distribution of 68Ga-PSMA-617 in normal tissues and in PCa lesions as well as to evaluate the radiation exposure by the radioligand in PET imaging. Methods: Nineteen patients, most of them with recurrent PCa, were referred for 68Ga-PSMA-617 PET/CT. The quantitative assessment of tracer uptake of several organs and of 53 representative tumor lesions was performed in 15 patients at 1 and 3 h after injection. In 4 additional patients, the same procedure was conducted at 5 min, 1 h, 2 h, 3 h, 4 h, and 5 h after injection. On the basis of the data for these 4 patients (mean injected dose, 231 MBq), the radiation exposure of a 68Ga-PSMA-617 PET/CT was identified. Results: Intense tracer uptake was observed in the kidneys and salivary glands. In 14 of 19 patients (73.7%), at least 1 lesion suspected of being a tumor was detected at 3 h after injection. Of 53 representative tumor lesions selected at 3 h after injection, 47 lesions were visible at 1 h after injection. The mean tumor-to-background ratio for maximum standardized uptake value was 20.4 ± 17.3 (range, 2.3–84.0) at 1 h after injection and 38.2 ± 38.6 (range, 3.6–154.3) at 3 h after injection. The average radiation exposure (effective dose) was approximately 0.021 mSv/MBq. Conclusion: Within healthy organs, the kidneys and salivary glands showed the highest 68Ga-PSMA-617 uptake. The radiation exposure was relatively low. 68Ga-PSMA-617 shows PCa lesions with high contrast. Images obtained between 2 and 3 h after injection seem to be the best option with regard to radiotracer uptake and tumor contrast. Later images can help to clarify unclear lesions.

  • prostate cancer
  • PET/CT
  • positron emission tomography
  • PSMA
  • prostate-specific membrane antigen
  • dosimetry

Prostate cancer (PCa) is the most common malignant tumor in men worldwide (1,2). After initial therapy, mainly by surgery or radiation, biochemical recurrence is frequent. At this constellation, searching for tumor relapses and metastases is challenging for conventional imaging modalities such as CT and MR imaging because of the often unsatisfying sensitivity and specificity. As a consequence, there has been the need to develop improved techniques to image PCa. In this context, many groups have focused on the prostate-specific membrane antigen (PSMA) as a promising biologic target for scintigraphic imaging and endoradiotherapy of PCa (3,4). PSMA is a transmembrane protein that is significantly overexpressed in most adenocarcinomas of the prostate gland, compared with other PSMA-expressing tissues. In addition, as already shown in the late 1990s, the neovasculature of many solid tumors also expresses PSMA (5–7).

During the last 2 decades, many efforts have been undertaken to develop PSMA ligands (8–16). One of these ligands, the small-molecule Glu-NH-CO-NH-Lys-(Ahx)-[68Ga(HBED-CC)], also known as PSMA-11, PSMAHBED, Glu-CO-Lys(Ahx)-HBED-CC, DKFZ-PSMA-11, PSMA-HBED-CC, PSMA-HBED, PSMA, or Prostamedix, developed at the German Cancer Research Center Heidelberg (DKFZ), has become the most clinically used radiotracer. This compound shows a strong binding affinity to PSMA and a highly efficient internalization into PCa cells (17,18).

The hitherto existing results of PET/CT imaging with 68Ga-PSMA-11 demonstrate that this method could be a significant step forward in the diagnosis of recurrent PCa (19–23).

Meanwhile, modifications of PSMA-11 have resulted in the development of a novel small-molecule PSMA ligand, PSMA-617. In preclinical studies, this ligand showed a significantly improved binding affinity to PSMA and a highly efficient internalization into PCa cells (24). PSMA-617 can be labeled with 68Ga, 177Lu, 111In, and 90Y and, therefore, be used for PET imaging as well as for radioligand-based therapy. Preclinical assays of PSMA-617 showed inhibition constant (Ki) values of 2.3 ± 2.9 nM, demonstrating a significant improvement, compared with PSMA-11 (12.0 ± 2.8 nM). To our knowledge, PSMA-617 presents one of the highest binding affinities to the PSMA receptor that have been published thus far. In preclinical studies, tumor-to-background ratios of up to 1,058 were observed at 24 h after injection. In addition, the internalization of the PSMA-617 into the PCa cells is highly effective (internalized fraction: 17.67% ± 4.34% injected activity/106 LNCaP cells [PSMA-11, 9.47% ± 2.56% injected activity/106 LNCaP cells]) (18,24).

Since 2013, 177Lu-PSMA-617 has been increasingly used for radioligand therapy of metastatic PCa patients in several centers (to our knowledge, at least in Bad Homburg, Bonn, Cologne, Freiburg, Heidelberg, Istanbul, Melbourne, LMU Munich, and Münster) (25). However, the performance of this novel theranostic substance in the diagnosis of PCa in humans has not yet been evaluated and published. The aim of this evaluation was to clinically investigate the distribution of 68Ga-PSMA-617 in normal tissues and in PCa lesions as well as to evaluate the radiation exposure by the radioligand in PET imaging.

MATERIALS AND METHODS

For this evaluation, we performed a retrospective analysis of 19 patients (Table 1) who underwent 68Ga-PSMA-617 PET/CT to detect tumor lesions in the case of biochemical relapse of PCa, to exclude metastases before initial treatment of PCa, or to evaluate possible treatment with 177Lu-PSMA-617 in progressive disease after multiple pretreatments. The mean age of the patients was 64 ± 8.2 y (range, 47–75 y; median, 66 y); patients had a median Gleason score of 7.0 (range, 5–9). The mean prostate-specific antigen (PSA) level was 5.0 ± 6.4 ng/mL (range, 0.1–24.3 ng/mL; median, 2.9 ng/mL).

View this table:
  • View inline
  • View popup
TABLE 1

Characteristics of All Patients Investigated in This Study

All patients signed a written informed consent form for the purpose of anonymized evaluation and publication of their data. All reported investigations were conducted in accordance with the Helsinki Declaration and with our national regulations (German Medicinal Products Act, AMG §13 2b). This evaluation was approved by the ethics committee of the University of Heidelberg.

Follow-up was conducted until this article was submitted.

Radiotracer

The precursor compound PSMA-617 was produced at the German Cancer Research Center as recently published (24). However, the compound is commercially available from ABX advanced biochemical compounds. The radiopharmaceutical production of 68Ga-PSMA-617 was adjusted to good manufacturing practice compliance as previously described for 68Ga-PSMA-11 (17).

Imaging

Images were obtained with 68Ga-PSMA-617, which was applied via intravenous bolus injection (mean, 203 ± 60 MBq; range, 68–295 MBq; median, 213 MBq). Variation of injected radiotracer activity was caused by the short half-life of 68Ga and by variable elution efficiencies obtained during the lifetime of the 68Ge/68Ga generator. Care was taken that all preparations contained 2 nmol PSMA ligand.

Fifteen patients were investigated with a BIOGRAPH-6 (Siemens). For those patients, an unenhanced CT scan was obtained 1 and 3 h after tracer injection using the following parameters: slice thickness, 5 mm; increment, 0.8 mm; soft-tissue reconstruction kernel; 130 keV and 80 mAs. Immediately after CT scanning, whole-body PET was performed in 3-dimensional mode (matrix, 164 × 164). For each bed position (16.2 cm; overlapping scale, 4.2 cm), a 4-min acquisition time with a 15.5-cm field of view was used. The emission data were corrected for random, scatter, and decay events. Reconstruction was conducted with an ordered-subset expectation maximization algorithm with 2 iterations and 8 subsets and Gauss-filtered to a transaxial resolution of 5 mm in full width at half maximum. Attenuation correction was performed using the low-dose unenhanced CT data.

Image analysis was performed using an appropriate workstation and software (Syngo TrueD; Siemens).

For the 4 patients who were scanned at 6 different times, we used a BIOGRAPH-mCT PET/CT scanner (Siemens). An unenhanced CT scan was obtained at 5 min, 1 h, 2 h, 3 h, 4 h, and 5 h after injection using the following parameters: slice thickness, 5 mm; increment, 2 mm; soft-tissue reconstruction kernel; 120 keV/60 mAs at 3 h after injection and 80 keV/30 mAs at 5 min, 1 h, 2 h, 4 h, and 5 h after injection. Immediately after CT scanning, whole-body PET was performed in 3-dimensional mode (matrix, 200 × 200). Each bed position (axial field of view, 16.2 cm) was acquired for 3 min. The emission data were corrected for random, scatter, and decay events. Reconstruction was conducted with an ordered-subset expectation maximization algorithm with 2 iterations and 8 subsets and Gauss-filtered to a transaxial resolution of 2 mm in full width at half maximum. Attenuation correction was performed using the low-dose unenhanced CT data.

The 2 different PET/CT scanners (BIOGRAPH-6 and BIOGRAPH-mCT) were cross-calibrated.

Image Evaluation

Two board-certified specialists in nuclear medicine with 10 and 27 y of clinical experience interpreted all datasets independently and resolved any disagreement by consensus.

The mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) of lacrimal, parotid, submandibular, and sublingual glands; mediastinal blood pool (aortic arch); and liver, spleen, small proximal bowel, colon, kidneys, and gluteal musculature (as background) were analyzed at 1 and 3 h after injection in 15 patients. In 4 patients, the same procedure was additionally conducted at 5 min, 2 h, 4 h, and 5 h after injection.

With regard to the colon, SUV was measured at the localization with the highest radiotracer uptake, which was usually the descending part.

For calculation of the SUV, circular regions of interest were drawn around areas with focally increased uptake in transaxial slices and automatically adapted to a 3-dimensional volume of interest (VOI) at a 70% isocontour.

SUVs in images acquired at 3 h after injection were compared with those at 1 h after injection and defined as increasing, decreasing, or stable, with intensity changes of greater than 10%, less than −10%, or between −10% and +10%, respectively.

Lesions that were visually considered as suggestive for PCa were counted and analyzed with respect to their localization (local relapses, lymph node [LN], bone, and soft-tissue metastases) and to their SUVmean and SUVmax.

Any visible PCa lesion of a patient was counted and analyzed unless patients had more than 10 lesions. In such a case, a maximum of 10 lesions was analyzed after random selection. This kind of selection avoids an overestimation of SUVs because otherwise-dominant lesions would be preferentially selected.

Tumor contrast was measured by dividing the SUVmean of tumor lesions by the SUVmean of the background (gluteal musculature) and by dividing the SUVmax of tumor lesions by the SUVmax of the background.

Statistical Analysis

The statistical distribution of SUVmean and SUVmax values was assessed visually and by Shapiro–Wilk tests and found to be approximately normal. Thus, SUVs of the above-mentioned organs and of the tumor lesions at 1 and 3 h after injection were compared using a paired-sample t test.

Because PSA levels showed a skewed distribution, a 2-sided Mann–Whitney test was used to evaluate differences concerning PSA values between groups with and without pathologic findings in PET/CT.

A P value of less than 0.05 was considered statistically significant.

Radiation Dosimetry

To find the optimal point of time for the diagnostic examination, the activity distribution of 4 patients was measured at 5 min, 1 h, 2 h, 3 h, 4 h, and 5 h after injection of 68Ga-PSMA-617. The data of these patients were used to estimate the internal radiation dose.

The activity distributions of the source organs were determined with the help of PMOD software (PMOD Technologies), which was used to define the VOIs in the PET images. The VOIs were chosen in the way that the whole activity of the organ was considered. Care needed to be taken to not interfere with the activity concentration of adjacent organs. The number of disintegrations in the organs divided by administered activity was estimated by integration of the time–activity curves of the corresponding VOIs. This is the area under the time–activity curve normalized to the amount of activity administered and is termed residence time in the following sections as it is an established term in internal dosimetry.

After the residence times of the source organs were calculated, the organ doses and the effective dose per unit of administered activity were calculated using the OLINDA/EXM application (version 1.1) (26).

The urinary excretion was also considered. The patients were asked to collect the excreted urine before each PET/CT measurement. The activity of the urine was determined separately. This activity was added to the urinary bladder content calculated from the PET/CT measurements. The excreted activity (decay corrected) was subtracted from the remainder measured at the next PET/CT measurement.

RESULTS

None of the patients developed adverse events or clinically detectable pharmacologic effects. Figure 1 demonstrates the maximum-intensity projection of a patient with normal biodistribution of 68Ga-PSMA-617 at 3 h after injection.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Maximum-intensity projections of patient 4 with normal distribution of 68Ga-PSMA-617 at 3 h after injection. Physiologic accumulation is seen in lacrimal and salivary glands, nasal mucosa, liver, spleen, bowels, and kidneys. Surplus tracer is excreted via urinary tract and urinary bladder. No pathologic tracer uptake was found.

Average SUVmean and SUVmax values of different tissues in all patients analyzed (1 and 3 h after injection) are summarized in Figure 2 and Supplemental Table 1 (supplemental materials are available at http://jnm.snmjournals.org). Intraindividual changes in SUVs between 1 and 3 h after injection (increase, decrease, and stable) were investigated in all patients. The most reproducible trend was registered in the spleen, with almost all patients showing a decrease in radiotracer uptake.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Average SUVmean and SUVmax in different organs 1 and 3 h after injection. Significance of differences between 1 and 3 h (t test): #P < 0.001; *P < 0.05; ∼P > 0.05. Gl. = glandular; Glut. Musc. = gluteal musculature.

A statistically significant increase of SUVmean at 3 h after injection was observed in the following organs: lacrimal glands (+19.5%; P < 0.001), nasal mucosa (+19.2%; P = 0.011), parotid glands (+25.2%; P < 0.001), submandibular glands (+24.2%; P < 0.001), proximal small intestine (+18.4%; P = 0.003), and colon (+13.0%; P = 0.040). SUVmean also increased in the sublingual glands (+7.9%; P = 0.066) and kidneys (+9.9%; P = 0.072), however, without statistical significance.

A statistically significant decrease of SUVmean between 1 and 3 h after injection was observed in the mediastinal blood pool (−5.6%; P = 0.041) and liver (−18.6%; P < 0.001). SUVmean decreased also in the gluteal musculature (−0.8%; P = 0.826), however, without being statistically significant.

A statistically significant increase of SUVmax was detected in lacrimal glands (+34.5%; P = 0.001), nasal mucosa (+27%; P = 0.003), parotid glands (+32.1%; P < 0.001), submandibular glands (+31.3%; P < 0.001), sublingual glands (+19.4%; P < 0.001), proximal small intestine (+33.4%; P < 0.001), colon (+27.3%; P = 0.003), and kidneys (+17.0%; P = 0.002). An increase was also observed in the liver (+7.3%; P = 0.090), without reaching statistical significance.

A statistically significant decrease of SUVmax between 1 and 3 h after injection was observed in the mediastinal blood pool (−12.9%; P = 0.001) and spleen (−11.5%; P = 0.001). SUVmax decreased also in the gluteal musculature (−6.3%; P = 0.331), however, without being statistically significant.

In 14 of 19 patients (73.7%), at least 1 lesion suspected of being a tumor was detected. Figures 3 and 4 and Supplemental Figures 1 and 2 show some representative PCa lesions. Among all lesions visually considered typical for PCa, we selected 53 representative lesions for further analysis (Fig. 5). Of these, 39 were defined as LN metastases (in 8 different patients), 8 as bone metastases (in 2 different patients), 3 as local relapses (in 3 different patients), and 3 as primary tumors (in 2 different patients).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A-C) 68Ga-PSMA-617 PET/CT of patient 11 at 1 h after injection. Red arrows point to a bone metastasis with SUVmax of 21.7 at 1 h and 32.6 at 3 h after injection. (A) Low dose CT. (B) Fusion of PET and CT. (C) MIP of PET/CT. MIP = maximum-intensity projection.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

68Ga-PSMA-617-PET/CT of patient 3 at 1 h (C and D) and 3 h after injection (A and B). Red arrows point to LN (Virchow’s node), which was identified as metastasis in images at 3 h after injection only. In images at 1 h after injection, tracer accumulation was rated as artifact. In this patient, also 4 other LNs (retroperitoneal) were identified as metastases in images at 3 h after injection only. (A) Fusion of PET and CT 3 h after injection. (B) Maximum-intensity projection of PET/CT 3 h after injection. (C) Fusion of PET and CT 1 h after injection. (D) Maximum-intensity projection of PET/CT 1 h after injection.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Average SUVmax in 53 representative PCa lesions and their ratio to background (contrast) 1 and 3 h after injection. Five of overall 8 lesions (lesions 11, 12, 14, 17, and 18) in patient 3 and 1 of overall 2 lesions (lesion 31) patient 16 were not visible in images at 1 h after injection because of low contrast.

As demonstrated by Figure 5 and Supplemental Figure 3, SUVmean and SUVmax increased in 46 and 50 lesions, respectively; decreased in 3 and 2 lesions, respectively; and remained stable in 4 and 1 lesions, respectively, between 1 and 3 h after injection. In patient 3, 5 of overall 8 lesions (Fig. 5, lesions 11, 12, 14, 17, and 18) and in patient 16, 1 of overall 2 lesions (Fig. 5, lesion 31) were not visible in the images at 1 h after injection because of low contrast.

The detailed SUVs of different types of PCa lesions at 1 and 3 h after injection are listed in Table 2. The highest SUVs were measured in bone metastases, followed by LN metastases, local relapses, and primary tumors.

View this table:
  • View inline
  • View popup
TABLE 2

SUVs of Different Types of PCa at 1 and 3 Hours After Injection

Patients without pathologic findings (n = 5) had a mean PSA of 0.5 ± 0.5 ng/mL (range, 0.1–1.3 ng/mL; median, 0.4 ng/mL) and a median Gleason score of 7.0 (range, 7–8) and were injected with a mean of 189 ± 71 MBq of radiotracer (range, 68–255 MBq; median, 237 MBq).

Patients with pathologic findings (n = 14) had a mean PSA of 7.3 ± 6.6 ng/mL (range, 1.3–24.3 ng/mL) and a median Gleason score of 7 (range, 5–9) and were injected with a mean of 196.8 ± 54 MBq of radiotracer (range, 132–295 MBq).

There was no significant difference in Gleason score and injected amount of tracer (activity, measured in MBq) between both groups (with/without pathologic findings in PET/CT). However, PSA levels were significantly lower (P = 0.002) in the group without pathologic findings in the 68Ga-PSMA-617 PET/CT.

Follow-up information was available for 10 patients. Among these, 6 received local treatment: 5 were treated with external radiation of PSMA-positive lesions (all of them demonstrated a decrease of PSA) and 1 was operated on (presented with a decrease of PSA thereafter). Two patients were treated by androgen-deprivation therapy only, and 2 others did not receive any treatment after PET/CT.

The effective dose of 68Ga-PSMA-617 was determined in 4 patients. An average activity of 231 MBq was injected intravenously. Figure 6 presents the uptake and contrast of all tumor lesions in relation to the different times after the injection of PSMA-617. As visible, most PCa lesions show an increase of uptake and contrast by time. Representatively, Figure 7 demonstrates maximum-intensity projections of a sequential PET/CT scan of patient 18 and the corresponding SUVmax of 2 primary PCa lesions.

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Development of SUVs and tumor contrast over time in all bone metastases (n = 7), LN metastases (n = 15), and primary tumors (n = 2) in patients 16–19. met. = metastases.

FIGURE 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7.

(Upper) Maximum-intensity projections of sequential PET/CT scan of patient 18 at different times after injection of 213 MBq of 68Ga-PSMA-617. Blue and red arrows point to 2 primary PCa lesions. (Lower) SUVmax of the 2 primary PCa lesions at the different times. p.i. = after injection.

Table 3 provides the estimated residence times of 68Ga of the selected source organs. The estimated organ doses in Table 4 show that the kidneys and the urinary bladder wall were the organs with the highest dose. As presented also by Table 4, the effective doses for patients 16–19 were 0.021 mSv/MBq ± 15% (maximum deviation), leading to an effective dose of 4.3 mSv for an injected activity of 203 MBq (mean injected activity of the 19 patients).

View this table:
  • View inline
  • View popup
TABLE 3

Dosimetry Data and Residence Times of 68Ga-PSMA-617

View this table:
  • View inline
  • View popup
TABLE 4

Absorbed Organ Doses of 68Ga-PSMA-617 PET

Supplemental Figures 4 and 5 show the decay-corrected radioactivity in the source organs as a function of time. The remainder was in the range of 65%–75% whereas the source organ distributions were of the order of magnitude of 15%. The major contribution resulted from the kidneys, urinary bladder, and liver. The small intestine, upper large intestine, and spleen have been additionally considered as minor radiotracer uptake, with a mostly constant time course.

The activity of the lacrimal and salivary glands was below 2% of the injected activity and was considered in the remainder.

This approach has no effect for the estimation of the effective dose. When PSMA-617 is used with radioligand therapy, the organ doses of lacrimal and salivary glands should be considered individually.

DISCUSSION

The clinical introduction of PET imaging with the PSMA ligand 68Ga-PSMA-11 has been regarded as a significant improvement in the diagnosis of PCa. The hitherto existing results are highly promising and demonstrate that PSMA ligand PET/CT could be superior to other modalities for the diagnosis of recurrent PCa (19–23). However, more recently, 68Ga-PSMA-11 has been structurally modified with the goal to allow labeling with several radiometals such as 68Ga, 111In, 177Lu, and 90Y (24). 177Lu-labeled PSMA-617 is already in use for the treatment of metastatic PCa in multiple centers (25). So far, the performance of this novel PSMA ligand in the diagnosis of PCa in humans has not yet been evaluated. To assess the applicability of tumor imaging with 68Ga-PSMA-617, we evaluated the distribution of this theranostic substance in normal tissues, determined the radiotracer uptake in PCa lesions, and analyzed the radiation exposure of 68Ga-PSMA-617 PET.

PSMA expression and uptake of radiolabeled PSMA ligands, mostly at low levels, has been reported for various normal tissues (21,27–29). In agreement with these data, our analysis demonstrated significant PSMA-617 uptake in the salivary glands and kidneys and to a lesser extent in lacrimal glands, liver, spleen, and bowel as well. In addition, the salivary and lacrimal glands showed a slight increment of radiotracer uptake between early and late images. This uptake is suggestive of radiotracer trapping and has already been shown as contributing to side effects during treatment with radiolabeled PSMA ligands (28). However, in most other organs our data demonstrate relatively stable uptake values between early and late images at levels similar to 68Ga-PSMA-11, with the exception of the kidneys. The PSMA-617 uptake of the kidneys is significantly lower than 68Ga-PSMA-11. Our observation is in accordance with preclinical studies in which a relatively low uptake and a fast clearance of the kidneys could be demonstrated: 113 percentage injected dose per gram at 1 h to 2.13 percentage injected dose at 24 h (24). This lower uptake and faster clearance result in a lower radiation exposure to the kidneys with consecutive advantages for patients who are referred to a PSMA-based radioligand therapy of metastatic PCa.

In addition, it might be hypothesized that the use of the same substance for both therapy and diagnosis can be a further advantage as it maximizes the precision of therapy response evaluation.

Among normal tissues, SUV decreased in the liver and spleen. Because PSMA expression is reported to be low in these organs (27), we hypothesized that radioactivity measured in these tissues partially reflects a blood-pool effect and is washed out as a result of the plasma clearance of the radiotracer. We cannot exclude that the 68Ga-labeled PSMA ligand as a small molecule redistributes from the intravascular compartment to the interstitial space with time, though.

In the preclinical literature, PSMA expression has been described for the proximal small intestine (27,30). However, in agreement with our experiences with PSMA-11, all of our patients additionally showed PSMA-617 uptake in parts of the colon as well. We suggest that uptake in the colon reflects PSMA expression in neuroendocrine cell populations of colonic crypts or physiologic regeneration areas (27). In our study, there was no evidence of radiotracer clearance via the biliary tract. Furthermore, visualization of the gallbladder was not observed.

Radiotracer detection in nasal mucosa could be explained either by PSMA expression in areas of tissue regeneration or by a blood-pool effect.

Within all tumor lesions, bone metastases presented with the highest SUVs, followed by LN metastases, local relapses, and primary tumors. These results have to be interpreted with caution, though, as the number of lesion types is low and as there is a bias with regard to the number of lesions detected in the different patients. Larger studies are necessary to show which type of lesions present with the highest uptake of PSMA-617. However, our analysis of PSMA-11 uptake in 319 patients showed no significant difference of uptake in bone metastases (n = 359) and LN metastases (n = 328) (22).

Our study demonstrates that PCa lesions usually present with sufficient contrast already 1 h after the injection of 68Ga-PSMA-617. However, images at 3 h after injection showed approximately 90% of the PCa lesions with significantly improved tracer uptake (SUVs) and contrast. This higher uptake and contrast resulted in the detection of 6 additional PCa lesions at 3 h after injection, compared with images at 1 h after injection (5 lesions in 1 patient and 1 lesion in another patient). Although these additional lesions did not change the tumor stage of the patients, we suggest obtaining images at times later than 1 h after injection. The increase of PSMA ligand uptake and tumor contrast by time have not only been demonstrated by the dosimetry data of this current study but also by our experiences with 177Lu-PSMA-617 in the radioligand therapy of metastatic PCa (unpublished data of our institute, collected since 2011).

In addition, our previous analysis with PSMA-11 pointed out that most PCa lesions present with higher uptake and contrast in images obtained at 3 h after injection than at 1 h after injection. The higher uptake and contrast were observed in approximately 70% of the lesions (compared with ∼90% when using PSMA-617). In addition, all 65 lesions in all 37 patients of our previous study with 68Ga-PSMA-11 detected at 3 h after injection were already visible at 1 h after injection (21). That is to say, for 68Ga-PSMA-11 obtaining images at 1 h after injection seems to be sufficient.

The above-mentioned results indicate that PSMA-617 presents with slower pharmacokinetics. Also considering the SUVs in Figure 6, we suggest performing PET/CT at 2–3 h after injection of 68Ga-PSMA-617. Images later than 3 h after injection can help to clarify unclear lesions because still many tumor lesions show increasing uptake and contrast at later times (Fig. 6). In this context, radionuclides with longer half-life, for example, 18F, could show some advantages in imaging when used as a radiofluorinated PSMA-617 analog. On the other hand, a fast clearance of the radiolabeled molecule allows early imaging and does not need radionuclides with longer physical half-life. However, when using radiofluorinated PSMA ligands, a 68Ga infrastructure does not need to be set up. In addition, the availability of cyclotron-based 18F is significantly higher than the generator-based 68Ga. Most recently, the team of Martin Pomper introduced an 18F-labeled PSMA ligand, 18F-DCFPyL (14).

Few PCa lesions decreased in SUV and contrast in later images (Fig. 5). Although the reason remains unclear, we speculate that some tumors show a reduced internalization rate of the PSMA ligand. Further studies are mandatory to clarify this observation.

PSMA-negative prostate carcinoma seems to be rare (31,32). Consequently, the question remains why more patients do not present with a pathologic PET/CT in our retrospective analysis. Low or even absent PSMA expression and small tumor lesions could be sufficient explanations as to why not every patient of our collective presented with a pathologic 68Ga-PSMA-617 PET/CT finding.

The question remains which 68Ga-labeled version of PSMA-targeted radioligand, 68Ga-PSMA-11 or 68Ga-PSMA-617, can be more recommended for diagnosing PCa. Usually the clinical routine is designed to conduct different PET scans at 1 h after injection only (e.g., 18F-FDG, DOTA conjugates, PSMA-11, 18F-DOPA). In this context, patients with multiple scans and later images require complex planning as they otherwise would disturb the clinical routine. Therefore, PSMA-11 with its putatively faster clearance provides a clear advantage. It remains unclear if PSMA-617, with its higher binding affinity and internalization, could detect more PCa lesions in a reasonable time window after injection than PSMA-11. Because of the same molecular effects, we believe that both PSMA ligands show also the same specificity for PCa. Overall, a study with a direct intraindvidual comparison between both ligands is mandatory to clarify which ligand is superior. Besides all mentioned considerations, we believe that centers that integrate 68Ga-PSMA-617 into their clinical routine will be able to provide an excellent tool to diagnose PCa with vast scientific possibilities.

One limitation of our presented analysis is the lack of systematic histopathologic investigations of PET-positive lesions. However, since 68Ga-PSMA ligand PET/CT was introduced, the available data indicate that any uptake of PSMA ligands above local background in CT-morphologic-visible lesions is highly specific for PCa and, thus, has to be regarded as PCa unless otherwise proven. In this context, none of the lesions examined for this analysis was unclear: they all were typical for PCa. This statement is also supported by the results of the follow-up: patients who received targeted radiation therapy or lymphadenectomy of PET-positive lesions after the PET/CT all presented with a decrease of PSA.

With regard to the dosimetry analysis, most of the injected activity could be considered to be homogeneously distributed in the remainder. The highest activity accumulation was found in the urinary bladder, the kidneys, and the small intestine. An average effective dose of 0.021 mSv/MBq was estimated. For instance, a low-dose 68Ga-PSMA-617 PET/CT with an administered activity of 203 MBq results in an effective overall dose of 4.3 mSv (PET) + 3.5 mSv (low-dose CT), which equals 7.8 mSv. These results are similar compared with other most recently introduced PSMA ligands (14,33).

CONCLUSION

This analysis presents the biodistribution and tumor uptake of 68Ga-PSMA-617 in patients. Within healthy organs, kidneys and salivary glands demonstrated the highest radiotracer uptake whereas lacrimal glands, liver, spleen, and bowel showed relatively moderate uptake. 68Ga-PSMA-617 shows lesions of PCa with high contrast, especially in late images. Maximum contrast of tumor lesions is usually seen between 3 and 4 h after injection. The radiation exposure of a PET scan with 68Ga-PSMA-617 is approximately 0.021 mSv/MBq.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. The research in this study was funded by a Klaus-Tschira-Foundation grant (no. 00.198.2012). Ali Afshar-Oromieh has received honoraria from Siemens Healthcare for 1 educational talk. No other potential conflict of interest relevant to this article was reported.

Acknowledgments

We express our gratitude to our staff, in particular Kirsten Kunze and Stephanie Biedenstein.

Footnotes

  • Published online Aug. 20, 2015.

  • © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Jemal A,
    2. Bray F,
    3. Center MM,
    4. Ferlay J,
    5. Ward E,
    6. Forman D
    . Global cancer statistics. CA Cancer J Clin. 2011;61:69–90.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Siegel R,
    2. Ma J,
    3. Zou Z,
    4. Jemal A
    . Cancer statistics, 2014. CA Cancer J Clin. 2014;64:9–29.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Mease RC,
    2. Foss CA
    . MG P. PET imaging in prostate cancer: focus on prostate-specific membrane antigen. Curr Top Med Chem. 2013;13:951–962.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Foss CA,
    2. Mease RC,
    3. Cho SY,
    4. Kim HJ,
    5. Pomper MG
    . GCPII imaging and cancer. Curr Med Chem. 2012;19:1346–1359.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Chang SS,
    2. Gaudin PB,
    3. Reuter VE,
    4. O’Keefe DS,
    5. Bacich DJ,
    6. Heston WD
    . Prostate-specific membrane antigen: much more than a prostate cancer marker. Mol Urol. 1999;3:313–320.
    OpenUrlPubMed
  6. 6.
    1. Chang SS,
    2. O’Keefe DS,
    3. Bacich DJ,
    4. Reuter VE,
    5. Heston WD,
    6. Gaudin PB
    . Prostate-specific membrane antigen is produced in tumor-associated neovasculature. Clin Cancer Res. 1999;5:2674–2681.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Chang SS,
    2. Reuter VE,
    3. Heston WD,
    4. Bander NH,
    5. Grauer LS,
    6. Gaudin PB
    . Five different anti-prostate-specific membrane antigen (PSMA) antibodies confirm PSMA expression in tumor-associated neovasculature. Cancer Res. 1999;59:3192–3198.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Tagawa ST,
    2. Milowsky MI,
    3. Morris M,
    4. et al
    . Phase II study of lutetium-177-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 for metastatic castration-resistant prostate cancer. Clin Cancer Res. 2013;19:5182–5191.
    OpenUrlAbstract/FREE Full Text
  9. 9.
    1. Barrett JA,
    2. Coleman RE,
    3. Goldsmith SJ,
    4. et al
    . First-in-man evaluation of 2 high-affinity PSMA-avid small molecules for imaging prostate cancer. J Nucl Med. 2013;54:380–387.
    OpenUrlAbstract/FREE Full Text
  10. 10.
    1. Hillier SM,
    2. Maresca KP,
    3. Femia FJ,
    4. et al
    . Preclinical evaluation of novel glutamate-urea-lysine analogues that target prostate-specific membrane antigen as molecular imaging pharmaceuticals for prostate cancer. Cancer Res. 2009;69:6932–6940.
    OpenUrlAbstract/FREE Full Text
  11. 11.
    1. Maresca KP,
    2. Hillier SM,
    3. Femia FJ,
    4. et al
    . A series of halogenated heterodimeric inhibitors of prostate specific membrane antigen (PSMA) as radiolabeled probes for targeting prostate cancer. J Med Chem. 2009;52:347–357.
    OpenUrlCrossRefPubMed
  12. 12.
    1. Hillier SM,
    2. Maresca KP,
    3. Lu G,
    4. et al
    . 99mTc-labeled small-molecule inhibitors of prostate-specific membrane antigen for molecular imaging of prostate cancer. J Nucl Med. 2013;54:1369–1376.
    OpenUrlAbstract/FREE Full Text
  13. 13.
    1. Banerjee SR,
    2. Pullambhatla M,
    3. Foss CA,
    4. et al
    . 64Cu-labeled inhibitors of prostate-specific membrane antigen for PET imaging of prostate cancer. J Med Chem. 2014;57:2657–2669.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Szabo Z,
    2. Mena E,
    3. Rowe SP,
    4. et al
    . Initial evaluation of [F]DCFPyL for prostate-specific membrane antigen (PSMA)-targeted PET imaging of prostate cancer. Mol Imaging Biol. 2015;17:565–574.
    OpenUrlCrossRefPubMed
  15. 15.
    1. Ray Banerjee S,
    2. Pullambhatla M,
    3. Foss CA,
    4. et al
    . Effect of chelators on the pharmacokinetics of 99mTc-labeled imaging agents for the prostate-specific membrane antigen (PSMA). J Med Chem. 2013;56:6108–6121.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Cho SY,
    2. Gage KL,
    3. Mease RC,
    4. et al
    . Biodistribution, tumor detection, and radiation dosimetry of 18F-DCFBC, a low-molecular-weight inhibitor of prostate-specific membrane antigen, in patients with metastatic prostate cancer. J Nucl Med. 2012;53:1883–1891.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Eder M,
    2. Neels O,
    3. Muller M,
    4. et al
    . Novel preclinical and radiopharmaceutical aspects of [68Ga]Ga-PSMA-HBED-CC: a new PET tracer for imaging of prostate cancer. Pharmaceuticals (Basel). 2014;7:779–796.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Eder M,
    2. Schafer M,
    3. Bauder-Wust U,
    4. et al
    . 68Ga-Complex lipophilicity and the targeting property of a urea-based PSMA inhibitor for PET imaging. Bioconjug Chem. 2012;23:688–697.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Afshar-Oromieh A,
    2. Haberkorn U,
    3. Schlemmer HP,
    4. et al
    . Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience. Eur J Nucl Med Mol Imaging. 2014;41:887–897.
    OpenUrlCrossRefPubMed
  20. 20.
    1. Afshar-Oromieh A,
    2. Zechmann CM,
    3. Malcher A,
    4. et al
    . Comparison of PET imaging with a Ga-labelled PSMA ligand and F-choline-based PET/CT for the diagnosis of recurrent prostate cancer. Eur J Nucl Med Mol Imaging. 2014;41:11–20.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. Afshar-Oromieh A,
    2. Malcher A,
    3. Eder M,
    4. et al
    . PET imaging with a [68Ga]gallium-labelled PSMA ligand for the diagnosis of prostate cancer: biodistribution in humans and first evaluation of tumour lesions. Eur J Nucl Med Mol Imaging. 2013;40:486–495.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Afshar-Oromieh A,
    2. Avtzi E,
    3. Giesel FL,
    4. et al
    . The diagnostic value of PET/CT imaging with the 68Ga-labelled PSMA ligand HBED-CC in the diagnosis of recurrent prostate cancer. Eur J Nucl Med Mol Imaging. 2015;42:197–209.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Eiber M,
    2. Maurer T,
    3. Souvatzoglou M,
    4. et al
    . Evaluation of hybrid 68Ga-PSMA ligand PET/CT in 248 patients with biochemical recurrence after radical prostatectomy. J Nucl Med. 2015;56:668–674.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Benešová M,
    2. Schafer M,
    3. Bauder-Wust U,
    4. et al
    . Preclinical evaluation of a tailor-made DOTA-conjugated PSMA inhibitor with optimized linker moiety for imaging and endoradiotherapy of prostate cancer. J Nucl Med. 2015;56:914–920.
    OpenUrlAbstract/FREE Full Text
  25. 25.↵
    1. Kratochwil C,
    2. Giesel FL,
    3. Eder M,
    4. et al
    . [177Lu]lutetium-labelled PSMA ligand-induced remission in a patient with metastatic prostate cancer. Eur J Nucl Med Mol Imaging. 2015;42:987–988.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Stabin MG,
    2. Sparks RB,
    3. Crowe E
    . OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Silver DA,
    2. Pellicer I,
    3. Fair WR,
    4. Heston WD,
    5. Cordon-Cardo C
    . Prostate-specific membrane antigen expression in normal and malignant human tissues. Clin Cancer Res. 1997;3:81–85.
    OpenUrlAbstract
  28. 28.↵
    1. Zechmann CM,
    2. Afshar-Oromieh A,
    3. Armor T,
    4. et al
    . Radiation dosimetry and first therapy results with a 124I/131I-labeled small molecule (MIP-1095) targeting PSMA for prostate cancer therapy. Eur J Nucl Med Mol Imaging. 2014;41:1280–1292.
    OpenUrlCrossRefPubMed
  29. 29.↵
    HpaF. The Human Protein Atlas website. http://www.proteinatlas.org/search/hpaf. Accessed September 9, 2015.
  30. 30.↵
    1. Maraj BH,
    2. Aldersley MA,
    3. Markham AF
    . Prostate-specific membrane antigen expression in the duodenum: implications in coeliac disease and immunotherapy for prostate cancer. Lancet. 1998;351:1559–1560.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Mannweiler S,
    2. Amersdorfer P,
    3. Trajanoski S,
    4. Terrett JA,
    5. King D,
    6. Mehes G
    . Heterogeneity of prostate-specific membrane antigen (PSMA) expression in prostate carcinoma with distant metastasis. Pathol Oncol Res. 2009;15:167–172.
    OpenUrlCrossRefPubMed
  32. 32.↵
    1. Bostwick DG,
    2. Pacelli A,
    3. Blute M,
    4. Roche P,
    5. Murphy GP
    . Prostate specific membrane antigen expression in prostatic intraepithelial neoplasia and adenocarcinoma: a study of 184 cases. Cancer. 1998;82:2256–2261.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Herrmann K,
    2. Bluemel C,
    3. Weineisen M,
    4. et al
    . Biodistribution and radiation dosimetry for a novel probe targeting prostate specific membrane antigen for imaging and therapy (68Ga-PSMA I&T). J Nucl Med. 2015;56:855–861.
    OpenUrlAbstract/FREE Full Text
  • Received for publication May 23, 2015.
  • Accepted for publication August 4, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 56 (11)
Journal of Nuclear Medicine
Vol. 56, Issue 11
November 1, 2015
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions
Ali Afshar-Oromieh, Henrik Hetzheim, Clemens Kratochwil, Martina Benesova, Matthias Eder, Oliver C. Neels, Michael Eisenhut, Wolfgang Kübler, Tim Holland-Letz, Frederik L. Giesel, Walter Mier, Klaus Kopka, Uwe Haberkorn
Journal of Nuclear Medicine Nov 2015, 56 (11) 1697-1705; DOI: 10.2967/jnumed.115.161299

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions
Ali Afshar-Oromieh, Henrik Hetzheim, Clemens Kratochwil, Martina Benesova, Matthias Eder, Oliver C. Neels, Michael Eisenhut, Wolfgang Kübler, Tim Holland-Letz, Frederik L. Giesel, Walter Mier, Klaus Kopka, Uwe Haberkorn
Journal of Nuclear Medicine Nov 2015, 56 (11) 1697-1705; DOI: 10.2967/jnumed.115.161299
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Renal and Multiorgan Safety of 177Lu-PSMA-617 in Patients with Metastatic Castration-Resistant Prostate Cancer in the VISION Dosimetry Substudy
  • The Hierarchy of SUVs: From Diagnostics to Therapeutics and the Pathway to Effective Theranostics
  • Evaluation of 134Ce/134La as a PET Imaging Theranostic Pair for 225Ac {alpha}-Radiotherapeutics
  • Comparison of 68Ga-PSMA-617 PET/CT and 68Ga-RM2 PET/CT in Patients with Localized Prostate Cancer Who Are Candidates for Radical Prostatectomy: A Prospective, Single-Arm, Single-Center, Phase II Study
  • From Concept to Regulatory Drug Approval: Lessons for Theranostics
  • Antitumor efficacy of 90Y-NM600 targeted radionuclide therapy and PD-1 blockade is limited by regulatory T cells in murine prostate tumors
  • Bringing VISION to Nuclear Medicine: Accelerating Evidence and Changing Paradigms with Theranostics
  • Matched-Pair Comparison of 18F-DCFPyL PET/CT and 18F-PSMA-1007 PET/CT in 240 Prostate Cancer Patients: Interreader Agreement and Lesion Detection Rate of Suspected Lesions
  • Diagnostic Performance of 18F-DCFPyL-PET/CT in Men with Biochemically Recurrent Prostate Cancer: Results from the CONDOR Phase III, Multicenter Study
  • Radiolabeling of PSMA-617 with 89Zr: A Novel Use of DMSO for Radiochemical Yield Enhancement and Preliminary Small-Animal PET Results
  • Current and Emerging Clinical Applications of PSMA PET Diagnostic Imaging for Prostate Cancer
  • Harnessing 64Cu/67Cu for a theranostic approach to pretargeted radioimmunotherapy
  • 68Ga-PSMA PET/CT Combined with PET/Ultrasound-Guided Prostate Biopsy Can Diagnose Clinically Significant Prostate Cancer in Men with Previous Negative Biopsy Results
  • Quantitative and Qualitative Analyses of Biodistribution and PET Image Quality of a Novel Radiohybrid PSMA, 18F-rhPSMA-7, in Patients with Prostate Cancer
  • Theranostics: Leveraging Molecular Imaging and Therapy to Impact Patient Management and Secure the Future of Nuclear Medicine
  • Prospective Comparison of PET Imaging with PSMA-Targeted 18F-DCFPyL Versus Na18F for Bone Lesion Detection in Patients with Metastatic Prostate Cancer
  • Development of Novel PSMA Ligands for Imaging and Therapy with Copper Isotopes
  • Radiation Dosimetry and Biodistribution of 18F-PSMA-11 for PET Imaging of Prostate Cancer
  • Is the Vision of Radioligand Therapy for Prostate Cancer Becoming a Reality? An Overview of the Phase III VISION Trial and Its Importance for the Future of Theranostics
  • Effect of External Cooling on 177Lu-PSMA Uptake by the Parotid Glands
  • Rapid Modulation of PSMA Expression by Androgen Deprivation: Serial 68Ga-PSMA-11 PET in Men with Hormone-Sensitive and Castrate-Resistant Prostate Cancer Commencing Androgen Blockade
  • Albumin-Binding PSMA Ligands: Implications for Expanding the Therapeutic Window
  • PET-CT Cancer Imaging
  • Why Targeting PSMA Is a Game Changer in the Management of Prostate Cancer
  • 18F-DCFPyL PET/CT in the Detection of Prostate Cancer at 60 and 120 Minutes: Detection Rate, Image Quality, Activity Kinetics, and Biodistribution
  • PSMA Ligands for PET Imaging of Prostate Cancer
  • Glu-Ureido-Based Inhibitors of Prostate-Specific Membrane Antigen: Lessons Learned During the Development of a Novel Class of Low-Molecular-Weight Theranostic Radiotracers
  • Dual-Target Binding Ligands with Modulated Pharmacokinetics for Endoradiotherapy of Prostate Cancer
  • Prostate-Specific Membrane Antigen Ligands for Imaging and Therapy
  • 68Ga-PSMA-PET/CT Has a Role in Detecting Prostate Cancer Lesions in Patients with Recurrent Disease
  • 68Ga or 18F for Prostate Cancer Imaging?
  • Type I collagen-targeted PET probe for pulmonary fibrosis detection and staging in preclinical models
  • Preclinical Evaluation and First Patient Application of 99mTc-PSMA-I&S for SPECT Imaging and Radioguided Surgery in Prostate Cancer
  • Predictors of Response to Radioligand Therapy of Metastatic Castrate-Resistant Prostate Cancer with 177Lu-PSMA-617
  • Synthesis and Biologic Evaluation of Novel 18F-Labeled Probes Targeting Prostate-Specific Membrane Antigen for PET of Prostate Cancer
  • The Rise of PSMA Ligands for Diagnosis and Therapy of Prostate Cancer
  • Response and Tolerability of a Single Dose of 177Lu-PSMA-617 in Patients with Metastatic Castration-Resistant Prostate Cancer: A Multicenter Retrospective Analysis
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • prostate cancer
  • PET/CT
  • Positron Emission Tomography
  • PSMA
  • prostate-specific membrane antigen
  • dosimetry
SNMMI

© 2025 SNMMI

Powered by HighWire