Washington University School of Medicine, St. Louis, Missouri
Correspondence: For reprints contact: M. E. Phelps, Div. of Radiation Sciences, The Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 5. Kingshighway, St. Louis, Mo. 63110.
ABSTRACT
A study was carried out to investigate the use of annihilation coincidence detection (ACD) in emission transaxial reconstruction tomography. The ACD was evaluated in terms of spatial resolution and sensitivity with depth, detection efficiency, effect of pulse-height analysis on resolution and efficiency, correction for attenuation, and cold spot contrast. A prototype positron emission transaxial tomograph (PETT) consisting of a hexagonal array of 24 NaI(Tl) detectors employing ACD was constructed. A fast Fourier transform algorithm was employed to generate the reconstructed image. Computer simulations and phantom and animal studies were carried out to demonstrate that this approach yields tomographic radionuclide images that have high resolution and contrast (hot and cold spot) and that are independent of activity above and below the plane examined. The ACD yields a quantitative nuclear medicine imaging device with high detection efficiency. Comparisons are presented between the ACD and the scintillation camera and scanner. Discussion of the possible applications of the PETT in nuclear medicine is included.
This article has been cited by other articles:
![]() |
B. J. Pichler, H. F. Wehrl, and M. S. Judenhofer Latest Advances in Molecular Imaging Instrumentation J. Nucl. Med., June 1, 2008; 49(Suppl_2): 5S - 23S. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Chatziioannou VP-PET: A New Imaging Modality? J. Nucl. Med., March 1, 2008; 49(3): 345 - 346. [Full Text] [PDF] |
||||
![]() |
T. C. Kwee, R. M. Kwee, and R. A. J. Nievelstein Imaging in staging of malignant lymphoma: a systematic review Blood, January 15, 2008; 111(2): 504 - 516. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Z. Ferl, X. Zhang, H.-M. Wu, and S.-C. Huang Estimation of the 18F-FDG Input Function in Mice by Use of Dynamic Small-Animal PET and Minimal Blood Sample Data J. Nucl. Med., December 1, 2007; 48(12): 2037 - 2045. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A.M.S. van Dongen, G. W.M. Visser, M. N. Lub-de Hooge, E. G. de Vries, and L. R. Perk Immuno-PET: A Navigator in Monoclonal Antibody Development and Applications Oncologist, December 1, 2007; 12(12): 1379 - 1389. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Czernin, M. Allen-Auerbach, and H. R. Schelbert Improvements in Cancer Staging with PET/CT: Literature-Based Evidence as of September 2006 J. Nucl. Med., January 1, 2007; 48(1_suppl): 78S - 88S. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Schnall and M. Rosen Primer on Imaging Technologies for Cancer J. Clin. Oncol., July 10, 2006; 24(20): 3225 - 3233. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Weber Positron Emission Tomography As an Imaging Biomarker J. Clin. Oncol., July 10, 2006; 24(20): 3282 - 3292. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. F. Chatziioannou Instrumentation for Molecular Imaging in Preclinical Research: Micro-PET and Micro-SPECT Proceedings of the ATS, December 1, 2005; 2(6): 533 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Verel, G. W.M. Visser, and G. A. van Dongen The Promise of Immuno-PET in Radioimmunotherapy J. Nucl. Med., January 1, 2005; 46(1_suppl): 164S - 171S. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Rohren, T. G. Turkington, and R. E. Coleman Clinical Applications of PET in Oncology Radiology, May 1, 2004; 231(2): 305 - 332. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. E. Latchaw, H. Yonas, G. J. Hunter, W. T.C. Yuh, T. Ueda, A. G. Sorensen, J. L. Sunshine, J. Biller, L. Wechsler, R. Higashida, et al. Guidelines and Recommendations for Perfusion Imaging in Cerebral Ischemia: A Scientific Statement for Healthcare Professionals by the Writing Group on Perfusion Imaging, From the Council on Cardiovascular Radiology of the American Heart Association Stroke, April 1, 2003; 34(4): 1084 - 1104. [Full Text] [PDF] |
||||
![]() |
A. A. Lammertsma Myocardial Perfusion in 3 Dimensions J. Nucl. Med., August 1, 2002; 43(8): 1041 - 1043. [Full Text] [PDF] |
||||
![]() |
J. Mazziotta, A. Toga, A. Evans, P. Fox, J. Lancaster, K. Zilles, R. Woods, T. Paus, G. Simpson, B. Pike, et al. A Four-Dimensional Probabilistic Atlas of the Human Brain J. Am. Med. Inform. Assoc., September 1, 2001; 8(5): 401 - 430. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. T. Weinzapfel and G. D. Hutchins Automated PET Attenuation Correction Model for Functional Brain Imaging J. Nucl. Med., March 1, 2001; 42(3): 483 - 491. [Abstract] [Full Text] |
||||
![]() |
M. E. Phelps Inaugural Article: Positron emission tomography provides molecular imaging of biological processes PNAS, August 1, 2000; 97(16): 9226 - 9233. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Gambhir, E. Bauer, M. E. Black, Q. Liang, M. S. Kokoris, J. R. Barrio, M. Iyer, M. Namavari, M. E. Phelps, and H. R. Herschman A mutant herpes simplex virus type 1 thymidine kinase reporter gene shows improved sensitivity for imaging reporter gene expression with positron emission tomography PNAS, March 14, 2000; 97(6): 2785 - 2790. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. J. Potchen Reflections on the Early Years of Nuclear Medicine Radiology, March 1, 2000; 214(3): 623 - 629. [Abstract] [Full Text] |
||||
![]() |
R. E. Coleman, C. M. Laymon, and T. G. Turkington FDG Imaging of Lung Nodules: A Phantom Study Comparing SPECT, Camera-based PET, and Dedicated PET Radiology, March 1, 1999; 210(3): 823 - 828. [Abstract] [Full Text] |
||||
![]() |
J. E. Udelson Steps Forward in the Assessment of Myocardial Viability in Left Ventricular Dysfunction Circulation, March 10, 1998; 97(9): 833 - 838. [Full Text] [PDF] |
||||
![]() |
H. Chugani and M. Phelps Maturational changes in cerebral function in infants determined by 18FDG positron emission tomography Science, February 21, 1986; 231(4740): 840 - 843. [Abstract] [PDF] |
||||
![]() |
M. Phelps and J. Mazziotta Positron emission tomography: human brain function and biochemistry Science, May 17, 1985; 228(4701): 799 - 809. [Abstract] [PDF] |
||||
![]() |
H. Wagner Jr, H. Burns, R. Dannals, D. Wong, B Langstrom, T Duelfer, J. Frost, H. Ravert, J. Links, S. Rosenbloom, et al. Imaging dopamine receptors in the human brain by positron tomography Science, September 23, 1983; 221(4617): 1264 - 1266. [Abstract] [PDF] |
||||
![]() |
J Engel Jr, D. Kuhl, and M. Phelps Patterns of human local cerebral glucose metabolism during epileptic seizures Science, October 1, 1982; 218(4567): 64 - 66. [Abstract] [PDF] |
||||
![]() |
G. L. Brownell, T. F. Budinger, P. C. Lauterbur, and P. L. MCGeer Positron Tomography and Nuclear Magnetic Resonance Imaging Science, February 5, 1982; 215(4533): 619 - 626. [Abstract] [PDF] |
||||