Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Reconstruction using Depth of Interaction Information of Curved and Flat Detector Designs for Quantitative Multi-Pinhole Brain SPECT

Benjamin Auer, Kesava Kalluri, Jan De Beenhouwer, Kimberly Doty, Navid Zeraatkar, Phillip Kuo, Lars Furenlid and Michael King
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 103;
Benjamin Auer
1University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kesava Kalluri
1University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jan De Beenhouwer
2University of Antwerp Wilrijk Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kimberly Doty
3Optical Sciences University of Arizona Tucson AZ United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Navid Zeraatkar
1University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Phillip Kuo
4University of Arizona College of Medicine Tucson AZ United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lars Furenlid
3Optical Sciences University of Arizona Tucson AZ United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael King
1University of Massachusetts Medical School Worcester MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

103

Objectives: Brain SPECT has many clinical applications, especially for cerebral blood flow and dopamine transporter imaging [1,2]. In this context, a dedicated brain imaging, multi-pinhole system, AdaptiSPECT-C, is being developed by our group. Recent studies in cardiac and small animal imaging have demonstrated that the use of curved detector could improve image quality, by reducing parallax errors due to the depth of interaction (DOI) effect [3,4]. In this simulation study, we proposed to investigate using reconstruction with DOI modeling the potential advantage in imaging performance of curved over flat detectors for 123I-IMP perfusion imaging using the AdaptiSPECT-C system. Methods: The AdaptiSPECT-C design used in this work consists of 26 detector modules, 158 by 158 mm2 in size, arranged around the patient’s head in three rings. The simulated detector modules were composed of a 8 mm thick NaI(Tl) crystal coupled to a 5 cm thick back-scattering compartment, representing components behind the crystal, to model 123I down-scatter interactions. Each detector module is associated with a 1.36 mm radius direct knife-edge pinhole aperture collimator. Two different system designs were considered, one based on curved detectors, and the other on flat detectors. The curved detectors were designed so that the radius of curvature corresponds to the detector to system center distance (e.g. 30.5 cm). This distance was the same for the flat detectors. GATE simulation [5] was employed to compute the system matrix [6,7] for both detector designs by forming the system response for the activity within each three-dimensional image-voxel of a 24 cm diameter sphere, thus including DOI variations and corrections in reconstruction [6,7]. An XCAT brain phantom [8] emulating 123I-IMP perfusion source distribution was simulated using the two designs. Data were acquired following three scenarios: noise free case (S1), equal number of counts comparison (S2) (e.g. 5.5M detected counts [9]), and equal imaging time comparison for the typical scan time (e.g. 30 min [10]) (S3). For S3, the total number of counts for the curved and flat detector designs, were respectively 9.24M and 9.17M. Projections were reconstructed with 3D-MLEM into images of 1203 voxels of (2 mm)3 and reconstruction compared to the ground truth image. The normalized root mean squared error (NRMSE) as well as percentage of activity recovery (%AR) for several brain regions were used to evaluate the image quality. Results: Only a small gain in volumetric sensitivity (~0.8%) was obtained with the curved detector design. Qualitatively, the reconstructions for the curved and flat detector designs appear similar for all the 3 noise scenarios. Differences are mostly for the peripheral regions of the head where the differences in the obliquity of the gamma-rays passing through the apertures would be the greatest. Due to lower activity, those regions are also more impacted by noise. Quantitatively, a slight NRMSE improvement using curved detectors was seen. The curved detector design leads on average to the best ARs, especially for the striatum and putamen. Regions at the edges of the brain (e.g. cortex and cerebellum), more impacted by DOI effect, are similarly recovered by the two designs. Conclusion: We demonstrated that using curved instead of flat detector for AdaptiSPECT-C with solely centered pinholes leads to small improvement in sensitivity and image quality based on visual inspection, NRMSE, and activity recovery analysis. Flat detector associated with a sophisticated DOI correction was found to lead to similar results than those obtained with the curved detector. Further investigation will be performed using additional pinholes irradiating the 4 quadrants of the detectors which will increase the obliquity of the rays striking the detectors and may thus result in larger difference. Research Support: Grant No R01 EB022521 (NIBIB).

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reconstruction using Depth of Interaction Information of Curved and Flat Detector Designs for Quantitative Multi-Pinhole Brain SPECT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Reconstruction using Depth of Interaction Information of Curved and Flat Detector Designs for Quantitative Multi-Pinhole Brain SPECT
Benjamin Auer, Kesava Kalluri, Jan De Beenhouwer, Kimberly Doty, Navid Zeraatkar, Phillip Kuo, Lars Furenlid, Michael King
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 103;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Reconstruction using Depth of Interaction Information of Curved and Flat Detector Designs for Quantitative Multi-Pinhole Brain SPECT
Benjamin Auer, Kesava Kalluri, Jan De Beenhouwer, Kimberly Doty, Navid Zeraatkar, Phillip Kuo, Lars Furenlid, Michael King
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 103;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
Show more Physics, Instrumentation & Data Sciences

Attenuation, Scatter and Resolution Compensation (PET & SPECT)

  • Attenuation Correction for Amyloid PET Imaging Using Deep Learning Based on 3D UTE/Multi-Echo Dixon MR images
  • Clinical evaluation of Poisson maximum likelihood-based scatter subtraction for 68Ga-PSMA imaging
Show more Attenuation, Scatter and Resolution Compensation (PET & SPECT)

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire