Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleRadiochemistry

Production of 15O for Medical Applications via the 16O(γ,n)15O Reaction

Stacy L. Queern, Ryan Cardman, Christopher S. Loveless, Matthew R. Shepherd and Suzanne E. Lapi
Journal of Nuclear Medicine March 2019, 60 (3) 424-428; DOI: https://doi.org/10.2967/jnumed.118.215681
Stacy L. Queern
1Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama
2Department of Chemistry, Washington University in St. Louis, St. Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ryan Cardman
3Department of Physics, Indiana University, Bloomington, Indiana
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christopher S. Loveless
1Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama
2Department of Chemistry, Washington University in St. Louis, St. Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthew R. Shepherd
3Department of Physics, Indiana University, Bloomington, Indiana
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Suzanne E. Lapi
1Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama
2Department of Chemistry, Washington University in St. Louis, St. Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

15O (half-life, 122 s) is a useful radionuclide for PET applications. Current production of 15O typically makes use of the 14N(d,n)15O, 15N(p,n)15O, or 16O(p,pn)15O reactions using an accelerator. A novel approach for the production of 15O is via the 16O(γ,n)15O reaction using an electron linear accelerator. Photonuclear reactions using an electron linear accelerator may allow for feasible and economical production of 15O compared with the current methods. Methods: In this work, experiments using a repurposed Clinac were conducted using oxygen-containing alumina as a target material to study the production rate of 15O. Additional studies were conducted using a water target cell. Simulations using Geant4 were conducted to predict the activity and power dissipation in the target. Results: Bremsstrahlung radiation from the electron beam, and consequently 15O production via photonuclear reactions, is enhanced when a high-Z material, tungsten, is placed in front of the target. The alumina irradiations provided preliminary data to optimize the beam parameters and target configuration. The optimal thickness of tungsten was 1.4 mm for both the simulated and the measured studies of alumina. Simulations of irradiated water targets showed that tungsten thicker than 1.4 mm resulted in fewer photons available to activate the water; thus, a higher current was required to achieve a fixed dose. Alternatively, for a constant tungsten thickness, more power was deposited in the target with increasing beam energy, requiring a lower current to achieve a fixed dose. Actual irradiations of a water target yielded a quantity of 15O in the water that was consistent with expectations based on irradiations of alumina. Conclusion: Several parameters should be considered regarding the photonuclear production of 15O for an average patient dose of 1,850 MBq (50 mCi) in 10 mL. This work illustrates a variety of machine parameters capable of achieving a reasonable patient dose. Our simulations show that the power deposited in the target for these parameters is less than that in commercially operated cyclotron targets for the production of 18F. Thus, this work demonstrates that the photonuclear production of 15O may be a new production path for this useful radionuclide.

  • molecular imaging
  • radiochemistry
  • oxygen-15
  • positron emission tomography
  • eLINAC
  • photonuclear

The radionuclide 15O is a positron emitter with a half-life of 122.24 s. The versatility and simplicity of the chemical forms of 15O (15O-O2, 15O-CO, 15O-CO2, and, perhaps most importantly, 15O-H2O) combined with its large fraction of positron decay have led to numerous uses in PET imaging research (1–3). It has been used for applications in neurology, cardiology, and oncology to evaluate oxygen consumption, lung perfusion, blood distribution, blood flow, and myocardial perfusion using 15O-H2O (1–5). Current means for the production of 15O typically require a proton or deuteron accelerator, with the most common pathway of production being via the 14N(d,n)15O reaction using a nitrogen gas target and producing 15O in the form of 15O-O2 or 15O-H2O (1,3,4). Production of 15O with protons has also been described using the reactions 15N(p,n)15O or 16O(p,pn)15O (1,4). For various applications, 15O can be converted to 15O-CO or other forms with rapid, online gas-phase chemistry.

A novel approach for the production of 15O is via the 16O(γ,n)15O reaction using an electron linear accelerator (eLINAC). Photonuclear reactions using an eLINAC may allow for low-cost 15O production compared with the current methods (6–8). The eLINAC method induces nuclear reactions (typically (γ,n) or (γ,p)) using bremsstrahlung radiation produced from high-energy electrons incident on a high-Z material (6,7,9). Conceptually, this route may allow for nearly direct use of the bombarded material after irradiation. The bolus could also be piped to a PET/CT installation some distance from the eLINAC or transported by a pneumatic transfer system.

The excitation function for the 16O(γ,n)15O reaction shown in Figure 1 illustrates an optimal energy range for production using 20- to 30-MeV photons to make use of the largest production cross-section of 15O while considering the power deposition in the target. Electron energies of greater than 30 MeV are required to produce photons in the range of 20–30 MeV via bremsstrahlung radiation.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Excitation function for 16O(γ,n)15O (12–13).

Herein we report on initial studies investigating yield and the feasibility of production of 15O via the photonuclear route. Initial simulations and experiments were conducted using alumina as an oxygen-containing target material to determine optimal machine settings and to inform target design. After these experiments, additional irradiation studies were conducted using a water target cell. Simulations of 15O production with different configurations of a water cell, different converter thicknesses, and varying beam energies were conducted.

MATERIALS AND METHODS

Materials

Tungsten was purchased from Midwest Tungsten Service with a thickness of 0.28 mm, alumina was purchased from McMaster-Carr with a thickness of 3 mm and a density of 2.0 g/cm3, and glass shell vials were purchased from Fisher Scientific. All materials were machined locally at Indiana University’s machine shop. Tungsten and alumina were cut into 1.27-cm squares.

Instrumentation

A Clinac (2100; Varian) was used for all irradiations. The target holder and targets were produced at the Indiana University onsite machine shop. A target holder was fabricated such that it mated to fixtures used for holding beam-shaping filters inside the machine. This design allowed for the placement of target materials very near the exit aperture of the accelerator. Therefore, the full electron beam current was directed onto a millimeter-sized spot on the target, permitting a much larger beam flux on target than if target materials were placed at the machine iso-center, where radiotherapy patients are typically placed. Our system implemented a high-Z material (tungsten) as an electron converter, which enhances the production of photons via bremsstrahlung radiation as the electrons interact with the converter. Various thicknesses of tungsten were examined. The average current of the machine, which has a pulsed-beam structure, was calibrated using an open-air alternating current transformer fabricated by Bergoz Instrumentation and mounted in the same location as the target holder.

After irradiation, each target was measured using a calibrated high-purity germanium detector (Canberra) and the data were analyzed to determine the amount of 15O produced. For each spectrum, it was assumed that the annihilation photons from the positrons from 15O decay are the only contributor to the 511-keV peak. The 511-keV peaks were integrated and corrected for decay during acquisition to determine the activity at the start of the acquisition. Multiple acquisitions were collected in series on the same sample. The activity at the start of the acquisition was then plotted against the time since beam off and fit to an exponential decay function with 2 parameters: half-life and activity at beam off.

As we were limited to maximum beam currents of about 5 μA and electron beam energies of 22 MeV, we relied on computer simulations to explore machine configurations that are beyond these limits and better suited for efficient 15O production. A computer model of the target geometry and material was constructed in the Geant4 simulation framework (10–12). The Geant4 code was then used to track the propagation of the electron beam and the subsequent production of bremsstrahlung photons in the target material. The bremsstrahlung spectrum and photon pathlength in the material, as simulated by Geant4, was then used to calculate the 15O activity using the cross-section depicted in Figure 1.

Production of 15O in Alumina

Initial simulations and experiments were conducted using alumina (Al2O3) in the form of ceramic tiles as an oxygen-containing target material. Alumina offered many beneficial features for these preliminary studies, such as the similarity between the oxygen nuclear density of alumina (3.54 × 1019 oxygen atoms/mm3) and water (3.34 × 1019 oxygen atoms/mm3). Alumina also has good machinability, and low activation for other byproducts to be produced via photonuclear routes, allowing for the alumina to provide a workable proxy for a water target.

Several irradiations were completed using alumina to investigate the activity produced with varying tungsten converter thicknesses. The different thicknesses studied for the converter included 0.84, 1.4, 1.68, 1.96, 2.24, 2.52, and 3.64 mm. Corresponding simulations of similar target geometries and beam properties were conducted to validate aspects of the simulation using the experimentally determined activity.

Production of 15O in Water

Three different cylindric water targets were used in the simulations with 3 different volumes as shown in Figure 2. These configurations provided different material depths, different radii, and different volumes to be investigated. Each of these targets was simulated with electron beam energy of 22, 25, 30, and 40 MeV and an electron current of 0.5 μA. These simulations were completed to calculate the activity produced and power dissipation in each target for 5-min irradiations. Target 1 was used in further simulations with varying converter thicknesses of 1.4, 4, 7, and 10 mm and electron energies of 25, 30, and 40 MeV, with the current being adjusted to give a final 15O yield of 1,850 MBq (50 mCi). Thus, these experiments determined the current required to obtain a fixed activity for various converters and the activity per power dissipation relationship as a function of converter thickness.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Water target configurations for the Geant4 simulations.

After the simulations, irradiations were conducted using a water target to verify the yields of 15O produced compared with alumina and to determine whether the produced 15O remained in the water. A small glass cell was constructed with a 12.7-mm diameter and 4.4-mm length holding a volume of 0.5 mL of water. Several irradiations were completed with the water target using a converter thickness of 1.4 mm and a duration of 5 min. After irradiation, the cell was opened and the irradiated water was transferred to a new vial for measurement to omit activated oxygen in the glass vial itself.

RESULTS

Production of 15O in Alumina

Figure 3 shows the Geant4 simulation results and the measured irradiated alumina for 15O. Although this figure shows that the simulations disagreed by about a factor of 2 compared with the measured activity, the trend illustrates that a converter thickness of 1.4 mm for both the simulated and the measured studies yields the maximum produced activity. This trend can be understood as follows. Initially, increasing the converter thickness enhances the bremsstrahlung radiation, and hence activity, as expected. However, as the thickness is further increased, absorption of radiated high-energy photons begins to become significant and flux reaching the target is diminished, thereby reducing the activity for thicker converters. These competing effects generate an optimum thickness for maximum activity, which appears to be accurately predicted by the simulation. There are systematic uncertainties in both predicting and measuring the absolute activity: cross section (13,14), distribution of energy of beam particles, stability of the machine current, conversion efficiency of emitted positrons, and subsequent detection efficiency of 511-keV photons. These systematic uncertainties almost completely cancel in measuring ratios of activities, giving confidence in our ability to predict relative activity between various target configurations and hence optimize the target geometry. A systematic uncertainty about the prediction of absolute activity at the level of a factor of 2 is sufficient to assess the feasibly of this production route.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Measured and calculated activity vs. tungsten thickness for alumina.

Production of 15O in Water

Simulations of the 3 target configurations from Figure 2 are shown in Figure 4 for each water target. The simulation for each target used a 1.4-mm-thick tungsten converter and a 0.5-μA current for a 5-min irradiation, and the electron beam energy was varied with energies of 22, 25, 30, and 40 MeV. The simulation showed target 1 to have the most relevant working profile because of the reasonable volume (6.28 mL) and larger activity produced; therefore, further simulations were conducted with this target. The studies with alumina indicated an optimal converter thickness to maximize activity. However, in the case of a water target, one may also be interested in minimizing target heating to reduce the practical challenge of avoiding target boiling. Although activity is produced by high-energy bremsstrahlung photons, target heating tends to be dominated by the more copious low-energy electrons and positrons produced in the interaction with the converter. As the target thickness is increased, the components of the electromagnetic shower that produce mainly heating are absorbed at a different rate than those that produce activity, leading to a variation of activity per unit energy deposited in the target. To explore this dependence, we simulated other thicknesses beyond that which produced maximum activity. Converters less than 1.4 mm thick yielded both reduced activity and a larger power dissipation in the target than those at 1.4 mm and, hence, appeared to have no practical advantage in either enhancing produced activity or reducing thermal load on the target. For each simulation, the simulated duration of irradiation was 5 min while the current was adjusted to yield an end-of-irradiation radioactivity of 1,850 MBq (50 mCi). The beam energy was varied with energies of 25, 30, and 40 MeV. Table 1 displays these calculations for different converter thicknesses.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Amount of predicted activity produced in the target for several water target geometries.

View this table:
  • View inline
  • View popup
TABLE 1

Geant4 Simulations for the Target 1 Water Configuration to Produce 1,850 MBq (50 mCi) in 5 Minutes with Varying Parameters

Several trends can be seen in Table 1. As a thicker converter (>1.4 mm) is used, an increased current is required to obtain the desired 1,850 MBq (50 mCi), but less power is deposited in the target. As the beam energy increases for the same converter thickness, a lower current is required to achieve 1,850 MBq (50 mCi). It should be noted that, for a specific converter thickness and beam energy, the values in the table (required beam current, power dissipation in target, and total beam power) scale directly for different amounts of radioactivity by multiplying the ratio of radioactivity of interest to the radioactivity used in the Table (1,850 MBq). Simulations using Geant4 yielded a maximum power dissipation in the target of 200.6 W for a current of 63.3 μA and a 25-MeV beam energy to produce 1,850 MBq (50 mCi). For reference, the power dissipation for a proton beam in a typical 18O-H2O target to produce 18F is 900 W for a current of 50 μA and an 18-MeV beam energy. This is much higher than the photonuclear reaction power dissipation. Thus, cooling strategies are available for the proposed water target for photonuclear 15O production based on previous work for similar volumes for high-power 18F production water targets (15,16).

Five-minute experimental irradiations of the water cell were conducted using a 1.4-mm tungsten converter with 22-MeV beam energy and a 0.5-μA current. The series of activity measurements as a function of time since beam off was fit to an exponential decay curve as seen in Figure 5. These results illustrate that the half-life of our produced radioactivity matches the half-life of 15O. The produced amount is comparable to that produced in alumina studies, which used a material with a similar oxygen atom density and geometry. This finding indicates that the bulk of the activated oxygen remains in the water.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Measured activity of the 15O from the water target.

DISCUSSION

The simulated activity of alumina targets for different converter thicknesses allowed for converter thickness to be optimized, producing the maximum amount of activity. The alumina irradiations with the Clinac allowed for the activity to be measured and for the optimal converter configuration to be determined. The optimal converter thickness for this configuration both simulated and experimentally was found to be 1.4 mm of tungsten, validating the ability of the simulation as a tool to optimize target geometry.

Although measurements and simulation deviated somewhat on absolute quantity of activity, good agreement was achieved with respect to relative activity, indicating that the simulations provide a guide to the expected trends of power deposition and activity as a function of tungsten converter thickness. Geant4 simulations illustrated that significant amounts of 15O were achievable using photon-induced nuclear reactions with the available eLINAC and allow for calculations of what parameters would be required to produce clinically useful amounts. The measured water target irradiations show that the 15O produced was radionuclidically pure, with measurable amounts of activity that allow extrapolation to patient doses.

Several parameters for the photonuclear production of 15O in water should be considered to optimize the production of patient doses. An average patient dose is 1,850 MBq (50 mCi) in a volume of 10 mL diluted in saline (17), and hence Table 1 indicates a variety of configurations that all produce a 1,850-MBq (50 mCi) dose in the target 1 geometry, which appears to have a reasonable volume and shape. Two trends are evident in Table 1. First, for a fixed converter thickness, increasing the beam energy decreases the total beam power required to achieve fixed activity. Second, for a fixed beam energy, increasing the converter thickness (>1.4 mm) decreases the power dissipation in the target but increases the total beam power requirement to achieve a fixed activity. An optimal configuration is likely to depend on engineering considerations that place constraints on the beam energy, beam power, or power dissipation in target. The specifications of existing commercial targets indicate that the power dissipation in the target for the photonuclear reactions is such that the required cooling for the proposed photonuclear targets should be achievable. Although the threshold energies for other radionuclidic products that may be produced such as 14O and 13N are 28.9 MeV and 33.5 MeV, respectively, the cross-sections for these reactions are less than 0.2 mb for energies up to 89 MeV (18,19). These low cross-sections should help maintain a relatively radionuclidically pure final product of 15O.

CONCLUSION

Overall, our work illustrates that the production of 15O using a photon-induced nuclear reaction is a promising production method. It may allow for a more straightforward and feasible means of developing 15O onsite for facilities not equipped with a cyclotron.

DISCLOSURE

This research was partially funded by the Indiana University Vice Provost for Research through the Faculty Research Support Program. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Sep. 20, 2018.

  • © 2019 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Van Naemen J,
    2. Monclus M,
    3. Damhaut P,
    4. Luxen A,
    5. Goldman S
    . Production, automatic delivery and bolus injection of [15O]water for positron emission tomography studies. Nucl Med Biol. 1996;23:413–416.
    OpenUrlPubMed
  2. 2.
    1. Inomata T,
    2. Fujiwara M,
    3. Iida H,
    4. Kudomi N,
    5. Miura I
    . Neutron reduction of the small cyclotron for production of oxygen-15-labeled gases. Int Congr Ser. 2004;1265:97–100.
    OpenUrl
  3. 3.↵
    1. Mackay DB,
    2. Steel CJ,
    3. Poole K,
    4. et al
    . Quality assurance for PET gas production using the Cyclone 3D oxygen-15 generator. Appl Radiat Isot. 1999;51:403–409.
    OpenUrl
  4. 4.↵
    1. Powell J,
    2. O’Neil JP
    . Production of [15O]water at low-energy proton cyclotrons. Appl Radiat Isot. 2006;64:755–759.
    OpenUrlPubMed
  5. 5.↵
    1. Harms HJ,
    2. Nesterov SV,
    3. Han C,
    4. et al
    . Comparison of clinical non-commercial tools for automated quantification of myocardial blood flow using oxygen-15-labelled water PET/CT. Eur Heart J Cardiovasc Imaging. 2014;15:431–441.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Howard S,
    2. Starovoitova VN
    . Target optimization for the photonuclear production of radioisotopes. Appl Radiat Isot. 2015;96:162–167.
    OpenUrl
  7. 7.↵
    1. Mamtimin M,
    2. Harmon F,
    3. Starovoitova VN
    . Sc-47 production from titanium targets using electron linacs. Appl Radiat Isot. 2015;102:1–4.
    OpenUrl
  8. 8.↵
    1. Talamo A,
    2. Gohar Y
    . Production of medical radioactive isotopes using KIPT electron driven subcritical facility. Appl Radiat Isot. 2008;66:577–586.
    OpenUrlPubMed
  9. 9.↵
    1. Rane S,
    2. Harris JT,
    3. Starovoitova VN
    . 47Ca production for 47Ca/47Sc generator system using electron linacs. Appl Radiat Isot. 2015;97:188–192.
    OpenUrl
  10. 10.↵
    1. Agostinelli A,
    2. Allison J,
    3. Amako K,
    4. et al
    . GEANT4: a simulation toolkit. Nucl Instrum Methods Phys Res A. 2003;506:250–303.
    OpenUrlCrossRef
  11. 11.
    1. Allison J,
    2. Amako K,
    3. Apostolakis J,
    4. et al
    . Geant4 developments and applications. IEEE Trans Nucl Sci. 2006;53:270–277.
    OpenUrlCrossRef
  12. 12.↵
    1. Allison J,
    2. Amako K,
    3. Apostolakis J,
    4. et al
    . Recent developments in Geant4. Nucl Instrum Methods Phys Res A. 2016;835:186–225.
    OpenUrl
  13. 13.↵
    1. Bramblett RL,
    2. Caldwell JT,
    3. Harvey RR,
    4. Fultz SC
    . Photoneutron cross sections of Tb159 and O16. Phys Rev. 1964;133:B869–B873.
    OpenUrl
  14. 14.↵
    1. Caldwell JT,
    2. Bramblett RL,
    3. Berman BL,
    4. Harvey RR,
    5. Fultz SC
    . Cross sections for the ground- and excited-state neutron groups in the reaction O16(y, n)15O. Phys Rev Lett. 1965;15:976–979.
    OpenUrl
  15. 15.↵
    1. Peeples JL,
    2. Stokely MH,
    3. Michael Doster J
    . Thermal performance of batch boiling water targets for 18F production. Appl Radiat Isot. 2011;69:1349–1354.
    OpenUrlPubMed
  16. 16.↵
    1. Peeples JL,
    2. Stokely MH,
    3. Poorman MC,
    4. Bida GT,
    5. Wieland BW
    . Simulation, design, and testing of a high power collimator for the RDS-112 cyclotron. Appl Radiat Isot. 2015;97:87–92.
    OpenUrl
  17. 17.↵
    1. Williams MC,
    2. Mirsadraee S,
    3. Dweck MR,
    4. et al
    . Computed tomography myocardial perfusion vs 15O-water positron emission tomography and fractional flow reserve. Eur Radiol. 2017;27:1114–1124.
    OpenUrl
  18. 18.↵
    1. Carlos P,
    2. Beil H,
    3. Bergere R,
    4. Berman BL,
    5. Lepretre A,
    6. Veyssiere A
    . Photoneutron cross sections for oxygen from 24-133 MeV. Nucl Phys A. 1982;378:317–339.
    OpenUrl
  19. 19.↵
    1. Veyssiere A,
    2. Beil H,
    3. Bergere R,
    4. Carlos P,
    5. Lepretre A,
    6. De Miniac A
    . A study of the photoneutron contribution to the giant dipole resonance of s-d shell nuclei. Nucl Phys A. 1974;227:513–540.
    OpenUrl
  • Received for publication June 7, 2018.
  • Accepted for publication September 5, 2018.
View Abstract
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 60 (3)
Journal of Nuclear Medicine
Vol. 60, Issue 3
March 1, 2019
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Production of 15O for Medical Applications via the 16O(γ,n)15O Reaction
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Production of 15O for Medical Applications via the 16O(γ,n)15O Reaction
Stacy L. Queern, Ryan Cardman, Christopher S. Loveless, Matthew R. Shepherd, Suzanne E. Lapi
Journal of Nuclear Medicine Mar 2019, 60 (3) 424-428; DOI: 10.2967/jnumed.118.215681

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Production of 15O for Medical Applications via the 16O(γ,n)15O Reaction
Stacy L. Queern, Ryan Cardman, Christopher S. Loveless, Matthew R. Shepherd, Suzanne E. Lapi
Journal of Nuclear Medicine Mar 2019, 60 (3) 424-428; DOI: 10.2967/jnumed.118.215681
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Chemistry in the Radiologic Sciences
  • Google Scholar

More in this TOC Section

Radiochemistry

  • Cyclotron-Produced 132La as a PET Imaging Surrogate for Therapeutic 225Ac
  • Cyclotron Production and Separation of Scandium Radionuclides from Natural Titanium Metal and Titanium Dioxide Targets
  • Synthesis of the PET Tracer 124I-Trametinib for MAPK/ERK Kinase Distribution and Resistance Monitoring
Show more Radiochemistry

Basic

  • Cyclotron-Produced 132La as a PET Imaging Surrogate for Therapeutic 225Ac
  • Cyclotron Production and Separation of Scandium Radionuclides from Natural Titanium Metal and Titanium Dioxide Targets
  • Synthesis of the PET Tracer 124I-Trametinib for MAPK/ERK Kinase Distribution and Resistance Monitoring
Show more Basic

Similar Articles

Keywords

  • Molecular imaging
  • radiochemistry
  • oxygen-15
  • Positron Emission Tomography
  • eLINAC
  • photonuclear
SNMMI

© 2025 SNMMI

Powered by HighWire