Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleCLINICAL INVESTIGATIONS

PET Changes Management and Improves Prognostic Stratification in Patients with Recurrent Colorectal Cancer: Results of a Multicenter Prospective Study

Andrew M. Scott, Dishan H. Gunawardana, Ben Kelley, John G. Stuckey, Amanda J. Byrne, Jayne E. Ramshaw and Michael J. Fulham
Journal of Nuclear Medicine September 2008, 49 (9) 1451-1457; DOI: https://doi.org/10.2967/jnumed.108.051615
Andrew M. Scott
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dishan H. Gunawardana
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ben Kelley
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John G. Stuckey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amanda J. Byrne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jayne E. Ramshaw
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael J. Fulham
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

The aims of our study were to examine the impact of PET in changing management in patients with proven or suspected colorectal cancer recurrence and to assess the impact of management change on disease-free survival. Methods: Symptomatic patients with a residual structural lesion suggestive of recurrent tumor (group A) or patients with pulmonary or hepatic metastases considered to be potentially resectable (group B) underwent PET scans. Pre-PET management plans were documented by referring clinicians unaware of the PET results, and follow-up to 12 mo was performed to determine actual management and clinical outcomes. Results: A total of 191 patients (118 men and 73 women; mean age, 66 y) were studied. PET detected additional sites of disease in 48.4% of patients in group A and in 43.9% of patients in group B. A change in planned management was documented in 65.6% of group A and in 49.0% of group B patients. These management plans were implemented in 96% of patients. Follow-up data in group A showed progressive disease in 60.5% of patients with additional lesions detected by PET, compared with conventional imaging, and in 36.2% of patients with no additional lesions detected by PET (P = 0.04). In group B, progressive disease was identified in 65.9% of patients with additional lesions detected by PET and in 39.2% of patients with no additional lesions detected by PET (P = 0.01). PET also provided valuable prognostic information on patients stratified into curative- or palliative-intent groups. Conclusion: These data demonstrate the significant impact of PET on management and outcomes in patients with suspected recurrent colorectal cancer.

  • molecular imaging
  • oncology
  • PET/CT
  • PET
  • colorectal cancer
  • management change

Colorectal cancer is the second most common cancer, after skin cancer, in Australia (1). It was estimated to be the fourth most common cancer in the United States in 2006 (2). Surgery will cure approximately 50% of patients; however, in 30%−40% of patients with stage II or III colorectal cancer, recurrent disease or a second colorectal primary will develop (3). A large proportion of recurrences will be localized to a single organ, such as the liver, or an anatomic region, such as the pelvis (4,5). Some patients with localized recurrence will be cured with further surgery, and Goldberg et al. reported a 23% 5-y disease-free survival (5). Tepper et al., in another large series, showed that surgery for single-site recurrence resulted in a 27% 5-y disease-free survival (4). There is no clear consensus on the factors that predict the success of surgery for recurrent hepatic and pulmonary metastases (6–9). However, for patients with recurrence localized to the liver, there is general agreement that multiple hepatic metastases and the presence of extrahepatic lesions confer an adverse prognosis.

18F-FDG PET has been shown to be highly accurate in the detection of recurrent and metastatic colorectal cancer (10–15). A PET scan has comparable sensitivity to a CT scan for the detection of colorectal liver metastases (12–14) but has superior sensitivity in the detection of extrahepatic disease, compared with CT, and changes the estimation of disease extent in over one third of patients (11,13,16). Several reports also indicate that PET can influence the management of patients with metastatic colorectal cancer (11,17–20), but there are few prospective studies (11,17). Further, multicenter studies with large patient groups have not been performed, and the impact of PET on patient outcomes (progression-free survival) has not been previously reported.

Our aims in this prospective multicenter study were to evaluate PET in patients with suspected and proven recurrent colorectal cancer undergoing: (a) characterization of residual structural lesion after initial therapy, and (b) preoperative staging before resection of apparently isolated metastases. The PET findings were compared with the findings from conventional imaging, and the impact of PET on patient management was determined. We also evaluated the effect that these management changes had on progression-free survival.

MATERIALS AND METHODS

Patients

This prospective study was conducted at four Australian PET centers. Eligible patients had a previous diagnosis of colorectal cancer proven by histology and either a symptomatic residual structural lesion (i.e., on CT, ultrasound, or MRI) with appearances equivocal for recurrent tumor (group A patients) or pulmonary or hepatic metastases that were potentially resectable as determined by conventional imaging (group B patients). Patients had to be suitable for active treatment if localized disease was confirmed and at least 18 y old. Patients were excluded if they had received chemotherapy completed less than 1 wk before the PET examination, had abdominal surgery within 6 wk of the PET examination, had uncontrolled diabetes mellitus, or were pregnant at the time of the PET scan. The institutional ethics review boards at the participating hospitals approved the study, and informed consent was obtained from all patients.

Conventional Staging Investigations

All patients had contrast-enhanced CT scans of the chest and/or abdomen and pelvis performed within 6 wk of their PET scans. Other imaging modalities were used according to clinical indication. Investigators were required to record whether lesions seen on PET were adequately assessed by prior anatomic imaging methods.

PET Scan Procedure and Image Interpretation

Patients fasted for a minimum of 6 h before the PET study. At the discretion of the physician reporting the PET study, urinary catheters were inserted before the PET scan to optimize pelvic imaging. 18F-FDG (120–400 MBq) was administered intravenously. After a minimum uptake period of 45 min, PET emission data were acquired from the base of skull to the upper thighs. At institutions with PET/CT scanners, CT scans were performed for anatomic localization and attenuation correction of image data. PET transmission data were used for attenuation correction if the CT data were not available. PET scans were interpreted by experienced, credentialed PET specialists with full knowledge of conventional imaging results; all sites of lesions and their concordance or discordance with other data were recorded. Comparison of pre-PET results with findings of PET scans was performed. Validation of PET scan results for tumor detection, compared with conventional staging results, was performed by evaluating these results with any subsequent operative, pathologic, and imaging findings at 6 mo after the PET scan in all patients.

Documentation of Management Plans

The referring clinicians were required to document a management plan for the patient before they received the results of the PET scans but with access to results from all other clinical and conventional imaging. This management plan outlined the modalities planned, such as surgery, chemotherapy, radiotherapy, or a combination of these modalities. Information was also collected on the planned extent of these therapies. Following the release of the PET results, a second management plan was recorded, including any changes in intended management as a result of the PET scan. The actual management plan, based on follow-up, was also recorded.

Impact of PET on Patient Management

The impact of PET on patient management plans was assessed by comparing pre-PET management plans with post-PET management plans for individual patients, and by asking the referring clinician if the management had been changed on the basis of the PET results. Referring clinicians were also asked to assess the impact of PET on management as follows: None (PET result indicates that a management different from the one planned may be appropriate, but no change in management occurs as a result of PET information, allowing for management decisions that may be made for other clinical reasons); Low (PET result is consistent with planned management, and treatment modality or intent is unchanged); Medium (the treatment modality or intent remains unchanged, although the planned procedure, dose of therapy, or mode of delivery is altered because of PET result); and High (the treatment modality or intent is changed because of PET result).

Patient Follow-up and Prediction of Disease-Free Survival on Basis of PET

Patients underwent follow-up for 12 mo after the PET scan. The date of tumor progression as determined by the treating clinician was recorded. The detection of additional lesions by PET, when compared with conventional imaging, was analyzed for prediction of progression-free survival for individual patients. The impact of stratification of patients into curative- versus palliative-intent groups on the basis of PET results, and into surgical-intent groups, on progression-free survival was also analyzed.

Statistics

A sample size of at least 100 patients in total was initially planned based on the assumption that if 20 patients had data insufficient for analysis, and if 20% of the remaining patients were to have a change in management plan, the 95% confidence intervals (CIs) would be 11%−29%. Groups A and B were also analyzed separately, and power calculation remained valid for each of these groups, as more than 80 patients were evaluable in each of the groups. Bivariate tables were analyzed using the χ2 test. Survival analyses were performed using the Kaplan–Meier method, and the groups were compared using the log-rank test.

RESULTS

Patient Demographics

Between November 23rd, 2003, and August 12th, 2004, 204 patients were enrolled in the study. Thirteen patients were ineligible for data analysis, as the treatment plans for these patients were not initiated before patient death or it was not possible to confirm that the treatment plan had been initiated, leaving 191 eligible patients (Royal Prince Alfred Hospital in Sydney, n = 122; Austin Hospital in Melbourne, n = 27; MIA Moorabbin in Melbourne, n = 26; and Wesley Hospital in Brisbane, n = 16). Group A consisted of 93 patients (patients with lesions equivocal for recurrent tumor). The median age was 66 y (range, 26–85), and 58% were men. For group A, the suspected lesions seen on pre-PET evaluation are shown in Table 1. Group B consisted of 98 patients (patients with potentially resectable liver or lung metastases). The median age was 66 y (range, 45–82), and 65% were men.

View this table:
  • View inline
  • View popup
TABLE 1

Sites of Lesions Identified by Pre-PET Evaluation and by PET for Group A Patients

Lesions Detected by PET, Compared with Conventional Imaging

In group A, 90 (96.8%) patients underwent a PET/CT scan; PET alone was used in 3 (3.2%). In group B, 83 (84.7%) patients underwent a PET/CT scan; PET alone was used in 15 (15.3%).

In group A, additional sites of disease were identified in 45 of 93 (48.4%) patients. The sites of lesions in group A are shown in Table 1. In group B, additional sites of disease were identified in 43 of 98 (43.9%) patients (1 patient had no lesions identified before PET or on PET). The sites of lesions in group B are shown in Supplemental Table 1 (supplemental materials are available online only at http://jnm.snmjournals.org).

Post-PET Change in Management Plan

In group A, 61 patients (65.6%) had management plans altered on the basis of the PET result (95% CI, 56.0%−75.3%). In group B, 48 patients (49.0%) had a change in management plan on the basis of the PET scan (95% CI, 39.1%−58.9%). The pre-PET and post-PET management plans and changes for groups A and B are shown in Tables 2 and 3.

View this table:
  • View inline
  • View popup
TABLE 2

Pre-PET and Post-PET Management Plans for Group A Patients

View this table:
  • View inline
  • View popup
TABLE 3

Pre-PET and Post-PET Management Plans for Group B Patients

In group A patients, referring clinicians rated the impact of PET on patient management as high in 60 (64.5%), medium in 5 (5.4%), low in 24 (25.8%), and none in 4 (4.3%) patients. These results were significant by χ2 analysis (χ2 = 88.38, P < 0.001). For group B patients, the impact of PET on patient management was rated as high in 41 (41.8%), medium in 5 (5.1%), low in 44 (44.9%), and none in 8 (8.2%) patients. These results were significant by χ2 analysis (χ2 = 53.27, P < 0.001).

Referring clinicians were also asked to record if the management plan intent was curative or palliative pre-PET and if there was a change on the basis of the PET results. In group A, the number of curative-intent patients remained similar, with 49 pre-PET and 50 post-PET; however, 29.0% of patients had treatment intent altered by PET (Table 4). For group B, the number of curative-intent patients reduced from 88 pre-PET to 69 post-PET, and 23.5% had treatment intent altered by PET results (Table 4). The changes in intent were statistically significant for group A (χ2 = 59.29, P < 0.001) and group B (χ2 = 87.82, P < 0.001).

View this table:
  • View inline
  • View popup
TABLE 4

Comparison of Management Intent Before PET and After PET

Actual Treatment

At the 6-mo follow-up, actual treatment was compared with the treatment planned post-PET. A medical oncologist with experience in the treatment of colorectal cancer reviewed the data and determined if the actual treatment was appropriate on the basis of the PET results.

For the 92 patients in group A for whom information on actual treatment was available, 57 patients received treatment as planned post-PET and 35 patients received treatment that differed from that planned post-PET. Review of the actual treatment implemented in these 35 patients showed that in 33 of the 35 cases, the actual treatment implemented was consistent overall with the PET results. In 2 patients, the treatment was not consistent; PET was false-positive in 1 patient and false-negative in another. In this second patient, both PET and CT missed omental disease. Detailed data on these 35 cases are provided in Supplemental Table 2.

For group B, in 97 patients for whom information on actual treatment was available, there were 68 patients whose actual treatment was as planned post-PET and 29 patients whose actual treatment differed from that planned post-PET. Review of these 29 patients showed that in 24, the actual treatment implemented was consistent overall with the PET results. PET was false-negative for lesions in 3 patients; in 2 of these, CT was also false-negative and in the third patient PET missed an adrenal lesion confirmed on subsequent CT. In 2 patients, the reasons for the differences remain unknown. Detailed data on these 29 cases are provided in Supplemental Table 3.

Thus, overall, the management plan actually implemented was consistent with the stated post-PET management plan in 96% of patients.

Progression-Free Survival

Patients with additional lesions detected on PET compared with conventional imaging had inferior progression-free survival (Fig. 1). Follow-up data showed that in group A, progressive disease was identified in 60.5% of patients with additional lesions detected on PET compared with conventional imaging, and 36.2% patients with no additional lesions detected by PET (P = 0.04). In group B, progressive disease was identified in 65.9% of patients with additional lesions detected on PET and in 39.2% patients with no additional lesions detected on PET (P = 0.01). Patients in group B stratified by PET as having additional lesions localized outside the liver or lungs, compared with those with liver- or lung-only disease, also had inferior progression-free survival (Fig. 2).

FIGURE 1. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1. 

Kaplan–Meier analysis of progression-free survival for patients with additional lesions detected on PET vs. those with no additional lesions found on PET. Significant differences were found for group A (P = 0.04) (A) and group B patients (P = 0.01) (B).

FIGURE 2. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2. 

Kaplan–Meier analysis of progression-free survival for patients in group B with disease localized to either liver or lung on PET vs. those with disease in 2 or more organs (disseminated) (P = 0.0001) (A), those with disease localized to liver vs. those with liver and extrahepatic disease (P < 0.0001) (B), and those with disease localized to lungs vs. those with lung and extrapulmonary disease (P = 0.04) (C).

Patients classified as requiring curative or palliative treatment pre- and post-PET were compared using Kaplan–Meier survival analyses (Fig. 3). Patients in groups A and B were better stratified into curative and palliative groups after PET than before PET on the basis of progression-free survival. In addition, group B patients planned for surgery after PET had a superior progression-free survival than those planned before PET (after PET, P = 0.03) and similar survival to those patients who actually proceeded to surgery (data not shown). A total of 4 patients (2 in group A and 2 in group B) were excluded from the Kaplan–Meier analyses because of inadequate follow-up data.

FIGURE 3. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3. 

Kaplan–Meier analysis of progression-free survival for patients classified as curative or palliative for group A patients pre-PET (P = 0.32) (A), group A patients post-PET (P = 0.01) (B), group B patients pre-PET (P = 0.92) (C), and group B patients post-PET (P < 0.001) (D).

DISCUSSION

Previous studies have shown the impact of PET on the management of cancer in general and on colorectal cancer in particular. Fernandez et al. reported that the 5-y survival of patients with potentially resectable liver metastases from colorectal cancer was 58% in a population screened with PET, as compared with 30% in previous series (21). Recently published data from the National Oncologic PET Registry in patients with a variety of cancers (particularly prostate, pancreas, and ovarian cancers) showed that intended management was changed in 36.5% of patients after PET (22). In a single-institution prospective study of colorectal cancer, management was changed as a result of PET in 56% of patients (17). A survey of physicians who referred patients with colorectal cancer for PET found that the PET findings contributed to management change in 62% of patients (23). This compares with the 65.6% of patients in group A and 49.0% in group B who had management change in our study. Our study represents the largest prospective study of PET conducted to date in patients with recurrent colorectal cancer.

PET detected additional sites of disease in 48.4% of group A patients and 43.9% of group B patients; a similar percentage of patients had lesions seen in pre-PET evaluation but not detected by PET. The majority of lesions detected by PET were categorized as consistent with malignancy. The superior ability of PET to accurately identify malignant lesions was confirmed by follow-up analysis. These results are consistent with data previously reported (18–20) and may underestimate the specificity of PET, as CT was used as the baseline for comparison in our study.

For patients with a residual structural lesion suggestive of recurrent tumor (group A), 29.0% of patients also had a change in intent of treatment (curative to palliative or palliative to curative) on the basis of PET results. The methodology used to obtain information on management plans was carefully designed to minimize bias for PET in the analysis of intent to treat and post-PET decision making. Similar results were obtained for patients with pulmonary or hepatic metastases that were potentially resectable as determined by conventional imaging (group B): 23.5% of patients had a change in intent of treatment as a result of their PET scan. The slightly smaller number of patients who had change in intent post-PET in group B, compared with group A, may be because of the higher number of curative-intent patients in group B (89.8% vs. 52.7%) pre-PET and the higher number of patients in this group for whom surgery was initially planned.

Clinical outcome at 12 mo was assessed by comparing the progression-free survival of patients grouped by various criteria pre-PET and post-PET. To our knowledge, there has not been a similar prospective assessment for a patient cohort of this size reported previously. These data show the value of PET in the stratification of patients into curative or palliative and surgical or nonsurgical groups. Patients who had additional lesions found on PET, compared with conventional imaging, had a poorer prognosis. Patients in group B with disease localized to the liver or lungs on PET had a better prognosis than did those with more disseminated disease. These data clearly show the powerful prognostic ability of PET to accurately stratify patients who are thought to have localized disease on conventional imaging. It is also possible, although unlikely, that some of the prognostic impact was because of changes in treatment based on the PET result.

There are some limitations to our study. Treating physicians were asked to indicate their planned management without PET, which may not always have been the actual management that occurred in the absence of PET. Patients were generally referred from outside institutions to the PET centers; therefore, prognostic factors such as the time between initial diagnosis and tumor recurrence could not always be recorded, and multivariate analyses including the PET findings were not possible. For similar reasons, it was also not possible to completely standardize pre-PET conventional imaging. However, these features reflect real-world clinical practice and do not detract from the clinical importance of the results that we report.

CONCLUSION

These data represent the largest prospective study yet reported that examines the impact of PET on patient management in recurrent colorectal cancer and demonstrates the impact of PET on patient management and outcomes.

Acknowledgments

We acknowledge the Australian Government Department of Health and Ageing for funding and the Australian and New Zealand Association of Physicians in Nuclear Medicine for managing the PET Data Collection Project. We also thank Melinda Gibson, Debbie Lennon, and Anne-Maree Kerley for their contribution to data collection; Dr. Victor Kalff for his insightful comments; and the staff of the PET centers involved in the study.

Footnotes

  • COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Australian Institute of Health and Welfare (AIHW) and Australasian Association of Cancer Registries (AACR). Cancer in Australia 2001. Canberra, Australia: AIHW; 2004. Cancer Series no. 28.
  2. 2.↵
    American Cancer Society. Cancer Facts and Figures 2006. Atlanta, GA: American Cancer Society; 2006.
  3. 3.↵
    Goldberg RM. Intensive surveillance after stage II or III colorectal cancer: is it worth it? J Clin Oncol. 2006;24:330–331.
    OpenUrlFREE Full Text
  4. 4.↵
    Tepper JE, O'Connell M, Hollis D, et al. Analysis of surgical salvage after failure of primary therapy in rectal cancer: results from Intergroup Study 0114. J Clin Oncol. 2003;21:3623–3628.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    Goldberg RM, Fleming TR, Tangen CM, et al. Surgery for recurrent colon cancer: strategies for identifying resectable recurrence and success rates after resection. Eastern Cooperative Oncology Group, the North Central Cancer Treatment Group, and the Southwest Oncology Group. Ann Intern Med. 1998;129:27–35.
    OpenUrlPubMed
  6. 6.↵
    Fong Y, Fortner J, Sun RL, et al. Clinical score for predicting recurrence after hepatic resection for metastatic colorectal cancer: analysis of 1001 consecutive cases. Ann Surg. 1999;230:309–318.
    OpenUrlCrossRefPubMed
  7. 7.
    Nordlinger B, Guiguet M, Vaillant JC, et al. Surgical resection of colorectal carcinoma metastases to the liver: a prognostic scoring system to improve case selection, based on 1568 patients. Association Francaise de Chirurgie. Cancer. 1996;77:1254–1262.
    OpenUrlCrossRefPubMed
  8. 8.
    Poston GJ, Adam R, Alberts S, et al. OncoSurge: a strategy for improving resectability with curative intent in metastatic colorectal cancer. J Clin Oncol. 2005;23:7125–7134.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    Iizasa T, Suzuki M, Yoshida S, et al. Prediction of prognosis and surgical indications for pulmonary metastasectomy from colorectal cancer. Ann Thorac Surg. 2006;82:254–260.
    OpenUrlCrossRefPubMed
  10. 10.↵
    Scott AM. Current status of positron emission tomography in oncology. Int Med J. 2001;31:27–36.
    OpenUrlCrossRef
  11. 11.↵
    Huebner RH, Park KC, Shepherd JE, et al. A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer. J Nucl Med. 2000;41:1177–1189.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    Lai DT, Fulham M, Stephen MS, et al. The role of whole-body positron emission tomography with [18F]fluorodeoxyglucose in identifying operable colorectal cancer metastases to the liver. Arch Surg. 1996;131:703–707.
    OpenUrlCrossRefPubMed
  13. 13.↵
    Ogunbiyi OA, Flanagan FL, Dehdashti F, et al. Detection of recurrent and metastatic colorectal cancer: comparison of positron emission tomography and computed tomography. Ann Surg Oncol. 1997;4:613–620.
    OpenUrlCrossRefPubMed
  14. 14.↵
    Flamen P, Stroobants S, Van Cutsem E, et al. Additional value of whole-body positron emission tomography with fluorine-18-2-fluoro-2-deoxy-d-glucose in recurrent colorectal cancer. J Clin Oncol. 1999;17:894–901.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    Akhurst T, Larson SM. Positron emission tomography imaging of colorectal cancer. Semin Oncol. 1999;26:577–583.
    OpenUrlPubMed
  16. 16.↵
    Schoder H, Larson SM. PET/CT in oncology: integration into clinical management of lymphoma, melanoma and gastrointestinal malignancies. J Nucl Med. 2004;45(suppl):72S–81S.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    Kalff V, Hicks RJ, Ware RE, et al. The clinical impact of 18F-FDG PET in patients with suspected or confirmed recurrence of colorectal cancer: a prospective study. J Nucl Med. 2002;43:492–499.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    Bipat S, Van Leeuwen MS, Comans EF, et al. Colorectal liver metastases: CT, MR imaging, and PET for diagnosis—meta-analysis. Radiology. 2005;237:123–131.
    OpenUrlCrossRefPubMed
  19. 19.
    Wiering B, Krabbe PF, Jager GJ, et al. The impact of fluor-18-deoxyglucose-positron emission tomography in the management of colorectal liver metastases. Cancer. 2005;104:2658–2670.
    OpenUrlCrossRefPubMed
  20. 20.↵
    Ruers TJ, Langenhoff BS, Neeleman N, et al. Value of positron emission tomography with [F-18]fluorodeoxyglucose in patients with colorectal liver metastases: a prospective study. J Clin Oncol. 2002;20:388–395.
    OpenUrlAbstract/FREE Full Text
  21. 21.↵
    Fernandez FG, Drebin JA, Linehan DC, et al. Five-year survival after resection of hepatic metastases from colorectal cancer in patients screened by positron emission tomography with F-18 fluorodeoxyglucose (FDG-PET). Ann Surg. 2004;240:438–447.
    OpenUrlCrossRefPubMed
  22. 22.↵
    Hillner BE, Siegel BA, Liu D, et al. Impact of positron emission tomography/computed tomography and positron emission tomography (PET) alone on expected management of patients with cancer: initial results from the national oncologic PET registry. J Clin Oncol. 2008;26:2155–2161.
    OpenUrlAbstract/FREE Full Text
  23. 23.↵
    Meta J, Seltzer M, Schiepers C, et al. Impact of 18F-FDG PET on managing patients with colorectal cancer: the referring physician's perspective. J Nucl Med. 2001;42:586–590.
    OpenUrlAbstract/FREE Full Text
  • Received for publication February 10, 2008.
  • Accepted for publication May 28, 2008.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 49 (9)
Journal of Nuclear Medicine
Vol. 49, Issue 9
September 2008
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
PET Changes Management and Improves Prognostic Stratification in Patients with Recurrent Colorectal Cancer: Results of a Multicenter Prospective Study
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
PET Changes Management and Improves Prognostic Stratification in Patients with Recurrent Colorectal Cancer: Results of a Multicenter Prospective Study
Andrew M. Scott, Dishan H. Gunawardana, Ben Kelley, John G. Stuckey, Amanda J. Byrne, Jayne E. Ramshaw, Michael J. Fulham
Journal of Nuclear Medicine Sep 2008, 49 (9) 1451-1457; DOI: 10.2967/jnumed.108.051615

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
PET Changes Management and Improves Prognostic Stratification in Patients with Recurrent Colorectal Cancer: Results of a Multicenter Prospective Study
Andrew M. Scott, Dishan H. Gunawardana, Ben Kelley, John G. Stuckey, Amanda J. Byrne, Jayne E. Ramshaw, Michael J. Fulham
Journal of Nuclear Medicine Sep 2008, 49 (9) 1451-1457; DOI: 10.2967/jnumed.108.051615
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • The Australasian Radiopharmaceutical Trials Network: Clinical Trials, Evidence, and Opportunity
  • Intended Versus Inferred Treatment After 18F-Fluoride PET Performed for Evaluation of Osseous Metastatic Disease in the National Oncologic PET Registry
  • Variation in Positron Emission Tomography Use After Colon Cancer Resection
  • Primary Jejunal Adenocarcinoma Incidentally Diagnosed on Positron Emission Tomography/Computed Tomography in a Patient With Metastatic Colorectal Cancer: Suspicion of Lynch Syndrome and Effect on Therapeutic Management
  • Prognostic Ability of 18F-FDG PET/CT in the Assessment of Colorectal Liver Metastases
  • Doing More Harm than Good? Do Systematic Reviews of PET by Health Technology Assessment Agencies Provide an Appraisal of the Evidence That Is Closer to the Truth than the Primary Data Supporting Its Use?
  • Are Health Economics Making Us Sick?
  • NCCN Task Force: Clinical Utility of PET in a Variety of Tumor Types
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire