Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigation

Performance Characteristics of a New-Generation Digital Bismuth Germanium Oxide PET/CT System, Omni Legend 32, According to NEMA NU 2-2018 Standards

Shin Yamagishi, Kenta Miwa, Shun Kamitaki, Kouichi Anraku, Shun Sato, Tensho Yamao, Hitoshi Kubo, Noriaki Miyaji and Kazuhiro Oguchi
Journal of Nuclear Medicine December 2023, 64 (12) 1990-1997; DOI: https://doi.org/10.2967/jnumed.123.266140
Shin Yamagishi
1Center of Radiology and Diagnostic Imaging, Aizawa Hospital, Nagano, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kenta Miwa
2Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shun Kamitaki
1Center of Radiology and Diagnostic Imaging, Aizawa Hospital, Nagano, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kouichi Anraku
1Center of Radiology and Diagnostic Imaging, Aizawa Hospital, Nagano, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shun Sato
1Center of Radiology and Diagnostic Imaging, Aizawa Hospital, Nagano, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tensho Yamao
2Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hitoshi Kubo
2Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Noriaki Miyaji
2Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kazuhiro Oguchi
1Center of Radiology and Diagnostic Imaging, Aizawa Hospital, Nagano, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • Additional Files
  • Figure
    • Download figure
    • Open in new tab
    • Download powerpoint
  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    Sensitivity values at 0- and 10-cm offset. (A) Sensitivity as function of numbers of attenuating aluminum sleeves. (B) Axial sensitivity profile.

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    Count rates for prompt, random, true, and scatter events and noise-equivalent count (NEC) as function of activity concentration.

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    Scatter fraction for Omni Legend as function of activity concentration.

  • FIGURE 4.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 4.

    Accuracy of extrapolated true rate (A) and maximum, mean, and minimum error (B) as function of activity concentration for Omni Legend.

  • FIGURE 5.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 5.

    Images of deluxe (A) and mini deluxe (B) Derenzo phantoms using Q.Clear (β-value, 50): original distribution of CT images (left) and actual acquired PET images (right).

  • FIGURE 6.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 6.

    Pancreatic cancer patient images acquired using Omni Legend at 120 s/bed position (8 min total). (A) Maximum-intensity-projection PET images. Numbers indicate lesion SUVmax. (B) Transaxial PET images. HPDL = high-precision DL; LPDL = low precision DL; MPDL = medium-precision DL; noise = noise level of liver (%); non-PDL = nonprecision DL; PSF = point-spread function.

  • FIGURE 7.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 7.

    Lung cancer patient images acquired using Omni Legend at 120 s/bed position (8 min total). (A) Maximum-intensity-projection PET images. Numbers indicate lesion SUVmax. (B) Coronal PET images. HPDL = high-precision DL; LPDL = low precision DL; MPDL = medium-precision DL; noise = noise level of liver (%); non-PDL = nonprecision DL; PSF = point-spread function.

Tables

  • Figures
  • Additional Files
    • View popup
    TABLE 1.

    All NEMA NU 2-2018 Results for Omni Legend

    ParameterValue
    Spatial resolution (FWHM, mm)
     FBP
      1 cm4.34, radial; 4.22, tangential; 4.42, axial
      10 cm5.90, radial; 4.55, tangential; 5.57, axial
      20 cm7.83, radial; 5.03, tangential; 5.59, axial
     OSEM
      1 cm3.89, radial; 3.73, tangential; 3.61, axial
      10 cm5.10, radial; 3.90, tangential; 3.76, axial
      20 cm7.59, radial; 4.26, tangential; 3.58, axial
    Sensitivity (cps/kBq)
     At center47.30
     At 10 cm47.05
    Count rate statistics
     Peak NECR (kcps)501.7
     Peak NECR activity (kBq/mL)15.70
     Scatter fraction at peak NECR (%)35.42
     Maximum error at peak NECR (%)1.70
     Maximum mean error at peak NECR (%)0.98
    Image quality (%)
     OSEM
      10 mm53.5 (3.1), CR; 8.0 (0.8), BV
      13 mm65.1 (2.2), CR; 6.5 (0.9), BV
      17 mm73.0 (2.8), CR; 5.0 (0.6), BV
      22 mm78.5 (2.4), CR; 3.9 (0.3), BV
      28 mm85.3 (2.7), CR; 3.2 (0.3), BV
      37 mm88.9 (2.3), CR; 2.6 (0.1), BV
      Average lung error12.0 (0.3)
     Q.Clear (β-value, 50)
      10 mm61.3 (3.3), CR; 5.4(0.8), BV
      13 mm75.2 (1.6), CR; 4.2(0.4), BV
      17 mm80.1 (1.3), CR; 3.3(0.3), BV
      22 mm84.5 (1.2), CR; 2.7(0.3), BV
      28 mm90.1 (1.2), CR; 2.2(0.3), BV
      37 mm93.0 (1.2), CR; 1.7(0.1), BV
      Average lung error5.1 (0.3)
     Q.Clear (β-value, 300)
      10 mm36.4 (2.1), CR; 2.9(0.5), BV
      13 mm60.5 (0.5), CR; 2.5(0.4), BV
      17 mm71.6 (0.6), CR; 2.1(0.3), BV
      22 mm79.3 (0.8), CR; 1.8(0.3), BV
      28 mm85.1 (0.6), CR; 1.5(0.2), BV
      37 mm89.7 (0.3), CR; 1.3(0.1), BV
      Average lung error6.3 (0.2)
    Coregistration accuracy (mm)
     Error at (0,1)0.85, 5 cm; 2.47, 100 cm
     Error at (0,20)1.54, 5 cm; 3.30, 100 cm
     Error at (20,0)1.29, 5 cm; 2.73, 100 cm
    • FWHM = full width at half maximum; FBP = filtered backprojection; CR = contrast recovery; BV = background variability.

    • Data in parentheses are SDs.

Additional Files

  • Figures
  • Tables
  • Supplemental Data

    Files in this Data Supplement:

    • Supplemental Data
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 64 (12)
Journal of Nuclear Medicine
Vol. 64, Issue 12
December 1, 2023
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Performance Characteristics of a New-Generation Digital Bismuth Germanium Oxide PET/CT System, Omni Legend 32, According to NEMA NU 2-2018 Standards
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Performance Characteristics of a New-Generation Digital Bismuth Germanium Oxide PET/CT System, Omni Legend 32, According to NEMA NU 2-2018 Standards
Shin Yamagishi, Kenta Miwa, Shun Kamitaki, Kouichi Anraku, Shun Sato, Tensho Yamao, Hitoshi Kubo, Noriaki Miyaji, Kazuhiro Oguchi
Journal of Nuclear Medicine Dec 2023, 64 (12) 1990-1997; DOI: 10.2967/jnumed.123.266140

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Performance Characteristics of a New-Generation Digital Bismuth Germanium Oxide PET/CT System, Omni Legend 32, According to NEMA NU 2-2018 Standards
Shin Yamagishi, Kenta Miwa, Shun Kamitaki, Kouichi Anraku, Shun Sato, Tensho Yamao, Hitoshi Kubo, Noriaki Miyaji, Kazuhiro Oguchi
Journal of Nuclear Medicine Dec 2023, 64 (12) 1990-1997; DOI: 10.2967/jnumed.123.266140
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Performance Characteristics of a New Generation 148-cm Axial Field-of-View uMI Panorama GS PET/CT System with Extended NEMA NU 2-2018 and EARL Standards
  • Quantitative PET imaging and modeling of molecular blood-brain barrier permeability
  • Google Scholar

More in this TOC Section

  • [11C]ZTP-1: An Effective Short-Lived Radioligand for PET of Rat and Monkey Brain Phosphodiesterase Type 4 Subtype B
  • Reduced Renal Uptake of Various Radiopharmaceuticals with Sodium Paraaminohippurate Coadministration in a Rat Model
  • In Vivo Visualization and Quantification of Brain Heat Shock Protein 90 with [11C]HSP990 in Healthy Aging and Neurodegeneration
Show more Basic Science Investigation

Similar Articles

Keywords

  • PET/CT
  • NEMA
  • performance evaluation
  • Omni Legend
  • SiPM
SNMMI