Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPoster - PhysicianPharm

Inter-pass motion correction for whole-body dynamic parametric PET imaging

Xueqi Guo, Jing Wu, Ming-Kai Chen, John Onofrey, Yulei Pang, David Pigg, Michael Casey, Nicha Dvornek and Chi Liu
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1421;
Xueqi Guo
1Department of Biomedical Engineering Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jing Wu
3Department of Radiology and Biomedical Imaging Yale University New Haven CT United States
2Department of Physics Beijing Normal University Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ming-Kai Chen
3Department of Radiology and Biomedical Imaging Yale University New Haven CT United States
4Yale New Haven Hospital New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John Onofrey
3Department of Radiology and Biomedical Imaging Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yulei Pang
1Department of Biomedical Engineering Yale University New Haven CT United States
5Department of Mathematics Southern Connecticut State University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Pigg
6Siemens Medical Solutions Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Casey
6Siemens Medical Solutions Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nicha Dvornek
3Department of Radiology and Biomedical Imaging Yale University New Haven CT United States
1Department of Biomedical Engineering Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chi Liu
3Department of Radiology and Biomedical Imaging Yale University New Haven CT United States
1Department of Biomedical Engineering Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

1421

Objectives: Whole-body dynamic PET imaging can be achieved through multi-pass continuous bed motion (CBM) acquisition protocol on Siemens scanners. However, body motion during the scanning could cause inter-pass mismatch, subsequently affecting parametric image generation. In this work, we implemented a non-rigid registration method to correct inter-pass motion for dynamic PET.

Methods: 27 subjects (5 healthy and 22 cancer patients) were included in this study. Each underwent a 90-min whole-body dynamic FDG CBM PET scan on a Biograph mCT (Siemens Healthineers, Knoxville, TN). A single-bed scan over the heart was acquired first for 6 min and then 19 CBM passes (frames) were acquired (4 × 2 min and 15 × 5 min). The inter-pass motion correction was achieved through non-linear image registration with B-spline free-form deformations via BioImage Suite. Each 5-min frame was registered to frame 12 as the reference image. A multi-resolution optimization was performed first at a coarse level and then refined to higher resolution, using normalized mutual information as the similarity metric. All dynamic frames were converted to standardized uptake values (SUV) unit, and an intensity cutoff at an SUV threshold equal to 2.5 was applied when computing the displacement fields to minimize the impact from the high-intensity bladder voxels. The parametric images were then generated by fitting the Patlak model (t* = 20 min) using the individual subject’s arterial input function. The overlaid Patlak plot slope Ki and intercept Vb were visualized to identify any mismatch. 57 regions of interest (ROI) (8 benign and 49 malignant) were drawn on hypermetabolic hotspots in 22 cancer subjects. The normalized fitting errors were compared using the paired two-tailed t-test for the whole body, head, and ROIs. In Ki images, we conducted ROI analysis and estimated the classification capability between benign and malignant ROIs using a receiver operating characteristic (ROC) curve and the area under the curve (AUC).

Results: The alignment between Ki/Vb images improved after inter-pass motion correction. Voxel-wise normalized fitting error images showed global error reduction with motion correction. Quantitatively, the normalized fitting errors significantly decreased in the whole body (p = 0.0496), head (p = 0.0090), and ROIs (p = 0.0022). In both benign and malignant ROI groups, the mean values for each ROI decreased after correction while the maximum values and standard deviation increased. The AUC of mean Ki after motion correction increased from 0.801 to 0.806.

Conclusions: The inter-pass motion correction using non-rigid registration has a great potential to enhance the alignment between Ki and Vb images, and improve the parameter estimation accuracy. Acknowledgments: This work was supported by NIH grant R01 CA224140.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 62, Issue supplement 1
May 1, 2021
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Inter-pass motion correction for whole-body dynamic parametric PET imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Inter-pass motion correction for whole-body dynamic parametric PET imaging
Xueqi Guo, Jing Wu, Ming-Kai Chen, John Onofrey, Yulei Pang, David Pigg, Michael Casey, Nicha Dvornek, Chi Liu
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1421;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Inter-pass motion correction for whole-body dynamic parametric PET imaging
Xueqi Guo, Jing Wu, Ming-Kai Chen, John Onofrey, Yulei Pang, David Pigg, Michael Casey, Nicha Dvornek, Chi Liu
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1421;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Poster - PhysicianPharm

  • Preliminary result of Texture Analysis on prediction of overall outcome of neuroendocrine tumors based on pre-therapy heterogeneity of somatostatin receptors on 68Ga Dotatate PET/CT scans.
  • The Incremental Value of 18F FDG Labelled Leukocytes PET/CT Over 18F FDG PET/CT Scan in the Detection of Occult Infection
  • Respiratory motion correction reduces differences between immediate and delayed SPECT myocardial perfusion images
Show more Poster - PhysicianPharm

PIDS - Data Analysis and Management

  • An empirical update of left ventricular 3D segmentation algorithm in myocardial perfusion SPECT imaging
  • Using radiomics feature to distinguish malignant from benign solitary pulmonary nodules on dual time point PET/CT images
Show more PIDS - Data Analysis and Management

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire