Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleHot Topics

Phantom Preparation Using a Dilution Technique

Martin A. Lodge
Journal of Nuclear Medicine March 2021, 62 (3) 303; DOI: https://doi.org/10.2967/jnumed.120.257097
Martin A. Lodge
Johns Hopkins University, Baltimore, Maryland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Physical phantoms with compartments containing different concentrations of radioactivity are widely used in PET methodology research, system performance assessment, and routine quality assurance. Accreditation bodies such as the American College of Radiology require the use of a phantom involving an aqueous solution of 18F in various inserts and a lower radioactivity concentration in a background region. These phantoms have to be prepared manually, usually by technologists or physicists with specific experience in this kind of experimental work. Even in the hands of experienced practitioners, phantom preparation is prone to experimental error and subject to variability because it involves many manual steps. When unexpected phantom results occur, they are commonly attributed to fluctuations in scanner performance but in many cases may simply be due to errors in phantom filling. Reliable phantom preparation is clearly important, and in this article, readers are reminded of a dilution technique that can greatly simplify the process.

Current guidance on phantom filling typically involves preparation of 2 carefully calibrated radioactive samples (1). One is transferred to the phantom background compartment, and the other is used to prepare a higher-concentration solution that is subsequently used to fill the phantom inserts. With knowledge of the volumes of the relevant compartments, target activities can be selected that provide the required insert-to-background concentration ratio. Although conceptually straightforward, in practice this process is complicated by the difficulty of preparing 2 rapidly decaying samples with precise activities at the same time. To allow for this difficulty, each radioactivity measurement is permitted to deviate from the target value within a certain range, but this flexibility can introduce large errors in the resulting insert-to-background ratio and unwanted variability between repeated experiments. Skilled operators are adept at managing these complexities, but more accurate and repeatable phantom preparation can be achieved with a simpler filling protocol.

An alternative to the procedure described above involves an initial step in which the phantom background compartment is partially filled with water. To achieve an N-to-1 insert-to-background radioactivity concentration ratio, the phantom would initially be filled with 1/N of the total background volume, for example, 4/10 full in the case of a 2.5-to-1 ratio. A single calibrated radioactive sample is then added to the phantom background, and after thorough mixing, a small volume of this radioactive solution is withdrawn and used to fill the phantom inserts. Finally, the phantom background compartment is completely filled with additional nonradioactive water, diluting the background radioactivity concentration and thereby achieving the desired insert-to-background ratio. Allowance can be made for the small volume of liquid used to fill the inserts by adding an equivalent volume to the initial fill. Also, the small amount of radioactivity withdrawn to fill the inserts can be estimated from the relevant volumes and subtracted from the dose calibrator measurement to determine the final activity in the background region.

This dilution technique is readily applicable to many different phantoms commonly used in PET, including the National Electrical Manufacturers Association NU2 image-quality phantom and the American College of Radiology PET phantom (Data Spectrum). As an example, the latter phantom was prepared with a 2.5-to-1 insert-to-background ratio on 5 separate occasions. One-time volume measurements of the background compartment (5,680 mL) and 4 fillable inserts (33 mL total) were determined by weighing with an accurate balance. Phantom filling was tested by withdrawing 300-μL aliquots from the insert and background compartments and measuring with a NaI(Tl) γ-counter. The mean (±SD of repeated measurements) insert-to-background radioactivity concentration ratio derived from the γ-counter was 2.48 ± 0.01. Relative to the target ratio of 2.5, this corresponds to 99.3% ± 0.5%, suggesting highly accurate and highly repeatable phantom preparation. The method is easy to implement, can be performed rapidly, and is highly robust because the insert-to-background ratio is not dependent on any dose calibrator measurements. Although dilution methods of this sort have no doubt been in use for some time, more widespread awareness may be helpful and the technique could be considered further as phantom guidelines are updated.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Dec. 11, 2020.

  • © 2021 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCE

  1. 1.↵
    Phantom testing: PET. ACR accreditation website. https://accreditationsupport.acr.org/support/solutions/articles/11000062800-phantom-testing-pet. Published December 12, 2019. Accessed December 10, 2020.
  • Received for publication September 18, 2020.
  • Accepted for publication September 22, 2020.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 62 (3)
Journal of Nuclear Medicine
Vol. 62, Issue 3
March 1, 2021
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Phantom Preparation Using a Dilution Technique
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Phantom Preparation Using a Dilution Technique
Martin A. Lodge
Journal of Nuclear Medicine Mar 2021, 62 (3) 303; DOI: 10.2967/jnumed.120.257097

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Phantom Preparation Using a Dilution Technique
Martin A. Lodge
Journal of Nuclear Medicine Mar 2021, 62 (3) 303; DOI: 10.2967/jnumed.120.257097
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • DISCLOSURE
    • Footnotes
    • REFERENCE
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • RECIP 1.0: A Roadmap for Clinical Implementation
  • Diagnostic Radiopharmaceutical Trial Design: Is It Time to Change Nomenclature?
  • From Stabilization to Depletion: Molecular Imaging to Measure Therapeutic Response in ATTR-CA
Show more Hot Topics

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire