Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring

Wenzhuo Lu, Tianyu Ma, Tao Yang, Shouping Xu and Yaqiang Liu
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 574;
Wenzhuo Lu
2Key Laboratory of Particle & Radiation Imaging Ministry of Education (Tsinghua University) Beijing China
1Department of Engineering Physics Tsinghua University Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tianyu Ma
1Department of Engineering Physics Tsinghua University Beijing China
2Key Laboratory of Particle & Radiation Imaging Ministry of Education (Tsinghua University) Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tao Yang
3Department of Radiotherapy PLA General Hospital Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shouping Xu
3Department of Radiotherapy PLA General Hospital Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yaqiang Liu
1Department of Engineering Physics Tsinghua University Beijing China
2Key Laboratory of Particle & Radiation Imaging Ministry of Education (Tsinghua University) Beijing China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

574

Objectives: Prompt gamma (PG) imaging technique has been demonstrated to be very promising in real-time proton range monitoring in proton therapy. Despite the high correlation between PG and proton dose (PD) distribution, the detected PG cannot represent the delivered PD and be directly comparable with the planned PD. Here, we propose a deep learning based method to estimate the absolute PD from PG distribution.

Methods: Monte Carlo simulation was performed using GATE v8.0 with the physics list QGSP_BERT_HP_EMY. Head and neck CT scans were performed on 14 volunteers, and the data were used to generate the heterogeneous medium distribution in the simulation. For each volunteer, incident monenergistic pencil beams with the energy of 150±0.8 MeV was simulated from two different positions. The spot size of proton beam was 6 mm ×10 mm. The total number of protons for each incidence was 1.2×108. The 3D PD deposited in each volunteer’s brain and the emitted PG with energy ranging from 2 MeV to 8 MeV were stored in a 300×234×300 image with 1 mm ×1 mm ×1 mm voxel size. 31 2D slices were extracted from the each 3D image. A U-net model was implemented to learn the PG-to-PD transform. Integrated CT and simulated PG distribution were used as two input channels for training, while the simulated PD was used as the label. Patches with size of 200×200 were randomly extracted from the images and then flipped both horizontally and vertically to augment the data and avoid over-fitting. L2 was chosen as the loss function to obtain stable solution. 480 epochs with size of 1600 were trained. Each epoch contained 100 batches with mini-batch size of 16. The model was trained with 744 pairs from 12 volunteers and tested with the remaining 2 volunteers. To investigate the performance of this proposed method, the estimated PD was first visually compared with simulated PD. The mean projected range equal the depth of the distal 80% point of the Bragg peak in different slices, D80, was calculated to measure the range accuracy of estimated PD. Also, the relative error of the cumulative dose in 3D ROI was calculated to compare the estimated PD and simulated PD quantitatively by rendering 2D slices together.

Results: We observe very similar distribution between estimated PD and simulated PD. The range D80 bias is less than 0.5 mm for volunteer #1, where the Bragg peak locates in homogeneous brain regions. In volunteer #2, when the Bragg peak is near the nasal cavity, the range bias is less than 2.0 mm. The relative error of cumulative dose in a 3D ROI is less than 5% for all cases. Conclusion: The proposed deep learning based method satisfactorily recovers PD distribution from PG and corresponding CT data. This method shows great potential not only for range verification but also for quantitative 3D dose monitoring using PG in proton therapy. Further investigations are under way to implement the polyenergetic pencil beam scanning plans in simulation and estimation. Research Support: The research was supported by the National Natural Science Foundation of China (No. 81727807, No.11575096, No. 11605008) and National Key Research and Development (R&D) Plan of China (Grant ID. 2019YFF0302503 and 2016YFC0105405).

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
Wenzhuo Lu, Tianyu Ma, Tao Yang, Shouping Xu, Yaqiang Liu
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 574;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
Wenzhuo Lu, Tianyu Ma, Tao Yang, Shouping Xu, Yaqiang Liu
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 574;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Clinical feasibility of quantitative holmium-166 SPECT in presence of technetium-99m colloid
  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
Show more Physics, Instrumentation & Data Sciences

SPECT, Image Quality, Therapy

  • Clinical feasibility of quantitative holmium-166 SPECT in presence of technetium-99m colloid
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
  • Data-driven respiratory signal estimation from finely sampled projection data in conventional cardiac perfusion SPECT imaging.
Show more SPECT, Image Quality, Therapy

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire