Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Comparative Performance of NaI/MEGP vs CZT/MEHRS Collimators in SPECT Imaging of Patients Treated with 177Lu-DOTATATE

Brittany Varney, Gabriel Felder, Richard Jenkins, Nicholas Dunn, Delynn Silvestros, William Scheve, Saul Friedman and Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 330;
Brittany Varney
1Washington University School of Medicine, Division of Nuclear Medicine St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gabriel Felder
2Washington University St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Jenkins
3Washington University/BJC/SLCH Consortium St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nicholas Dunn
1Washington University School of Medicine, Division of Nuclear Medicine St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Delynn Silvestros
4Barnes Jewish Hospital Affton MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
William Scheve
5Barnes-Jewish Hospital St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Saul Friedman
2Washington University St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Laforest
6Washington University Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

330

Objectives: In order to expand the usability of the CZT camera to image higher energy nuclides such as 177Lutetium, this study aims to compare the novel CZT/Medium Energy High Resolution and Sensitivity (MEHRS) collimator to the current standard of care NaI/Medium Energy General Purpose (MEGP) collimator for 177Lu-DOTATATE imaging through quantitative analysis and visual assessment.

Methods: A total of 20 177Lu-DOTATATE therapy patients (200mCi therapy dose) are recruited. Patients are scheduled for same-day standard of care SPECT/CT imaging on a GE NM/CT 670 Pro standard NaI gamma camera using a MEGP collimator, and then undergo subsequent SPECT imaging on a GE NM/CT 670 CZT camera using a new MEHRS collimator. Image acquisition parameters were identical on both systems: 2 bed positions, 60 stops/bed position, 15 seconds/stop. The energy window was centered at 208KeV +/- 10%. Images from both the NaI and CZT acquisitions were fused with the CT obtained during the NaI acquisition for attenuation correction and anatomic correlation. Absolute calibration of the scanners was performed by imaging a uniform cylindrical phantom with known 177Lutetium activity concentration in water. Images were reconstructed using the same parameters for quantitative analysis: 4 iterations, 10 subsets, and no filter, using the ordered -subset estimation -maximization (OSEM algorithm) with resolution recovery, motion, scatter, and attenuation corrections. Images were reconstructed using the following parameters for visual analysis: 6 iterations, 10 subsets, Gauss post-filter 1.0 pixel FWHM, with resolution recovery, motion, scatter, and attenuation corrections. Quantitative analysis consist of comparison of absolute counts from each scanner, and SUV measurements of multiple prominent and representative lesions. Visual analysis consist of two blinded nuclear radiologists reviewing the images and rating each image set on a multi-point rating scale for image quality.

Results: Promising preliminary results from the first patient in our series demonstrated the CZT/MEHRS acquisition absolute counts to be 15% greater. Comparison of the 2 most prominent lesions revealed SUVmax of 66.8 and 51.9 on the CZT/MEHRS acquisition and similar values of 63.0 and 52.9 respectively on the NaI/MEGP acquisition. CZT/MEHRS produces high quality images by visual assessment.

Conclusions: Preliminary results indicate comparable quantitative assessment between new CZT/MEHRS collimator and standard of care NaI/MEGP acquisitions. Higher absolute counts on the CZT/MEHRS acquisition suggest greater absolute system sensitivity. CZT/MEHRS produces high quality images by visual assessment. Further results will be presented including the full subsets of patients and final conclusions. This work suggests that the CZT/MEHRS camera can effectively be used for clinical assessment of 177Lu-DOTATATE.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparative Performance of NaI/MEGP vs CZT/MEHRS Collimators in SPECT Imaging of Patients Treated with 177Lu-DOTATATE
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Comparative Performance of NaI/MEGP vs CZT/MEHRS Collimators in SPECT Imaging of Patients Treated with 177Lu-DOTATATE
Brittany Varney, Gabriel Felder, Richard Jenkins, Nicholas Dunn, Delynn Silvestros, William Scheve, Saul Friedman, Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 330;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparative Performance of NaI/MEGP vs CZT/MEHRS Collimators in SPECT Imaging of Patients Treated with 177Lu-DOTATATE
Brittany Varney, Gabriel Felder, Richard Jenkins, Nicholas Dunn, Delynn Silvestros, William Scheve, Saul Friedman, Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 330;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
  • Keel-Edge Height Selection for Improved Multi-Pinhole 123I Brain SPECT Imaging
Show more Physics, Instrumentation & Data Sciences

Instrumentation - Clinical imaging and optimization

  • Dynamic range of the newest digital PET-CT scanner for myocardial blood flow quantification using Rubidium-82
  • Improved Sentinel Node Localization in Patients with Newly Diagnosed Melanoma Utilizing a Fully Digital CZT SPECT/CT System Versus a Conventional NaI SPECT/CT System.
  • A simplified brain-shaped phantom to evaluate O-15 image quality of digital photon counting PET-CT
Show more Instrumentation - Clinical imaging and optimization

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire