Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting Report

5-year progress on imaging performance of commercial PET scanners: a multi-center study towards harmonization of FDG-PET

Go Akamatsu, Naoki Shimada, Keiichi Matsumoto, Hiromitsu Daisaki, Kazufumi Suzuki, Keiichi Oda, Michio Senda, Ukihide Tateishi and Takashi Terauchi
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1398;
Go Akamatsu
1National Institute of Radiological Sciences (NIRS-QST) Chiba Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Naoki Shimada
2Cancer Institute Hospital Tokyo Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Keiichi Matsumoto
3Kyoto College of Medical Sciense Kyoto Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiromitsu Daisaki
4Department of Radiological Technology Gunma Prefectural College of Health Sciences Gunma Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kazufumi Suzuki
5Dokkyo Medical University Hospital Tochigi Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Keiichi Oda
6Hokkaido University of Science Sapporo Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michio Senda
7Kobe City Medical Center General Hospital Kobe Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ukihide Tateishi
8Tokyo Medical and Dental University School of Medi Tokyo Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takashi Terauchi
2Cancer Institute Hospital Tokyo Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1398

Objectives: Whole-body FDG-PET plays key roles in detection, staging, and characterization of malignant tumors. In oncologic clinical studies and trials, a standardized uptake value (SUV) is often used as a quantitative biomarker although it is considerably affected by many factors such as imaging protocols, PET scanner specifications, and reconstruction parameters. On the other hand, clinical PET scanner performance has rapidly progressed by novel technologies such as point-spread function, time-of-flight, and penalized likelihood reconstruction. To establish a feasible and practical methodology for harmonization of FDG-PET, we are investigating quantitative physical performance of recent clinical PET scanners with the image quality phantom. Here, we compared the recent results with the phantom data that had been acquired about 5 years ago with the PET scanners of those days*.

Methods: A total of 19 types of recent commercial PET/CT scanners used in a total of 16 centers were tested in this study. Of these, 15 scanners had TOF measurement capability. A NEMA image quality phantom having six spheres (10-37 mm in diameter) was used for image quality evaluation. The sphere-to-background radioactivity ratio was 4. The background radioactivity concentration was 2.53-2.65 kBq/mL. PET images with various scanning duration (30-300 sec, 1800 sec) were reconstructed using a clinical reconstruction setting in each site. For visual assessment, the PET images were evaluated according to the detectability of the 10-mm hot sphere on a 3-step scale (0, not visualized; 1, visualized, but similar hot spots are observed elsewhere; 2, identifiable) by five observers. We measured the percent contrast of the 10-mm hot sphere (QH,10mm), the background variability (N10mm), the coefficient of variation in the background area (CVBG), and the relative recovery coefficient (RC). The data were compared with the previous data published in 2014* that had been acquired with a total of 13 PET scanners released before 2011.

Results: On the PET images with 120 sec acquisition, the median value for all scanners was 2.0 for visual detectability score, 28.7% for QH,10mm, 7.6% for N10mm, and 9.6% for CVBG. Those of the previous data was 0.8 for visual detectability score, 13.7% for QH,10mm, 8.3% for N10mm, and 12.3% for CVBG*. The relative RCs for the spheres with diameters of 22 mm or smaller were higher than the previous data. Overall, the visual detectability of the 10-mm sphere, contrast, image noise, and RC were clearly better than the previous data.

Conclusions: We have revealed that imaging performance of commercial PET scanners has made remarkable progress in the past 5 years. For practical harmonization of FDG-PET, regular updates of standard phantom test methodology and harmonizing criteria are essential to adapt to new PET scanners with better imaging performance. (*Fukukita H, et al. Ann Nucl Med. 2014;28:693-705)

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
5-year progress on imaging performance of commercial PET scanners: a multi-center study towards harmonization of FDG-PET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
5-year progress on imaging performance of commercial PET scanners: a multi-center study towards harmonization of FDG-PET
Go Akamatsu, Naoki Shimada, Keiichi Matsumoto, Hiromitsu Daisaki, Kazufumi Suzuki, Keiichi Oda, Michio Senda, Ukihide Tateishi, Takashi Terauchi
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1398;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
5-year progress on imaging performance of commercial PET scanners: a multi-center study towards harmonization of FDG-PET
Go Akamatsu, Naoki Shimada, Keiichi Matsumoto, Hiromitsu Daisaki, Kazufumi Suzuki, Keiichi Oda, Michio Senda, Ukihide Tateishi, Takashi Terauchi
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1398;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Rest Dose Spillover Correction of Stress Blood Flow Measurements in Digital Rb-82 Myocardial Perfusion PET/CT Imaging
  • Radiolabeled hyaluronic acid (HA) fragments for lymphatic imaging
  • Reduction of injected activity for MBF with a CZT Cardiac SPECT Camera
Show more

Data Analysis & Management (Poster Session)

  • Activity assays for the alpha-emitting radionuclide Ra-224 adsorbed onto CaCO3 microparticles
  • A Comparison of Semi-Automated Brown Adipose Tissue Segmentation Methods
Show more Data Analysis & Management (Poster Session)

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire