Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

On the Accuracy of Voxel-Based Kidney Dosimetry

Johannes Tran-Gia and Michael Lassmann
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 263;
Johannes Tran-Gia
1Nuclear Medicine University of Wuerzburg Wuerzburg Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Lassmann
1Nuclear Medicine University of Wuerzburg Wuerzburg Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

263

Aim: Due to continuous improvements in quantitative SPECT/CT imaging, voxel-based dosimetry for radionuclide therapies has aroused growing interest as it promises the visualization of differences in absorbed doses on a sub-organ level. In this work, a non-uniform kidney distribution was mimicked by a 3D-printed 2-compartment kidney phantom filled with Lu-177 solutions of different activity concentration. Subsequently, SPECT/CT-based voxel-based dosimetry was performed to assess the potential of voxel-based absorbed dose assessments. Additionally, the potential of the PETPVC partial-volume correction tool was investigated [1]. MATERIALS AND METHODS: Phantom: 3D-printed kidney filled with Lu-177 solution (cortex: 100 mL @ 1.89 MBq/mL, medulla: 50 mL @ 0.36 MBq/mL), placed inside a water-filled NEMA body phantom [2]. Activity concentrations were measured with a calibrated HPGe detector. Acquisition: Siemens Intevo Bold SPECT/CT, medium-energy collimator, 2×60 views of 30 s, continuous non-circular Orbit. Reconstruction: xSPECT Quant (voxel-size: 2 mm, output: Bq/mL). Different combinations of iterations (12/24/36/48) and Gaussian post-filters (0/1/2/4/8/16 mm FWHM). CT-based attenuation correction, triple-energy-window scatter correction. Partial-Volume Correction (PVC): Interpolation of VOIs to CT resolution (1 mm isotropic), application of PETPVC with iterative Young and predetermined SPECT resolutions (11-22 mm depending on the reconstruction [3]). Absorbed Dose Distributions: Convolution of SPECT/CT images [MBq/mL] with a Monte-Carlo based, pre-tabulated Lu-177 dose kernel [mGy/MBq/s] [4]. Multiplication with voxel volume [mL] and time-integrated activity coefficient (assuming 51h tissue-specific kidney half-life [5]) yields absorbed dose [Gy] in each voxel. Total Absorbed Doses: Mean over dose distribution in CT-based cortex and medulla VOIs (post-processing in [6]). Nominal Absorbed Doses: Calculation based on 2 uniform activity distributions placed in a voxel representation of the 3D printing designs. RESULTS AND DISCUSSION: Absorbed Dose Distributions: SPECT/CT image reconstruction blurs the 2 discrete absorbed dose values into a continuous distribution, shifting the absorbed voxel doses towards smaller values. While this effect is slightly improved by applying more iterations, it is further enhanced by post-filtering. After PETPVC, the distribution of the absorbed dose voxels is separated into 2 continuous parts, leading to a better agreement between SPECT/CT-based and nominal values. Total Absorbed Doses: The nominal absorbed doses were calculated as 7.7/1.6 Gy (cortex/medulla). SPECT/CT imaging resulted in total absorbed doses ranging from 4.0-5.3 Gy (cortex) and 4.4-3.2 Gy (medulla, 12-48 iterations). PETPVC improved the accuracy to 7.3-9.4 Gy (cortex) and 3.9-1.2 Gy (medulla). The best agreement to the nominal absorbed doses was reached after PVC for 12 iterations (cortex, −5.2%) and for 36 iterations (medulla, −4.5%).

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
View this table:
  • View inline
  • View popup

Table 1: Nominal and SPECT/CT-Based Sub-Organ Absorbed Doses (Gy)

CONCLUSION: Our study shows that Lu-177 quantitative SPECT/CT imaging of the kidneys leads to voxel-based dose distributions largely differing from the real organ distribution. Despite large errors in the absorbed voxel doses, an accuracy of 5% was achieved for total sub-organ absorbed doses by means of well-calibrated SPECT/CT imaging in combination with well-defined VOIs. PETPVC not only improved the visual match between SPECT/CT-based and nominal dose distributions, it also largely decreased the error in the total sub-organ absorbed doses. In conclusion, the concept of voxel-based dosimetry should be treated with caution. Specifically, it should be kept in mind that the absorbed dose distribution is only a convolved version of the underlying SPECT reconstruction. LITERATURE: [1] Thomas; PhysMedBiol; 2016; 61(22). [2] Tran-Gia; JNuclMed; 2016; 59(4). [3] Tran-Gia; JNuclMed; 2019; 60(1). [4] Kletting; ZMedPhys; 2015; 25(3). [5] Hänscheid; JNuclMed; 2018; 59(1). [6] Fedorov; MagnResonImaging; 2012; 30(9).

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
On the Accuracy of Voxel-Based Kidney Dosimetry
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
On the Accuracy of Voxel-Based Kidney Dosimetry
Johannes Tran-Gia, Michael Lassmann
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 263;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
On the Accuracy of Voxel-Based Kidney Dosimetry
Johannes Tran-Gia, Michael Lassmann
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 263;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
Show more Physics, Instrumentation & Data Sciences

Cardiac and Cancer Imaging (Data Management, PIDS)

  • A 4D Statistical Atlas of the Human Heart from Gated PET Myocardial Perfusion Imaging
  • SPECT/CT studies for dosimetry after PRRT: impact of reduced number of studies on organ dose calculation and patient management
Show more Cardiac and Cancer Imaging (Data Management, PIDS)

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire