Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction

Yihuan Lu, Kathryn Fontaine, Jean-Dominique Gallezot, Tim Mulnix, Vladimir Panin, Judson Jones, Michael Casey, Richard Carson and Chi Liu
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 105;
Yihuan Lu
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kathryn Fontaine
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jean-Dominique Gallezot
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tim Mulnix
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vladimir Panin
1Siemens Healthcare Knoxville TN United States
2Siemens Healthcare Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Judson Jones
1Siemens Healthcare Knoxville TN United States
2Siemens Healthcare Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Casey
1Siemens Healthcare Knoxville TN United States
2Siemens Healthcare Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Carson
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chi Liu
3Yale University New Haven CT United States
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

105

Objectives: Recently, continuous-bed-motion (CBM) acquisition of PET was released by Siemens [1], which enhanced patient comfort [2] and demonstrated advantages in spatial uniformity and end-plane imaging as compared to the conventional step-and-shoot (SS) acquisition [3]. In the past, we have developed list-mode (LM) reconstruction equipped with respiratory event-by-event non-rigid motion correction (EBE-NRMC) [4] for single-bed PET that uses all counts. However, the existing EBE-NRMC method was not readily applicable to CBM due to the constantly-moving field-of-view during the acquisition. In this study, by taking the bed motion into account, we developed the first list-mode PET reconstruction with event-by-event non-rigid respiratory motion correction for whole-body (WB) CBM acquisition.

Methods: During the CBM acquisition, bed position information, was encoded into the LM data stream. The bed motion can be viewed as rigid axial-direction patient motion. Therefore, the bed position information can be used to reposition the detector-pair coordinates of the line-of-response (LOR) for each event in the axial direction, to account for bed motion. Since normalization was computed for each LOR, there was no difference in CBM as compared to single-bed LM reconstruction [5]. The scatter correction was performed using 3D single-scatter-simulation technique with slice-by-slice calculated scaling factor in axial direction. CT-attenuation map was used for attenuation correction. Our approach reconstructs the entire WB image with only one LM reconstruction, whereas Siemens’ sinogram-based approach performs “chunk-by-chunk” reconstruction [1], in which the number of reconstructions is proportional to the length of a subject. To build the respiratory motion model, ANZAI-based respiratory-gated MLAA reconstruction was first performed [4], followed by inter-gate non-rigid image registrations. The internal-external correlation (INTEX) technique was then used to build a respiratory motion model, which describes a continuous relationship between each voxel’s movement (internal) and the ANZAI trace (external) [4]. The motion model, along with CT-attenuation map, list-mode data and bed motion information were then used in the final LM EBE-NRMC reconstruction, to achieve respiratory motion corrected reconstruction for whole-body CBM data. Evaluation was performed on four subjects, 2 healthy control (HC) and 2 lung cancer (LC) patients, who were scanned 60-90 min post 10 mCi 18F-FDG injection on Siemens Biograph mCT. A protocol of 6 WB passes at 5 min/pass was used. LM data from all passes (30 min) were reconstructed into one WB image. Organ-specific motion amplitude, and the % increase in SUV from uncorrected to EBE-NRMC corrected values were reported for each subject.

Results: Compared with Siemens reconstruction, LM reconstruction showed comparable results in visual comparison (fig. 1(A-C)). Siemens recon appears to be smoother than LM recon due to different point-spread-functions were used. LM recon shows sharper brain structure (fig. 1(A,B)). Respiratory motion correction is effective, even for very small tumors with small motion amplitude, i.e. mean 140 mm3 in volume with <4mm motion (fig.1 (E, G)). SUV increase for large organs after respiratory motion correction is approximately proportional to the motion amplitude (fig.1 (E-G)).

Conclusions: We have developed list-mode reconstruction for continuous-bed-motion acquisition, which is comparable to Siemens reconstruction without motion correction. Whole-body event-by-event non-rigid respiratory motion correction shows superiority in SUV and resolution recovery as compared to no motion correction. This approach has the potential to produce optimal WB static and dynamic images. References: [1] Panin et al., PMB, 2014. [2] Schatka et al., EJNMMI, 2016. [3] Osborne, et al., AJNMMI, 2015. [4] Lu et al., JNM, 2018. [5] Jin et al., PMB, 2013.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
Yihuan Lu, Kathryn Fontaine, Jean-Dominique Gallezot, Tim Mulnix, Vladimir Panin, Judson Jones, Michael Casey, Richard Carson, Chi Liu
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 105;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
Yihuan Lu, Kathryn Fontaine, Jean-Dominique Gallezot, Tim Mulnix, Vladimir Panin, Judson Jones, Michael Casey, Richard Carson, Chi Liu
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 105;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Keel-Edge Height Selection for Improved Multi-Pinhole 123I Brain SPECT Imaging
  • Ultra-Fast Reconstruction of Short List-Mode PET Data Frames for Real-Time Visualization and Processing
  • Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
Show more Physics, Instrumentation & Data Sciences

Quantitative PET and PET/MR (Image Generation)

  • Impact of attenuation correction on image-derived input functions and cerebral blood flow quantification with simultaneous [15O]-water PET/MRI
  • MR-Based PET Attenuation Correction using 3D UTE/Multi-Echo Dixon: In Vivo Results
Show more Quantitative PET and PET/MR (Image Generation)

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire