Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticlePhysics and Instrumentation
Open Access

Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model

Richard Manber, Kris Thielemans, Brian F. Hutton, Simon Wan, Francesco Fraioli, Anna Barnes, Sébastien Ourselin, Simon Arridge and David Atkinson
Journal of Nuclear Medicine September 2018, 59 (9) 1467-1473; DOI: https://doi.org/10.2967/jnumed.117.191460
Richard Manber
1Centre for Medical Imaging, Division of Medicine, University College London, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kris Thielemans
2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Brian F. Hutton
2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
3Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Simon Wan
2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Francesco Fraioli
2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anna Barnes
2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sébastien Ourselin
4Centre for Medical Imaging Computing, Faculty of Engineering, University College London, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Simon Arridge
4Centre for Medical Imaging Computing, Faculty of Engineering, University College London, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Atkinson
1Centre for Medical Imaging, Division of Medicine, University College London, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 59 no. 9 1467-1473
DOI 
https://doi.org/10.2967/jnumed.117.191460
PubMed 
29523630

Published By 
Society of Nuclear Medicine
Print ISSN 
0161-5505
Online ISSN 
2159-662X
History 
  • Received for publication September 10, 2017
  • Accepted for publication January 8, 2018
  • Published online September 4, 2018.

Article Versions

  • previous version (March 9, 2018 - 05:56).
  • previous version (March 15, 2018 - 13:16).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2018 by the Society of Nuclear Medicine and Molecular Imaging. Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

Author Information

  1. Richard Manber1,
  2. Kris Thielemans2,
  3. Brian F. Hutton2,3,
  4. Simon Wan2,
  5. Francesco Fraioli2,
  6. Anna Barnes2,
  7. Sébastien Ourselin4,
  8. Simon Arridge4 and
  9. David Atkinson1
  1. 1Centre for Medical Imaging, Division of Medicine, University College London, London, United Kingdom
  2. 2Institute of Nuclear Medicine, UCL and UCL Hospitals, London, United Kingdom
  3. 3Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia; and
  4. 4Centre for Medical Imaging Computing, Faculty of Engineering, University College London, London, United Kingdom
  1. For correspondence or reprints contact: Richard Manber, Institute of Nuclear Medicine, 5th Floor, Tower, University College Hospital, 235 Euston Rd., London, NW1 2BU, U.K. E-mail: manber.richard{at}gmail.com
View Full Text

Statistics from Altmetric.com

Cited By...

  • 13 Citations
  • 12 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • What scans we will read: imaging instrumentation trends in clinical oncology
    Thomas Beyer, Luc Bidaut, John Dickson, Marc Kachelriess, Fabian Kiessling, Rainer Leitgeb, Jingfei Ma, Lalith Kumar Shiyam Sundar, Benjamin Theek, Osama Mawlawi
    Cancer Imaging 2020 20 1
  • AI-based applications in hybrid imaging: how to build smart and truly multi-parametric decision models for radiomics
    Isabella Castiglioni, Francesca Gallivanone, Paolo Soda, Michele Avanzo, Joseph Stancanello, Marco Aiello, Matteo Interlenghi, Marco Salvatore
    European Journal of Nuclear Medicine and Molecular Imaging 2019 46 13
  • PET respiratory motion correction: quo vadis?
    F Lamare, A Bousse, K Thielemans, C Liu, T Merlin, H Fayad, D Visvikis
    Physics in Medicine & Biology 2022 67 3
  • Rigid-body motion correction in hybrid PET/MRI using spherical navigator echoes
    P M Johnson, R Taylor, T Whelan, J D Thiessen, U Anazodo, M Drangova
    Physics in Medicine & Biology 2019 64 8
  • Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
    Irene Polycarpou, Georgios Soultanidis, Charalampos Tsoumpas
    Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences 2021 379 2204
  • Design of an anthropomorphic PET phantom with elastic lungs and respiration modeling
    David G. Black, Yas Oloumi Yazdi, Jeremy Wong, Roberto Fedrigo, Carlos Uribe, Dan J. Kadrmas, Arman Rahmim, Ivan S. Klyuzhin
    Medical Physics 2021 48 8
  • Impact of respiratory motion on 18F‐FDG PET radiomics stability: Clinical evaluation with a digital PET scanner
    Yu‐Hung Chen, Kuo‐Yi Kan, Shu‐Hsin Liu, Hsin‐Hon Lin, Kun‐Han Lue
    Journal of Applied Clinical Medical Physics 2023 24 12
  • Monitoring mouse brain perfusion with hybrid magnetic resonance optoacoustic tomography
    Wuwei Ren, Xosé Luís Deán-Ben, Zhiva Skachokova, Mark-Aurel Augath, Ruiqing Ni, Zhenyue Chen, Daniel Razansky
    Biomedical Optics Express 2023 14 3
  • Clinical PET/MRI
    Angel Torrado-Carvajal, Ciprian Catana
    2023
  • Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI
    Hui Li, Xiangxi Meng, Xiangping Guan, Nina Zhou, Hui Liu, Yan Zhang, Boqi Yu, Hua Zhu, Nan Li, Zhi Yang
    Clinical Nuclear Medicine 2021 46 4

Article usage

Article usage: March 2018 to April 2025

AbstractFullPdf
Mar 2018681094
Apr 2018248032
May 2018139031
Jun 2018103022
Jul 201898011
Aug 201896010
Sep 201867136106
Oct 20182824169
Nov 20181072222
Dec 201871188
Jan 2019952222
Feb 2019731814
Mar 2019972232
Apr 2019711922
May 201929316
Jun 201937613
Jul 201957178
Aug 2019281014
Sep 20192106
Oct 2019531118
Nov 20193959
Dec 20195814
Jan 20202527
Feb 202029411
Mar 202026319
Apr 202019313
May 202031159
Jun 202018414
Jul 202022235
Aug 20202629
Sep 20202567
Oct 202024511
Nov 202017414
Dec 20202498
Jan 2021251514
Feb 2021766
Mar 2021131223
Apr 2021474
May 2021121413
Jun 20211064
Jul 202118916
Aug 2021131417
Sep 202117511
Oct 202112424
Nov 202110525
Dec 2021161213
Jan 202211922
Feb 202212133
Mar 20223711
Apr 20221588
May 20224921
Jun 202271111
Jul 20226179
Aug 202291113
Sep 20229910
Oct 202241215
Nov 20223138
Dec 20224136
Jan 2023161512
Feb 20234106
Mar 202391415
Apr 20236194
May 20237147
Jun 2023020
Jul 20234158
Aug 2023111116
Sep 2023823
Oct 20233286
Nov 2023114217
Dec 20236241
Jan 202412156
Feb 2024278
Mar 20243511
Apr 202454411
May 20240193
Jun 202452011
Jul 202471815
Aug 202441311
Sep 202411295
Oct 20243307
Nov 20243196
Dec 20243198
Jan 20253911
Feb 2025144914
Mar 202582923
Apr 2025153722
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 59 (9)
Journal of Nuclear Medicine
Vol. 59, Issue 9
September 1, 2018
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
Richard Manber, Kris Thielemans, Brian F. Hutton, Simon Wan, Francesco Fraioli, Anna Barnes, Sébastien Ourselin, Simon Arridge, David Atkinson
Journal of Nuclear Medicine Sep 2018, 59 (9) 1467-1473; DOI: 10.2967/jnumed.117.191460

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
Richard Manber, Kris Thielemans, Brian F. Hutton, Simon Wan, Francesco Fraioli, Anna Barnes, Sébastien Ourselin, Simon Arridge, David Atkinson
Journal of Nuclear Medicine Sep 2018, 59 (9) 1467-1473; DOI: 10.2967/jnumed.117.191460
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard
  • A Multicenter Study on Observed Discrepancies Between Vendor-Stated and PET-Measured 90Y Activities for Both Glass and Resin Microsphere Devices
  • Ultra-Fast List-Mode Reconstruction of Short PET Frames and Example Applications
Show more Physics and Instrumentation

Similar Articles

Keywords

  • motion correction
  • PET/MRI
  • Lesion detection
  • Lesion Quantification
SNMMI

© 2025 SNMMI

Powered by HighWire