Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis: Data Analysis & Management

A website for voxel dosimetry: Free databases and on-line calculations of voxel S values

Nico Lanconelli, Massimiliano Pacilio, Francesca Botta, Leonel A Torres Aroche, Nestor Cornejo Diaz, Marco Coca Perez, Sergio Lo Meo, Giuseppina Amalia Di Dia and Marta Cremonesi
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2106;
Nico Lanconelli
2Department of Physics, Alma Mater Studiorum University of Bologna, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Massimiliano Pacilio
1Medical Physics Department, Azienda Ospedaliera S Camillo Forlanini, Rome, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Francesca Botta
3Department of Medical Physics, Istituto Europeo di Oncologia, Milano, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Leonel A Torres Aroche
4Medical Physics Department, Centre for Clinical Researches, Havana, Cuba
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nestor Cornejo Diaz
5Centre for Radiological Protection and Hygiene, Havana, Cuba
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marco Coca Perez
4Medical Physics Department, Centre for Clinical Researches, Havana, Cuba
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sergio Lo Meo
2Department of Physics, Alma Mater Studiorum University of Bologna, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Giuseppina Amalia Di Dia
3Department of Medical Physics, Istituto Europeo di Oncologia, Milano, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marta Cremonesi
3Department of Medical Physics, Istituto Europeo di Oncologia, Milano, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

2106

Objectives Voxel dosimetry can be defined as the calculation of radiation absorbed dose to tissue regions with dimensions ranging from hundreds of micrometers to a few centimeters. Voxel dosimetry is based on activity quantification with tomographic imaging or autoradiographic techniques, and is of particular interest in radionuclide targeted therapy applications. The voxel cumulative activity can be derived from SPECT or PET, and tissue inhomogeneities from CT. By using this approach, the activity and dose distributions can be determined at the maximal experimental resolution of the radiotracer distribution. Direct radiation transport simulation with Monte Carlo (MC) codes can account for non-uniform source and density distribution, whereas convolution calculation with voxel S values is based on the hypothesis of uniform density distribution. The latter approach cannot account for non-uniform tissue density distribution, but it could result more suitable for most of the clinical physicists, as the MC codes are not always available in clinical settings. Nevertheless, the use of voxel S values has been limited because of the lack of data for different voxel dimensions and radionuclides.

Methods To encourage the spread of this method, a web site has been instituted. Tabulations of voxel S values calculated with MC codes are now available for different voxel dimensions and radionuclides of interest.

Results MC data underwent a severe accuracy control, whose results are reported in the present study.

Conclusions Further work in progress consists to the calculation of S values at the voxel level with convolution of dose point kernels, by means of an on-line software providing real time results for any voxel dimensions

Back to top

In this issue

Journal of Nuclear Medicine
Vol. 52, Issue supplement 1
May 2011
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A website for voxel dosimetry: Free databases and on-line calculations of voxel S values
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
A website for voxel dosimetry: Free databases and on-line calculations of voxel S values
Nico Lanconelli, Massimiliano Pacilio, Francesca Botta, Leonel A Torres Aroche, Nestor Cornejo Diaz, Marco Coca Perez, Sergio Lo Meo, Giuseppina Amalia Di Dia, Marta Cremonesi
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2106;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
A website for voxel dosimetry: Free databases and on-line calculations of voxel S values
Nico Lanconelli, Massimiliano Pacilio, Francesca Botta, Leonel A Torres Aroche, Nestor Cornejo Diaz, Marco Coca Perez, Sergio Lo Meo, Giuseppina Amalia Di Dia, Marta Cremonesi
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2106;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis: Data Analysis & Management

  • The effect of alternate background and kidney regions of interest and use of geometric mean versus posterior images on the computation of differential renal function with MAG-3
  • Statistical modeling of the PET maximum voxel
  • Automated program for analyzing striatal uptake of DaTSCAN SPECT images in humans suspected of Parkinson's disease
Show more Instrumentation & Data Analysis: Data Analysis & Management

Data Analysis and Management Posters

  • The use of calibrated phantoms to assess the accuracy of PET-CT image quantification for 64Cu.
  • A deformable registration workflow for motion correction in PET-CT guided biopsy
  • Association of Image-derived Blood Input Function with Patient Characteristics in Dynamic FDG-PET: A Pilot Study
Show more Data Analysis and Management Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire