Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation and Data Analysis: Instrumentation

Evaluation of a multi-camera visual-tracking system for detecting and correcting body motion in cardiac SPECT

P. Hendrik Pretorius, Joyeeta Mitra, Joseph E McNamara, Karen Johnson and Michael King
Journal of Nuclear Medicine May 2009, 50 (supplement 2) 413;
P. Hendrik Pretorius
1University of Massachusetts Medical School, Div Nuclear Medicine, Worcester, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joyeeta Mitra
1University of Massachusetts Medical School, Div Nuclear Medicine, Worcester, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joseph E McNamara
1University of Massachusetts Medical School, Div Nuclear Medicine, Worcester, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Karen Johnson
1University of Massachusetts Medical School, Div Nuclear Medicine, Worcester, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael King
1University of Massachusetts Medical School, Div Nuclear Medicine, Worcester, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

413

Objectives Body motion of ~13 mm is sufficient to cause minor to moderate defects in Cardiac SPECT. We designed a clinical motion-monitoring system using multiple near-infrared cameras from Vicon to stereo-image small retro-reflective markers on strechy bands wrapped about the chest and abdomen. The goal was to evaluate in patients the accuracy with which the motion can be corrected when incorporated in iterative reconstruction with attenuation and detector response compensation.

Methods Twelve patients (8 men, 4 women thus far) undergoing Tl-201 stress-rest cardiac perfusion imaging were ask to move a small amount during a second rest acquisition directly after a first rest with Beacon (Philips Medical, Milpitas, CA) transmission. The visual tracking system (VTS) contineously monitored patients during the entire study. The first rest served as baseline for comparison, while the second was reconstructed with a) no motion correction, b) VTS determined motion correction, and c) the standard motion correction software in our clinic. Indenpendent polar-map quantification using a site-specific normal database was used for evaluation.

Results The VTS corrected slices compared more favorably with the first rest study in 11 of the 12 patients than slices corected using the clinical software. Also, in the majority of cases the diagnosis (as given by polar-map quantifiction) were not significntly altered with VTS determined motion correction while the clinical software was wrong in 50%. Currently, 3DOF compensation is more robust than 6DOF compensation.

Conclusions We were able to show that VTS motion detection and correction is possible in a routine clinical setting.

Research Support NIH R01 EB001457, R01 HL091017, and Philips Medical Systems

  • © 2009 by Society of Nuclear Medicine
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 50, Issue supplement 2
May 2009
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of a multi-camera visual-tracking system for detecting and correcting body motion in cardiac SPECT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Evaluation of a multi-camera visual-tracking system for detecting and correcting body motion in cardiac SPECT
P. Hendrik Pretorius, Joyeeta Mitra, Joseph E McNamara, Karen Johnson, Michael King
Journal of Nuclear Medicine May 2009, 50 (supplement 2) 413;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Evaluation of a multi-camera visual-tracking system for detecting and correcting body motion in cardiac SPECT
P. Hendrik Pretorius, Joyeeta Mitra, Joseph E McNamara, Karen Johnson, Michael King
Journal of Nuclear Medicine May 2009, 50 (supplement 2) 413;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation and Data Analysis: Instrumentation

  • Time of flight camera (TOF) for contact-less and marker-less 3D respiratory motion detection
  • Performance evaluation of a newly developed semiconductor small animal PET scanner Sumitomo MIP-100
  • Comparison of measurement and simulation using GATE with optical photon tracking for a DOI PET detector
Show more Instrumentation and Data Analysis: Instrumentation

SPECT

  • High-resolution photon counting using a lens-coupled EMCCD gamma camera
  • 3D spatial resolution map and sensitivity characterization of a dedicated cardiac CZT SPECT camera
  • Flat panel X-ray detector based SPECT/CT
Show more SPECT

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire