Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherClinical Investigations

123I: Almost a Designer Radioiodine for Thyroid Scanning

Hee-Myung Park
Journal of Nuclear Medicine January 2002, 43 (1) 77-78;
Hee-Myung Park
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

The merits of 123I as a thyroid scanning agent have been lauded since it became possible to produce 123I using a cyclotron. In 1967, Rhodes et al. (1) stated: “In the past, the radionuclides used in biology and medicine have been chosen primarily because they were available rather than because they were most suitable for the problem at hand. However, because it is now possible to produce a much wider selection of nuclides, it is becoming feasible to select the best nuclide for a given medical application.”

There are 24 possible radioisotopes of iodine. The first radioiodine used in humans was cyclotron-produced 128I, but its half-life of 25 min was too short for clinical use. Four of the remaining radioisotopes have been tried clinically: 123I, 125I, 131I, and 132I. In 1966, Myers (2) stated: “I-123 fulfills the criteria for an ideal gamma isotope more than any other radioisotopes of iodines.” The first commercially available 123I was produced directly from the 126Te (p, 4n) 123I reaction and had impurities including 124I, a positron emitter. Wellman and Anger (3) advocated the use of 123I and pinhole gamma cameras for thyroid imaging and stated: “Further development of indirect methods of production of high-purity I-123, especially if made more economical, will greatly increase the potential use of I-123.”

Indeed, 123I is the most suitable isotope of iodine for the diagnostic study of thyroid diseases. The half-life of 13.3 h is ideal for the 24-h iodine uptake test. The energy of the photon, 159 keV, is ideal for the NaI crystal detector of current gamma cameras and also for the pinhole collimators. It has much greater photon flux than 131I. It gives approximately 20 times the counting rate of 131I for the same administered dose (4). The radiation burden to the thyroid is far less (1%) than that of 131I. Scanning a thyroid remnant or metastasis with 123I does not cause stunning because of its low radiation burden. 123I is almost a designer isotope of iodine for imaging thyroid tissue and thyroid cancer metastasis. High-purity 123I is currently available using the 127I (p, 5n) 123Xe-β+-123I reaction.

Although 131I is cheaper in price, it has many drawbacks as a scanning agent, including the thyroid stunning effect. Numerous studies have shown that scanning with 131I in multimillicurie doses before radioablation therapy can stun the thyroid tissue (5). Stunned tissue then loses its iodine trapping function partially or completely and also temporarily or permanently. This is a radiobiologic phenomenon, and the degree of stunning depends on the absorbed radiation dose to the remnant thyroid tissue or metastatic lesions.

The question to be resolved now seems to be: How effective is 123I as a scanning agent in the management of thyroid cancer patients? We compared the scans using a small dose (11.1 MBq [300 μCi]) of 123I and those using a multimillicurie dose (111–370 MBq [3–10 mCi]) of 131I with the gold standard 131I scan after therapy (3,700 MBq [100 mCi]). The sensitivities of the scans in detecting the thyroid remnant using a high dose (111–370 MBq [3–10 mCi]) and a low dose (11.1 MBq [0.3 mCi]) of 123I were 92.9% and 89.5%, respectively (6). Britton et al. (4) compared the diagnostic sensitivity of 123I (185 MBq [5 mCi]) whole-body imaging with that of scans after therapy in 131I tracer-negative but thyroglobulin-positive patients. The sensitivity of 123I was 100%.

Mandel et al. (7) studied 14 consecutive patients with thyroid cancer and showed that an 123I (48.1–55.5 MBq [1.3–1.5 mCi]) scan at 5 h was superior to an 131I (111 MBq [3 mCi]) scan at 48 h in revealing thyroid remnants. They used the 131I scans obtained after therapy (3,700–5,550 MBq [100–150 mCi]) as the gold standard. The patients received the therapy dose within 5 d of the diagnostic scan. The sensitivity of the 123I scan was 100%. In this issue of The Journal of Nuclear Medicine, this group reports the results of their study of 99 patients with differentiated thyroid cancer (8). They compared a 5-h scan with a 24-h scan using 123I and found the 24-h scan was better. They also showed that the 24-h 123I (56 MBq [1.5 mCi]) scans were concordant with scans obtained 7 d after 131I therapy in 93% of patients. The sensitivity is excellent for a diagnostic study. In their series, the scans obtained after therapy revealed more foci of thyroid remnants but did not identify additional sites of tumor involvement.

Despite the desirable characteristics of 123I and the reported superiority to 131I as a diagnostic scanning agent, its usage has been restricted by its higher cost and limited availability. However, the difference in the cost of radioiodines is relatively small considering the total cost of the whole-body scanning procedure. It is hoped that 123I will become more widely available at lower costs in the future so that patients with thyroid cancers can benefit from its use.

Footnotes

  • Received Jul. 23, 2001; revision accepted Jul. 31, 2001.

    For correspondence or reprints contact: Hee-Myung Park, MD, Department of Nuclear Medicine, Wichard Memorial Hospital, 1001 W. 10th St., Indianapolis, IN 46202.

    E-mail: hmpark{at}iupui.edu

REFERENCES

  1. Rhodes BA, Wagner HN Jr, Gerard M. Iodine-123: development and usefulness of a new radiopharmaceutical. Isot Radiat Technol 1967;4:275–280.
  2. ↵
    Myers W. Radioisotopes of iodine. In: Radioactive Pharmaceuticals: Proceedings of an Oak Ridge Institute of Nuclear Studies Symposium, Nov. 1-4, 1965. Oak Ridge, TN: U.S. Atomic Energy Commission, Division of Technical Information; 1966:217.
  3. ↵
    Wellman HN, Anger RT Jr. Radioiodine dosimetry and the use of radioiodines other than I-131 in thyroid diagnosis. Semin Nucl Med 1971;1:356–378.
    OpenUrlCrossRefPubMed
  4. ↵
    Britton KE, Flofey RR, Siddiqui A, et al. I-123 imaging for the prediction of I-131 therapy for recurrent differentiated thyroid cancer when I-131 trace is negative but raised thyroglobulin [abstract]. Eur J Nucl Med 1999;26:1013.
    OpenUrl
  5. ↵
    Park HM. The stunning effect in radioiodine therapy of thyroid cancer. In: Freeman L, ed. Nuclear Medicine Annals Philadelphia, PA: Lippincott, Williams & Wilkins; 2001:49–67.
  6. ↵
    Park HM, Park YH, Zhou X. Detection of thyroid remnant/metastasis without stunning: an ongoing dilemma. Thyroid 1997;7:277–280.
    OpenUrlPubMed
  7. ↵
    Mandel SJ, Shankar LK, Yamamoto BF, Alavi A. Superiority of iodine-123 compared with iodine-131 scanning for thyroid remnants in patients with differentiated thyroid carcinoma. Clin Nucl Med 2001;26:6–9.
    OpenUrlCrossRefPubMed
  8. ↵
    Shankar LK, Yamamoto AJ, Alavi A, Mandel SJ. Comparison of 123I scintigraphy at 5 and 24 hours in patients with differentiated thyroid cancer. J Nucl Med 2002;43:72–76.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 43, Issue 1
January 1, 2002
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
123I: Almost a Designer Radioiodine for Thyroid Scanning
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
123I: Almost a Designer Radioiodine for Thyroid Scanning
Hee-Myung Park
Journal of Nuclear Medicine Jan 2002, 43 (1) 77-78;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
123I: Almost a Designer Radioiodine for Thyroid Scanning
Hee-Myung Park
Journal of Nuclear Medicine Jan 2002, 43 (1) 77-78;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Invited Commentary

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire