Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleTheranostics

Semiautomatically Quantified Tumor Volume Using 68Ga-PSMA-11 PET as a Biomarker for Survival in Patients with Advanced Prostate Cancer

Robert Seifert, Ken Herrmann, Jens Kleesiek, Michael Schäfers, Vijay Shah, Zhoubing Xu, Guillaume Chabin, Sasa Grbic, Bruce Spottiswoode and Kambiz Rahbar
Journal of Nuclear Medicine December 2020, 61 (12) 1786-1792; DOI: https://doi.org/10.2967/jnumed.120.242057
Robert Seifert
1Department of Nuclear Medicine, University Hospital Münster, Münster, Germany
2Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
3German Cancer Consortium (DKTK), Essen, Germany
4West German Cancer Center, Muenster and Essen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ken Herrmann
2Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
3German Cancer Consortium (DKTK), Essen, Germany
4West German Cancer Center, Muenster and Essen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jens Kleesiek
3German Cancer Consortium (DKTK), Essen, Germany
5Division of Radiology, German Cancer Research Center, Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Schäfers
1Department of Nuclear Medicine, University Hospital Münster, Münster, Germany
4West German Cancer Center, Muenster and Essen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vijay Shah
6Siemens Medical Solutions USA, Inc., Knoxville, Tennessee; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zhoubing Xu
7Siemens Medical Solutions USA, Inc., Princeton, New Jersey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Guillaume Chabin
7Siemens Medical Solutions USA, Inc., Princeton, New Jersey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sasa Grbic
7Siemens Medical Solutions USA, Inc., Princeton, New Jersey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bruce Spottiswoode
6Siemens Medical Solutions USA, Inc., Knoxville, Tennessee; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kambiz Rahbar
1Department of Nuclear Medicine, University Hospital Münster, Münster, Germany
4West German Cancer Center, Muenster and Essen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Prostate-specific membrane antigen (PSMA)–targeting PET imaging is becoming the reference standard for prostate cancer staging, especially in advanced disease. Yet, the implications of PSMA PET–derived whole-body tumor volume for overall survival are poorly elucidated to date. This might be because semiautomated quantification of whole-body tumor volume as a PSMA PET biomarker is an unmet clinical challenge. Therefore, in the present study we propose and evaluate a software that enables the semiautomated quantification of PSMA PET biomarkers such as whole-body tumor volume. Methods: The proposed quantification is implemented as a research prototype. PSMA-accumulating foci were automatically segmented by a percental threshold (50% of local SUVmax). Neural networks were trained to segment organs in PET/CT acquisitions (training CTs: 8,632, validation CTs: 53). Thereby, PSMA foci within organs of physiologic PSMA uptake were semiautomatically excluded from the analysis. Pretherapeutic PSMA PET/CTs of 40 consecutive patients treated with 177Lu-PSMA-617 were evaluated in this analysis. The whole-body tumor volume (PSMATV50), SUVmax, SUVmean, and other whole-body imaging biomarkers were calculated for each patient. Semiautomatically derived results were compared with manual readings in a subcohort (by 1 nuclear medicine physician). Additionally, an interobserver evaluation of the semiautomated approach was performed in a subcohort (by 2 nuclear medicine physicians). Results: Manually and semiautomatically derived PSMA metrics were highly correlated (PSMATV50: R2 = 1.000, P < 0.001; SUVmax: R2 = 0.988, P < 0.001). The interobserver agreement of the semiautomated workflow was also high (PSMATV50: R2 = 1.000, P < 0.001, interclass correlation coefficient = 1.000; SUVmax: R2 = 0.988, P < 0.001, interclass correlation coefficient = 0.997). PSMATV50 (ml) was a significant predictor of overall survival (hazard ratio: 1.004; 95% confidence interval: 1.001–1.006, P = 0.002) and remained so in a multivariate regression including other biomarkers (hazard ratio: 1.004; 95% confidence interval: 1.001–1.006 P = 0.004). Conclusion: PSMATV50 is a promising PSMA PET biomarker that is reproducible and easily quantified by the proposed semiautomated software. Moreover, PSMATV50 is a significant predictor of overall survival in patients with advanced prostate cancer who receive 177Lu-PSMA-617 therapy.

  • PSMA-PET/CT
  • prostate cancer
  • image biomarker
  • tumor volume

Prostate cancer is the most frequent cause of cancer-related death in men (1). The precise detection of prostate cancer metastases is of great importance for therapy monitoring and treatment intensification (2). Moreover, metastases are often responsible for prostate cancer–related morbidity and mortality (3,4). Thus, the quantification of the whole-body tumor volume is clinically relevant, and we conjecture that it could ultimately predict overall survival (OS) of patients.

Prostate-specific membrane antigen (PSMA)–targeting PET has emerged to become the reference standard examination for the diagnostic workup of patients with prostate cancer (5,6). PSMA is a cell surface marker of prostate cancers cells and is targeted by various ligands for both diagnostic and therapeutic approaches (7,8). However, despite their name, PSMA-ligands such as PSMA-11 show strong accumulation without pathologic implications in many organs, for example, the liver, kidneys, salivary glands, and others (9,10). Therefore, physiologic PSMA accumulations have to be discarded when quantifying image biomarkers.

Image biomarkers have been proposed for various molecular imaging modalities such as scintigraphy or PET (11,12). For example, the bone scan index can be quantified automatically using skeletal scintigraphy and has proven to predict the survival of patients with prostate cancer (13). However, skeletal scintigraphy neglects soft-tissue metastases, which are of great clinical importance. Yet, only manual or rudimentary automated approaches have been proposed for quantifying the whole-body tumor volume in PSMA PET/CT (14,15). Although several studies demonstrated that the change of PSMA PET/CT–derived tumor volume correlates with therapy response, the predictive potential is still poorly elucidated (14,16–19). Importantly, there is no clear evidence that PSMA PET–derived biomarkers can predict the survival of patients with prostate cancer. Finally, most software tools for the automated quantification of PSMA PET biomarkers use a global SUV threshold for the segmentation of prostate cancer foci (14,15). This procedure may neglect partial-volume effects that hamper a sound tumor volume quantification (20–22). Additionally, global thresholding violates the European Association of Nuclear Medicine (EANM) recommendation for molecular volume quantification, which suggests percental thresholding (e.g., 50% of maximal lesion SUV should be used for segmentation of the very same lesion) (23).

In this article, we propose and evaluate a novel semiautomated software, which quantifies the whole-body tumor volume in PSMA PET/CT. Percental thresholding is used in analogy to EANM guidelines for 18F-FDG. Moreover, a neural network is used, which semiautomatically excludes many physiologic PSMA foci from the quantification. Finally, we estimate the survival of patients with advanced prostate cancer who are receiving systemic therapy.

MATERIALS AND METHODS

Patients

To enable the automated organ segmentation, a total number of 8,685 CT scans were labeled by a team of experienced annotators mentored and reviewed by a radiologist. Data were rigorously split for training (n = 8,632) and validation (n = 53 CTs) of the neural networks dedicated to organ segmentation. All data involved in organ segmentation development were independent from the PSMA PET/CTs.

For the analysis of PSMA PET/CT biomarkers, a total number of 40 consecutive patients with metastasized castration-resistant prostate cancer were included in this study. Patients were treated with 177Lu-PSMA-617 in the department of nuclear medicine in Münster from December 2014 to December 2016. PSMA PET/CTs were acquired before the start of therapy. OS time until death or censoring was recorded. Blood parameters were obtained immediately before the administration of the first therapy. Detailed patient characteristics are summarized in Table 1. The retrospective analysis was approved by the local ethics committee (no. 2016-585-f-S, Ethikkommission der Ärztekammer Westfalen-Lippe and der Westfälischen Wilhelms-Universität Münster).

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

PET Acquisition

A Biograph mCT (Siemens Healthineers) was used for PET/CT acquisitions. The PSMA-11 precursor was provided by ABX (ABX GmbH). A GalliaPharm Gallium generator was used (Eckert & Ziegler). Intravenous administration of 68Ga-PSMA-11 was body-weight–dependent (2 MBq/kg of body weight). PET/CT images (vertex to proximal tibia) were acquired 60 min after tracer administration. Image reconstruction was done in analogy to previous publications (11). Patients were asked to void their bladder before imaging. Either low-dose or contrast-enhanced CT acquisitions were obtained directly before PET acquisition.

Semiautomated Software

A novel software was developed for the semiautomated analysis of PSMA PET/CT acquisitions to quantify the whole-body tumor volume in a 3-step approach (Fig. 1 shows the overall workflow). To this end, all pathologic PSMA-avid foci have to be delimited. This has been implemented in the research prototype software MI Whole Body Analysis Suite (MIWBAS, version 1.0; Siemens Medical Solutions USA, Inc.).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Overall workflow. (A–D) Maximum-intensity projections of 68Ga-PSMA-11 PET. Automatically selected and segmented foci are overlaid in red. Proposed software segments all PSMA foci (step 1; A), delineates organs of physiologic tracer uptake (step 2; B), and finally semi automatically excludes PSMA foci within these organs (step 3; C and D). Automated exclusion of physiologic organs removed kidneys (exemplary green arrow in B). However, bladder and a salivary gland were missed and thus manually excluded from analysis (green arrow in C). Final segmentation is shown by panel D.

Step 1: Automated PSMA Foci Segmentation

A patient-specific global threshold (thresholdPSMA) was defined to select voxel clusters with increased PSMA expression:Embedded Image

where SUVmean and SUVSD denote mean and SD of a spheric liver region of interest (ROI) (15 mm radius). This equation was adopted from the qPSMA approach of Gafita et al. (15). The liver reference ROI, which is needed to obtain SUVmean and SUVSD, was automatically positioned (24). To this end, the center of the right liver lobe was automatically determined. Manual adjustments of ROI positioning were only necessary in the case of liver metastases. We use this threshold for the entire PET acquisition to select voxel clusters (i.e., for bone foci and soft-tissue foci). A convolution of the PSMA PET with a 1-mL sphere was performed to obtain SUVpeak, which was used only for the selection of voxel clusters in analogy to PERCIST (25).

First, voxels with a SUVpeak exceeding the thresholdPSMA were selected in the whole-body PSMA PET acquisition to form voxel clusters (i.e., group of adjacent voxels). Small voxel clusters falling below a volume of 0.5 mL were discarded. Second, each voxel cluster was segmented based on the local SUVmax of the given cluster, which may enlarge or shrink the cluster size. To this end, all voxels of the cluster exceeding 50% of the local SUVmax were regarded as portions of the cluster. This procedure is done iteratively, starting with the voxel cluster with the highest SUVmax. Thereby, voxel clusters are successively transformed to candidate foci, which may resemble physiologic or pathologic PSMA accumulation (Fig. 2). The assignment of these foci to anatomic locations is described in step 2 and the removal of physiologic PSMA uptake in step 3.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Segmentation concepts. 68Ga-PSMA-11 PET/CT of patient with partly necrotic and thus low PSMA-accumulating lymph node metastases (arrows). Segmentation of PSMA foci is done by fixed global threshold alone (A) or by the consecutive application of same global threshold followed by local percental threshold (50% of SUVmax) for each focus (B). Global thresholding is erroneously selecting necrotic tumor parts as well as vital metastases. Moreover, global thresholding is producing a large confluent ROI, which includes both kidneys, a bone metastasis and parts of the liver (A). Corrections would require voxelwise manipulations. In contrast, additional application of percental thresholds (50% of SUVmax) result in multiple ROIs (indicated by separate colors), which are not confluent and exclude necrotic tumor parts (B). Moreover, physiologic uptake can easily be discarded by semiautomated deletion of ROIs in organs with physiologic uptake.

Step 2: Automated Organ Segmentation

The anatomic position of each candidate focus was automatically determined to exclude foci of organs with physiologic tracer uptake and to quantify the tumor volume with respect to certain organs. The following organs were therefore chosen for automated segmentation: liver, kidneys, bladder, heart, lungs, brain, and skeleton. The algorithm segmented these organs with a generative adversarial network (GAN) in a 3-step inference using CT data: first, a set of 126 anatomic landmarks, including vessel bifurcations, bony structures, and organ center and boundary points, was detected in the CT (26). Preliminary ROIs of each individual organ based on the detected landmarks were extracted and fed to a dedicated organ segmentation network for refinement. The preliminary ROIs were substantially smaller than the CT volume, which improved the consistency by focusing on regional variations rather than variations in the overall image and increased efficiency by reducing computational load. For the skeleton, the ROI was the entire CT volume (27). Second, a dedicated deep image-to-image network (DI2IN) was used for the final segmentation of each organ (28). It consisted of a convolutional encoder–decoder architecture combined with multilevel feature concatenation. For training, an adversarial network was selectively used to regularize the training process of DI2IN by discriminating the output of DI2IN from the ground truth in a patch-by-patch manner using binary cross-entropy. For validation, the segmentation quality was measured as a dice similarity coefficient (DSC) between the segmentation and the ground truth of the validation set in resampled resolutions, where DSC is a volumetric overlap metric between 2 mask volumes, for example, A and B:Embedded Image

Third, each organ segmentation mask was transferred to the PET data.

Step 3: Semiautomated Determination of Image Biomarkers

Candidate foci within organs with physiologic PSMA accumulation (liver, spleen, bladder, kidneys) are automatically excluded. Candidate foci within other organs with physiologic PSMA uptake such as small bowl, salivary and tear glands, ganglia, and others had to be manually discarded. If physiologic foci were erroneously missed by the software, they were manually removed. Thereby, only foci with pathologic PSMA uptake remained in the analysis (i.e., pathologic foci).

Biomarkers were calculated for soft tissue, the skeleton, and the whole patient: The volumes of segmented lesions were summed to obtain the whole-body tumor volume (PSMATV50). In analogy to total lesion glycolysis, PSMATL was quantified as product of PSMATV50 and SUVmean. Additionally, the highest SUVmax and SUVpeak as well as averaged SUVmean were quantified.

Manual PSMA PET Measurements and Interobserver Agreement

First, manual reads of PSMA PET/CTs were performed (by a reader with >2 y of clinical PET experience) using syngo.MM Oncology software (Siemens Healthineers) to quantify PSMATV50, SUVmean, SUVpeak, and SUVmax (the VOI Isocontour segmentation tool was used, involving manually identifying a spheric region in which 50% of SUVmax was used for segmentation). Second, an interobserver study was performed (by readers with >5 y PET experience) independently using the semiautomated software. A subcohort of 20 randomly selected patients was used for both purposes due to logistic reasons.

Additionally, the whole-body tumor volume was quantified without 50% percental thresholding for comparison and denoted PSMATV. To this end, manual segmentation of pathologic PSMA foci was done in the subgroup using the global thresholdPSMA. Refinement of the threshold was only done in the case of confluent lesions or other visual saliences (e.g., necrotic tumor parts that were erroneously segmented).

Statistical Analysis

SPSS 24 (IBM) was used for paired t tests, log-rank test, Cox regression, interclass correlation coefficient (ICC), Spearman ρ or Pearson correlational analysis and plotting. MATLAB R2018b (The MathWorks) and Excel 2010 (version 14.0; Microsoft) were used for data management. Values are presented as mean together with the 95% confidence interval (95% CI). Mean absolute agreement ICC was calculated using a 2-way mixed-effect model. P values less than 0.05 were regarded as statistically significant.

RESULTS

Organ Segmentation

The automatic organ segmentation demonstrated a mean DSC value of at least 0.86 for every organ. The skeleton segmentation performed accurately, with a mean DSC value over 0.92 (95% CI, 0.894–0.944). Details are given in Table 2.

View this table:
  • View inline
  • View popup
TABLE 2

Numbers of Training and Validation Data for Each Organ and DSC Over Validation Set

Manual Measurement of PSMA Biomarkers

Manual and semiautomatically quantified whole-body tumor volume did not significantly differ and showed high correlation (162.8 vs. 173.3 mL, P = 0.107; R2 = 0.996, P < 0.001). The same was true for SUVmax (58.0 vs. 53.3, P = 0.229; R2 = 0.790, P < 0.001), SUVpeak (35.1 vs. 35.6, P = 0.541; R2 = 0.964, P < 0.001), and SUVmean (16.1 vs. 15.9, P = 0.779; R2 = 0.943, P < 0.001). Statistically significant difference was observed for PSMATL between manual and semiautomated reads (2,422.2 vs. 2,649.1, P = 0.031; R2 = 0.990, P < 0.001).

PSMA PET/CT reading using the semiautomated software was on average 3.3 times faster than using the manual approach and can be accomplished in approximately 2 min (average time per patient, 119.6 vs. 397.3 s, P = 0.02, n = 10).

Interobserver Agreement of PSMA Biomarkers

Whole-body PSMATV50 was highly correlated (R2 = 1.000; P < 0.001) between reader 1 and 2 (for soft-tissue PSMATV50: R2 = 1.000, P < 0.001; for skeletal PSMATV50: R2 = 1.000, P < 0.001). The same was true for SUVmax (R2 = 0.988, P < 0.001), SUVmean (R2 = 0.953, P < 0.001), and PSMALA (R2 = 0.998, P < 0.001). ICCs of PSMATV50, PSMATL, SUVmax, and SUVmean were 1.000 (95% CI: 1.000–1.000), 1.000 (95% CI: 0.999–1.000), 0.997 (95% CI: 0.991–0.999), and 0.988 (95% CI: 0.969–0.995). Details are provided in Figure 3.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Evaluation of proposed software. Semiautomatically derived whole-body PSMATV50 is highly correlated with volume of all manually segmented lesions (A). The same is true for the whole-body PSMATL (B). Bland–Altmann plot of interobserver agreement is shown in C. Subcohort (n = 20) was used for these analyses.

PSMA Biomarkers and OS

In a first approach, univariate Cox regression was performed for PSMA biomarkers and blood tumor markers. Significant predictors of OS were PSMATV50 (hazard ratio [HR]: 1.004; P = 0.002) and alkaline phosphatase (HR: 1.001; P = 0.047). PSMATV50 measured in deciliter had an HR of 1.45. In a second approach, significant predictors were included in a multivariate analysis, in which only PSMATV50 remained a significant predictor of OS (HR: 1.004, P = 0.004; 95% CI: 1.001–1.006). Detailed results of uni- and multivariate Cox regressions are presented in Table 3 and Figure 4.

View this table:
  • View inline
  • View popup
TABLE 3

Cox Regressions of Survival and Biomarkers

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

OS stratified by whole-body tumor volume, which was measured by proposed software. All patients (n = 40) were stratified by whole-body PSMATV50 quartiles (A and B) or PSMATV quartiles (C and D).

Median OS according to PSMATV50 quartiles were (in descending order of tumor volume): 5.3, 7.9, 11.4, and 21.3 mo. There was no significant difference comparing OS of patients with regard to the PSMATV50 median (21.3 vs. 6.7 mo, P = 0.058). However, OS was significantly longer in quartile 1 of PSMATV50 than in quartile 4 (21.3 vs. 5.3 mo, P < 0.031).

PSMATV50 Versus PSMATV

Tumor volume measured as PSMATV was significantly greater than PSMATV50 (661.0 vs. 213.0 mL, P < 0.001). However, there was a correlation between PSMATV and PSMATV50 (R2 = 0.473; P < 0.001). PSMATV could not significantly predict OS (HR: 1.001, P = 0.062; 95% CI: 1.000–1.001) in univariate Cox regression. Likewise, there was no significant difference regarding OS between quartile 4 and quartile 1 of PSMATV (7 vs. 7.5 mo, P = 0.235).

PSMA Biomarkers and Blood Parameters

There were moderate correlations between whole-body PSMATV50 and blood levels of prostate-specific antigen (> = 0.553; P < 0.001) or skeletal PSMATV50 and alkaline phosphatase (> = 0.525; P = 0.001; Fig. 5).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Correlation of imaging and blood biomarkers. There was moderate correlation between whole-body PSMATV and prostate-specific antigen (PSA) levels (A). Same was true for skeletal PSMATV and alkaline phosphatase levels (B). Values were plotted after log10 transformation.

DISCUSSION

The semiautomated quantification of PSMA PET biomarkers such as the whole-body tumor volume by the proposed software was significantly faster than manual PET/CT readings and can be achieved on average in 2 min, and the correlation between manual and semiautomated reading was excellent. In contrast to previously proposed approaches, percental thresholding was used and no time-consuming refinement of image segmentation masks is needed. Moreover, the semiautomatically quantified tumor volume (PSMATV50) could significantly predict the OS of patients with advanced prostate cancer.

Imaging-derived biomarkers, such as whole-body tumor volume, are excellent predictors of survival in patients with various metastasized diseases (29,30). For prostate cancer, the quantification of the fraction of metastatically affected bones in planar bone scintigraphy could accurately stratify patients according to symptomatic progression and OS in a prospective phase III trial (30). Several approaches have been proposed to semiautomatically quantify tumor volumes in PSMA PET/CT (11,14,15,31). It was shown previously that the change of whole-body tumor volume correlated with the overall response (14,16). Yet, the relevance of PSMA PET imaging biomarkers as predictors of survival in patients with prostate cancer is poorly elucidated. The present work demonstrated that PSMATV50 is a significant predictor of survival in patients with advanced prostate cancer who undergo 177Lu-PSMA-617 therapy. An increase of 100 mL in whole-body tumor volume (PSMATV50) is associated with a 1.4-fold-higher risk of death. Interestingly, PSMATL did not significantly predict OS, thus strengthening the assumption that PSMA SUV does not predict response to systemic therapy and clarifying the need for novel PET biomarkers such as PSMATV50.

Organs of physiologic PSMA-ligand excretion have to be excluded when quantifying whole-body tumor volume or other biomarkers. To this end, various approaches have been proposed to assist the reader in removing physiologic accumulations (14,15). A GAN is used by the proposed software for automated organ segmentation. The CT component is used by the neural network to extract anatomic landmarks and segmentations, which are transferred to the PET component by rigid transformation. The DSC, which measures the accuracy segmentation, is higher for the proposed software (mean: 0.926) than for the software qPSMA (77.4–85.6) when analyzing the skeleton mask (18).

In contrast to other semiautomated software packages, the proposed software uses percental thresholding of PSMA foci: for each focus, 50% of the SUVmax is automatically used for confinement. This is in line with EANM guidelines for 18F-FDG PET, which recommend percental thresholding using 41% or 50% of the SUVmax for volumetric analyses (23). The use of percental thresholding is advantageous both in technical and in physical regard. The technical advantage of percental thresholding is that adjacent metastases are separated, and the whole-body tumor burden is dismembered in separate lesions. Thereby, each focus can automatically be assigned to an anatomic location. Foci assigned to organs with known physiologic excretion can thus be removed using heuristic rules (e.g., kidney, ureter, etc.). Moreover, the user is not requested to exclude missed physiologic foci by the manual adjustment of masks, but rather by deletion of the individual focus. Thus, the need of user interaction is reduced to a minimum, in contrast to global thresholding, which results in large confluent ROIs combining physiologic and pathologic foci (15). The physical benefit of percental thresholding is that the lesion size can be quantified accurately. In contrast, segmenting lesions by a global threshold is prone to overestimating the volume because of positron range and partial-volume effects, which induce image blur (22). Therefore, percental thresholding is a prerequisite for correct volumetric analyses.

Despite the 2-fold advantage of percental thresholding, there was a high correlation between whole-body tumor volume between PSMATV and PSMATV50. However, PSMATV50 was significantly smaller than PSMATV. Interestingly, PSMATV could not significantly predict OS, indicating that percental thresholding should be implemented in modern assisted reading software.

The present study faces some limitations. Only a relatively small number of patients were included, possibly hampering the generalizability to a larger population. Additionally, all enrolled patients received 177Lu-PSMA-617 therapy after the quantification of PSMA biomarkers. 177Lu-PSMA-617 therapy is targeting the same molecule that is visualized by PSMA PET. The survival prediction might therefore be biased. Moreover, one could argue that a decrease of the local SUVmax in response to therapy would cause PSMATV50 to paradoxically increase. However, solitary changes only of SUVmax seem unrealistic. Rather, not only SUVmax but also the uptake of the entire lesion should concordantly decrease in response to therapy in this scenario. Therefore, PSMATV50 would decrease and thus correctly assess therapy response. Yet, future studies should evaluate PSMATV50 as biomarker for therapy response.

The physiologic uptake of PSMA tracer varies; especially, 18F-PSMA-1007 has a fundamentally different physiologic uptake because of liver-dominant excretion (32). The liver reference ROI might be unsuitable to provide a patient-specific thresholdPSMA for foci selection in 18F-PSMA-1007 PET/CT acquisitions. Therefore, future studies should evaluate blood-pool activity as reference for ligand agnostic definitions of thresholdPSMA.

The metastatic extent of the cohort was heterogeneous, and confidence intervals of regression were relatively large. Additionally, liver metastasis with small tumor volume might still have heavily influenced OS, possibly distorting the relationship of tumor volume to OS. Future studies should evaluate the predictive potential of PSMATV50 in larger homogeneous patient cohorts that receive anticancer therapies distinct from 177Lu-PSMA-617.

CONCLUSION

The quantification of PSMA PET/CT biomarkers using the proposed software is feasible and achieves excellent interobserver agreement. Semiautomated PET reading is faster than manual analysis. Moreover, semiautomatically derived PSMATV50 biomarker is a significant predictor of OS in patients with advanced prostate cancer, whereas PSMATV is not. Future studies elucidating the predictive potential of PSMATV50 seem warranted.

DISCLOSURE

Kambiz Rahbar received consultant fees from ABX and Bayer Healthcare and lectureship fees from AAA, SIRTEX, AMGEN, and Janssen Cielag. Vijay Shah, Zhoubing Xu, Guillaume Chabin, Sasa Grbic, and Bruce Spottiswoode are full-time employees of Siemens Medical Solutions, USA, Inc. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

  • QUESTION: Can PSMA PET–based tumor volume be quantified by a semiautomated software and be used as a prognostic biomarker of OS?

  • PERTINENT FINDINGS: Semiautomated PET reading is feasible, has high interobserver agreement, and is faster than manual analysis. Semiautomatically derived tumor volume is a significant predictor of OS, whereas blood tumor markers are not.

  • IMPLICATIONS FOR PATIENT CARE: Semiautomatically derived tumor volume is a significant predictor of OS in patients with advanced prostate cancer.

Footnotes

  • Published online Apr. 24, 2020.

  • © 2020 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Siegel RL,
    2. Miller KD,
    3. Jemal A
    . Cancer statistics, 2017. CA Cancer J Clin. 2017;67:7–30.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Longo DL
    1. Sartor O,
    2. de Bono JS
    . Metastatic prostate cancer. Longo DL, ed. N Engl J Med. 2018;378:645-657.
    OpenUrl
  3. 3.↵
    1. Halabi S,
    2. Kelly WK,
    3. Ma H,
    4. et al
    . Meta-analysis evaluating the impact of site of metastasis on overall survival in men with castration-resistant prostate cancer. J Clin Oncol. 2016;34:1652–1659.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. DePuy V,
    2. Anstrom KJ,
    3. Castel LD,
    4. Schulman KA,
    5. Weinfurt KP,
    6. Saad F
    . Effects of skeletal morbidities on longitudinal patient-reported outcomes and survival in patients with metastatic prostate cancer. Support Care Cancer. 2007;15:869–876.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Fendler WP,
    2. Calais J,
    3. Eiber M,
    4. et al
    . Assessment of 68Ga-PSMA-11 PET accuracy in localizing recurrent prostate cancer: a prospective single-arm clinical trial. JAMA Oncol. 2019;5:856–863.
    OpenUrl
  6. 6.↵
    1. Fendler WP,
    2. Weber M,
    3. Iravani A,
    4. et al
    . Prostate-specific membrane antigen ligand positron-emission tomography in men with nonmetastatic castration-resistant prostate cancer. Clin Cancer Res. 2019;25:7448–7454.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Afshar-Oromieh A,
    2. Babich JW,
    3. Kratochwil C,
    4. et al
    . The rise of PSMA ligands for diagnosis and therapy of prostate cancer. J Nucl Med. 2016;57:79S–89S.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Rahbar K,
    2. Afshar-Oromieh A,
    3. Jadvar H,
    4. Ahmadzadehfar H
    . PSMA theranostics: current status and future directions. Mol Imaging. 2018;17:1536012118776068.
    OpenUrl
  9. 9.↵
    1. Hofman MS,
    2. Hicks RJ,
    3. Maurer T,
    4. Eiber M
    . Prostate-specific membrane antigen PET: clinical utility in prostate cancer, normal patterns, pearls, and pitfalls. Radiographics. 2018;38:200–217.
    OpenUrl
  10. 10.↵
    1. Backhaus P,
    2. Noto B,
    3. Avramovic N,
    4. et al
    . Targeting PSMA by radioligands in non-prostate disease: current status and future perspectives. Eur J Nucl Med Mol Imaging. 2018;45:860–877.
    OpenUrl
  11. 11.↵
    1. Bieth M,
    2. Krönke M,
    3. Tauber R,
    4. et al
    . Exploring new multimodal quantitative imaging indices for the assessment of osseous tumor burden in prostate cancer using 68Ga-PSMA PET/CT. J Nucl Med. 2017;58:1632–1637.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Nakajima K,
    2. Edenbrandt L,
    3. Mizokami A
    . Bone scan index: a new biomarker of bone metastasis in patients with prostate cancer. Int J Urol. 2017;24:668–673.
    OpenUrl
  13. 13.↵
    1. Smith M,
    2. De Bono J,
    3. Sternberg C,
    4. et al
    . Phase III study of cabozantinib in previously treated metastatic castration-resistant prostate cancer: COMET-1. J Clin Oncol. 2016;34:3005–3013.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Grubmüller B,
    2. Senn D,
    3. Kramer G,
    4. et al
    . Response assessment using 68Ga-PSMA ligand PET in patients undergoing 177Lu-PSMA radioligand therapy for metastatic castration-resistant prostate cancer. Eur J Nucl Med Mol Imaging. 2019;46:1063–1072.
    OpenUrl
  15. 15.↵
    1. Gafita A,
    2. Bieth M,
    3. Krönke M,
    4. et al
    . qPSMA: Semiautomatic software for whole-body tumor burden assessment in prostate cancer using 68Ga-PSMA11 PET/CT. J Nucl Med. 2019;60:1277–1283.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Grubmüller B,
    2. Rasul S,
    3. Baltzer P,
    4. et al
    . Response assessment using [68 Ga]Ga‐PSMA ligand PET in patients undergoing systemic therapy for metastatic castration‐resistant prostate cancer. Prostate. 2020;80:74–82.
  17. 17.
    1. Schmidkonz C,
    2. Cordes M,
    3. Schmidt D,
    4. et al
    . 68Ga-PSMA-11 PET/CT-derived metabolic parameters for determination of whole-body tumor burden and treatment response in prostate cancer. Eur J Nucl Med Mol Imaging. 2018;45:1862–1872.
    OpenUrl
  18. 18.↵
    1. Bieth M,
    2. Peter L,
    3. Nekolla SG,
    4. et al
    . Segmentation of skeleton and organs in whole-body CT images via iterative trilateration. IEEE Trans Med Imaging. 2017;36:2276–2286.
    OpenUrl
  19. 19.↵
    1. Schmuck S,
    2. Von Klot CA,
    3. Henkenberens C,
    4. et al
    . Initial experience with volumetric 68Ga-PSMA I&T PET/CT for assessment of whole-body tumor burden as a quantitative imaging biomarker in patients with prostate cancer. J Nucl Med. 2017;58:1962–1968.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Jentzen W,
    2. Freudenberg L,
    3. Eising EG,
    4. Heinze M,
    5. Brandau W,
    6. Bockisch A
    . Segmentation of PET volumes by iterative image thresholding. J Nucl Med. 2007;48:108–114.
    OpenUrlAbstract/FREE Full Text
  21. 21.
    1. Soret M,
    2. Bacharach SL,
    3. Buvat I
    . Partial-volume effect in PET tumor imaging. J Nucl Med. 2007;48:932–945.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Erdi YE,
    2. Mawlawi O,
    3. Larson SM,
    4. et al
    . Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer. 1997;80:2505–2509.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Boellaard R,
    2. Delgado-Bolton R,
    3. Oyen WJG,
    4. et al
    . FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015;42:328–354.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. Tao Y,
    2. Peng Z,
    3. Krishnan A,
    4. Zhou XS
    . Robust learning-based parsing and annotation of medical radiographs. IEEE Trans Med Imaging. 2011;30:338–350.
    OpenUrlPubMed
  25. 25.↵
    1. Wahl RL,
    2. Jacene H,
    3. Kasamon Y,
    4. Lodge MA
    . From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. J Nucl Med. 2009;50:122S–150S.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    1. Ghesu FC,
    2. Georgescu B,
    3. Zheng Y,
    4. et al
    . Multi-scale deep reinforcement learning for real-time 3D-landmark detection in CT scans. IEEE Trans Pattern Anal Mach Intell. 2019;41:176–189.
    OpenUrl
  27. 27.↵
    1. Lindgren Belal S,
    2. Sadik M,
    3. Kaboteh R,
    4. et al
    . Deep learning for segmentation of 49 selected bones in CT scans: first step in automated PET/CT-based 3D quantification of skeletal metastases. Eur J Radiol. 2019;113:89–95.
    OpenUrl
  28. 28.↵
    1. Yang D,
    2. Xu D,
    3. Zhou SK,
    4. et al
    . Automatic liver segmentation using an adversarial image-to-image network. arXiv.org website. https://arxiv.org/pdf/1707.08037.pdf. Accessed October 14, 2020.
  29. 29.↵
    1. Chen S,
    2. He K,
    3. Feng F,
    4. et al
    . Metabolic tumor burden on baseline 18F-FDG PET/CT improves risk stratification in pediatric patients with mature B-cell lymphoma. Eur J Nucl Med Mol Imaging. 2019;46:1830–1839.
    OpenUrl
  30. 30.↵
    1. Armstrong AJ,
    2. Anand A,
    3. Edenbrandt L,
    4. et al
    . Phase 3 assessment of the automated bone scan index as a prognostic imaging biomarker of overall survival in men with metastatic castration-resistant prostate cancer a secondary analysis of a randomized clinical trial. JAMA Oncol. 2018;4:944–951.
    OpenUrl
  31. 31.↵
    1. Hammes J,
    2. Täger P,
    3. Drzezga A.
    EBONI: A tool for automated quantification of bone metastasis load in PSMA PET/CT. J Nucl Med. 2018;59:1070–1075.
    OpenUrlAbstract/FREE Full Text
  32. 32.↵
    1. Eiber M,
    2. Herrmann K,
    3. Calais J,
    4. et al
    . Prostate cancer molecular imaging standardized evaluation (PROMISE): Proposed miTNM classification for the interpretation of PSMA-ligand PET/CT. J Nucl Med. 2018;59:469–478.
    OpenUrlAbstract/FREE Full Text
  • Received for publication January 14, 2020.
  • Accepted for publication March 25, 2020.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 61 (12)
Journal of Nuclear Medicine
Vol. 61, Issue 12
December 1, 2020
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Semiautomatically Quantified Tumor Volume Using 68Ga-PSMA-11 PET as a Biomarker for Survival in Patients with Advanced Prostate Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Semiautomatically Quantified Tumor Volume Using 68Ga-PSMA-11 PET as a Biomarker for Survival in Patients with Advanced Prostate Cancer
Robert Seifert, Ken Herrmann, Jens Kleesiek, Michael Schäfers, Vijay Shah, Zhoubing Xu, Guillaume Chabin, Sasa Grbic, Bruce Spottiswoode, Kambiz Rahbar
Journal of Nuclear Medicine Dec 2020, 61 (12) 1786-1792; DOI: 10.2967/jnumed.120.242057

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Semiautomatically Quantified Tumor Volume Using 68Ga-PSMA-11 PET as a Biomarker for Survival in Patients with Advanced Prostate Cancer
Robert Seifert, Ken Herrmann, Jens Kleesiek, Michael Schäfers, Vijay Shah, Zhoubing Xu, Guillaume Chabin, Sasa Grbic, Bruce Spottiswoode, Kambiz Rahbar
Journal of Nuclear Medicine Dec 2020, 61 (12) 1786-1792; DOI: 10.2967/jnumed.120.242057
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Evaluation of Surgical Margins with Intraoperative PSMA PET/CT and Their Prognostic Value in Radical Prostatectomy
  • Low- and High-Volume Disease in Metastatic Hormone-Sensitive Prostate Cancer: From CHAARTED to PSMA PET--An International Multicenter Retrospective Study
  • Quantitative Perfusion Imaging with Total-Body PET
  • Prognostic Value of End-of-Treatment PSMA PET/CT in Patients Treated with 177Lu-PSMA Radioligand Therapy: A Retrospective, Single-Center Analysis
  • Analysing the tumor transcriptome of prostate cancer to predict efficacy of Lu-PSMA therapy
  • A Single-Arm, Low-Dose, Prospective Study of 177Lu-EB-PSMA Radioligand Therapy in Patients with Metastatic Castration-Resistant Prostate Cancer
  • Prognostic Value of Tumor Volume Assessment on PSMA PET After 177Lu-PSMA Radioligand Therapy Evaluated by PSMA PET/CT Consensus Statement and RECIP 1.0
  • Using 68Ga-PSMA-11 PET/CT for Therapy Response Assessment in Patients with Metastatic Castration-Resistant Prostate Cancer: Application of EAU/EANM Recommendations in Clinical Practice
  • Novel Framework for Treatment Response Evaluation Using PSMA PET/CT in Patients with Metastatic Castration-Resistant Prostate Cancer (RECIP 1.0): An International Multicenter Study
  • Repeatability of 68Ga-PSMA-HBED-CC PET/CT-Derived Total Molecular Tumor Volume
  • 177Lu-PSMA-617 and Idronoxil in Men with End-Stage Metastatic Castration-Resistant Prostate Cancer (LuPIN): Patient Outcomes and Predictors of Treatment Response in a Phase I/II Trial
  • Assessing Response to 177Lu-PSMA Radioligand Therapy Using Modified PSMA PET Progression Criteria
  • Semiautomatic Tumor Delineation for Evaluation of 64Cu-DOTATATE PET/CT in Patients with Neuroendocrine Neoplasms: Prognostication Based on Lowest Lesion Uptake and Total Tumor Volume
  • Google Scholar

More in this TOC Section

Theranostics

  • Determination of the Intralesional Distribution of Theranostic 124I-Omburtamab Convection-Enhanced Delivery in Treatment of Diffuse Intrinsic Pontine Glioma
  • Evidence-Based Clinical Protocols to Monitor Efficacy of [177Lu]Lu-PSMA Radiopharmaceutical Therapy in Metastatic Castration-Resistant Prostate Cancer Using Real-World Data
  • 177Lu-Labeled Anticlaudin 6 Monoclonal Antibody for Targeted Therapy in Esophageal Cancer
Show more Theranostics

Clinical

  • TauIQ: A Canonical Image Based Algorithm to Quantify Tau PET Scans
  • Dual PET Imaging in Bronchial Neuroendocrine Neoplasms: The NETPET Score as a Prognostic Biomarker
  • Addition of 131I-MIBG to PRRT (90Y-DOTATOC) for Personalized Treatment of Selected Patients with Neuroendocrine Tumors
Show more Clinical

Similar Articles

Keywords

  • PSMA-PET/CT
  • prostate cancer
  • image biomarker
  • tumor volume
SNMMI

© 2025 SNMMI

Powered by HighWire