|
|
||||||||
Basic Science Investigations |
Departments of Pediatrics, Radiology, Epidemiology, and Biostatistics, University of California, San Francisco, San Francisco, California
| ABSTRACT |
|---|
|
|
|---|
Key Words: neuroblastoma MIBG dosimetry 131I
| INTRODUCTION |
|---|
|
|
|---|
Although multiple attempts have been made to quantify tumor and total-body uptake using the standard conjugate planar imaging method (12), the range of radiation doses delivered to the tumor has varied widely and often has been disappointing when compared with the whole-body radiation dose (1316). Few reports of dosimetry include correlation of tumor-delivered dose with tumor volume decrease after therapy or correlation of whole-body radiation dose with hematologic toxicity. We report the results of dosimetry calculations based on measurements of whole-body, blood, and tumor activity with correlation with activity administered per kilogram, hematologic toxicity, and tumor volume decrease in patients treated with 131I-MIBG in a phase I and phase II study for refractory disease.
| MATERIALS AND METHODS |
|---|
|
|
|---|
444 MBq/kg (
12 mCi/kg), patients were required to have autologous tumor-free, cryopreserved hematopoietic stem cells available before treatment. Patient characteristics are shown in Table 1. Response and toxicity data on 30 of the 42 patients have been reported with the phase I study (8), but preliminary dosimetry data have been presented for only 5 of the 42 patients included in this study (17). Informed consent was obtained from all patients or the parent or guardian, as appropriate. This study was approved by the University of California Committee on Human Research.
|
The patient was placed on a cardiac and blood pressure monitor for the actual administration. The 131I-MIBG was infused over 2 h through a dedicated syringe pump. The prescribed activity ranged from 111 to 666 MBq (318 mCi) per kilogram for those patients who were part of a phase I 131I-MIBG activity escalation study or part of an ongoing phase II study at 666 MBq/kg (8). In a few cases, the actual received activity varied from the prescribed activity because of variations in yield. Each patient was kept behind a lead shield until the exposure measurement 1 m from the patients surface was <2 mR/h (1 R = 2.58 x 10-4 C/kg). Appropriate radiation safety measures were taken to comply with state and federal guidelines regarding monitoring, waste handling, and personnel exposure.
Evaluation of Response and Toxicity
Disease evaluation to assess response was done 46 wk after treatment and every 3 mo thereafter. Disease evaluation included physical examination, 99mTc-methylene diphosphonate bone scan, 123I- or 131I-MIBG scan, CT or MRI of gross disease, bone marrow aspirate and biopsy, and measurement of urinary catecholamine metabolites. Precise volumetric measurements were made of an index lesion to monitor quantitative response to 131I-MIBG. Lesions that required palliative external beam radiation were not used in the criteria for response. Complete response denotes no detectable disease by these modalities; partial response indicates a decrease by
50% in soft-tissue lesions measured by planimetry from a CT or MR scan and a decrease in nonmeasurable lesions evaluable only by bone scan or MIBG; stable disease indicates no new lesions and no progression in size of a previous lesion by
25% for at least 3 mo after therapy; and progressive disease indicates the development of new lesions or increase by >25% in the size of any lesion. Toxicity was monitored by physical examination, complete blood counts, and liver and renal function testing weekly to 4 wk, and then monthly. Endocrine assessment of thyroid and adrenal function was done before treatment, at day 28, then every 3 mo to 1 y, and then yearly. Cardiac function was assessed by echocardiography or multigated radionuclide angiography before and 1 mo after treatment.
Dosimetry Calculations
The best evaluable tumor (target) lesion was selected on the basis of having detectable 131I-MIBG uptake and measurable tumor mass. The 131I-MIBG uptake of the target lesion was measured using conjugate-view planar imaging. More specifically, the scintillation camera was fitted with a high-energy collimator and was peaked for planar imaging of 131I. A point source consisting of a syringe with a known activity of 131I was prepared as a calibration source. An anterior planar image of the target lesion and surrounding region was acquired without the point source. The point source was then positioned adjacent to the target lesion, or on the contralateral side, in a position determined visually by a nuclear medicine physician to provide roughly equal attenuation as in the location of the target lesion. The camera was positioned to acquire a posterior planar image of the target lesion and calibration source. The calibration source then was removed to acquire a posterior planar image of the target lesion alone. This produced 4 images: anterior image of the target lesion, anterior image of the target lesion and calibration source, posterior image of the target lesion and calibration source, and posterior image of the target lesion alone.
The image data were processed by placing regions of interest (ROIs) around the target lesion in the anterior and posterior images of the target lesion alone. Background ROIs also are defined adjacent to the target lesion (12) or in a region corresponding to the location of the target lesion on the contralateral side. These values then are used to calculate the geometric mean of background-corrected counts, Ct, from the anterior (Ct,a) and posterior (Ct,p) measurements of the target lesion:
![]() | (Eq. 1) |
![]() | (Eq. 2) |
![]() | (Eq. 3) |
Tumor mass for the index lesion was measured using planimetry from CT or MR scans. The tumor activity measurement described above was performed 2 or 3 times from day 3 to day 7 after treatment and expressed in units of megabecquerels. The tumor activity values then were fit to a single exponential, with tumor dose calculated using the Society of Nuclear Medicines MIRD schema (18). S values for self-absorption (i.e., when the target organ is the source organ) for the tumor were calculated from a powerfunction relationship,
![]() | (Eq. 4) |
The whole-body radiation dose was calculated by 2 methods. The first method assumed that the total activity in the whole body is proportional to measurements of radiation exposure rate obtained with an ionization chamber, held in fixed geometry at 1 m from the patients body surface. In the second method, the whole-body dose was calculated from urine extraction as described below.
The whole-body exposure rate was measured at 1 h after infusion and approximately daily thereafter for 7 d. Five or more data points were obtained for most patients, allowing a double-exponential curve to be fit to the whole-body timeexposure curve. However, when <4 exposure data points were available, the data were fit to a single-exponential curve. In the case of a double-exponential, a timeactivity curve having the form
![]() | (Eq. 5) |
1,
2) and the coefficients (C1, C2). The coefficients and time constants then were used to obtain the cumulated activity Ã:
![]() | (Eq. 6) |
![]() | (Eq. 7) |
Similarly, the radiation dose to bone marrow was calculated by multiplying the cumulated activity for the whole body by the S factor for 131I, assuming that wb is the source organ and that bone marrow (bm) is the target organ:
![]() | (Eq. 8) |
The radiation dose Dbl to blood was calculated (21) as the radiation dose to blood attributed to ß-particles emitted by radioactivity in the blood (ß-component, Dbl,ß) added to the radiation dose attributed to
-radiation arising from radioactivity in the whole body (
-component, Dbl,
):
![]() | (Eq. 9) |
![]() | (Eq. 10) |
ß(131I) = 1.104 x 10-4 kg-Gy/MBq/h is the mean energy emitted per unit transition contributed by ß-particles from 131I.
Similarly, the
-component was calculated as:
![]() | (Eq. 11) |

(131I) = 2.175 x 10-4 kg-Gy/MBq/h is the mean energy emitted per unit transition contributed by
-rays from 131I. We note that the values for the mean energy emitted per unit transition were obtained from MIRD Pamphlet 10 (22) and are similar to values published more recently by Weber et al. (23). In addition, the fraction of the
-radiation from the whole body that was absorbed by the blood was assigned a value of
= 0.4, following Benua et al. (21), with the same value of
used for patients of all ages and sizes. The whole-body radiation dose measurements were verified by actual comparison with the total activity remaining using the cumulated activity excreted in the urine. For the first 14 treatments, we measured the activity excreted in urine immediately after injection, and at 12, 24, 48, 72, 96, 120, and 148 h after injection, and corrected for physical decay. At each time point, the cumulated (decay corrected) activity excreted in urine was subtracted from the total injected activity to give the total activity remaining in the whole body without physical decay. These values were multiplied by the appropriate factor to account for physical decay, giving the total whole-body activity remaining in the body, including physical decay. Linear regression analysis of the whole-body dose measurements calculated from urine extraction and from whole-body exposure measurements (Fig. 1) produced a correlation coefficient of r = 0.726 (n = 14), corresponding to a significance of P < 0.005 (24), which indicated a close correlation between the results from these 2 methods.
|
| RESULTS |
|---|
|
|
|---|
555 MBq/kg (15 mCi/kg) manifested grade 34 hematologic toxicity compared with only approximately 50% of those treated at lower doses, as reported in our phase I study (8). Eleven of the patients met criteria for autologous hematopoietic stem cell support after MIBG therapy, including 9 of 17 treated at 666 MBq/kg and 2 of 7 treated at 555 MBq/kg.
Whole-Body, Blood, and Red Marrow Dose
The median and range for the administered total activity and the activity per kilogram, whole-body radiation dose, blood dose, red marrow dose, tumor dose (TSARD), and tumor volume change are summarized for all evaluable patients in Table 2. The median whole-body dose for patients by level increased progressively with a median dose of 124 cGy at 222 MBq/kg, 159 cGy at 333 MBq/kg, 212 cGy at 444 MBq/kg, and 323 cGy at 555 MBq/kg. The median whole-body dose at 666 MBq/kg was 294 cGy, with more overlap between 555 MBq/kg and 666 MBq/kg (Fig. 2), perhaps associated with the greater variability at this level or the increased number of patients. The Spearman correlation between administered activity per kilogram and whole-body dose received was significant, as shown in Figure 2 (rs = 0.59; P < 0.0001). The total activity per kilogram administered also correlated with the whole-body radiation dose (rs = 0.54; P < 0.0001). No significant correlation was found between the activity administered per kilogram and the blood dose (rs = 0.18; P = 0.4), probably because of the very rapid clearance of MIBG from the blood (26). The red marrow dose correlated closely with the activity per kilogram (rs = 0.82; P < 0.0001), as expected because this is calculated using body weight.
|
|
555 MBq/kg of 131I-MIBG activity requiring stem cell infusion compared with 0 of 18 patients who received <555 MBq/kg (P < 0.001). The median whole-body dose in the 11 patients who required hematopoietic stem cell support for neutropenia was 323 cGy (range, 181650 cGy) compared with 217 cGy (range, 57540 cGy) for the 31 patients who did not require stem cell infusion (P = 0.03).
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Ideally, the whole-body dose should correlate accurately with the activity per kilogram. The accuracy of the method of measurement used measuring whole-body retention, also used widely in other studies (13,27), was verified in our study with quantitative urinary excretion of radionuclide. A significant correlation was found between of the whole-body radiation dose and the activity administered per kilogram of body weight. However, there was also interpatient variability, probably attributed, in part, to differing rates of renal excretion (28) and different amounts of body tumor burden and tumor retention. Ways to possibly decrease sources of error include the measurement with a fixed counter rather than a handheld Geiger counter and increasing the number of readings taken per day (29). Pretherapy dosimetry might improve the prediction of total-body dose compared with administering activity based on weight, as has been suggested by others (30). However, it is more tedious, requiring a 5-d pretreatment scan with at least 4 daily measurements, and still gives significant variability from the posttherapeutic measurements of whole-body dose (27,30). Fielding et al. (29,30) compared the possible error, based on whole-body measurements after treatment, with the activity that would have been prescribed on the basis of either pretherapy dosimetry or body weight. They found that prescribing activity on the basis of body weight would have resulted in the desired whole-body radiation dose (±5%) in 6 patients, too little in 8 patients, and too much in 12 patients, including 5 who would have received an overdose of >40%. Using the pretherapy dosimetry, 8 would have received within 5% of the predicted dose, whereas 17 would have been underdosed, and 1 would have been overdosed by 40% (30). In our study, assuming a direct linear relation between activity per kilogram and the whole-body dose received, using the activity prescribed on the basis of body weight resulted in the predicted whole-body dose in 11 patients (±10%), a lower whole-body dose in 18 patients, and a higher-than-expected whole-body dose in 13 patients, including 5 who received a whole-body dose >40% higher than expected and 6 who received a whole-body dose >40% lower than expected. Given that hematopoietic stem cell infusion has been shown to be effective in the reversal of hematologic toxicity, the increased whole-body radiation dose given in these instances was not serious (no patient received >650 cGy) and may have resulted in greater doses delivered to the tumors because significant correlation was shown between the whole-body dose and the TSARD and between the activity per kilogram and the tumor volume decrease.
We have presented detailed correlation for 42 patients, examining the relationships of activity, activity per kilogram, and whole-body dose to blood, red marrow doses, and myelosuppression, reflected by neutrophil nadir, platelet nadir, and the necessity for hematopoietic stem cell support, using the criterion of an absolute neutrophil count of <200 for >2 wk. The data show that activity administered per kilogram of body weight or the measured whole-body radiation dose correlates significantly with neutrophil nadir and platelet nadir, whereas the total administered activity does not. The blood dose did correlate with the whole-body dose but not with the activity per kilogram, probably because of the proven rapid clearance of activity from the blood, as shown by our data and that of others (17,27,29). Prior studies with smaller numbers of patients have also found some correlation of whole-body dose or activity administered with thrombocytopenia, but they have not explored the relationships over such a broad activity level or tested the correlation with required stem cell support (6,27). We have shown that there is a significant relationship of the activity per kilogram and the whole-body radiation dose to the necessity for stem cell support, with 11 of 24 patients who received
555 MBq/kg of 131I-MIBG activity requiring stem cell infusion compared with 0 of 18 patients who received <555 MBq/kg (P < 0.001). The median whole-body radiation dose for the 11 patients who required hematopoietic stem cell support for neutropenia was also significantly higher (323 cGy compared with 217 cGy) than that of the 31 patients who did not require hematopoietic stem cell infusion (P = 0.03). Thus, either activity administered per kilogram or estimates of whole-body dose may be used to predict myelosuppression and the likelihood of prolonged neutropenia requiring stem cell support after 131I-MIBG therapy. Further investigations correlating the effect of tumor burden and the glomerular filtration rate (28) on whole-body dose may be useful.
We have shown with data from a large number of patients that tumor dosimetry is valuable for predicting the volume decrease of the index tumor lesion and the overall disease response. Previous reports of small numbers of children with neuroblastoma found a wide variability in tumor dose delivered and did not express this in relation to activity administered per body weight. This confounded the results for small children compared with larger children or adults, because treatment in most previous studies was at a standard total activity level or whole-body radiation dose (14,29). Previous reports also did not try to verify their calculations by comparisons with disease response or target lesion shrinkage. We found that the volume decrease correlated with the TSARD, thus validating the use of dosimetry despite the variability. Future protocols may further increase the radiation delivered to the tumor by administering 2 successive infusions of 131I-MIBG with stem cell support to deliver a larger amount of activity in a short time period. Another approach is to find means to enhance MIBG uptake or retention. For example, cisplatin or doxorubicin has been shown to enhance MIBG uptake by neuroblastoma in vitro (31,32) as has increasing expression of the noradrenaline transporter gene, known to be crucial to MIBG uptake (33). Other approaches are to enhance the potency of the radiolabeled MIBG itself, either using no-carrier-added product (34) or using different isotopes with the MIBG, such as 125I (35,36) or the
-emitter 211At (37).
The value of tumor dosimetry has been diminished in the past because of the many sources of error inherent in the conjugate planar method. These include the estimates involved in inhomogeneous uptake within the tumor and difficulties in accurately assessing the tumor volume on CT or MR scans. Although the conjugate-view method uses a calibrated point source to calibrate the data for collimator and detector efficiency, photon attenuation, and scatter radiation, the calibration is obtained at only 1 point and, therefore, does not account for regional variations in the patient. These effects can lead to false-negative interpretations for small lesions or in large patients. Newer techniques of dosimetry that are now under investigation may eliminate some of these problems by fusing the structural CT or MR images with the functional nuclear images to obtain 3-dimensional dosimetry (38,39). Similarly, the development of imaging techniques that combine SPECT with CT, or PET with CT, may improve quantitation of targeted radiodiagnostic and radiotherapeutic agents in comparison with methods performed with conventional imaging techniques (40).
| CONCLUSION |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
For correspondence or reprints contact: Katherine K. Matthay, MD, Department of Pediatrics, Box 0106, University of California School of Medicine, San Francisco, San Francisco, CA 94143-0106.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
G. Khanna, D. Bushnell, and M. S. O'Dorisio Utility of Radiolabeled Somatostatin Receptor Analogues for Staging/Restaging and Treatment of Somatostatin Receptor-Positive Pediatric Tumors Oncologist, April 1, 2008; 13(4): 382 - 389. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J. G. Oyen, L. Bodei, F. Giammarile, H. R. Maecke, J. Tennvall, M. Luster, and B. Brans Targeted therapy in nuclear medicine current status and future prospects Ann. Onc., November 1, 2007; 18(11): 1782 - 1792. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Mairs, S. C. Ross, A. G. McCluskey, and M. Boyd A Transfectant Mosaic Xenograft Model for Evaluation of Targeted Radiotherapy in Combination with Gene Therapy In Vivo J. Nucl. Med., September 1, 2007; 48(9): 1519 - 1526. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. K. Matthay, G. Yanik, J. Messina, A. Quach, J. Huberty, S.-C. Cheng, J. Veatch, R. Goldsby, P. Brophy, L. S. Kersun, et al. Phase II Study on the Effect of Disease Sites, Age, and Prior Therapy on Response to Iodine-131-Metaiodobenzylguanidine Therapy in Refractory Neuroblastoma J. Clin. Oncol., March 20, 2007; 25(9): 1054 - 1060. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. K. Kontogeorgakos, P. A. Dimitriou, G. S. Limouris, and L. J. Vlahos Patient-Specific Dosimetry Calculations Using Mathematic Models of Different Anatomic Sizes During Therapy with 111In-DTPA-D-Phe1-Octreotide Infusions After Catheterization of the Hepatic Artery J. Nucl. Med., September 1, 2006; 47(9): 1476 - 1482. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Madsen, D. L. Bushnell, M. E. Juweid, Y. Menda, M. S. O'Dorisio, T. O'Dorisio, and I. M. Besse Potential Increased Tumor-Dose Delivery with Combined 131I-MIBG and 90Y-DOTATOC Treatment in Neuroendocrine Tumors: A Theoretic Model J. Nucl. Med., April 1, 2006; 47(4): 660 - 667. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. K. Matthay, J. C. Tan, J. G. Villablanca, G. A. Yanik, J. Veatch, B. Franc, E. Twomey, B. Horn, C. P. Reynolds, S. Groshen, et al. Phase I Dose Escalation of Iodine-131-Metaiodobenzylguanidine With Myeloablative Chemotherapy and Autologous Stem-Cell Transplantation in Refractory Neuroblastoma: A New Approaches to Neuroblastoma Therapy Consortium Study J. Clin. Oncol., January 20, 2006; 24(3): 500 - 506. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. DuBois, J. Messina, J. M. Maris, J. Huberty, D. V. Glidden, J. Veatch, M. Charron, R. Hawkins, and K. K. Matthay Hematologic Toxicity of High-Dose Iodine-131-Metaiodobenzylguanidine Therapy for Advanced Neuroblastoma J. Clin. Oncol., June 15, 2004; 22(12): 2452 - 2460. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. F. Koral, Y. Dewaraja, J. Li, Q. Lin, D. D. Regan, K. R. Zasadny, S. G. Rommelfanger, I. R. Francis, M. S. Kaminski, and R. L. Wahl Update on Hybrid Conjugate-View SPECT Tumor Dosimetry and Response in 131I-Tositumomab Therapy of Previously Untreated Lymphoma Patients J. Nucl. Med., March 1, 2003; 44(3): 457 - 464. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Siegel, M. G. Stabin, R. B. Sparks, J. Huberty, K. K. Matthay, R. Hawkins, and B. Hasegawa Total-Body and Red Marrow Dose Estimates J. Nucl. Med., February 1, 2003; 44(2): 320 - 323. [Full Text] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |