Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportNeurosciences

Can incorporation of a quantitative estimate of cortical to cerebellar SUVr as an adjunct to visual interpretation improve the accuracy and reliability of florbetapir PET scan interpretation?

Michael Pontecorvo, Michael Devous, Anupa Arora, Marybeth Devine, Ming Lu, Abhinay Joshi, Christopher Breault, Daniel Skovronsky, Mark Mintun and Stephen Heun
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 245;
Michael Pontecorvo
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Devous
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anupa Arora
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marybeth Devine
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ming Lu
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Abhinay Joshi
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christopher Breault
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel Skovronsky
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mark Mintun
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephen Heun
1Avid Radiopharmaceuticals, Inc., Philadelphia, PA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

245

Objectives We evaluated whether quantitation by FDA-cleared software as an adjunct to visual interpretation (VisQ method) improves accuracy of florbetapir scan interpretation in lower accuracy readers (<90% accuracy using visual techniques alone).

Methods 22 physicians were trained to quantitateflorbetapir images as an adjunct to visual interpretation. Each reader then visually interpreted, without access to quantitation information, 46 florbetapir PET images from subjects autopsied within one year of PET scan and 50 images from patients seeking diagnosis for cognitive decline. Next, the readers reviewed all 96 images again, using a software package to calculate a quantitative estimate (SUVr) of florbetapir activity and applied the VisQ method. For each case, the reader compared the SUVr to normal ranges. For scans in which the initial visual read and quantitative result were discordant, readers reassessed their original interpretation in light of the quantitation, reinspected images and verified ROI placement (a potential source of error in SUVr calculation) to resolve any discordance. They then provided a final VisQ interpretation.

Results With visual interpretation, the mean accuracy (compared to pathology truth standard) on the 46 autopsy verified cases was 89.5%. 7 of the 22 readers were identified as lower accuracy (< 90%) from the visual reads. In these 7 readers, accuracy improved significantly with VisQ from a mean of 81.7% to 88.8% (p=0.0029). Across all 22 readers, accuracy improved from 89.5% to 93.8% (p<0.0001). Interreader agreement across all 96 cases increased (p < 0.05) from a Fleiss kappa of 0.72 to 0.79.

Conclusions Accuracy and interreader reliability significantly increased after applying the VisQ method that incorporates quantitative estimates of florbetapir PET amyloid binding (SUVr). To test the generality of these findings studies are ongoing with additional software packages.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 55, Issue supplement 1
May 2014
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Can incorporation of a quantitative estimate of cortical to cerebellar SUVr as an adjunct to visual interpretation improve the accuracy and reliability of florbetapir PET scan interpretation?
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Can incorporation of a quantitative estimate of cortical to cerebellar SUVr as an adjunct to visual interpretation improve the accuracy and reliability of florbetapir PET scan interpretation?
Michael Pontecorvo, Michael Devous, Anupa Arora, Marybeth Devine, Ming Lu, Abhinay Joshi, Christopher Breault, Daniel Skovronsky, Mark Mintun, Stephen Heun
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 245;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Can incorporation of a quantitative estimate of cortical to cerebellar SUVr as an adjunct to visual interpretation improve the accuracy and reliability of florbetapir PET scan interpretation?
Michael Pontecorvo, Michael Devous, Anupa Arora, Marybeth Devine, Ming Lu, Abhinay Joshi, Christopher Breault, Daniel Skovronsky, Mark Mintun, Stephen Heun
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 245;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Neurosciences

  • PET CT Quantification to direct Alzheimer’s patients to anti-amyloid therapy
  • Multicenter trial study for usefulness of physical parameters toward the standardization of brain SPECT image: relation to visual analysis
  • Assessment of Brain Perfusion 123I-IMP SPECT imaging Using Low Energy High Resolution Collimator image reconstructed by Flash 3D
Show more Neurosciences

AD II: Advanced Approaches

  • A negative florbetaben PET scan reliably excludes AD pathology as confirmed by histopathology
  • Effect of pre-processing on diagnostic performance of FDG PET using machine-learning for the detection of Alzheimer's disease: The Ishikawa Brain Imaging Study
Show more AD II: Advanced Approaches

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire