Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherDEPARTMENTS

External and Internal Dose to Individuals After 131I Outpatient Therapy

Wesley W. Wooten
Journal of Nuclear Medicine April 2002, 43 (4) 575;
Wesley W. Wooten
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR:

I would like to comment on the article by Coover et al. (1) on a simplified method to comply with federal regulations 10CFR35.75 during outpatient treatment with 131I. The method presented in this paper closely follows the method described in Nuclear Regulatory Commission Regulatory Guide 8.39 (2). Unfortunately, 8.39 has been misconstrued by Coover et al. and by other authors, leading to inappropriate neglect of internal dose when performing calculations to comply with 10CFR35.75. Coover et al. state, “…studies show that those exposed to patients receiving 131I therapy incur relatively little internal radiation contamination and that it may be overlooked. …” To support this statement, Coover et al. cite Regulatory Guide 8.39; however, 8.39 does not support the neglect of internal dose in thyroid cancer patients.

Appendix B to 8.39 outlines procedures for calculating doses based on patient-specific factors and presents 4 sample calculations. Examples 1 through 3 are sample calculations of external dose, and Example 4 is a sample calculation of internal dose. At the end of the sample calculation in Example 4, Regulatory Guide 8.39 says, “Internal doses may be ignored in the calculations if they are likely to be less than 10 percent of the external dose… .” This sentence has been widely misconstrued to mean that internal doses may be ignored in calculations; but in the case of thyroid cancer patients, internal doses are not usually less than 10% of the external dose, and should not usually be ignored. To illustrate this point, Example 2 in Appendix B calculates the external dose to individuals exposed to a patient who is postthyroidectomy and has been treated with 200 mCi 131I. With the standard assumptions for uptake, clearance, and occupancy factors, the external dose to individuals calculated in Example 2 is 0.453 rem. Using the method of Example 4 to calculate the internal dose to individuals exposed to this patient, with the standard assumptions for ingested fraction and Dose Conversion Factor, the result is 0.106 rem internal dose. For standard postthyroidectomy conditions, and using the methods presented in Regulatory Guide 8.39, the internal dose is not less than 10% of the external dose, and should not be ignored.

The calculated values for external and internal doses to individuals have large uncertainties and depend on patient behavior, which is difficult to control or predict. However, using the methods and assumptions presented in Regulatory Guide 8.39 for individuals exposed to thyroid cancer patients, the internal dose is not always less than 10% of the external dose, and cannot be automatically ignored. In these patients, the internal dose should be calculated and added to the external dose, and the total should be compared to the 5 mSv limit. This is not a burdensome task, because the calculation of internal dose by the method of 8.39 is far simpler than the calculation of external dose. Furthermore, the result of the internal dose calculation is expressed as Effective Dose Equivalent, which can be simply added to the external dose (3). In practice, the inclusion of the internal dose offers another advantage. If there will be children exposed to the patient, the dose conversion factor for children increases as the age of the child decreases (4). This provides a rational method to partially estimate an increased risk to children who may be exposed to the patient.

It could be argued that both the internal and external dose calculations, as presented in Regulatory Guide 8.39, are overly conservative. If, however, the methods and assumptions presented in Regulatory Guide 8.39 are not challenged, then we are obliged to include internal dose as well as external dose in calculations to comply with 10CFR35.75 for thyroid cancer patients.

REFERENCES

  1. ↵
    Coover LR, Silberstein EB, Kuhn PJ, Graves MW. Therapeutic 131I in outpatients: a simplified method conforming to the Code of Federal Regulations, Title 10, Part 35.75. J Nucl Med 2000;41:1868–1875.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Nuclear Regulatory Commission. U.S. Nuclear Regulatory Commission Regulatory Guide 8.39: Release of Patients Administered Radioactive Materials Washington, DC: Office of Nuclear Regulatory Research; 1997.
  3. ↵
    National Council on Radiation Protection and Measurements. NCRP Report No. 116, Limitation of Exposure to Ionizing Radiation Bethesda, MD: National Council on Radiation Protection; 1993.
  4. ↵
    International Commission on Radiological Protection. ICRP Publication 53: Radiation Dose To Patients from Radiopharmaceuticals Tarrytown, NY: Pergamon Press; 1988.

REPLY:

The authors appreciate the comments of Dr. Wooten, as they allow us to elucidate some important facts. In our model, relative exposure is being considered. The exposure Wooten refers to in Example 4 of the Regulatory Guide is the absolute exposure secondary to 131I that has been excreted by the patient and then internalized by the exposed individual. Example 4 arbitrarily multiplies the calculated internal dose to the exposed individual by a factor of 10. This serves to exemplify a conservative estimate of the maximum absolute dose the exposed individual would reasonably be expected to receive secondary to internal exposure.

When considering the relative contribution of internal dose, multiplying the contribution from internal dose by a factor of 10 is no more appropriate than multiplying the contribution from external exposure by a factor of 10. For example, if external exposure secondary to a patient treated with 30 mCi 131I for toxic multinodular goiter were arbitrarily multiplied by a factor of 10, patient hospitalization would be mandated in most cases.

Additionally, for perspective, even if we did accept the exaggerated hypothetical model used in Example 4 (which we do not), the internal dose suggested by Wooten is less than the background radiation received by most Americans in less than 4 months.

Minimizing the internal dose to others through patient education is very important. Discussing appropriate radiation safety measures with the patient should always be performed before dose administration.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 43 (4)
Journal of Nuclear Medicine
Vol. 43, Issue 4
April 1, 2002
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
External and Internal Dose to Individuals After 131I Outpatient Therapy
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
External and Internal Dose to Individuals After 131I Outpatient Therapy
Wesley W. Wooten
Journal of Nuclear Medicine Apr 2002, 43 (4) 575;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
External and Internal Dose to Individuals After 131I Outpatient Therapy
Wesley W. Wooten
Journal of Nuclear Medicine Apr 2002, 43 (4) 575;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Recruitment
  • Recruitment
  • Recruitment
Show more Authors of the Letter and the Reply

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire