Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation

High Resolution TOF-DOI Prism-PET Brain Scanner: Experimental Results From The First Prototype Scanner

Xinjie Zeng, Zipai Wang, Wanbin Tan, Xinjie Cao, Anthony Boccia, Dinko Franceschi, Anat Biegon, Wei Zhao and Amirhossein Goldan
Journal of Nuclear Medicine August 2022, 63 (supplement 2) 2516;
Xinjie Zeng
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zipai Wang
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wanbin Tan
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Xinjie Cao
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anthony Boccia
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dinko Franceschi
2Stony Brook University Hospital
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anat Biegon
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wei Zhao
1Stony Brook University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amirhossein Goldan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

2516

Introduction: We have developed a one-ring positron emission tomography (PET) prototype scanner for human brain imaging based on our unique single-ended readout Prism-PET depth-encoding detector modules. The prototype has a decagon geometry conforming to the human head, leading to a cost-effective and high-sensitive scanner because of the limited number of detectors and larger solid angle coverage. The parallax error (PE) associated with the conformal geometry can be overcome by the 2.57 mm full width at half maximum (FWHM) depth-of-interaction (DOI) resolution of Prism-PET detectors.

Methods: The one-ring prototype has a long diameter of 38.5 cm, a short diameter of 29.1 cm, and an axial field-of-view (FOV) of 25.5 mm (Figure 1a). It consists of 40 DOI Prism-PET detector modules, each with an array of 16 x 16 lutetium yttrium oxyorthosillicate (LYSO) scintillator crystals. Each crystal size is 1.5 x 1.5 x 20 mm3 and the pitch is 1.6 mm. The crystal array is coupled 4-to-1 to an 8 x 8 readout array of 3.0 x 3.0 mm2 silicon photomultipliers (SiPM) pixels (Hamamatsu, Japan) on one side and a segmented prismatoid light guide array on the opposite side. The configuration and performance of the prototype are summarized in Figure 1b. The spatial resolution and image quality were qualitatively evaluated by an ultra-micro hot spot phantom and a 3D Hoffman brain phantom (Data Spectrum Corporation, USA). The ultra-micro hot spot phantom with different rod diameters arranged in 6 segments (0.75, 1.0, 1.35, 1.7, 2.0, and 2.4 mm) was filled with 37 MBq (1 mCi) of F-18 at the start and scanned for 60 min. The Hoffman brain phantom was also filled with 37 MBq (1 mCi) of F-18 initially and scanned for 310 min. Both phantoms were placed at the center of the FOV. The images were reconstructed by CASToR (Customizable and Advanced Software for Tomographic Reconstruction) using OSEM with 16 iterations and 12 subsets for the hotspot phantom, and 7 iterations and 8 subsets for the brain phantom. The image matrix size was 360 x 360 x 128 with 0.5 x 0.5 x 0.5 mm3 voxels. For image reconstruction, normalization, attenuation correction, inter-crystal scatter (ICS) rejection, and DOI rebinning were performed. The direct normalization was implemented using a 10-inch uniform cylindrical phantom. The Hoffman phantom filled with F-18 was scanned by Siemens Biograph TruePoint PET/CT for comparison.

Results: Our scanner achieved 264 ps, 2.57 mm, and 10.66 % (all in FWHM) TOF, DOI, and energy resolutions, respectively. The reconstructed image of the ultra-micro hotspot phantom at the center of the FOV is shown in Figure 1c. Spots with a diameter of 1.35 mm and larger can be clearly resolved. Figure 1d shows the experimental setup of the 3D Hoffman brain phantom. Reconstructed images of one slice are shown in Figure 1e where the CT image serves as the ground truth for the anatomical structure. The fine details of the cortical grey-white border are perfectly visualized in the Prism-PET image when compared to the Biograph Truepoint PET image.

Conclusions: We thank the Department of Radiology and Center for Biotechnology (CFB) at Stony Brook University for their financial support through the NIH REACH program.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 63, Issue supplement 2
August 1, 2022
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
High Resolution TOF-DOI Prism-PET Brain Scanner: Experimental Results From The First Prototype Scanner
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
High Resolution TOF-DOI Prism-PET Brain Scanner: Experimental Results From The First Prototype Scanner
Xinjie Zeng, Zipai Wang, Wanbin Tan, Xinjie Cao, Anthony Boccia, Dinko Franceschi, Anat Biegon, Wei Zhao, Amirhossein Goldan
Journal of Nuclear Medicine Aug 2022, 63 (supplement 2) 2516;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
High Resolution TOF-DOI Prism-PET Brain Scanner: Experimental Results From The First Prototype Scanner
Xinjie Zeng, Zipai Wang, Wanbin Tan, Xinjie Cao, Anthony Boccia, Dinko Franceschi, Anat Biegon, Wei Zhao, Amirhossein Goldan
Journal of Nuclear Medicine Aug 2022, 63 (supplement 2) 2516;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Investigating the Prospect of Cross Calibrating Bone Density Scanners across a Medical Enterprise
  • DIFFERENCES IN THYROID UPTAKE PERCENTAGE BASED ON COUNTING STATISTICS
  • Monte Carlo N-Particle Code Analysis of Multiple Gamma Camera Components from Varying Manufacturers
Show more Instrumentation

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire