Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis

Motoki Takeuchi, Issa J. Dahabreh, Takashi Nihashi, Mitsunaga Iwata, George M. Varghese and Teruhiko Terasawa
Journal of Nuclear Medicine December 2016, 57 (12) 1913-1919; DOI: https://doi.org/10.2967/jnumed.116.174391
Motoki Takeuchi
1Department of Emergency and General Internal Medicine, Fujita Health University School of Medicine, Toyoake, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Issa J. Dahabreh
2Center for Evidence-based Medicine, Brown University, Providence, Rhode Island
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takashi Nihashi
3Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mitsunaga Iwata
1Department of Emergency and General Internal Medicine, Fujita Health University School of Medicine, Toyoake, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
George M. Varghese
4Department of Infectious Diseases, Christian Medical College, Vellore, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Teruhiko Terasawa
1Department of Emergency and General Internal Medicine, Fujita Health University School of Medicine, Toyoake, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Several studies have assessed nuclear imaging tests for localizing the source of fever in patients with classic fever of unknown origin (FUO); however, the role of these tests in clinical practice remains unclear. We systematically reviewed the test performance, diagnostic yield, and management decision impact of nuclear imaging tests in patients with classic FUO. Methods: We searched PubMed, Scopus, and other databases through October 31, 2015, to identify studies reporting on the diagnostic accuracy or impact on diagnosis and management decisions of 18F-FDG PET alone or integrated with CT (18F-FDG PET/CT), gallium scintigraphy, or leukocyte scintigraphy. Two reviewers extracted data. We quantitatively synthesized test performance and diagnostic yield and descriptively analyzed evidence about the impact on management decisions. Results: We included 42 studies with 2,058 patients. Studies were heterogeneous and had methodologic limitations. Diagnostic yield was higher in studies with higher prevalence of neoplasms and infections. Nonneoplastic causes, such as adult-onset Still’s disease and polymyalgia rheumatica, were less successfully localized. Indirect evidence suggested that 18F-FDG PET/CT had the best test performance and diagnostic yield among the 4 imaging tests; summary sensitivity was 0.86 (95% confidence interval [CI], 0.81–0.90), specificity 0.52 (95% CI, 0.36–0.67), and diagnostic yield 0.58 (95% CI, 0.51–0.64). Evidence on direct comparisons of alternative imaging modalities or on the impact of tests on management decisions was limited. Conclusion: Nuclear imaging tests, particularly 18F-FDG PET/CT, can be useful in identifying the source of fever in patients with classic FUO. The contribution of nuclear imaging may be limited in clinical settings in which infective and neoplastic causes are less common. Studies using standardized diagnostic algorithms are needed to determine the optimal timing for testing and to assess the impact of tests on management decisions and patient-relevant outcomes.

  • FUO
  • FDG-PET
  • FDG-PET/CT
  • gallium scintigraphy
  • leukocyte scintigraphy

Classic fever of unknown origin (FUO) is defined as fever of 38.3°C (101°F) or higher for 3 or more weeks in immunocompetent, otherwise healthy patients with no identified cause of fever after undergoing a set of obligatory investigations (1). Common causes of classic FUO include infections, tumors, and noninfectious inflammatory diseases (2). With recent advances in diagnostic technologies, such as sophisticated imaging tests, improved culture techniques, and molecular diagnostics, the 2 most common causes (infections and neoplasms) have become less common and undiagnosed cases have become more challenging to investigate (3,4).

67Ga scintigraphy was the mainstay staging modality in oncology practice (5) until the introduction of 18F-FDG PET in the 1990s. Because gallium accumulates in both malignant tumors and inflammation, gallium scintigraphy is still used as a component of workup strategies for patients with classic FUO (2,6). Other scintigraphy methods using autologous white blood cells labeled with 111In or 99mTc are also used when infectious causes are suspected (2,6). 18F-FDG PET is a functional imaging modality that can be used for localizing malignant tumors, as well as infectious and noninfectious inflammatory lesions, because 18F-FDG accumulates in malignant cells and activated leukocytes (6).

Several studies have assessed the diagnostic usefulness of nuclear imaging tests for localizing a source of fever in such patients. However, the interpretation of these studies is not straightforward. First, classic FUO has a broad differential diagnosis and FUO causes vary across clinical settings (3,7). Such variation, coupled with differences in preimaging workup algorithms across settings, can affect test performance. Second, variability in the reference standards used across studies (e.g., biopsy for malignancies, cultures for infections, and operational diagnostic criteria for autoimmune disorders) affects the cause-specific performance of tests. Third, nuclear imaging tests are often evaluated using routinely collected clinical data, without a standardized postimaging diagnostic algorithm; in such cases, the imaging results influence the selection of further (confirmatory) tests and may introduce differential verification (8). Fourth, studies focus on a single nuclear imaging test and rarely report direct comparisons among alternative modalities. Previous systematic reviews (9–12) have also focused on single tests and have not provided comparative information. Our review attempts to address some of these challenges by synthesizing current evidence on the diagnostic performance and clinical utility of 18F-FDG PET alone or integrated with CT (18F-FDG PET/CT), gallium scintigraphy, and leukocyte scintigraphy for classic FUO.

MATERIALS AND METHODS

Data Sources and Search Strategy

We searched PubMed and Scopus (from inception until October 31, 2015) with no language restrictions. We used prespecified search terms for the target condition (e.g., “fever of unknown origin” or “FUO”) and the tests of interest (e.g., “scintigraphy”, “PET”, “PET/CT”, or “SPECT”). We perused the reference lists of eligible primary papers and relevant reviews and meta-analyses. We also tracked citations to eligible papers through Scopus, Web of Science, and Google Scholar. Supplemental Table 1 (supplemental materials are available at http://jnm.snmjournals.org) provides the complete search strategy.

Study Selection

Two reviewers independently screened abstracts and examined the full text of potentially eligible papers to identify studies that evaluated 18F-FDG PET or PET/CT using a full-ring scanner, gallium or leukocyte scintigraphy, or SPECT for at least 10 patients with classic FUO. We included only studies that reported sufficient information to calculate sensitivity and specificity, diagnostic yield (the proportion of patients in whom the imaging results were reported to contribute to the diagnosis of FUO causes), or the proportion of patients in whom the imaging results were deemed to have contributed to changes in diagnostic or therapeutic strategies planned before imaging. When multiple studies reported results from potentially overlapping patient groups, we used only information from the largest patient group. We excluded studies that exclusively evaluated patients 17 y or younger or studies that included patients infected with HIV and did not report separate data on non-HIV participants.

Data Extraction and Assessments of Risk of Bias and Applicability

One investigator extracted descriptive information, which was confirmed by a second investigator; discrepancies were resolved by consensus. We extracted information on study design, preimaging tests, characteristics of enrolled patients, FUO causes, index imaging tests and diagnostic criteria (13–16), and the reference standard. We categorized studies into 3 groups (first-, second-, and third-level examinations) based on their preimaging diagnostic workup algorithm. We also classified the reported reference standards into 3 degrees of accuracy (high, moderate, and low accuracy). The supplemental materials provide detailed descriptions.

Two independent reviewers assessed risk of bias and applicability for each eligible study using items based on the QUADAS-2 tool (17). We evaluated the risk of differential verification bias as proposed elsewhere (8). Discrepancies were resolved by consensus.

Data Synthesis

For each study, we constructed a 2 × 2 contingency table consisting of true-positive, false-positive, false-negative, and true-negative results, whereby patients were categorized according to their nuclear imaging test results (positive or negative) and whether the cause of FUO was correctly identified in the imaging-positive sites or not (i.e., a cause was identified outside the imaging-positive sites or the cause remained unknown).

We estimated summary sensitivity and specificity with their corresponding 95% confidence intervals (95% CIs) using bivariate random-effects meta-analysis with binomial within-study likelihood when 4 or more studies were available for the same imaging test (18,19). When a bivariate model failed to converge, we calculated summary sensitivity and specificity separately by univariate random-effects meta-analysis using mixed-effects logistic regression (20,21). We visually assessed between-study heterogeneity by plotting study estimates in the receiver-operating-characteristic (ROC) space (22). We also constructed hierarchical summary ROC curves and obtained the confidence regions for the summary sensitivity and specificity (23). We performed meta-analysis of diagnostic yield using univariate random-effects logistic regression (20). We quantified between-study heterogeneity by estimating the between-study variance. Data on diagnostic or therapeutic decision impact were qualitatively synthesized.

To explore heterogeneity, we used subgroup analyses and univariable meta-regressions, when 10 or more studies with pertinent data were available (24). Specifically, we examined study design, geographic area, clinical context, proportion of identified neoplasms and infections, and use of contrast-enhancement or not for 18F-FDG PET/CT.

In stability analyses, we excluded studies that enrolled patients younger than 18 y and did not report separate data on adult participants. To address the heterogeneity in classification and reporting of benign (spontaneously regressing) causes, we recalculated sensitivity and specificity for each study considering benign cases as disease negative along with cases in which no cause was identified (supplemental materials; Supplemental Table 2).

We visually assessed the results of studies directly comparing test modalities by plotting all estimates from the same study in the ROC space. We did not perform meta-analyses of comparative studies because few studies were available for each comparison. We also indirectly compared test performance by visually assessing summary ROC curves and by estimating relative diagnostic odds ratios comparing alternative imaging tests (24,25). We also performed study-level univariable meta-regressions to assess the difference in diagnostic yield between 2 imaging tests. The detailed methods used for indirect comparisons are described in the supplemental materials.

We did not perform tests for funnel plot asymmetry because they do not provide a valid way for assessing the extent and impact of missing data (26). All analyses were conducted using Stata SE 13.1 (Stata Corp.) and WinBUGS 1.4.3 (MRC Biostatistics Unit) (27). P values were 2-tailed, and statistical significance was defined as a P value of less than 0.05.

RESULTS

Literature Flow and Eligible Studies

We screened 6,351 abstracts and evaluated 83 full-text articles (Fig. 1). The supplemental materials provide a list of excluded studies along with their reasons for exclusion. A total of 43 unique publications (4 comparative and 38 noncomparative studies, including 2,058 unique patients) met our eligibility criteria (Supplemental Table 3). Twenty-two studies (1,137 patients) evaluated 18F-FDG PET/CT, 12 (522 patients) 18F-FDG PET, 6 (397 patients) gallium scintigraphy, and 6 (153 patients) 111In-labeled leukocyte scintigraphy.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Study flow diagram.

Study and Patient Characteristics

Studies of gallium scintigraphy and leukocyte scintigraphy have been published since the 1980s, whereas studies of 18F-FDG PET and 18F-FDG PET/CT are more recent, having been published after 2001 and 2008, respectively (Supplemental Table 3). Studies included a median of 48 patients (minimum–maximum, 10–162). Typically, studies retrospectively assessed nuclear imaging tests as second- or third-level examinations, performed after diagnostic workup that was not standardized in each study. Eight studies (19%) were prospective: 1 study adopted a standardized workup algorithm (28), and 3 studies specified mandatory preimaging tests (29–31) as selection criteria, one of which routinely performed thoracoabdominal contrast-enhanced CT (31). The average preimaging disease duration ranged from 5 to 41 wk. Thirteen studies (31%) reported details on the postimaging diagnostic workup used for each patient. Positive scan results were often verified with invasive but high-accuracy reference standards, such as biopsy (median, 44%; 25th–75th percentile, 38%–64%, of study participants with positive scan vs. median, 13%; 25th–75th percentile, 0%–20%, with negative scan); negative results were typically verified with less-invasive but low-accuracy reference standards, such as clinical follow-up (median, 70%; 25th–75th percentile, 60%–88%). The average postimaging follow-up ranged from 3 to 30 mo (median, 15 mo).

The average age ranged from 42 to 62 y (median, 54 y), and the proportion of patients with specific FUO etiologies varied across studies (Supplemental Table 4). The median proportion of patients with infectious or neoplastic etiologies as a final diagnosis was 48% (minimum–maximum, 23%–80%) for studies of 18F-FDG PET/CT, 31% (minimum–maximum, 10%–80%) for 18F-FDG PET, 42% (minimum–maximum, 26%–58%) for gallium scintigraphy, and 37% (minimum–maximum, 12%–56%) for leukocyte scintigraphy. The proportion of cases deemed to be of infectious or neoplastic etiology was not associated with preimaging workup algorithms (Spearman ρ = 0.065; P = 0.78) or publication year (Spearman ρ = 0.22; P = 0.15). The proportion of undiagnosed cases also varied substantially (minimum–maximum, 4%–56%).

Test Characteristics

The supplemental materials describe how imaging was performed and interpreted. Studies generally adopted standard imaging protocols (13–16), and multiple nuclear medicine physicians visually interpreted the results (Supplemental Tables 5 and 6). Few studies reported diagnostic thresholds for quantitative assessment to support the visual assessment.

Assessment of Study Risk of Bias and Applicability

We had concerns about high risk of bias and limited generalizability in most included studies for all nuclear imaging tests (Supplemental Fig. 1). Specifically, risk of bias due to differential verification (i.e., selection of reference standard tests on the basis of index test results) was a concern in all studies. Further, the nuclear imaging results were suggested as the basis for the final diagnosis of at least 1 case of noninfectious inflammatory diseases (e.g., vasculitis) in 7 studies (32–38); such incorporation of index test results into the reference standard can lead to overestimation of test performance.

Test Performance, Diagnostic Yield, and Impact on Management

Studies of 18F-FDG PET/CT produced heterogeneous estimates of sensitivity and specificity (Supplemental Fig. 2A). The summary sensitivity and specificity were 0.86 (95% CI, 0.81–0.90) and 0.52 (95% CI, 0.36–0.67), respectively (Fig. 2). Summary estimates were stable in subgroup analyses, and meta-regression analysis identified no covariates that significantly related with both sensitivity and specificity (data not shown).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Meta-analysis of sensitivity and specificity. Diamonds (proportional to number of patients) represent point estimates; extending lines represent 95% CI of each estimate.

The diagnostic yield of 18F-FDG PET/CT also varied across studies (Supplemental Fig. 3A). Studies reporting a higher proportion of neoplasms and infections as the cause of FUO also reported a higher diagnostic yield (Spearman ρ = 0.44; P = 0.038) (Fig. 3A). 18F-FDG PET/CT successfully localized a cause of FUO in approximately 60% of patients (summary diagnostic yield, 0.58; 95% CI, 0.51–0.64) (Fig. 4). The summary estimates were similar across subgroups and in stability analyses; meta-regression indicated that the proportion of neoplasms and infections was positively associated with diagnostic yield (P = 0.003). Nonneoplastic causes were less successfully localized; adult-onset Still’s disease, tuberculosis, and polymyalgia rheumatica were the 3 causes for which 18F-FDG PET/CT most often showed no pathologic uptake leading to diagnosis (Supplemental Tables 7 and 8).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Diagnostic yield plotted against prevalence of infections and neoplasms for studies of 18F-FDG PET/CT (A), 18F-FDG PET (B), gallium scintigraphy (C), and leukocyte scintigraphy (D). Size of each circle is proportional to sample size for each study.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Meta-analysis of diagnostic yield. Squares (proportional to numbers of patients) represent point estimates; extending lines represent 95% CI of each estimate.

Studies of 18F-FDG PET reported variable estimates of sensitivity and specificity (Supplemental Fig. 2B). Summary sensitivity and specificity were 0.76 (95% CI, 0.66–0.83) and 0.50 (95% CI, 0.30–0.70), respectively (Fig. 2). In meta-regression, no covariates were significantly associated with both sensitivity and specificity (data not shown). The diagnostic yield also varied across studies (Supplemental Fig. 3B), with a summary estimate of 0.44 (95% CI, 0.31–0.58) (Fig. 4). Again, studies with a higher diagnostic yield also reported a higher proportion of combined neoplasms and infections (Spearman ρ = 0.66; P = 0.020) (Fig. 3B). A positive association was also suggested by meta-regression between the prevalence of neoplasms and infections and diagnostic yield (P = 0.010). Similarly to 18F-FDG PET/CT, standalone 18F-FDG PET frequently failed to localize nonneoplastic causes (Supplemental Tables 7 and 8).

Test performance of gallium scintigraphy was heterogeneous (Fig. 2C). The summary sensitivity and specificity were 0.60 (95% CI, 0.45–0.73) and 0.63 (95% CI, 0.37–0.84), respectively (Fig. 2). Diagnostic yield ranged from 0.21 to 0.54 (Supplemental Fig. 3C), and on average, the location of a source of fever was correctly localized in approximately a third of patients (summary diagnostic yield, 0.35; 95% CI, 0.25–0.46) (Fig. 4). Data on gallium scintigraphy were too sparse for reliable subgroup analysis.

Studies of leukocyte scintigraphy reported rather homogeneous estimates of specificity; however, estimates of sensitivity were variable (Supplemental Fig. 2D). The summary sensitivity and specificity were 0.33 (95% CI, 0.24–0.44) and 0.83 (95% CI, 0.61–0.94), respectively (Fig. 2). Estimates of diagnostic yield ranged from 0.08 to 0.31 (Supplemental Fig. 3D), and overall, the FUO cause was correctly identified on the basis of the scan results in only a fifth of patients (summary diagnostic yield, 0.20; 95% CI, 0.14–0.28) (Fig. 4). The summary estimates were stable in subgroup and sensitivity analyses, although data were limited.

Five studies of 18F-FDG PET/CT (31,39–42), 3 studies of 18F-FDG PET (28,29,37), and 3 studies of leukocyte scintigraphy (43–45) performed univariable or multivariable analyses to identify predictors of the impact of tests on diagnosis or therapeutic management (Supplemental Table 9). The 3 most commonly assessed predictors were c-reactive protein, leukocyte counts, and erythrocyte sedimentation rate, although studies were highly heterogeneous regarding how candidate predictors were measured and how they were incorporated in the models (e.g., dichotomized or transformed). Overall, no predictive model was validated. Three studies (28,34,46) reported how often scans altered diagnosis, and 2 studies (37,46) reported how often scans altered therapeutic decisions (Supplemental Table 10). For example, 18F-FDG PET or PET/CT affected diagnostic and therapeutic management in 44% (46) and 36% of cases (37), respectively.

Comparisons of Test Performance and Diagnostic Yield Among Imaging Tests

One study directly compared 18F-FDG PET with 18F-FDG PET/CT (47), another compared 18F-FDG PET with gallium scintigraphy (48), and 2 compared 18F-FDG PET with leukocyte scintigraphy (49,50). This limited evidence was insufficient to establish any nuclear imaging modality as superior to any other (Supplemental Fig. 4). Regarding indirect comparisons of test performance, visual assessment of the summary ROC curves and meta-regression suggested that 18F-FDG PET/CT outperformed standalone 18F-FDG PET, gallium scintigraphy, and leukocyte scintigraphy (Supplemental Figs. 2 and 5). Similarly, visual and quantitative indirect comparisons of diagnostic yield suggested that 18F-FDG PET/CT was more likely to correctly identify the cause of FUO than alternative tests (Supplemental Figs. 3 and 6). Detailed descriptions are reported in the supplemental materials.

DISCUSSION

We examined 42 studies involving nearly 2,000 patients with classic FUO to evaluate the performance and clinical validity of nuclear imaging modalities for localizing the source of fever. We found that 18F-FDG PET/CT had the best test performance among nuclear imaging tests and correctly pinpointed the anatomic location of FUO pathologies in approximately 60% of patients for whom basic laboratory tests and anatomic imaging had failed. Indirect comparisons of test modalities suggested that 18F-FDG PET/CT had a better performance than alternative nuclear imaging modalities. However, few studies reported direct comparison among tests, and the diagnostic yield of 18F-FDG PET and PET/CT was lower in clinical contexts in which the prevalence of neoplastic and infectious causes of FUO was low. Furthermore, the data on gallium scintigraphy and leukocyte scintigraphy were derived from older studies and thus may not be applicable to contemporary clinical practice.

Our findings about the test performance of 18F-FDG PET and 18F-FDG PET/CT are in general agreement with previous systematic reviews (9–12). However, we extended previous work by examining diagnostic yield and demonstrating a positive association between yield and the prevalence of infections and neoplasms. This suggests that 18F-FDG PET and 18F-FDG PET/CT may be less useful in clinical settings in which these causes are less common. In addition, we assessed evidence on comparative test performance and other outcomes more thoroughly than previous reviews. We found that 18F-FDG PET/CT is the best choice and can localize most malignant or infectious lesions. A negative scan, however, does not exclude other causes of fever, such as noninfectious inflammatory diseases. Gallium scintigraphy can be used to localize malignancies when it is the only readily available modality. Leukocyte scintigraphy has a limited role in most clinical contexts, in view of its low diagnostic yield. Finally, we qualitatively summarized data on the impact of 18F-FDG PET and 18F-FDG PET/CT on diagnostic and therapeutic management. Lack of data, however, precluded reliable assessment on how 18F-FDG PET or 18F-FDG PET/CT affects estimates of the probability of particular FUO cases or how it alters diagnostic or therapeutic management decisions. Arguably, these outcomes are more relevant to clinical practice than test performance, suggesting that more research, ideally comparative studies of alternative testing strategies incorporating nuclear imaging tests, is needed to assess clinical outcomes beyond test performance (51).

Our review has several limitations. First, our summary estimates were based on heterogeneous estimates from studies with varied designs, and we noted substantial between-study heterogeneity. We believe that variability in the prevalence of underlying FUO etiologies across studies and differences in workup algorithms are the main sources of the observed statistical heterogeneity; it is hard to account for these factors without access to primary study data. Second, the included studies used multiple and imperfect reference standards and were deemed likely to have produced biased results because of differential verification and incorporation of the index test result in the reference standard. Differential verification and incorporation bias are likely to lead to overestimation of test performance (52), and thus our summary estimates should be interpreted with caution. Third, our comparative results depend largely on indirect comparisons, which may be confounded by differences across studies that cannot be addressed analytically (25). We thus view our indirect comparisons as suggestive of possible differences among modalities that merit further research in properly designed and conducted comparative studies. Fourth, the available literature provides only limited evidence on the impact of nuclear imaging tests on clinical management.

CONCLUSION

18F-FDG PET/CT, 18F-FDG PET, gallium scintigraphy, and leukocyte scintigraphy are useful imaging modalities for localizing the source of fever in patients with classic FUO for whom a routine diagnostic workup has been unsuccessful in establishing a diagnosis. 18F-FDG PET/CT is the most promising nuclear test, with the highest diagnostic yield. However, little is known about the impact of all nuclear imaging tests on diagnostic and therapeutic decisions. Future studies should use designs with a prespecified diagnostic algorithms before nuclear imaging, and standardized protocols for imaging and image interpretation, to clarify which modalities are most useful. Also, given the heterogeneous test performance across studies and the high cost of nuclear imaging, identifying factors that modify test performance and affect management and using methods that combine nuclear imaging results with other information should be a priority.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This study was supported by MEXT, Japan (No. 26460755). No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Jun. 23, 2016.

  • © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Fauci A,
    2. Hauser S,
    3. Longo D,
    4. Jameson J,
    5. Loscalzo J,
    6. Kasper D
    1. Bleeker-Rovers CP,
    2. van der Meer JWM
    . Fever of unknown origin. In: Fauci A, Hauser S, Longo D, Jameson J, Loscalzo J, Kasper D, eds. Harrison's Principles of Internal Medicine. 19th ed. New York, NY: McGraw Hill; 2015:135–142.
  2. 2.↵
    1. Knockaert DC,
    2. Vanderschueren S,
    3. Blockmans D
    . Fever of unknown origin in adults: 40 years on. J Intern Med. 2003;253:263–275.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Varghese GM,
    2. Trowbridge P,
    3. Doherty T
    . Investigating and managing pyrexia of unknown origin in adults. BMJ. 2010;341:C5470.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Horowitz HW
    . Fever of unknown origin or fever of too many origins? N Engl J Med. 2013;368:197–199.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Hicks RJ,
    2. Hofman MS
    . Is there still a role for SPECT-CT in oncology in the PET-CT era? Nat Rev Clin Oncol. 2012;9:712–720.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Baert AL,
    2. Sartor K,
    3. Schiepers C
    1. Rennen HJM,
    2. Bleeker-Rovers C,
    3. Oyen WG
    . Imaging infection and inflammation. In: Baert AL, Sartor K, Schiepers C, eds. Diagnostic Nuclear Medicine. Berlin Heidelberg, Germany: Springer; 2006:113–126.
  7. 7.↵
    1. Mourad O,
    2. Palda V,
    3. Detsky AS
    . A comprehensive evidence-based approach to fever of unknown origin. Arch Intern Med. 2003;163:545–551.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Naaktgeboren CA,
    2. de Groot JA,
    3. van Smeden M,
    4. Moons KG,
    5. Reitsma JB
    . Evaluating diagnostic accuracy in the face of multiple reference standards. Ann Intern Med. 2013;159:195–202.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Dong MJ,
    2. Zhao K,
    3. Liu ZF,
    4. Wang GL,
    5. Yang SY,
    6. Zhou GJ
    . A meta-analysis of the value of fluorodeoxyglucose-PET/PET-CT in the evaluation of fever of unknown origin. Eur J Radiol. 2011;80:834–844.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Hao R,
    2. Yuan L,
    3. Kan Y,
    4. Li C,
    5. Yang J
    . Diagnostic performance of 18F-FDG PET/CT in patients with fever of unknown origin: a meta-analysis. Nucl Med Commun. 2013;34:682–688.
    OpenUrlCrossRefPubMed
  11. 11.
    1. van der Ende EL,
    2. Punwasia RVG,
    3. van Daeleb PLA,
    4. Schurinkc KAM
    . Diagnostic value of FDG-PET/CT in fever of unknown origin. Erasmus J Med. 2013;3:32–37.
    OpenUrl
  12. 12.↵
    1. Sioka C,
    2. Assimakopoulos A,
    3. Fotopoulos A
    . The diagnostic role of 18F fluorodeoxyglucose positron emission tomography in patients with fever of unknown origin. Eur J Clin Invest. 2015;45:601–608.
    OpenUrl
  13. 13.↵
    1. Jamar F,
    2. Buscombe J,
    3. Chiti A,
    4. et al
    . EANM/SNMMI guideline for 18F-FDG use in inflammation and infection. J Nucl Med. 2013;54:647–658.
    OpenUrlFREE Full Text
  14. 14.
    1. Palestro C,
    2. Brown M,
    3. Forstrom L,
    4. et al
    . Society of Nuclear Medicine procedure guideline for gallium scintigraphy in inflammation 3.0. SNMMI website. http://snmmi.files.cms-plus.com/docs/Gallium_Scintigraphy_in_Inflammation_v3.pdf. Approved June 2, 2004. Accessed July 20, 2016.
  15. 15.
    1. Roca M,
    2. de Vries EF,
    3. Jamar F,
    4. Israel O,
    5. Signore A
    . Guidelines for the labelling of leucocytes with 111In-oxine. Eur J Nucl Med Mol Imaging. 2010;37:835–841.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Palestro C,
    2. Brown M,
    3. Forstrom L,
    4. et al
    . Society of Nuclear Medicine Procedure guideline for 111 In-leukocyte scintigraphy for suspected infection/inflammation. SNMMI website. http://snmmi.files.cms-plus.com/docs/Leukocyte_v3.pdf. Approved June 2, 2004. Accessed July 20, 2016.
  17. 17.↵
    1. Whiting PF,
    2. Rutjes AWS,
    3. Westwood ME,
    4. et al
    . QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–536.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Reitsma JB,
    2. Glas AS,
    3. Rutjes AW,
    4. Scholten RJ,
    5. Bossuyt PM,
    6. Zwinderman AH
    . Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol. 2005;58:982–990.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Chu H,
    2. Cole SR
    . Bivariate meta-analysis of sensitivity and specificity with sparse data: a generalized linear mixed model approach. J Clin Epidemiol. 2006;59:1331–1332, author reply 1332–1333.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Trikalinos TA,
    2. Trow P,
    3. Schmid CH
    . Simulation-based comparison of methods for meta-analysis of proportions and rates. AHRQ Publication No. 13(14)-EHC084-EF. Rockville, MD: Agency for Healthcare Research and Quality; 2013.
  21. 21.↵
    1. Takwoingi Y,
    2. Guo B,
    3. Riley RD,
    4. Deeks JJ
    . Performance of methods for meta-analysis of diagnostic test accuracy with few studies or sparse data. Stat Methods Med Res. June 26, 2015 [Epub ahead of print].
  22. 22.↵
    1. Phillips B,
    2. Stewart LA,
    3. Sutton AJ
    . ‘Cross hairs’ plots for diagnostic meta-analysis. Res Synth Methods. 2010;1:308–315.
    OpenUrl
  23. 23.↵
    1. Harbord RM,
    2. Deeks JJ,
    3. Egger M,
    4. Whiting P,
    5. Sterne JA
    . A unification of models for meta-analysis of diagnostic accuracy studies. Biostatistics. 2007;8:239–251.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Macaskill P,
    2. Gatsonis C,
    3. Deeks J,
    4. Harbord R,
    5. Takwoingi Y
    . Cochrane handbook for systematic reviews of diagnostic test accuracy. Cochrane website. http://dta.cochrane.org/sites/dta.cochrane.org/files/uploads/Chapter%2010%20-%20Version%201.0.pdf. Accessed July 20, 2016.
  25. 25.↵
    1. Takwoingi Y,
    2. Leeflang MM,
    3. Deeks JJ
    . Empirical evidence of the importance of comparative studies of diagnostic test accuracy. Ann Intern Med. 2013;158:544–554.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Sterne JAC,
    2. Sutton AJ,
    3. Ioannidis JPA,
    4. et al
    . Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ. 2011;343:d4002.
    OpenUrlFREE Full Text
  27. 27.↵
    1. Thompson J
    . Bayesian Analysis with Stata. College Station, TX: Stata Press; 2014.
  28. 28.↵
    1. Bleeker-Rovers CP,
    2. Vos FJ,
    3. Mudde AH,
    4. et al
    . A prospective multi-centre study of the value of FDG-PET as part of a structured diagnostic protocol in patients with fever of unknown origin. Eur J Nucl Med Mol Imaging. 2007;34:694–703.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Buysschaert I,
    2. Vanderschueren S,
    3. Blockmans D,
    4. Mortelmans L,
    5. Knockaert D
    . Contribution of 18fluoro-deoxyglucose positron emission tomography to the work-up of patients with fever of unknown origin. Eur J Intern Med. 2004;15:151–156.
    OpenUrlCrossRefPubMed
  30. 30.
    1. Meller J,
    2. Altenvoerde G,
    3. Munzel U,
    4. et al
    . Fever of unknown origin: prospective comparison of [18F]FDG imaging with a double-head coincidence camera and gallium-67 citrate SPET. Eur J Nucl Med. 2000;27:1617–1625.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Singh N,
    2. Kumar R,
    3. Malhotra A,
    4. Bhalla AS,
    5. Kumar U,
    6. Sood R
    . Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin. Indian J Nucl Med. 2015;30:204–212.
    OpenUrl
  32. 32.↵
    1. Balink H,
    2. Collins J,
    3. Bruyn GA,
    4. Gemmel F
    . F-18 FDG PET/CT in the diagnosis of fever of unknown origin. Clin Nucl Med. 2009;34:862–868.
    OpenUrlCrossRefPubMed
  33. 33.
    1. Federici L,
    2. Blondet C,
    3. Imperiale A,
    4. et al
    . Value of 18F-FDG-PET/CT in patients with fever of unknown origin and unexplained prolonged inflammatory syndrome: a single centre analysis experience. Int J Clin Pract. 2010;64:55–60.
    OpenUrlCrossRefPubMed
  34. 34.↵
    1. Manohar K,
    2. Mittal BR,
    3. Jain S,
    4. et al
    . F-18 FDG-PET/CT in evaluation of patients with fever of unknown origin. Jpn J Radiol. 2013;31:320–327.
    OpenUrlCrossRefPubMed
  35. 35.
    1. Pedersen TI,
    2. Roed C,
    3. Knudsen LS,
    4. Loft A,
    5. Skinhoj P,
    6. Nielsen SD
    . Fever of unknown origin: a retrospective study of 52 cases with evaluation of the diagnostic utility of FDG-PET/CT. Scand J Infect Dis. 2012;44:18–23.
    OpenUrlCrossRefPubMed
  36. 36.
    1. Pelosi E,
    2. Skanjeti A,
    3. Penna D,
    4. Arena V
    . Role of integrated PET/CT with [18F]-FDG in the management of patients with fever of unknown origin: a single-centre experience. Radiol Med (Torino). 2011;116:809–820.
    OpenUrl
  37. 37.↵
    1. Kubota K,
    2. Nakamoto Y,
    3. Tamaki N,
    4. et al
    . FDG-PET for the diagnosis of fever of unknown origin: a Japanese multi-center study. Ann Nucl Med. 2011;25:355–364.
    OpenUrlCrossRefPubMed
  38. 38.↵
    1. Lorenzen J,
    2. Buchert R,
    3. Bohuslavizki KH
    . Value of FDG PET in patients with fever of unknown origin. Nucl Med Commun. 2001;22:779–783.
    OpenUrlCrossRefPubMed
  39. 39.↵
    1. Crouzet J,
    2. Boudousq V,
    3. Lechiche C,
    4. et al
    . Place of 18F-FDG-PET with computed tomography in the diagnostic algorithm of patients with fever of unknown origin. Eur J Clin Microbiol Infect Dis. 2012;31:1727–1733.
    OpenUrlCrossRefPubMed
  40. 40.
    1. Kim YJ,
    2. Kim SI,
    3. Hong KW,
    4. Kang MW
    . Diagnostic value of 18F-FDG PET/CT in patients with fever of unknown origin. Intern Med J. 2012;42:834–837.
    OpenUrlPubMed
  41. 41.
    1. Zheng Y,
    2. Lu W,
    3. Pan Q
    . Effect of 18F-FDG PET/CT on etiological diagnosis for fever of unknown origin (FUO). J Clin Oncol. 2013;19:936–939.
    OpenUrl
  42. 42.↵
    1. Gafter-Gvili A,
    2. Raibman S,
    3. Grossman A,
    4. et al
    . [18F]FDG-PET/CT for the diagnosis of patients with fever of unknown origin. QJM. 2015;108:289–298.
    OpenUrlAbstract/FREE Full Text
  43. 43.↵
    1. Kelly MJ,
    2. Kalff V,
    3. Hicks R,
    4. Spicer W,
    5. Spelman D
    . 111In-oxine labelled leukocyte scintigraphy in the detection and localization of active inflammation and sepsis. Med J Aust. 1990;152:352–357.
    OpenUrlPubMed
  44. 44.
    1. Kjaer A,
    2. Lebech A
    . Diagnostic value of 111In-granulocyte scintigraphy in patients with fever of unknown origin. J Nucl Med. 2002;43:140–144.
    OpenUrlAbstract/FREE Full Text
  45. 45.↵
    1. Syrjälä MT,
    2. Valtonen V,
    3. Liewendahl K,
    4. Myllylä G
    . Diagnostic significance of indium-111 granulocyte scintigraphy in febrile patients. J Nucl Med. 1987;28:155–160.
    OpenUrlAbstract/FREE Full Text
  46. 46.↵
    1. Tokmak H,
    2. Ergonul O,
    3. Demirkol O,
    4. Cetiner M,
    5. Ferhanoglu B
    . Diagnostic contribution of 18F-FDG-PET/CT in fever of unknown origin. Int J Infect Dis. 2014;19:53–58.
    OpenUrlCrossRefPubMed
  47. 47.↵
    1. Kang L,
    2. Xu X,
    3. Fan Y,
    4. et al
    . Diagnostic value of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in fever of unknown origin [in Chinese]. Beijing Da Xue Xue Bao. 2015;47:175–180.
    OpenUrl
  48. 48.↵
    1. Blockmans D,
    2. Knockaert D,
    3. Maes A,
    4. et al
    . Clinical value of [18F]fluoro-deoxyglucose positron emission tomography for patients with fever of unknown origin. Clin Infect Dis. 2001;32:191–196.
    OpenUrlAbstract/FREE Full Text
  49. 49.↵
    1. Kjaer A,
    2. Lebech AM,
    3. Eigtved A,
    4. Hojgaard L
    . Fever of unknown origin: prospective comparison of diagnostic value of 18F-FDG PET and 111In-granulocyte scintigraphy. Eur J Nucl Med Mol Imaging. 2004;31:622–626.
    OpenUrlCrossRefPubMed
  50. 50.↵
    1. Seshadri N,
    2. Sonoda LI,
    3. Lever AM,
    4. Balan K
    . Superiority of 18F-FDG PET compared to 111In-labelled leucocyte scintigraphy in the evaluation of fever of unknown origin. J Infect. 2012;65:71–79.
    OpenUrlCrossRefPubMed
  51. 51.↵
    1. Dahabreh IJ,
    2. Gatsonis C
    . A flexible, multifaceted approach is needed in health technology assessment of PET. J Nucl Med. 2014;55:1225–1227.
    OpenUrlFREE Full Text
  52. 52.↵
    1. Whiting PF,
    2. Rutjes AW,
    3. Westwood ME,
    4. Mallett S
    . A systematic review classifies sources of bias and variation in diagnostic test accuracy studies. J Clin Epidemiol. 2013;66:1093–1104.
    OpenUrlCrossRefPubMed
  • Received for publication February 18, 2016.
  • Accepted for publication May 31, 2016.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 57 (12)
Journal of Nuclear Medicine
Vol. 57, Issue 12
December 1, 2016
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis
Motoki Takeuchi, Issa J. Dahabreh, Takashi Nihashi, Mitsunaga Iwata, George M. Varghese, Teruhiko Terasawa
Journal of Nuclear Medicine Dec 2016, 57 (12) 1913-1919; DOI: 10.2967/jnumed.116.174391

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis
Motoki Takeuchi, Issa J. Dahabreh, Takashi Nihashi, Mitsunaga Iwata, George M. Varghese, Teruhiko Terasawa
Journal of Nuclear Medicine Dec 2016, 57 (12) 1913-1919; DOI: 10.2967/jnumed.116.174391
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Nuclear Imaging of Bacterial Infection: The State of the Art and Future Directions
  • The diagnostic value of 18F-FDG PET/CT in identifying the causes of fever of unknown origin
  • Key diagnostic characteristics of fever of unknown origin in Japanese patients: a prospective multicentre study
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • FUO
  • FDG-PET
  • FDG-PET/CT
  • gallium scintigraphy
  • leukocyte scintigraphy
SNMMI

© 2025 SNMMI

Powered by HighWire